Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Pain ; 164(10): 2306-2315, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37463229

RESUMO

ABSTRACT: The neural mechanisms for the persistence of pain after a technically successful arthroplasty in osteoarthritis (OA) remain minimally studied, and direct evidence of the brain as a predisposing factor for pain chronicity in this setting has not been investigated. We undertook this study as a first effort to identify presurgical brain and clinical markers of postarthroplasty pain in knee OA. Patients with knee OA (n = 81) awaiting total arthroplasty underwent clinical and psychological assessment and brain magnetic resonance imagining. Postoperative pain scores were measured at 6 months after surgery. Brain subcortical anatomic properties (volume and shape) and clinical indices were studied as determinants of postoperative pain. We show that presurgical subcortical volumes (bilateral amygdala, thalamus, and left hippocampus), together with shape deformations of the right anterior hippocampus and right amygdala, associate with pain persistence 6 months after surgery in OA. Longer pain duration, higher levels of presurgical anxiety, and the neuropathic character of pain were also prognostic of postsurgical pain outcome. Brain and clinical indices accounted for unique influences on postoperative pain. Our study demonstrates the presence of presurgical subcortical brain factors that relate to postsurgical persistence of OA pain. These preliminary results challenge the current dominant view that mechanisms of OA pain predominantly underlie local joint mechanisms, implying novel clinical management and treatment strategies.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Medição da Dor/métodos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Dor Pós-Operatória/diagnóstico por imagem , Dor Pós-Operatória/etiologia , Encéfalo/diagnóstico por imagem , Biomarcadores , Resultado do Tratamento
2.
Am J Phys Med Rehabil ; 102(6): 513-521, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730791

RESUMO

INTRODUCTION: Assessing functional improvement after intensive care unit discharge is particularly challenging. The aim of this study was to measure the association between (1) changes in knee extension muscle strength or quadriceps femoris and rectus femoris muscle thickness and (2) changes in functionality/function-related measurements in post-intensive care unit patients. METHODS: This prospective cohort study included adult patients without previous disability, consecutively selected after intensive care unit discharge. Some parameters, such as Short-Form 36, 6-min walking test, 1-min sit-to-stand, and Short Physical Performance Battery, were measured at baseline and 3 and 6 mos after discharge. Correlations were assessed and regression models were built to assess the association between evolution in knee extension strength or muscle thickness and evolution in functional tests. RESULTS: Thirty patients completed the follow-up. Moderate correlation was found between knee extension strength change and Short-Form 36 physical functioning (correlation coefficient [ ρ ] = 0.53), 6-min walking test ( ρ = 0.38), 1-min sit-to-stand ( ρ = 0.52), and Short Physical Performance Battery ( ρ = 0.38). Baseline values and changes in knee extension strength moderately predicted evolution in Short-Form 36 physical functioning ( r2 = 0.32, P = 0.006). Changes in muscle thickness were overall not associated with changes in functional variables. CONCLUSION: Changes in knee extension muscle strength may inform on functional progression over time after intensive care unit discharge, although confirmatory studies are needed.


Assuntos
Articulação do Joelho , Alta do Paciente , Adulto , Humanos , Estudos Prospectivos , Extremidade Inferior , Força Muscular/fisiologia , Unidades de Terapia Intensiva
3.
Eur J Phys Rehabil Med ; 58(5): 767-773, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36052891

RESUMO

BACKGROUND: Point-of-care ultrasound can be used to assess muscle thickness. However, its reliability has not been fully evaluated. AIM: This study aimed to assess the intrarater and inter-rater reliability of point-of-care ultrasound for the estimation of quadriceps and rectus femoris thickness in patients from a rehabilitation setting. DESIGN: This is a cross-sectional study. SETTING: This study was conducted at the Department of Physical Medicine and Rehabilitation of a tertiary care hospital. POPULATION: Twenty-nine inpatients consecutively selected after admission. METHODS: Four observers, two trained and two untrained, used point-of-care ultrasound to measure quadriceps femoris and rectus femoris thickness. Each observer performed two measurements followed by a second set of two measurements three hours later. Intraclass correlation coefficients (ICC) were then calculated. RESULTS: Both intrarater and inter-rater ICC were higher than 0.888 for both quadriceps and rectus femoris measurements. Reliability was highest when ICC were calculated based on the average of two measurements, with the intrarater ICC being of 0.956 (95% CI: 0.937-0.970) for rectus femoris and of 0.966 (95% CI: 0.951-0.976) for quadriceps femoris; and with the inter-rater ICC being of 0.919 (95% CI: 0.863-0.957) for rectus femoris and 0.945 (95% CI: 0.907- 0.971) for quadriceps femoris. Trained and untrained observers did not have significantly different ICC values. CONCLUSIONS: These results suggest that point-of-care ultrasound is a reliable option to measure muscle thickness of knee extensors by the same or different observers. CLINICAL REHABILITATION IMPACT: Measuring knee extensors thickness may aid to adequately modulate treatment choices in patients with disability. This study suggests that quadriceps and rectus femoris muscle thickness measured after a short training course, by either an experienced or inexperienced clinician, presents high reliability. Reliability can be increased if the average of two measurements is used. Besides being inexpensive and portable, point-of-care ultrasound is a reliable tool for measuring knee extensors' thickness, rendering it potentially adequate to be used in clinical practice.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Músculo Quadríceps , Estudos Transversais , Humanos , Músculo Quadríceps/diagnóstico por imagem , Músculo Quadríceps/fisiologia , Reprodutibilidade dos Testes , Ultrassonografia/métodos
4.
PLoS One ; 17(5): e0268254, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35580110

RESUMO

INTRODUCTION: The Handheld Dynamometer (HHD) has the potential to overcome some of the logistic and economic limitations of isokinetic dynamometers for measuring knee extension muscle strength. However, its reliability has not been fully assessed. The purpose of this study is to measure intra and inter-rater reliability of HHD for knee extension strength in patients receiving rehabilitation treatment, as well as to understand in which conditions is the reliability higher. METHODS: Twenty-nine patients admitted in an inpatient Physical Medicine and Rehabilitation unit were consecutively included in this cross-sectional study. Two experienced and two inexperienced physicians made two assessments of knee extension strength with HHD, separated by three hours. Intraclass Correlation Coefficients (ICC), absolute differences between assessments, and correlations between strength and functional variables were calculated. RESULTS: Intra and inter-rater ICC were overall high (≥ 0.950 and 0.927, respectively). Higher values were found when average of two measurements were made for estimating intra-rater ICC (ICC = 0.978; 95%CI = 0.969-0.985) but not for inter-rater ICC. ICC were not statistically significantly different when calculated based on measurements performed by inexperienced physicians and experienced ones. There was a moderate correlation between strength and functional variables. CONCLUSION: Handheld Dynamometer seems to be a reliable option to measure knee extension muscle strength, particularly when two measurements are performed and their average is reported.


Assuntos
Articulação do Joelho , Joelho , Estudos Transversais , Humanos , Joelho/fisiologia , Articulação do Joelho/fisiologia , Força Muscular/fisiologia , Dinamômetro de Força Muscular , Reprodutibilidade dos Testes
5.
PLoS One ; 15(1): e0222370, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31914126

RESUMO

A significant proportion of osteoarthritis (OA) patients continue to experience moderate to severe pain after total joint replacement (TJR). Preoperative factors related to pain persistence are mainly studied using individual predictor variables and distinct pain outcomes, thus leading to a lack of consensus regarding the influence of preoperative parameters on post-TJR pain. In this prospective observational study, we evaluated knee and hip OA patients before, 3 and 6 months post-TJR searching for clinical predictors of pain persistence. We assessed multiple measures of quality, mood, affect, health and quality of life, together with radiographic evaluation and performance-based tasks, modeling four distinct pain outcomes. Multivariate regression models and network analysis were applied to pain related biopsychosocial measures and their changes with surgery. A total of 106 patients completed the study. Pre-surgical pain levels were not related to post-surgical residual pain. Although distinct pain scales were associated with different aspects of post-surgical pain, multi-factorial models did not reliably predict post-surgical pain in knee OA (across four distinct pain scales) and did not generalize to hip OA. However, network analysis showed significant changes in biopsychosocial-defined OA personality post-surgery, in both groups. Our results show that although tested clinical and biopsychosocial variables reorganize after TJR in OA, their presurgical values are not predictive of post-surgery pain. Derivation of prognostic markers for pain persistence after TJR will require more comprehensive understanding of underlying mechanisms.


Assuntos
Osteoartrite do Quadril/cirurgia , Osteoartrite do Joelho/cirurgia , Manejo da Dor , Dor Pós-Operatória/terapia , Idoso , Artroplastia de Substituição/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Medição da Dor/métodos , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/fisiopatologia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA