Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
IEEE Open J Eng Med Biol ; 5: 133-139, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487093

RESUMO

Goal: We present a new framework for in vivo image guidance evaluation and provide a case study on robotic partial nephrectomy. Methods: This framework (called the "bystander protocol") involves two surgeons, one who solely performs the therapeutic process without image guidance, and another who solely periodically collects data to evaluate image guidance. This isolates the evaluation from the therapy, so that in-development image guidance systems can be tested without risk of negatively impacting the standard of care. We provide a case study applying this protocol in clinical cases during robotic partial nephrectomy surgery. Results: The bystander protocol was performed successfully in 6 patient cases. We find average lesion centroid localization error with our IGS system to be 6.5 mm in vivo compared to our prior result of 3.0 mm in phantoms. Conclusions: The bystander protocol is a safe, effective method for testing in-development image guidance systems in human subjects.

2.
IEEE Trans Med Robot Bionics ; 2(2): 196-205, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-36176345

RESUMO

Partial nephrectomy involves removing a tumor while sparing surrounding healthy kidney tissue. Compared to total kidney removal, partial nephrectomy improves outcomes for patients but is underutilized because it is challenging to accomplish minimally invasively, requiring accurate spatial awareness of unseen subsurface anatomy. Image guidance can enhance spatial awareness by displaying a 3D model of anatomical relationships derived from medical imaging information. It has been qualitatively suggested that the da Vinci robot is well suited to facilitate image guidance through touch-based registration. In this paper we validate and advance this concept toward real-world use in several important ways. First, we contribute the first quantitative accuracy evaluation of touch-based registration with the da Vinci. Next, we demonstrate real-time touch-based registration and display of medical images for the first time. Lastly, we perform the first experiments validating use of touch-based image guidance to improve a surgeon's ability to localize subsurface anatomical features in a geometrically realistic phantom.

3.
Oper Neurosurg (Hagerstown) ; 13(1): 15-22, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28580377

RESUMO

BACKGROUND: The recent development of MRI-guided laser-induced thermal therapy (LITT) offers a minimally invasive alternative to craniotomies performed for tumor resection or for amygdalohippocampectomy to control seizure disorders. Current LITT therapies rely on linear stereotactic trajectories that mandate twist-drill entry into the skull and potentially long approaches traversing healthy brain. The use of robotically-driven, telescoping, curved needles has the potential to reduce procedure invasiveness by tailoring trajectories to the curved shape of the ablated structure and by enabling access through natural orifices. OBJECTIVE: To investigate the feasibility of using a concentric tube robot to access the hippocampus through the foramen ovale to deliver thermal therapy and thereby provide a percutaneous treatment for epilepsy without drilling the skull. METHODS: The skull and both hippocampi were segmented from dual CT/MR image volumes for 10 patients. For each of the 20 hippocampi, a concentric tube robot was designed and optimized to traverse a trajectory from the foramen ovale to and through the hippocampus from head to tail. RESULTS: Across all 20 cases, the mean distances (error) between hippocampus medial axis and backbone of the needle were 0.55 mm, 1.11 mm, and 1.66 mm for best, mean, and worst case, respectively. CONCLUSION: These curvilinear trajectories would provide accurate transforamenal delivery of an ablation probe to typical hippocampus volumes. This strategy has the potential to both decrease the invasiveness of the procedure and increase the completeness of hippocampal ablation.


Assuntos
Hipocampo/cirurgia , Terapia a Laser/métodos , Agulhas , Procedimentos Cirúrgicos Robóticos/métodos , Terapia Combinada , Simulação por Computador , Epilepsia do Lobo Temporal/cirurgia , Desenho de Equipamento , Hipocampo/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Terapia a Laser/instrumentação , Imagem por Ressonância Magnética Intervencionista , Procedimentos Cirúrgicos Robóticos/instrumentação , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA