Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 115111, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461550

RESUMO

The development and characterization of an angle-resolved photoelectron spectrometer, based on the electron time-of-flight concept, for hard x-ray photon diagnostics at the European Free-Electron Laser, are described. The instrument is meant to provide users and operators with pulse-resolved, non-invasive spectral distribution diagnostics, which in the hard x-ray regime is a challenge due to the poor cross-section and high kinetic energy of photoelectrons for the available target gases. We report on the performances of this instrument as obtained using hard x-rays at the PETRA III synchrotron at DESY in multibunch mode. Results are compared with electron trajectory simulations. We demonstrate a resolving power of 10 eV at incident photon energies up to at least 20 keV.

2.
Rev Sci Instrum ; 91(10): 103101, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33138553

RESUMO

The European X-ray Free-Electron Laser Facility in Germany delivers x-ray pulses with femtosecond pulse duration at a repetition rate of up to 4.5 MHz. The free-electron laser radiation is created by the self-amplified spontaneous emission (SASE) process, whose stochastic nature gives rise to shot-to-shot fluctuations in most beam properties, including spectrum, pulse energy, spatial profile, wavefront, and temporal profile. Each spectrum consisting of many spikes varies in width and amplitude that appear differently within the envelope of the SASE spectrum. In order to measure and study the SASE spectrum, the HIgh REsolution hard X-ray single-shot (HIREX) spectrometer was installed in the photon tunnel of the SASE1 undulator beamline. It is based on diamond gratings, bent crystals as a dispersive element, and a MHz-repetition-rate strip detector. It covers a photon energy range of 3 keV-25 keV and a bandwidth of 0.5% of the SASE beam. The SASE spikes are resolved with 0.15 eV separation using the Si 440 reflection, providing a resolving power of 60 000 at a photon energy of 9.3 keV. The measured SASE bandwidth is 25 eV. In this paper, we discuss the design specifications, installation, and commissioning of the HIREX spectrometer. The spectral results using Si (110), Si (111), and C (110) crystals are presented.

3.
J Synchrotron Radiat ; 26(Pt 5): 1489-1495, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490136

RESUMO

X-ray photon beam diagnostic imagers are located at 24 positions in the European XFEL beam transport system to characterize the X-ray beam properties, and to give feedback for tuning and optimization of the electron acceleration and orbit, the undulators, and the X-ray optics. One year of commissioning allowed experience to be gained with these imagers, which will be reported here. The sensitive Spontaneous Radiation imager is useful for various investigations in spontaneous radiation mode: for undulator adjustments and for low-signal imaging applications. The high-resolution Free-Electron Laser imager, 10 µm spatial resolution, is extensively used for the monitoring of beam position, spot size and shape, gain curve measurements, and also for beam-intensity monitoring. The wide field-of-view pop-in monitors (up to 200 mm) are regularly used for alignment and tuning of the various X-ray optical components like mirrors, slits and monochromators, and also for on-line beam control of a stable beam position at the instruments. The Exit Slit imager after the soft X-ray monochromator provides spectral information of the beam together with multi-channel plate based single-pulse gating. For particular use cases, these special features of the imagers are described. Some radiation-induced degradation of scintillators took place in this initial commissioning phase, providing useful information for better understanding of damage thresholds. Visible-light radiation in the beam pipe generated by upstream bending magnets caused spurious reflections in the optical system of some of the imagers which can be suppressed by aluminium-coated scintillating screens.


Assuntos
Lasers , Monitoramento de Radiação/métodos , Artefatos , Desenho de Equipamento , Europa (Continente) , Óptica e Fotônica , Fótons , Raios X
4.
J Synchrotron Radiat ; 26(Pt 4): 1010-1016, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274422

RESUMO

Commissioning and first operation of an angle-resolved photoelectron spectrometer for non-invasive shot-to-shot diagnostics at the European XFEL soft X-ray beamline are described. The objective with the instrument is to provide the users and operators with reliable pulse-resolved information regarding photon energy and polarization that opens up a variety of applications for novel experiments but also hardware optimization.


Assuntos
Espectroscopia Fotoeletrônica/instrumentação , Raios X , Europa (Continente) , Fótons
5.
J Synchrotron Radiat ; 26(Pt 4): 1045-1051, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274426

RESUMO

X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam position monitoring. They are used for tuning and maintaining the self-amplified spontaneous emission (SASE) operation and for sorting single-shot experimental data according to the pulse-resolved energy monitor data. The XGMs were developed at DESY based on the specific requirements for the European XFEL. In total, six XGM units are continuously in operation. Here, the main principle and experimental setup of an XGM are summarized, and the locations of the six XGMs at the facility are shown. Pulse energy measurements at 0.134 nm wavelength are presented, exceeding 1 mJ obtained with an absolute measurement uncertainty of 7-10%; correlations between different XGMs are shown, from which a SASE1 beamline transmission of 97% is deduced. Additionally, simultaneous position measurements close to the undulator and at the end of the tunnel are shown, along with the correlation of beam position data simultaneously acquired by an XGM and an imager.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA