Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 58(5): A202-A208, 2019 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-30873979

RESUMO

Deep artificial neural network learning is an emerging tool in image analysis. We demonstrate its potential in the field of digital holographic microscopy by addressing the challenging problem of determining the in-focus reconstruction depth of Madin-Darby canine kidney cell clusters encoded in digital holograms. A deep convolutional neural network learns the in-focus depths from half a million hologram amplitude images. The trained network correctly determines the in-focus depth of new holograms with high probability, without performing numerical propagation. This paper reports on extensions to preliminary work published earlier as one of the first applications of deep learning in the field of digital holographic microscopy.

2.
Appl Opt ; 57(22): E190-E198, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30117884

RESUMO

Water-related diseases affect societies in all parts of the world. Online sensors are considered a solution to the problems associated with laboratory testing in potable water. One of the most active research areas of such online sensors has been within optics. Digital holographic microscopy (DHM) has the potential to rival state-of-the-art techniques such as advanced turbidity measurement. However, its use as an online sensor is limited by the large data requirements typical for digital holographic video. In this paper, we provide a solution that permits DHM to be applied to a whole class of online remote sensor networks, of which potable water analysis is one example. The designed sensors incorporate a novel space-variant quantization algorithm to preprocess each frame of a video sequence before transmission over a network. The system satisfies the generally accepted requirements of an online system: automated, near real-time, and operating in a real environment. To verify the effectiveness of the design, we implemented and evaluated it in an active potable water facility.


Assuntos
Água Potável/química , Holografia/métodos , Microscopia/métodos , Algoritmos , Compressão de Dados , Desenho de Equipamento , Processamento de Sinais Assistido por Computador/instrumentação
3.
Histopathology ; 72(2): 227-238, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28771788

RESUMO

AIMS: Evaluating expression of the human epidermal growth factor receptor 2 (HER2) by visual examination of immunohistochemistry (IHC) on invasive breast cancer (BCa) is a key part of the diagnostic assessment of BCa due to its recognized importance as a predictive and prognostic marker in clinical practice. However, visual scoring of HER2 is subjective, and consequently prone to interobserver variability. Given the prognostic and therapeutic implications of HER2 scoring, a more objective method is required. In this paper, we report on a recent automated HER2 scoring contest, held in conjunction with the annual PathSoc meeting held in Nottingham in June 2016, aimed at systematically comparing and advancing the state-of-the-art artificial intelligence (AI)-based automated methods for HER2 scoring. METHODS AND RESULTS: The contest data set comprised digitized whole slide images (WSI) of sections from 86 cases of invasive breast carcinoma stained with both haematoxylin and eosin (H&E) and IHC for HER2. The contesting algorithms predicted scores of the IHC slides automatically for an unseen subset of the data set and the predicted scores were compared with the 'ground truth' (a consensus score from at least two experts). We also report on a simple 'Man versus Machine' contest for the scoring of HER2 and show that the automated methods could beat the pathology experts on this contest data set. CONCLUSIONS: This paper presents a benchmark for comparing the performance of automated algorithms for scoring of HER2. It also demonstrates the enormous potential of automated algorithms in assisting the pathologist with objective IHC scoring.


Assuntos
Algoritmos , Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Receptor ErbB-2/análise , Feminino , Humanos , Imuno-Histoquímica
4.
Appl Opt ; 53(15): 3233-40, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24922208

RESUMO

Digital holographic microscopy enables the capture of large three-dimensional volumes. Instead of using a laser as an illumination source, partially coherent alternatives can be used, such as light-emitting diodes, which produce parasitic reflection and speckle-free holograms. Captured high-contrast holograms are suitable for the characterization of micrometer-sized particles. As the reconstructed phase is not usable in the case of multiple overlapping objects, depth extraction can be conducted on a reconstructed intensity. This work introduces a novel depth extraction algorithm that takes into consideration the possible locations of multiple objects at various depths in the imaged volume. The focus metric, the Tamura coefficient, is applied for each pixel in the reconstructed amplitude throughout the volume. This work also introduces an optimized version of the algorithm, which is run in two stages. During the first stage, coarse positions of the objects are extracted by applying the Tamura coefficient to nonoverlapping window blocks of intensity reconstructions. The second stage produces high-precision characterizations of the objects by calculating the Tamura coefficient with overlapping window blocks around axial positions extracted in the first stage. Experimental results with real-world microscopic objects show the effectiveness of the proposed method.

5.
Opt Lett ; 36(11): 2035-7, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21633440

RESUMO

Depth extraction is an important aspect of three-dimensional (3D) image processing with digital holograms and an essential step in extended focus imaging and metrology. All available depth extraction techniques with macroscopic objects are based on variance; however, the effectiveness of this is object dependent. We propose to use disparity between corresponding points in intensity reconstructions to determine depth. Our method requires a single hologram of a scene, from which we reconstruct two different perspectives. In the reconstruction the phase information is not needed, which makes this method useful for in-line digital holography. To our knowledge disparity based 3D image processing has never been proposed before for digital holography.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA