Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39012179

RESUMO

Inertial confinement fusion experiments taking place at the National Ignition Facility are generating ever increasing amounts of fusion energy, with the deuterium tritium fusion neutron yield growing a hundredfold over the past ten years. Strategies must be developed to mitigate this harsh environment's deleterious effects on the operation and the performance of the time-resolved x-ray imagers deployed in the National Ignition Facility target bay to record the dynamics of the implosions. We review the evolution of these imagers in recent years and detail some of the past and present efforts undertaken to maintain or improve the quality of the experimental data collected on high neutron yield experiments. These include the use of a dump-and-read electronic backend, the selection of photographic film with a low background sensitivity, and the optical filtering of Cherenkov radiation.

2.
Rev Sci Instrum ; 93(8): 083516, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050109

RESUMO

The hardened single line of sight camera has been recently characterized in preparation for its deployment on the National Ignition Facility. The latest creation based on the pulse-dilation technology leads to many new features and improvements over the previous-generation cameras to provide better quality measurements of inertial confinement fusion experiments, including during high neutron yield implosions. Here, we present the characterization data that illustrate the main performance features of this instrument, such as extended dynamic range and adjustable internal magnification, leading to improved spatial resolution.

3.
Rev Sci Instrum ; 87(11): 11E202, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910532

RESUMO

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

4.
Rev Sci Instrum ; 83(10): 10D729, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126901

RESUMO

Electromagnetic interference (EMI) is an ever-present challenge at laser facilities such as the National Ignition Facility (NIF). The major source of EMI at such facilities is laser-target interaction that can generate intense electromagnetic fields within, and outside of, the laser target chamber. In addition, the diagnostics themselves can be a source of EMI, even interfering with themselves. In this paper we describe EMI generated by ARIANE and DIXI, present measurements, and discuss effects of the diagnostic-generated EMI on ARIANE's CCD and on a PMT nearby DIXI. Finally we present some of the efforts we have made to mitigate the effects of diagnostic-generated EMI on NIF diagnostics.

5.
Rev Sci Instrum ; 81(10): 10E538, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034065

RESUMO

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 µm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA