Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Elife ; 122024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747706

RESUMO

Quiescence (G0) maintenance and exit are crucial for tissue homeostasis and regeneration in mammals. Here, we show that methyl-CpG binding protein 2 (Mecp2) expression is cell cycle-dependent and negatively regulates quiescence exit in cultured cells and in an injury-induced liver regeneration mouse model. Specifically, acute reduction of Mecp2 is required for efficient quiescence exit as deletion of Mecp2 accelerates, while overexpression of Mecp2 delays quiescence exit, and forced expression of Mecp2 after Mecp2 conditional knockout rescues cell cycle reentry. The E3 ligase Nedd4 mediates the ubiquitination and degradation of Mecp2, and thus facilitates quiescence exit. A genome-wide study uncovered the dual role of Mecp2 in preventing quiescence exit by transcriptionally activating metabolic genes while repressing proliferation-associated genes. Particularly disruption of two nuclear receptors, Rara or Nr1h3, accelerates quiescence exit, mimicking the Mecp2 depletion phenotype. Our studies unravel a previously unrecognized role for Mecp2 as an essential regulator of quiescence exit and tissue regeneration.


Assuntos
Proteína 2 de Ligação a Metil-CpG , Animais , Proteína 2 de Ligação a Metil-CpG/metabolismo , Proteína 2 de Ligação a Metil-CpG/genética , Camundongos , Camundongos Knockout , Receptores Citoplasmáticos e Nucleares/metabolismo , Receptores Citoplasmáticos e Nucleares/genética , Ciclo Celular , Regeneração Hepática/genética , Regulação da Expressão Gênica
2.
Phytochemistry ; 223: 114113, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38697241

RESUMO

Eleven undescribed cembrane-type diterpenoids, named litoamentenes A-K (1-11), were isolated from the soft coral Litophyton amentaceum collected from the South China Sea. Their structures were elucidated by extensive analysis of spectroscopic data, comparison with the literature data, single crystal X-ray diffraction, quantum chemical calculations and TDDFT-ECD calculations. This is the first systematic investigation of L. amentaceum. In particular, compounds 1-3 are cembrane-type norditerpenoids that lack isopropyl side chains. Compound 6 is a cembrane-type norditerpenoid without a methyl group at C-4, the first natural product identified with this carbon skeleton. Compounds 6, 9 and 10 showed modest cytotoxicity against several human cancer cell lines with IC50 values ranging from 3.99 to 14.56 µM.


Assuntos
Antozoários , Diterpenos , Ensaios de Seleção de Medicamentos Antitumorais , Antozoários/química , Diterpenos/química , Diterpenos/farmacologia , Diterpenos/isolamento & purificação , Animais , Humanos , Estrutura Molecular , Relação Estrutura-Atividade , Antineoplásicos/farmacologia , Antineoplásicos/química , Antineoplásicos/isolamento & purificação , China , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Relação Dose-Resposta a Droga , Modelos Moleculares
3.
Phys Med Biol ; 69(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38821109

RESUMO

Objective.The validation of deformable image registration (DIR) for contour propagation is often done using contour-based metrics. Meanwhile, dose accumulation requires evaluation of voxel mapping accuracy, which might not be accurately represented by contour-based metrics. By fabricating a deformable anthropomorphic pelvis phantom, we aim to (1) quantify the voxel mapping accuracy for various deformation scenarios, in high- and low-contrast regions, and (2) identify any correlation between dice similarity coefficient (DSC), a commonly used contour-based metric, and the voxel mapping accuracy for each organ.Approach. Four organs, i.e. pelvic bone, prostate, bladder and rectum (PBR), were 3D printed using PLA and a Polyjet digital material, and assembled. The latter three were implanted with glass bead and CT markers within or on their surfaces. Four deformation scenarios were simulated by varying the bladder and rectum volumes. For each scenario, nine DIRs with different parameters were performed on RayStation v10B. The voxel mapping accuracy was quantified by finding the discrepancy between true and mapped marker positions, termed the target registration error (TRE). Pearson correlation test was done between the DSC and mean TRE for each organ.Main results. For the first time, we fabricated a deformable phantom purely from 3D printing, which successfully reproduced realistic anatomical deformations. Overall, the voxel mapping accuracy dropped with increasing deformation magnitude, but improved when more organs were used to guide the DIR or limit the registration region. DSC was found to be a good indicator of voxel mapping accuracy for prostate and rectum, but a comparatively poorer one for bladder. DSC > 0.85/0.90 was established as the threshold of mean TRE ⩽ 0.3 cm for rectum/prostate. For bladder, extra metrics in addition to DSC should be considered.Significance. This work presented a 3D printed phantom, which enabled quantification of voxel mapping accuracy and evaluation of correlation between DSC and voxel mapping accuracy.


Assuntos
Pelve , Imagens de Fantasmas , Humanos , Pelve/diagnóstico por imagem , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Masculino , Impressão Tridimensional
4.
Phys Med ; 122: 103380, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38805761

RESUMO

INTRODUCTION: Real-time gated proton therapy (RGPT) is a motion management technique unique to the Hitachi particle therapy system. It uses pulsed fluoroscopy to track an implanted fiducial marker. There are currently no published guidelines on how to conduct the commissioning and quality assurance. In this work we reported on our centre's commissioning workflow and our daily and monthly QA procedures. METHODS: Six commissioning measurements were designed for RGPT. The measurements include imaging qualities, fluoroscopic exposures, RGPT marker tracking accuracy, temporal gating latency, fiducial marker tracking fidelity and an end-to-end proton dosimetry measurement. Daily QA consists of one measurement on marker localization accuracy. Four months daily QA trends are presented. Monthly QA consists of three measurementson the gating latency, fluoroscopy imaging quality and dosimetry verification of gating operation with RGPT. RESULTS: The RGPT was successfully commissioned in our centre. The air kerma rates were within 15 % from specifications and the marker tracking accuracies were within 0.245 mm. The gating latencies for turning the proton beam on and off were 119.5 and 50.0 ms respectively. The 0.4x10.0 mm2 Gold AnchorTM gave the best tracking results with visibility up to 30 g/cm2. Gamma analysis showed that dose distribution of a moving and static detectors had a passing rate of more than 95 % at 3 %/3mm. The daily marker localization QA results were all less than 0.2 mm. CONCLUSION: This work could serve as a good reference for other upcoming Hitachi particle therapy centres who are interested to use RGPT as their motion management solution.


Assuntos
Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde , Terapia com Prótons/instrumentação , Marcadores Fiduciais , Radiometria , Fatores de Tempo , Fluoroscopia , Controle de Qualidade , Humanos , Radioterapia Guiada por Imagem
5.
J Appl Clin Med Phys ; : e14348, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561975

RESUMO

INTRODUCTION: Daily quality assurance is an integral part of a radiotherapy workflow to ensure the dose is delivered safely and accurately to the patient. It is performed before the first treatment of the day and needs to be time and cost efficient for a multiple gantries proton center. In this study, we introduced an efficient method to perform QA for output constancy, range verification, spot positioning accuracy and imaging and proton beam isocenter coincidence with DailyQA3. METHODS: A stepped acrylic block of specific dimensions is fabricated and placed on top of the DailyQA3 device. Treatment plans comprising of two different spread-out Bragg peaks and five individual spots of 1.0 MU each are designed to be delivered to the device. A mathematical framework to measure the 2D distance between the detectors and individual spot is introduced and play an important role in realizing the spot positioning and centering QA. Lastly, a 5 months trends of the QA for two gantries are presented. RESULTS: The outputs are monitored by two ion chambers in the DailyQA3 and a tolerance of ± 3 % $ \pm 3\% $ are used. The range of the SOBPs are monitored by the ratio of ion chamber signals and a tolerance of ± 1 mm $ \pm 1\ {\mathrm{mm}}$ is used. Four diodes at ± 10 cm $ \pm 10\ {\mathrm{cm}}$ from the central ion chambers are used for spot positioning QA, while the central ion chamber is used for imaging and proton beam isocenter coincidence QA. Using the framework, we determined the absolute signal threshold corresponding to the offset tolerance between the individual proton spot and the detector. A 1.5 mm $1.5\ {\mathrm{mm}}$ tolerances are used for both the positioning and centering QA. No violation of the tolerances is observed in the 5 months trends for both gantries. CONCLUSION: With the proposed approach, we can perform four QA items in the TG224 within 10 min.

6.
Mar Drugs ; 22(4)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38667762

RESUMO

Four undescribed sesquiterpenoids, lemneolemnanes A-D (1-4), have been isolated from the marine soft coral Lemnalia sp. The absolute configurations of the stereogenic carbons of 1-4 were determined by single-crystal X-ray crystallographic analysis. Compounds 1 and 2 are epimers at C-3 and have an unusual skeleton with a formyl group on C-6. Compound 3 possesses an uncommonly rearranged carbon skeleton, while 4 has a 6/5/5 tricyclic system. Compound 1 showed significant anti-Alzheimer's disease (AD) activity in a humanized Caenorhabditis elegans AD pathological model.


Assuntos
Antozoários , Caenorhabditis elegans , Sesquiterpenos , Animais , Antozoários/química , Sesquiterpenos/farmacologia , Sesquiterpenos/química , Sesquiterpenos/isolamento & purificação , Caenorhabditis elegans/efeitos dos fármacos , Cristalografia por Raios X , Doença de Alzheimer/tratamento farmacológico , Modelos Animais de Doenças , Humanos , Estrutura Molecular
7.
Phys Med ; 120: 103341, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38554639

RESUMO

BACKGROUND AND PURPOSE: This work introduces the first assessment of CT calibration following the ESTRO's consensus guidelines and validating the HLUT through the irradiation of biological material. METHODS: Two electron density phantoms were scanned with two CT scanners using two CT scan energies. The stopping power ratio (SPR) and mass density (MD) HLUTs for different CT scan energies were derived using Schneider's and ESTRO's methods. The comparison metric in this work is based on the Water-Equivalent Thickness (WET) difference between the treatment planning system and biological irradiation measurement. The SPR HLUTs were compared between the two calibration methods. To assess the accuracy of using MD HLUT for dose calculation in the treatment planning system, MD vs SPR HLUT was compared. Lastly, the feasibility of using a single SPR HLUT to replace two different energy CT scans was explored. RESULTS: The results show a WET difference of less than 3.5% except for the result in the Bone region between Schneider's and ESTRO's methods. Comparing MD and SPR HLUT, the results from MD HLUT show less than a 3.5% difference except for the Bone region. However, the SPR HLUT shows a lower mean absolute percentage difference as compared to MD HLUT between the measured and calculated WET difference. Lastly, it is possible to use a single SPR HLUT for two different CT scan energies since both WET differences are within 3.5%. CONCLUSION: This is the first report on calibrating an HLUT following the ESTRO's guidelines. While our result shows incremental improvement in range uncertainty using the ESTRO's guideline, the prescriptional approach of the guideline does promote harmonization of CT calibration protocols between different centres.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Calibragem , Água
8.
Ann Emerg Med ; 83(4): 407-408, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519205
9.
Phys Imaging Radiat Oncol ; 29: 100552, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38405428

RESUMO

Background and purpose: High-density dental fillings pose a non-negligible impact on head and neck cancer treatment. For proton therapy, stopping power ratio (SPR) prediction will be significantly impaired by the associated image artifacts. Dose perturbation is also inevitable, compromising the treatment plan quality. While plenty of work has been done on metal or amalgam fillings, none has touched on composite resin (CR) and glass ionomer cement (GIC) which have seen an increasing usage. Hence, this work aims to provide a detailed characterisation of SPR and dose perturbation in proton therapy caused by CR and GIC. Materials and methods: Four types of fillings were used: CR, Fuji Bulk (FB), Fuji II (FII) and Fuji IX (FIX). The latter three belong to GIC category. Measured SPR were compared with SPR predicted using single-energy computed tomography (SECT) and dual-energy computed tomography (DECT). Dose perturbation of proton beams with lower- and higher-energy levels was also quantified using Gafchromic films. Results: The measured SPR for CR, FB, FII and FIX were 1.68, 1.77, 1.77 and 1.76, respectively. Overall, DECT could predict SPR better than SECT. The lowest percentage error achieved by DECT was 19.7 %, demonstrating the challenge in estimating SPR, even for fillings with relatively lower densities. For both proton beam energies and all four fillings of about 4.5 mm thickness, the maximum dose perturbation was 3 %. Conclusion: This study showed that dose perturbation by CR and GIC was comparatively small. We have measured and recommended the SPR values for overriding the fillings in TPS.

10.
J Appl Clin Med Phys ; 25(2): e14154, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37683120

RESUMO

BACKGROUND: Tolerance limit is defined on pre-treatment patient specific quality assurance results to identify "out of the norm" dose discrepancy in plan. An out-of-tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out-of-tolerance plan early during treatment planning phase to mitigate the above-mentioned risks. METHODS: Patient-specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion-specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field-robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1-score calculated from both the inliers and validation outliers' data. RESULTS: 308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1-score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion. CONCLUSION: The model will help the planner to identify an out-of-tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Algoritmos , Pelve , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos , Garantia da Qualidade dos Cuidados de Saúde
12.
Phys Med Biol ; 68(22)2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37857314

RESUMO

Introduction. Dispersion in an accelerator quantifies the deviation of the proton trajectory when there is a momentum deviation. We present for the first time a safe method of measuring dispersion in the clinic, using a scintillator detector and the momentum deviations within a spill. This is an important accelerator quantity as we found that this is the reason behind the large dose fluctuation in our absolute dosimetry measurement.Methods. Dispersions are measured for nine energies in a Hitachi ProBeat system at three locations (isocenter and at two profile monitors) and at two gantry angles (0 and 90 degrees) by first measuring the spot position and momentum drift within a spill. The spot position drift is measured by the XRV-4000 at the isocenter, and by the two profile monitors located at 0.57 and 2.27 m from the isocenter. The momentum drift is calculated from the intra-spill range drift which is measured using the Ranger accessory. The dispersion at isocenter and its gradient are calculated using the weighted least square regression on the measured dispersions at the three locations. A constraint is formulated on the dispersion and its gradient to ensure minimal intra-spill spot position deviation around the isocenter.Results. The measured intra-spill range and spot positional drift at isocenter are less than0.25mmand0.7mmrespectively. The momentum spread calculated from the range drift are less than 0.08%. The dispersion at the isocenter ranged from0.50to4.30mand the zero-crossing happens upstream of isocenter for all energies. 2 of the 9 energies (168.0 and 187.5 MeV) violated the constraint and has an intra-spill spot positional deviation greater than1.0within5cmfrom the isocenter.Conclusion. This measurement is recommended as part of commissioning and annual quality assurance for accelerator monitoring and to ensure intra-spill spot deviations remain low.


Assuntos
Terapia com Prótons , Terapia com Prótons/métodos , Radiometria , Prótons , Movimento (Física)
13.
Phys Med Biol ; 68(15)2023 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-37437590

RESUMO

Objective. Automatic deformable image registration (DIR) is a critical step in adaptive radiotherapy. Manually delineated organs-at-risk (OARs) contours on planning CT (pCT) scans are deformably registered onto daily cone-beam CT (CBCT) scans for delivered dose accumulation. However, evaluation of registered contours requires human assessment, which is time-consuming and subjects to high inter-observer variability. This work proposes a deep learning model that allows accurate prediction of Dice similarity coefficients (DSC) of registered contours in prostate radiotherapy.Approach. Our dataset comprises 20 prostate cancer patients with 37-39 daily CBCT scans each. The pCT scans and planning contours were deformably registered to each corresponding CBCT scan to generate virtual CT (vCT) scans and registered contours. The DSC score, which is a common contour-based validation metric for registration quality, between the registered and manual contours were computed. A Siamese neural network was trained on the vCT-CBCT image pairs to predict DSC. To assess the performance of the model, the root mean squared error (RMSE) between the actual and predicted DSC were computed.Main results. The model showed promising results for predicting DSC, giving RMSE of 0.070, 0.079 and 0.118 for rectum, prostate, and bladder respectively on the holdout test set. Clinically, a low RMSE implies that the predicted DSC can be reliably used to determine if further DIR assessment from physicians is required. Considering the event where a registered contour is classified as poor if its DSC is below 0.6 and good otherwise, the model achieves an accuracy of 92% for the rectum. A sensitivity of 0.97 suggests that the model can correctly identify 97% of poorly registered contours, allowing manual assessment of DIR to be triggered.Significance. We propose a neural network capable of accurately predicting DSC of deformably registered OAR contours, which can be used to evaluate eligibility for plan adaptation.


Assuntos
Neoplasias de Cabeça e Pescoço , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
14.
Polymers (Basel) ; 15(11)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37299299

RESUMO

Non-isocyanate Polyurethane (NIPU) has been known to result from a thermal-ring-opening reaction between bis-cyclic carbonate (BCC) compounds and polyamines. BCC can be obtained from carbon dioxide capture using an epoxidized compound. Microwave radiation has been found to be an alternative process to conventional heating for synthesizing NIPU on a laboratory scale. The microwave radiation process is far more efficient (>1000 times faster) than using a conventional heating reactor. Now, a flow tube reactor has been designed for a continuous and recirculating microwave radiation system for scaling up NIPU. Furthermore, the TOE (Turn Over Energy) of the microwave for a lab batch (24.61 g) reactor was 24.38 kJ/g. This decreased to 8.89 kJ/g with an increase in reaction size of up to 300 times with this new continuous microwave radiation system. This proves that synthesizing NIPU with this newly-designed continuous and recirculating microwave radiation process is not only a reliable energy-saving method, but is also convenient for scale-up, making it a green process.

15.
Angew Chem Int Ed Engl ; 62(14): e202216977, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36753392

RESUMO

Post-synthetic modification (PSM) is an effective approach for the tailored functionalization of metal-organic architectures, but its generalizability remains challenging. Herein we report a general covalent PSM strategy to functionalize Pdn L2n metal-organic cages (MOCs, n=2, 12) through an efficient Diels-Alder cycloaddition between peripheral anthracene substituents and various functional motifs bearing a maleimide group. As expected, the solubility of functionalized Pd12 L24 in common solvents can be greatly improved. Interestingly, concentration-dependent circular dichroism and aggregation-induced emission are achieved with chiral binaphthol (BINOL)- and tetraphenylethylene-modified Pd12 L24 , respectively. Furthermore, Pd12 L24 can be introduced with two different functional groups (e.g., chiral BINOL and achiral pyrene) through a step-by-step PSM route to obtain chirality-induced circularly polarized luminescence. Moreover, similar results are readily observed with a smaller Pd2 L4 system.

17.
Braz. j. otorhinolaryngol. (Impr.) ; 88(5): 733-739, Sept.-Oct. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403920

RESUMO

Abstract Introduction The Epley maneuver is useful for the otoconia to return from the long arm of the posterior semicircular canal into the utricle. To move otoconia out of the posterior semicircular canal short arm and into the utricle, we need different maneuvers. Objective To diagnose the short-arm type BPPV of the posterior semicircular canal and treat them with bow-and-yaw maneuver. Methods 171 cases were diagnosed as BPPV of the posterior semicircular canal based on a positive Dix-Hallpike maneuver. We first attempted to treat patients with the bow-and-yaw maneuver and then performed the Dix-Hallpike maneuver again. If the repeated Dix-Hallpike maneuver gave negative results, we diagnosed the patient with the short-arm type of BPPV of the posterior semicircular canal and considered the patient to have been cured by the bow-and-yaw maneuver; otherwise, probably the long-arm type BPPV of the posterior semicircular canal existed and we treated the patient with the Epley maneuver. Results Approximately 40% of the cases were cured by the bow-and-yaw maneuver, giving negative results on repeated Dix-Hallpike maneuvers, and were diagnosed with short-arm lithiasis. Conclusion The short-arm type posterior semicircular canal BPPV can be diagnosed and treated in a convenient and comfortable manner.


Resumo Introdução A manobra de Epley é útil para o retorno da otocônia do braço longo do canal semicircular posterior para o utrículo. Diferentes manobras são necessárias para mover a otocônia para fora do braço curto do canal semicircular posterior e para dentro do utrículo. Objetivo Diagnosticar a VPPB do tipo braço curto do canal semicircular posterior e tratá-la com a manobra de incline and balance. Método Foram diagnosticados 171 casos como VPPB de canal semicircular posterior com base na manobra de Dix-Hallpike positiva. Primeiro tentamos tratar os pacientes com a manobra de incline and balance e, em seguida, executamos a manobra de Dix-Hallpike novamente. Se a repetição da manobra de Dix-Hallpike desse resultados negativos, diagnosticávamos o paciente como VPPB do canal semicircular posterior do tipo braço curto e considerávamos que ele ou ela havia sido curado pela manobra de incline and balance; caso contrário, provavelmente o paciente apresentava VPPB do canal semicircular posterior do tipo braço longo e tratávamos o paciente com a manobra de Epley. Resultados Aproximadamente 40% dos casos foram curados pela manobra de incline and balance, com resultados negativos nas manobras de Dix-Hallpike repetidas, e foram diagnosticados com litíase de braço curto. Conclusão A VPPB de canal semicircular posterior do tipo braço curto pode ser diagnosticada e tratada de maneira conveniente e confortável.

18.
Diabetes Obes Metab ; 24(11): 2182-2191, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35762489

RESUMO

AIMS: To evaluate the efficacy and safety of iGlarLixi compared with iGlar in Chinese adults with type 2 diabetes advancing therapy from basal insulin ± oral antihyperglycaemic drugs. MATERIALS AND METHODS: LixiLan-L-CN (NCT03798080) was a 30-week randomized, active-controlled, open-label, parallel-group, multicentre study. Participants were randomized 1:1 to iGlarLixi or iGlar. The primary objective was to show the superiority of iGlarLixi over iGlar in glycated haemoglobin (HbA1c) change from baseline to Week 30. RESULTS: In total, 426 participants were randomized to iGlarLixi (n = 212) or iGlar (n = 214). Mean age was 58 years, 67% had a body mass index ≥24 kg/m2 , corresponding to overweight/obesity, and the mean diabetes duration was 12.3 years. From mean baseline HbA1c of 8.1% in both groups, greater decreases were seen with iGlarLixi versus iGlar [least squares mean difference: -0.7 (95% confidence interval: -0.9, -0.6)%; p < .0001] to final HbA1c of 6.7% and 7.4%, respectively. HbA1c <7.0% achievement was greater with iGlarLixi (63.3%) versus iGlar (29.9%; p < .0001). Mean body weight decreased with iGlarLixi and increased with iGlar [least squares mean difference: -0.9 (95% confidence interval: -1.4, -0.5) kg; p = .0001]. Hypoglycaemia incidence was similar between groups. Few gastrointestinal adverse events occurred (rated mild/moderate) with a slightly higher incidence with iGlarLixi than iGlar. CONCLUSIONS: iGlarLixi provided better glycaemic control and facilitated more participants to reach glycaemic targets alongside beneficial effects on body weight, no additional risk of hypoglycaemia, and few gastrointestinal AEs, supporting iGlarLixi use as an efficacious and well tolerated therapy option in Chinese people with long-standing T2D advancing therapy from basal insulin.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Adulto , Glicemia , China/epidemiologia , Diabetes Mellitus Tipo 2/induzido quimicamente , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/epidemiologia , Combinação de Medicamentos , Hemoglobinas Glicadas/análise , Controle Glicêmico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina Glargina/efeitos adversos , Pessoa de Meia-Idade , Obesidade/tratamento farmacológico , Peptídeos/uso terapêutico
19.
J Pers Med ; 12(5)2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35629117

RESUMO

Predicting the treatment response to antidepressants by pretreatment features would be useful, as up to 70-90% of patients with major depressive disorder (MDD) do not respond to treatment as expected. Therefore, we aim to establish a deep neural network (DNN) model of deep learning to predict the treatment outcomes of antidepressants in drug-naïve and first-diagnosis MDD patients during severe depressive stage using different domains of signature profiles of clinical features, peripheral biochemistry, psychosocial factors, and genetic polymorphisms. The multilayer feedforward neural network containing two hidden layers was applied to build models with tenfold cross-validation. The areas under the curve (AUC) of the receiver operating characteristic curves were used to evaluate the performance of the models. The results demonstrated that the AUCs of the model ranged between 0.7 and 0.8 using a combination of different domains of categorical variables. Moreover, models using the extracted variables demonstrated better performance, and the best performing model was characterized by an AUC of 0.825, using the levels of cortisol and oxytocin, scales of social support and quality of life, and polymorphisms of the OXTR gene. A complex interactions model developed through DNN could be useful at the clinical level for predicting the individualized outcomes of antidepressants.

20.
Beilstein J Org Chem ; 18: 374-380, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35495775

RESUMO

Four new polyhydroxylated steroids lobophysterols E-H (1-4), together with three known compounds (5-7), were isolated from the soft coral Lobophytum pauciflorum collected at Xisha Island, China. The structures of the new compounds were elucidated by extensive spectroscopic analysis and comparison with NMR data of structurally related compounds reported in the literature. The absolute configuration of 1-3 was determined by X-ray diffraction. All the compounds have assessed the cytotoxicity against HL-60, K562, and Hela cells. Compound 1 showed weak cytotoxicity against K562 cells with an IC50 value of 19.03 µM. In addition, compound 1 also showed a moderate anti-inflammatory effect in zebrafish.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA