Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
1.
Headache ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923561

RESUMO

BACKGROUND: Pain thresholds and primary headaches, including cluster headache attacks, have circadian rhythmicity. Thus, they might share a common neuronal mechanism. OBJECTIVE: This study aimed to elucidate how the modulation of nociceptive input in the brainstem changes from noon to midnight. Insights into the mechanism of these fluctuations could allow for new hypotheses about the pathophysiology of cluster headache. METHODS: This repeated measure observational study was conducted at the University Hospital Zurich from December 2019 to November 2022. Healthy adults between 18 and 85 years of age were eligible. All participants were examined at noon and midnight. We tested the pain threshold on both sides of the foreheads with quantitative sensory testing, assessed tiredness levels, and obtained high-field (7 Tesla) and high-resolution functional magnetic resonance imaging (MRI) at each visit. Functional connectivity was assessed at the two visits by performing a region-of-interest analysis. We defined nuclei in the brainstem implicated in processing nociceptive input as well as the thalamus and suprachiasmatic nucleus as the region-of-interest. RESULTS: Ten people were enrolled, and seven participants were included. First, we did not find statistically significant differences between noon and midnight of A-delta-mediated pain thresholds (median mechanical pain threshold at noon: left 9.2, right 9.2; at night: left 6.5, right 6.1). Second, after correction for a false discovery rate, we found changes in the mechanical pain sensitivity to have a statistically significant effect on changes in the functional connectivity between the left parabrachial nucleus and the suprachiasmatic nucleus (T = -40.79). CONCLUSION: The MRI data analysis suggested that brain stem nuclei and the hypothalamus modulate A-delta-mediated pain perception; however, these changes in pain perception did not lead to statistically significantly differing pain thresholds between noon and midnight. Hence, our findings shed doubt on our hypothesis that the physiologic circadian rhythmicity of pain thresholds could drive the circadian rhythmicity of cluster headache attacks.

2.
J Neurol ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38871822

RESUMO

BACKGROUND: There are limited real-world data in Switzerland examining the impact of erenumab, a fully human IgG2 monoclonal antibody targeting the calcitonin gene-related peptide (CGRP) receptor, on migraine-related quality of life. OBJECTIVE: This 18-month interim analysis of 172 patients with episodic or chronic migraine from the SQUARE study provides first prospective insights on the impact of mandatory erenumab treatment interruption, following Swiss-reimbursement requirements, in a real-world clinical setting in Switzerland. FINDINGS: Recruited patients receiving 70 or 140 mg erenumab underwent treatment interruption on average 11.2 months after therapy onset with a mean duration of 4 months. There were sustained improvements in mean monthly migraine days (MMD) and migraine disability (mMIDAS) during initial treatment with erenumab. Treatment interruption was associated with a temporary worsening of condition. Symptoms ameliorated upon therapy reuptake reaching improvements similar to pre-break within 3 months. CONCLUSIONS: Treatment interruption was associated with a temporary worsening of condition, which improved again after therapy restart.

3.
Dig Endosc ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38934243

RESUMO

OBJECTIVES: There have been significant advances in the management of large (≥20 mm) laterally spreading tumors (LSTs) or nonpedunculated colorectal polyps; however, there is a lack of clear consensus on the management of these lesions with significant geographic variability especially between Eastern and Western paradigms. We aimed to provide an international consensus to better guide management and attempt to homogenize practices. METHODS: Two experts in interventional endoscopy spearheaded an evidence-based Delphi study on behalf of the World Endoscopy Organization Colorectal Cancer Screening Committee. A steering committee comprising six members devised 51 statements, and 43 experts from 18 countries on six continents participated in a three-round voting process. The Grading of Recommendations, Assessment, Development and Evaluations tool was used to assess evidence quality and recommendation strength. Consensus was defined as ≥80% agreement (strongly agree or agree) on a 5-point Likert scale. RESULTS: Forty-two statements reached consensus after three rounds of voting. Recommendations included: three statements on training and competency; 10 statements on preresection evaluation, including optical diagnosis, classification, and staging of LSTs; 14 statements on endoscopic resection indications and technique, including statements on en bloc and piecemeal resection decision-making; seven statements on postresection evaluation; and eight statements on postresection care. CONCLUSIONS: An international expert consensus based on the current available evidence has been developed to guide the evaluation, resection, and follow-up of LSTs. This may provide guiding principles for the global management of these lesions and standardize current practices.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38705436

RESUMO

Pathological assessment of colorectal polyps is considered the current reference standard for histologic diagnosis. About 10% of polyps sent to the pathology lab are returned with the diagnosis of mucosal folds, mucosal prolapse, or normal mucosa.1,2 Two recent publications have indicated that disagreements between endoscopic optical diagnosis and the subsequent pathological diagnoses might be due to misdiagnosis in pathology.3,4 We were therefore interested in re-evaluating pathology-based diagnosis of "mucosal polyps" using expert endoscopists and computer-assisted diagnosis (CADx) evaluation.

5.
Scand J Gastroenterol ; : 1-11, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775234

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is higher after a positive fecal immunochemical test (FIT) compared to direct screening colonoscopy. OBJECTIVE: This meta-analysis evaluated how ADR, the rates of advanced adenoma detection (AADR), colorectal cancer detection (CDR), and sessile serrated lesion detection (SSLDR) are affected by different FIT positivity thresholds. METHODS: We searched MEDLINE, EMBASE, CINAHL, and EBM Reviews databases for studies reporting ADR, AADR, CDR, and SSLDR according to different FIT cut-off values in asymptomatic average-risk individuals aged 50-74 years old. Data were stratified according to sex, age, time to colonoscopy, publication year, continent, and FIT kit type. Study quality, heterogeneity, and publication bias were assessed. RESULTS: Overall, 4280 articles were retrieved and fifty-eight studies were included (277,661 FIT-positive colonoscopies; mean cecal intubation 96.3%; mean age 60.8 years; male 52.1%). Mean ADR was 56.1% (95% CI 53.4 - 58.7%), while mean AADR, CDR, and SSLDR were 27.2% (95% CI 24.4 - 30.1%), 5.3% (95% CI 4.7 - 6.0%), and 3.0% (95% CI 1.7 - 4.6%), respectively. For each 20 µg Hb/g increase in FIT cut-off level, ADR increased by 1.54% (95% CI 0.52 - 2.56%, p < 0.01), AADR by 3.90% (95% CI 2.76 - 5.05%, p < 0.01) and CDR by 1.46% (95% CI 0.66 - 2.24%, p < 0.01). Many detection rates were greater amongst males and Europeans. CONCLUSIONS: ADRs in FIT-positive colonoscopies are influenced by the adopted FIT positivity threshold, and identified targets, importantly, proved to be higher than most current societal recommendations.

7.
Endoscopy ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38657660

RESUMO

INTRODUCTION: The environmental impact of endoscopy, including small-bowel capsule endoscopy (SBCE), is a topic of growing attention and concern. This study aimed to evaluate the greenhouse gas (GHG) emissions (kgCO2) generated by an SBCE procedure. METHODS: Life cycle assessment methodology (ISO 14040) was used to evaluate three brands of SBCE device and included emissions generated by patient travel, bowel preparation, capsule examination, and video recording. A survey of 87 physicians and 120 patients was conducted to obtain data on travel, activities undertaken during the procedure, and awareness of environmental impacts. RESULTS: The capsule itself (4 g) accounted for < 6 % of the total product weight. Packaging (43-119 g) accounted for 9 %-97 % of total weight, and included deactivation magnets (5 g [4 %-6 %]) and paper instructions (11-50 g [up to 40 %]). A full SBCE procedure generated approximately 20 kgCO2, with 0.04 kgCO2 (0.2 %) attributable to the capsule itself and 18 kgCO2 (94.7 %) generated by patient travel. Capsule retrieval using a dedicated device would add 0.98 kgCO2 to the carbon footprint. Capsule deconstruction revealed materials (e. g. neodymium) that are prohibited from environmental disposal; 76 % of patients were not aware of the illegal nature of capsule disposal via wastewater, and 63 % would have been willing to retrieve it. The carbon impact of data storage and capsule reading was negligible. CONCLUSION: The carbon footprint of SBCE is mainly determined by patient travel. The capsule device itself has a relatively low carbon footprint. Given that disposal of capsule components via wastewater is illegal, retrieval of the capsule is necessary but would likely be associated with an increase in device-related emissions.

8.
Scand J Gastroenterol ; 59(5): 608-614, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38333956

RESUMO

BACKGROUND AND AIMS: Accurate polyp size estimation during colonoscopy has an impact on clinical decision-making. A laser-based virtual scale endoscope (VSE) is available to allow measuring polyp size using a virtual adaptive scale. This study evaluates video-based polyp size measurement accuracy among expert endoscopists using either VSE or visual assessment (VA) with either snare as reference size or without any reference size information. METHODS: A prospective, video-based study was conducted with 10 expert endoscopists. Video sequences from 90 polyps with known reference size (fresh specimen measured using calipers) were distributed on three different slide sets so that each slide set showed the same polyp only once with either VSE, VA or snare-based information. A slide set was randomly assigned to each endoscopist. Endoscopists were asked to provide size estimation based on video review. RESULTS: Relative accuracies for VSE, VA, and snare-based estimation were 75.1% (95% CI [71.6-78.5]), 65.0% (95% CI [59.5-70.4]) and 62.0% (95% CI [54.8-69.0]), respectively. VSE yielded significantly higher relative accuracy compared to VA (p = 0.002) and to snare (p = 0.001). A significantly lower percentage of polyps 1-5 mm were misclassified as >5 mm using VSE versus VA and snare (6.52% vs. 19.6% and 17.5%, p = 0.004) and a significantly lower percentage of polyps >5 mm were misclassified as 1-5 mm using VSE versus VA and snare (11.4% vs. 31.9% and 14.9%, p = 0.038). CONCLUSIONS: Endoscopists estimate polyp size with the highest accuracy when virtual adaptive scale information is displayed. Using a snare to assist sizing did not improve measurement accuracy compared to displaying visual information alone.


Assuntos
Pólipos do Colo , Colonoscopia , Gravação em Vídeo , Humanos , Estudos Prospectivos , Colonoscopia/métodos , Pólipos do Colo/patologia , Competência Clínica , Masculino , Feminino
9.
Gastroenterology ; 167(2): 392-399.e2, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38331204

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).


Assuntos
Inteligência Artificial , Pólipos do Colo , Colonoscopia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Colonoscopia/métodos , Pólipos do Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico , Idoso , Valor Preditivo dos Testes , Diagnóstico por Computador , Reprodutibilidade dos Testes , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Adulto
10.
Endoscopy ; 56(5): 355-363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38278158

RESUMO

BACKGROUND: Gastrointestinal (GI) endoscopy is one of healthcare's main contributors to climate change. We aimed to assess healthcare professionals' attitudes and the perceived barriers to implementation of sustainable GI endoscopy. METHODS: The LEAFGREEN web-based survey was a cross-sectional study conducted by the European Society of Gastrointestinal Endoscopy (ESGE) Green Endoscopy Working Group. The questionnaire comprised 39 questions divided into five sections (respondent demographics; climate change and sustainability beliefs; waste and resource management; single-use endoscopes and accessories; education and research). The survey was available via email to all active members of the ESGE and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) in March 2023. RESULTS: 407 respondents participated in the survey (11% response rate). Most participants (86%) agreed climate change is real and anthropogenic, but one-third did not consider GI endoscopy to be a significant contributor to climate change. Improvement in the appropriateness of endoscopic procedures (41%) and reduction in single-use accessories (34%) were considered the most important strategies to reduce the environmental impact of GI endoscopy. Respondents deemed lack of institutional support and knowledge from staff to be the main barriers to sustainable endoscopy. Strategies to reduce unnecessary GI endoscopic procedures and comparative studies of single-use versus reusable accessories were identified as research priorities. CONCLUSIONS: In this survey, ESGE and ESGENA members acknowledge climate change as a major threat to humanity. Further improvement in sustainability beliefs and professional attitudes, reduction in inappropriate GI endoscopy, and rational use of single-use accessories and endoscopes are critically required.


Assuntos
Atitude do Pessoal de Saúde , Endoscopia Gastrointestinal , Humanos , Estudos Transversais , Feminino , Masculino , Inquéritos e Questionários , Adulto , Mudança Climática , Pessoa de Meia-Idade , Conhecimentos, Atitudes e Prática em Saúde , Endoscópios Gastrointestinais
11.
Pain Pract ; 24(5): 709-716, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38251757

RESUMO

BACKGROUND: Pain in the head and the face is highly prevalent but may have changed during the past years. This study aimed to analyze changes in the prevalence of pain in the head and the face in Switzerland from 1997 to 2017. METHODS: This is a secondary analysis of data collected in the Swiss Health Surveys of 1997-2017. Included persons were 15 years and older. Besides studying demographic data, we analyze the item assessing the presence of "headache, pressure in the head, or facial pain" during the past 4 weeks. Percentages with their Wilson confidence intervals are reported for each response option of categorical variables. Moreover, we calculate the age-standardized number of persons affected by the pain. RESULTS: While 41% reported head and face pain in 1997, the proportion dropped to 31% in 2017. There was a decrease of 19.5% in women and 29.4% in men; after age standardization, the decrease was 16.5% in women and 25.4% in men. The most considerable numerical changes in the percentages of women with pain occurred in those aged 55-69 and 85 and above. In men, the changes were not limited to specific age groups. CONCLUSIONS: The proportion of people reporting headaches, pressure in the head, or facial pain has dropped in Switzerland from 1997 to 2017. However, in women, the prevalence diminished more strongly and consistently in the middle-aged and the elderly than in the young.


Assuntos
Dor Facial , Cefaleia , Humanos , Suíça/epidemiologia , Masculino , Feminino , Prevalência , Pessoa de Meia-Idade , Adulto , Idoso , Dor Facial/epidemiologia , Adulto Jovem , Adolescente , Cefaleia/epidemiologia , Idoso de 80 Anos ou mais , Inquéritos Epidemiológicos
12.
Gastrointest Endosc ; 99(2): 177-185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37500019

RESUMO

BACKGROUND AND AIMS: Video analysis has emerged as a potential strategy for performance assessment and improvement. We aimed to develop a video-based skill assessment tool for peroral endoscopic myotomy (POEM). METHODS: POEM was deconstructed into basic procedural components through video analysis by an expert panel. A modified Delphi approach and 2 validation exercises were conducted to refine the POEM assessment tool (POEMAT). Twelve assessors used the final POEMAT version to grade 10 videos. Fully crossed generalizability (G) studies investigated the contributions of assessors, endoscopists' performance, and technical elements to reliability. G coefficients below .5 were considered unreliable, between .5 and .7 as modestly reliable, and above .7 as indicative of satisfactory reliability. RESULTS: After task deconstruction, discussions, and the modified Delphi process, the final POEMAT comprised 9 technical elements. G analysis showed low variance for endoscopist performance (.8%-24.9%) and high interrater variability (range, 63.2%-90.1%). The G score was moderately reliable (≥.60) for "submucosal tunneling" and "myotomy" and satisfactorily reliable (≥.70) for "active hemostasis" and "mucosal closure." CONCLUSIONS: We developed and established initial content and response process validity evidence for the POEMAT. Future steps include appraisal of the tool using a wider range of POEM videos to establish and improve the discriminative validity of this tool.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Acalasia Esofágica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Acalasia Esofágica/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Esfíncter Esofágico Inferior
14.
Clin Gastroenterol Hepatol ; 22(3): 552-561.e4, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37871841

RESUMO

BACKGROUND & AIMS: Thermal treatment of the defect margin after endoscopic mucosal resection (EMR) of large nonpedunculated colorectal lesions reduces the recurrence rate. Both snare tip soft coagulation (STSC) and argon plasma coagulation (APC) have been used for thermal margin treatment, but there are few data directly comparing STSC with APC for this indication. METHODS: We performed a randomized 3-arm trial in 9 US centers comparing STSC with APC with no margin treatment (control) of defects after EMR of colorectal nonpedunculated lesions ≥15 mm. The primary end point was the presence of residual lesion at first follow-up. RESULTS: There were 384 patients and 414 lesions randomized, and 308 patients (80.2%) with 328 lesions completed ≥1 follow-up. The proportion of lesions with residual polyp at first follow-up was 4.6% with STSC, 9.3% with APC, and 21.4% with control subjects (no margin treatment). The odds of residual polyp at first follow-up were lower for STSC and APC when compared with control subjects (P = .001 and P = .01, respectively). The difference in odds was not significant between STSC and APC. STSC took less time to apply than APC (median, 3.35 vs 4.08 minutes; P = .019). Adverse event rates were low, with no difference between arms. CONCLUSIONS: In a randomized trial STSC and APC were each superior to no thermal margin treatment after EMR. STSC was faster to apply than APC. Because STSC also results in lower cost and plastic waste than APC (APC requires an additional device), our study supports STSC as the preferred thermal margin treatment after colorectal EMR. (Clinicaltrials.gov, Number NCT03654209.).


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Pólipos do Colo/patologia , Colonoscopia/métodos , Coagulação com Plasma de Argônio , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/etiologia , Ressecção Endoscópica de Mucosa/métodos
15.
Scand J Gastroenterol ; 59(1): 112-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37743643

RESUMO

INTRODUCTION: Serrated lesions (SLs) including traditional serrated adenomas (TSA), large hyperplastic polyps (HP) and sessile serrated lesions (SSLs) are associated with high incomplete resection rates. Margin ablation combined with EMR (EMR-T) has become routine to reduce local recurrence while cold snare polypectomy (CSP) is becoming recognized as equally effective for large SLs. Our aim was to evaluate local recurrence rates (LRR) and the use of margin ablation in preventing recurrence in a retrospective cohort study. METHODS: Patients undergoing resection of ≥15 mm colorectal SLs from 2010-2022 were identified through a pathology database and electronic medical records search. Hereditary CRC syndromes, first follow-up > 18 months or no follow-up, surgical resection were excluded. Primary outcome was LRRs (either histologic or visual) during the first 18-month follow-up. Secondary outcomes were LRRs according to size, and resection technique. RESULTS: 191 polyps in 170 patients were resected (59.8% women; mean age, 65 years). The mean size of polyps was 22.4 mm, with 107 (56.0%) ≥20 mm. 99 polyps were resected with EMR, 39 with EMR-T, and 26 with CSP. Mean first surveillance was 8.2 mo. Overall LRR was 18.8% (36/191) (16.8% for ≥20 mm, 17.9% for ≥30 mm). LRR was significantly lower after EMR-T when compared with EMR (5.1% vs. 23.2%; p = 0.013) or CSP (5.1% vs. 23.1%; p = 0.031). There was no difference in LRR between EMR without margin ablation and CSP (p = 0.987). CONCLUSION: The local recurrence rate for SLs ≥15 mm is high with 18.8% overall recurrence. EMR with thermal ablation of the margins is superior to both no ablation and CSP in reducing LRRs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Idoso , Masculino , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Estudos Retrospectivos , Adenoma/cirurgia , Adenoma/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Ressecção Endoscópica de Mucosa/métodos
16.
18.
Gastrointest Endosc ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37993062

RESUMO

BACKGROUND AND AIMS: Endocuff VisionTM has been designed to enhance mucosal visualization thereby improving detection of (pre-)malignant colorectal lesions. This multicenter, international, back-to-back, randomized colonoscopy trial compared adenoma detection rate (ADR) and adenoma miss rate (AMR) between Endocuff Vision-assisted colonoscopy (EVC) and conventional colonoscopy (CC). METHODS: Patients aged 40-75 years referred for non-immunochemical fecal occult blood test-based screening, surveillance, or diagnostic colonoscopy were included at ten hospitals and randomized into four groups: Group 1; 2xCC, Group 2; CC followed by EVC, Group 3; EVC followed CC and Group 4; 2xEVC. Primary outcomes included ADR and AMR. RESULTS: A total of 717 patients were randomized of which 661 patients (92.2%) had one and 646 (90.1%) patients had two completed back-to-back colonoscopies. EVC did not significantly improve ADR compared to CC (41.1% [95%-CI;36.1-46.3] versus 35.5% [95%-CI;30.7-40.6], respectively, P=0.125), but EVC did reduced AMR by 11.7% (29.6% [95%-CI;23.6-36.5] versus 17.9% [95%-CI;12.5-23.5], respectively, P=0.049). AMR of 2xCC compared to 2xEVC was also not significantly different (25.9% [95%-CI;19.3-33.9] versus 18.8% [95%-CI;13.9-24.8], respectively, P=0.172). Only 3.7% of the polyps missed during the first procedures had advanced pathologic features. Factors affecting risk of missing adenomas were age (P=0.002), Boston Bowel Preparation Scale (P=0.008) and region where colonoscopy was performed (P<0.001). CONCLUSIONS: Our trial shows that EVC reduces the risk of missing adenomas but does not lead to a significant improved ADR. Remarkably, 25% of adenomas are still missed during conventional colonoscopies, which is not different from miss rates reported 25 years ago; reassuringly, advanced features were only found in 3.7% of these missed lesions. TRAIL REGISTRATION NUMBER: NCT03418948.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA