Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Epilepsia Open ; 7(1): 36-45, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34786887

RESUMO

OBJECTIVE: The question of whether a patient with presumed temporal lobe seizures should proceed directly to temporal lobectomy surgery versus undergo intracranial monitoring arises commonly. We evaluate the effect of intracranial monitoring on seizure outcome in a retrospective cohort of consecutive subjects who specifically underwent an anterior temporal lobectomy (ATL) for refractory temporal lobe epilepsy (TLE). METHODS: We performed a retrospective analysis of 85 patients with focal refractory TLE who underwent ATL following: (a) intracranial monitoring via craniotomy and subdural/depth electrodes (SDE/DE), (b) intracranial monitoring via stereotactic electroencephalography (sEEG), or (c) no intracranial monitoring (direct ATL-dATL). For each subject, the presurgical primary hypothesis for epileptogenic zone localization was characterized as unilateral TLE, unilateral TLE plus (TLE+), or TLE with bilateral/poor lateralization. RESULTS: At one-year and most recent follow-up, Engel Class I and combined I/II outcomes did not differ significantly between the groups. Outcomes were better in the dATL group compared to the intracranial monitoring groups for lesional cases but were similar in nonlesional cases. Those requiring intracranial monitoring for a hypothesis of TLE+had similar outcomes with either intracranial monitoring approach. sEEG was the only approach used in patients with bilateral or poorly lateralized TLE, resulting in 77.8% of patients seizure-free at last follow-up. Importantly, for 85% of patients undergoing SEEG, recommendation for ATL resulted from modifying the primary hypothesis based on iEEG data. SIGNIFICANCE: Our study highlights the value of intracranial monitoring in equalizing seizure outcomes in difficult-to-treat TLE patients undergoing ATL.


Assuntos
Craniotomia , Convulsões , Liberdade , Humanos , Estudos Retrospectivos , Convulsões/cirurgia , Resultado do Tratamento
2.
Epilepsy Res ; 169: 106522, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33296809

RESUMO

BACKGROUND: Ictal Single Photon Emission Computed Tomography (iSPECT) is one of the established tools utilized in the presurgical evaluation of patients with drug-resistant epilepsy (DRE). Timely isotope injection for an iSPECT is critical for optimal yield but poses logistical challenges when done manually. We aim to evaluate the added value of automatic iSPECT injectors (ASIs) in overcoming such challenges. METHODS: We retrospectively reviewed all cases admitted to the University of Pittsburgh Medical Center (UPMC) Epilepsy Monitoring Unit from Jan 1, 2010, through Dec 31, 2016, who underwent an iSPECT. We compared the manually injected iSPECTs with those performed with ASIs. RESULTS: A total of 123 iSPECTs were reviewed. The manually injected iSPECT group consisted of 35 patients (median age, 35 years; and 19 males). The automatically injected iSPECT group consisted of 88 patients (median age, 36 years; and 46 males). The two groups were comparable in age, gender, epilepsy treatment, focal features on neuropsychological testing (NPT), EEG, and MRI, and temporal origin of seizures (p > 0.05). Compared to manually injected iSPECTs, automatically injected ISPECTs' median injection latency (IL) was shorter (18.5 vs. 60 s, p < 0.001); the ratio of IL/total duration of seizure was lower (0.395 vs. 0.677, p < 0.001); postictal injections were less frequent (4 (4.5 %) vs. 7 (20 %), p = 0.007); the number of isotope spills was less (zero vs. 3, p = 0.022); and successfully localizing iSPECTs were more prevalent (81.8 % vs. 62.9 %, p = 0.025), even after adjusting for focal features on NPT, EEG, and MRI, the temporal origin of seizures, and seizure duration (OR of 5.539, 95 %CI = 1.653-18.563, p = 0.006). CONCLUSIONS: Utilization of ASIs leads to a significant shortening of iSPECT IL with less postictal injections, provides a safer injection option for the EMU staff, and leads to a significant improvement in the number of successfully localizing iSPECTs.


Assuntos
Eletroencefalografia , Epilepsia , Convulsões , Adulto , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Convulsões/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
3.
Front Neurol ; 11: 595454, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33178129

RESUMO

Background: Laser interstitial thermal therapy (LiTT) has emerged as a minimally invasive option for surgical treatment of refractory epilepsy. However, LiTT of the mesial temporal (MT) structures is still inferior to anterior temporal lobectomy (ATL) in terms of postoperative outcome. In this pilot study, we identify intracranial EEG (iEEG) biomarkers that distinguish patients with favorable outcome from those with poor outcome after MT LiTT. Methods: We performed a retrospective review of 9 adult refractory epilepsy patients who underwent stereotactic electroencephalography (sEEG) followed by LiTT of MT structures. Their iEEG was retrospectively reviewed in both time and frequency domains. Results: In the time-domain, the presence of sustained 14-30 Hz in MT electrodes coupled with its absence from extra-MT electrodes at ictal onset was highly correlated with favorable outcomes, whereas the appearance of sustained 14-30 Hz or >30 Hz activity in extra-MT sites was negatively correlated to favorable outcomes. In the frequency domain, a declining spectral phase, beginning at the high frequency range (>14 Hz) at ictal onset and following a smooth progressive decline toward lower frequencies as the seizure further evolved, was positively correlated with improved outcomes. On the contrary, low frequency (<14 Hz) patterns and "crescendo-decrescendo" patterns with an early increasing frequency component at ictal onset that reaches the high-beta and low gamma bands before decreasing smoothly, were both correlated with poor surgical outcomes. Conclusions: This pilot study demonstrates the first evidence that iEEG analysis can provide neurophysiological markers for successful MT LiTT and therefore we strongly advocate for systematic sEEG investigations before offering MT LiTT to TLE and MTLE patients.

4.
Epilepsy Behav ; 78: 73-77, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29175694

RESUMO

Our goal was to evaluate how accurate neurologists are at differentiating between different paroxysmal events based on clinical history versus observation of the spell in question. Forty-seven neurologists reviewed 12 clinical histories and videos of recorded events of patients admitted in the Epilepsy Monitoring Unit (EMU). They were asked to diagnose events as epileptic seizures, non-epileptic behavioral spells (NEBS), or other physiologic events as well as rate their confidence in their diagnosis. The median diagnostic accuracy for all paroxysmal events was 67% for clinical history and 75% for observation (p=.001). This was largely due to the difference in accuracy within the subgroup of patients with NEBS (67% history vs. 83% observation, p<.001). There were trends for higher diagnostic accuracy and increased inter-rater agreement with higher levels of training. Physicians with higher levels of training were more confident with diagnosis based on observation. In summary, reviewing videos of paroxysmal spells may improve diagnostic accuracy and enhance the evaluation of patients. Neurologists at all levels of training should encourage the recording and review of videos of recurrent spells to aid in medical decision-making especially when there is high concern that the spells in question are NEBS.


Assuntos
Competência Clínica , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Transtornos dos Movimentos/diagnóstico , Neurologistas , Convulsões/diagnóstico , Telemetria , Gravação de Videoteipe/métodos , Tomada de Decisão Clínica , Diagnóstico Diferencial , Feminino , Unidades Hospitalares , Humanos , Masculino , Processos Mentais , Monitorização Fisiológica/métodos , Convulsões/etiologia , Convulsões/psicologia
5.
Neurocrit Care ; 25(3): 415-423, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27033709

RESUMO

BACKGROUND: Existing studies of quantitative electroencephalography (qEEG) as a prognostic tool after cardiac arrest (CA) use methods that ignore the longitudinal pattern of qEEG data, resulting in significant information loss and precluding analysis of clinically important temporal trends. We tested the utility of group-based trajectory modeling (GBTM) for qEEG classification, focusing on the specific example of suppression ratio (SR). METHODS: We included comatose CA patients hospitalized from April 2010 to October 2014, excluding CA from trauma or neurological catastrophe. We used Persyst®v12 to generate SR trends and used semi-quantitative methods to choose appropriate sampling and averaging strategies. We used GBTM to partition SR data into different trajectories and regression associate trajectories with outcome. We derived a multivariate logistic model using clinical variables without qEEG to predict survival, then added trajectories and/or non-longitudinal SR estimates, and assessed changes in model performance. RESULTS: Overall, 289 CA patients had ≥36 h of EEG yielding 10,404 h of data (mean age 57 years, 81 % arrested out-of-hospital, 33 % shockable rhythms, 31 % overall survival, 17 % discharged to home or acute rehabilitation). We identified 4 distinct SR trajectories associated with survival (62, 26, 12, and 0 %, P < 0.0001 across groups) and CPC (35, 10, 4, and 0 %, P < 0.0001 across groups). Adding trajectories significantly improved model performance compared to adding non-longitudinal data. CONCLUSIONS: Longitudinal analysis of continuous qEEG data using GBTM provides more predictive information than analysis of qEEG at single time-points after CA.


Assuntos
Coma/fisiopatologia , Eletroencefalografia/métodos , Parada Cardíaca/fisiopatologia , Hipóxia Encefálica/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Prognóstico
6.
Clin Neurophysiol ; 114(11): 2156-64, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14580614

RESUMO

OBJECTIVE: The description and application of a new, overlap-integral comparison method and the quantification of human vs. human accuracies that can be used as goals for algorithms. METHODS: Four human experts marked ten 8 h electroencephalography (EEG) records from seizure patients. The seizures varied in origin and type, including complex partial, generalized absence, secondarily generalized and primary generalized tonic-clonic. The traditional any-overlap comparison method is used in addition to the overlap-integral method, which is sensitive to the correct placement of the seizure endpoints. RESULTS: The number of events marked by each reader ranged from 57 to 77. The average any-overlap sensitivity and false positives per hour rate are 0.92 and 0.117. The average overlap-integral correlation, sensitivity and specificity are 0.80, 0.82 and 0.9926. As expected, the correspondence between readers is high, but confounding issues resulted in overlap-integral sensitivities less than 0.5 for 10% of the records. Seven percent of the any-overlap sensitivities are less than 0.5. A comparison of the methods by record shows that the overlap-integral specificity and the any-overlap false positive rate measure different features. CONCLUSIONS: There was little variation between readers and they were essentially interchangeable. High seizure rate (many per hour), short seizure durations (<10 s) and long seizure durations (approximately 10 min) with ambiguous offsets can complicate the analysis and result in poor correlation. There may be any number of unmarked events in rigorously marked records and it may be preferable to use records from non-epilepsy patients to compute the false positive rate. The any-overlap and overlap-integral comparison methods are complementary. SIGNIFICANCE: Correlation between expert human readers can be low on some records, which will complicate testing of seizure detection algorithms.


Assuntos
Eletroencefalografia/estatística & dados numéricos , Epilepsia Parcial Complexa/diagnóstico , Epilepsia Generalizada/diagnóstico , Algoritmos , Humanos , Modelos Estatísticos , Neurologia/estatística & dados numéricos , Variações Dependentes do Observador , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA