Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(3)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38534529

RESUMO

The bioengineering of corneal endothelial grafts consists of seeding in vitro cultured corneal endothelial cells onto a thin, transparent, biocompatible, and sufficiently robust carrier which can withstand surgical manipulations. This is one of the most realistic alternatives to donor corneas, which are in chronic global shortage. The anterior capsule of the crystalline lens has already been identified as one of the best possible carriers, but its challenging manual preparation has limited its use. In this study, we describe a femtosecond laser cutting process of the anterior capsule of whole lenses in order to obtain capsule discs of 8 mm diameter, similar to conventional endothelial grafts. Circular marks made on the periphery of the disc indicate its orientation. Immersion in water for 3 days is sufficient to completely remove the lens epithelial cells and to enable the seeding of corneal endothelial cells, which remain viable after 27 days of culture. Therefore, this method provides a transparent, decellularized disc ready to form viable tissue engineered endothelial grafts.

2.
Br J Ophthalmol ; 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37714683

RESUMO

AIM: To investigate the interest of chromatic confocal microscopy (CCM) to characterise guttae in Fuchs endothelial corneal dystrophy (FECD). METHODS: Descemet's membranes (DM) were obtained during endothelial keratoplasty in patients with FECD and pseudophakic bullous keratopathy (PBK). They were compared with healthy samples obtained from body donation to science. Samples were fixed in 0.5% paraformaldehyde and flat mounted. Surface roughness of DMs was quantified using CCM and the AltiMap software that provided the maximum peak (Sp) and valley (Sv) heights, the mean square roughness (Rq) and the asymmetry coefficient (Ssk). RESULTS: The physiological roughness of healthy samples was characterised by an Rq of 0.12±0.05 µm, which was two times rougher than in PBK (Rq=0.06±0.03 µm), but both were still flat with a symmetrical distribution between peaks and valleys (Ssk close to 0, npeaks=nvalleys), smaller than 1 µm. In FECD, the maximum peak height was 5.10±2.40 µm, up to 5.8 and 8.3 times higher than the control and PBK, respectively. The maximum valley depth was half than the peak (2.28±0.89 µm). The surface with guttae was very rough (Rq=0.45±0.14 µm) and the Ssk=1.84± 0.43 µm, greater than 0, confirms an asymmetric surface with high peaks and low valleys (npeaks>nvalleys). Moreover, the CCM provided quantitative parameters allowing to distinguish different types of guttae from different patients. CONCLUSIONS: CCM is an innovative approach to describe and quantify different morphologies of guttae. It could be useful to analyse the different stages of FECD and define subgroups of patients.

3.
BMJ Open Ophthalmol ; 8(Suppl 2): A1, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604543

RESUMO

PURPOSE: The number of endothelial grafts precut by eye banks increases. Their shelf life is limited to a few days. We previously demonstrated the superiority of an active storage machine (ASM) over organ culture (passive) for whole corneas. AIMS: to measure endothelial viability of precut DSAEK after 3 or 10 days of storage in our ASM in a preclinical study. METHODS: Human pairs of corneas were included. The endothelial cell density (ECD in cells/mm2), and central corneal thickness (CCT in µm) were measured to ensure their initial intra pair comparability. After deswelling (CorneaJet, Eurobio) grafts preparation was performed by cutting the anterior stroma with a Moria linear microkeratome and keeping the anterior lamellae attached during storage. After randomization, one cornea was kept in the corneajet bottle (CJ) and the other was inserted into the ASM allowing a renewal or storage medium (CorneaMax, Eurobio) at 2.6 µL/min with 21 mmHg of pressure in the endothelial chamber. Both group of corneas were stored for 3 or 10 days at 31°C. The final viable ECD (vECD) was determined using the triple staining with Hoechst-Ethidium-Calcein-AM by an independent experimenter in a masked fashion. RESULTS: Initial ECDs were comparable: 2595±878 in ASM versus 2654±954 cells/mm2 in CJ for the 3-days period (n=5 pairs) and 2416±712 in ASM versus 2492±764 cells/mm2 in CJ for the 10-period (n=5 pairs). CCTs were also comparable. The anterior lamellae stayed attached in either the ASM or CJ. vECD was significantly higher in ASM than in CJ with respectively 2062±695 cells/mm2 versus 1632±633 cells/mm2 after 3 days either a cell loss of 20.5% and 38.5% respectively (p=0.0062) and 1082±649 versus 935±691 cells/mm2 for the 10-day period either a cell loss of 132% and 164% respectively (p=0.005). Grafts thickness did not differ after 3 days 219±25 µm in ASM versus 182±39 µm (p=0.063) or 10 days respectively 221±58 µm versus 189±48 µm (p=0.06). CONCLUSION: The storage of precut DSAEKs into the ASM allows a better preservation of grafts without use on deswelling storage medium. Nevertheless, the cell loss remains high after 10 days, suggesting a significant cell stress.


Assuntos
Córnea , Bancos de Olhos , Humanos , Estudos de Viabilidade , Córnea/cirurgia , Etídio
4.
BMJ Open Ophthalmol ; 8(Suppl 2): A1, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604553

RESUMO

PURPOSE: The number of endothelial grafts precut by eye banks increases. Their shelf life is limited to a few days. We previously demonstrated the superiority of an active storage machine (ASM) over organ culture (passive) for whole corneas. AIMS: To measure the endothelial viability of pre-dissected DMEK after 3 and 10 days of storage in our ASM in a preclinical study. METHODS: Pairs of human corneas were included. The endothelial cell density (ECD in cells/mm2), thickness and transparency of corneas were measured before graft preparation. Descemet's membrane (DM) was peeled using the no-touch technique leaving the graft attached to the center of the cornea (on approx. 1mm2). After randomization, one cornea was kept in organ culture (OC) and the other in the ASM (21 mmHg, 2.6 µL/min) in the same medium (CorneaMax, Eurobio). The final viable ECD was determined using the triple staining with Hoechst-Ethidium-Calcein-AM. In addition, the expression of CD166 and NCAM (lateral membranes), ZO-1 (apical junctions), Na+/K+ ATPase (endothelial pump function) and COX-IV (mitochondrial content) was studied by immunostaining to characterize endothelial cells after the storage. RESULTS: Initial ECDs were comparable: 2185±232 cells/mm2 in the ASM versus 2276±328 in OC for the 3-day period and 2680±416 cells/mm2 in the ASM versus 2644±420 in OC for the 10-day period. The DMs did not fold back in either BR or OC. The viable ECD did not differ significantly between the ASM and OC for either storage period: 2378±501 (ASM) versus 2342±503 (OC) for the 3-day period (n=8 pairs and p=0.624) and 2482±288 (ASM) versus 2579±315 (OC) for the 10-day period (n=5 pairs and p=0.176). Corneas were more transparent and thinner in the ASM than in OC after 3 days (916±86 versus 1193±136µm, p=0.0001) and 10 days (957±128 versus 1220±105µm, p=0.0625). The functional and structural markers studied were expressed in both groups after 3 and 10 days, some better preserved in the ASM. CONCLUSION: The storage of precut DMEKs is possible in ASM and OC for at least 10 days. Interestingly, a pre-dissected endothelium continues to partially exert its pump function into the ASM. In practice, this could allow the stroma to be used for DALK without further deswelling. In addition to improving the storage of whole grafts, the ASM allows the storage of precut DMEKs for up to 10 days with excellent endothelial survival.


Assuntos
Córnea , Células Endoteliais , Humanos , Estudos de Viabilidade , Etídio , Bancos de Olhos , ATPase Trocadora de Sódio-Potássio
5.
BMJ Open Ophthalmol ; 8(Suppl 2): A13-A14, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604554

RESUMO

PURPOSE: Human corneas preserved in bioreactor (BR) are characterized by not only a better endothelial viability, but also a more differentiated and stratified epithelium compared to corneas preserved in organoculture. By using corneal preservation in BR, we aimed to analyze the respective contribution of corneal (C), limbal (L), and conjunctival (Conj) epithelia in corneal epithelial regeneration. METHODS: Five pairs of corneas from body donation to Science were used with a death-to-collection time <20 hours. A 3- to 5-mm-wide conjunctival flange was kept intact. Five patterns were set up by complete mechanical removal of 1, 2, or 3 epithelia (-): C-L+Conj+, C-L-Conj+, C-L+Conj-, C+L-Conj-, C-L-Conj- (control) (n=2 for each pattern). The L epithelia was destroyed by scraping and thermocoagulation. Corneas were then kept in BR (21mmHg, 2.5µl/min of Corneamax Eurobio, 31°C) for 3 weeks to allow epithelial regeneration. The epithelium was then analyzed using immunofluorescence (IF) on flat mounted cornea by targeting CK12 (corneal epithelium) and CK15 (limbal epithelium). Cell nuclei were counterstained with DAPI. Corneal transparency was quantified using a transparometer. RESULTS: No epithelium was reconstituted in the C-L-Conj- control group. In the other 4 models including the C-L-Conj+ group, the cornea was transparent and covered by a pluristratified corneal epithelium, characterized by CK12 expression. CONCLUSION: In this BR model, conjunctival epithelial cells alone allowed the regeneration of a typical corneal epithelium whereas corneal epithelium was able to migrate to the limbus and conjunctiva. We hypothesize that all 3 ocular surface epithelia contain stem cells or progenitors able to migrate throughout the cornea and restore the corneal epithelium independently of each other. The main difference between our ex vivo model and in vivo situation is the absence of neovascularization. This suggests that the main cause of limbic insufficiency is due to the loss of the anti-angiogenic barrier rather than the loss of limbic stem cells.


Assuntos
Epitélio Corneano , Anormalidades do Olho , Humanos , Córnea , Túnica Conjuntiva , Reatores Biológicos , Regeneração
6.
BMJ Open Ophthalmol ; 8(Suppl 2): A2, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604563

RESUMO

PURPOSE: The Active Storage Machine (ASM), designed by Sincler (a company of group Laboratoires Théa) for eyebanks, will be used for long term donor corneas preservation at 31°C before transplantation. In this device, the endothelial cell density (ECD) counting is expected to be performed non-invasively throughout the storage, thus without changing the storage medium nor handling the cornea. To meet these constraints, specular microscopy (SM), also used for cold storage was selected, instead of the standard light transmission microscopy (LTM-NaCl) used in eye banks storing corneas in organ culture at 31-34°C. The purpose of this study is to compare both imaging methods for ECD measurement of corneas preserved in ASM. METHODS: Five human corneas from body donation to Science were preserved in a prototype ASM with 35mmHg in the endothelial chamber, 2.5µl/min of Corneamax® (Eurobio, France) at 31°C for 5 days. The endothelium of the cornea was imaged through the ASM window using the CellChek® D+ SM (Konan Medical, California, United-States) equipped with an add on device at customized stage. The cornea was then immediately removed from the ASM and prepared for standard endothelial assessment (dilation of the intercellular spaces using 0.9% NaCl and light transmission imaging). Finally, the endothelium was stained with alizarine red and trypan blue and observed again with the same microscope, to determine ECD using the referenced method up to now. For each cornea and each observation method, 5 images were acquired: 1 central and 4 paracentral. The SM images were counted with the Konan software. The LTM-NaCl and 'Alizarin Red' counts were performed with a dedicated plugin of ImageJ after microscope calibration. RESULTS: The means ± SD of the ECD calculated for SM, LTM-NaCl and 'Alizarine' images were respectively of 2314 ± 537, 2243 ± 506 and 2354 ± 543 cells/mm2. There was no significant difference between the 3 methods (ANOVA one-way, p-value = 0.1066). The percentage error was -1.7% +/- 3.3% for SM and -4.7 +/- 4.0% for light transmission microscopy. CONCLUSION: Quality control of the endothelium of corneas stored in ASM can be performed non-invasively with a standard eye bank SM. The ECD measured by SM does not differ from that measured by the conventional microscopy technique used until now in organoculture.


Assuntos
Microscopia , Cloreto de Sódio , Humanos , Antraquinonas , Córnea , Solução Salina
7.
BMJ Open Ophthalmol ; 8(Suppl 2): A15-A16, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37604568

RESUMO

INTRODUCTION: The quality of the endothelial graft is critical to the success of DMEK and to the survival time of the graft. The peeling technique, preservation method, and skill level of graft preparers need to be evaluated and validated. The most reliable method of evaluation is the viability test based on a triple staining of Hoechst- Ethidium-Calcein AM (H-E-C) which allows the determination of the total number of viable cells on the graft. However, this test has some shortcomings for DMEK grafts: 1) The undesirable fluorescence of the Calcein AM stain prevents accurate viability analysis, especially in cases where the graft is attached to the cornea for preservation; 2) Incompatibility with immunofluorescence (IF) that could provide additional information. The objective of this study is to develop technical tricks to overcome these drawbacks. METHODS: Two strategies were employed to improve Calcein AM staining: 1. Increase the specific fluorescence intensity by changing the diluent and the concentration of Calcein AM; 2. Decrease undesired fluorescence from keratocytes by adding Trypan Blue (BT). In order to combine the IF after the HEC test, an extension wash in PBS was performed. RESULTS: Calcein AM at 4µM diluted in OptiMEM increased fluorescence intensity 3-fold (p=0.0017, n=5) compared with conventional staining at 2µM in PBS. BT decreased the undesired fluorescence of Calcein and thus optimized count variability between different operators by 42% (p=0.0027, n=10) and saved 40% (p=0.0002, n=10) of count time. To perform IF after HEC, prolonged washing in PBS is an effective method to remove residual Calcein fluorescence and allows release of the FITC/Alexa 488 filter. CONCLUSION: This study provides effective technical tips for optimizing the endothelial viability assay using Calcein AM and for performing IF after the viability assay.


Assuntos
Corantes Fluorescentes , Coloração e Rotulagem , Fluoresceínas , Etídio , Transplantes , Bioensaio
8.
Br J Ophthalmol ; 107(2): 181-186, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34426402

RESUMO

BACKGROUND/AIM: Rejection is the main cause of graft failure after penetrating keratoplasty (PK). Its prevention by repeated instillation of steroid eye-drops has not evolved in decades. Poor adherence and discontinuous nature of eye-drop treatment may explain some PK failures. In a rabbit model, we previously demonstrated that a subconjunctival dexamethasone implant was well tolerated and prevented rejection efficiently in the first 5-6 weeks. This clinical trial investigates its tolerance and safety after PK. METHODS: Single-centre, phase II non-randomised tolerance and safety pilot study (NCT02834260). Designed to analyse the risk of elevated intraocular pressure (IOP), discomfort and resorption time. Fourteen patients with a low rejection risk indication of PK were enrolled between January 2017 and August 2018. The implant was injected in the 12 o'clock position, 5 mm from the limbus, at the end of PK. A steroid eye-drop treatment was planned when implant resorption was complete. Patients were monitored regularly for 12 months: IOP (main outcome measure at 1 month), discomfort and redness scores, implant status, rejection episode and central corneal thickness by optical coherence tomography. An independent data safety monitoring committee verified safety aspects. RESULTS: No increase in IOP or other adverse event related to the implant was observed. Average resorption time was 6 weeks. The switch to steroid eye-drops was uneventful. One patient, included despite preoperative corneal neovascularisation (unintended protocol deviation) experienced a rejection. CONCLUSIONS: This is the first proof of concept that dropless immunosuppression is possible after low rejection risk PK. TRIAL REGISTRATION NUMBER: NCT02834260.


Assuntos
Dexametasona , Ceratoplastia Penetrante , Dexametasona/administração & dosagem , Rejeição de Enxerto/prevenção & controle , Ceratoplastia Penetrante/efeitos adversos , Ceratoplastia Penetrante/métodos , Projetos Piloto , Humanos , Implantes de Medicamento/efeitos adversos
9.
Micromachines (Basel) ; 13(12)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36557426

RESUMO

The use of ultrafast laser pulses for eye anterior segment surgery has seen a tremendous growth of interest as the technique has revolutionized the field, from the treatment of myopia, hyperopia, and presbyopia in the cornea to laser-assisted cataract surgery of the crystalline lens. For the latter, a comprehensive understanding of the laser-tissue interaction has yet to be achieved, mainly because of the challenge of observing the interaction zone in situ with sufficient spatial and temporal resolution in the complex and multi-layered tissue of the crystalline lens. We report here on the dedicated characterization results of the laser-tissue interaction zone in the ex vivo porcine lens using three different methods: in situ and real-time microscopy, wide-field optical imaging, and phase-contrast microscopy of the histological cross sections. These complementary approaches together revealed new physical and biological consequences of laser irradiation: a low-energy interaction regime (pulse energy below ~1 µJ) with very limited cavitation effects and a stronger photo-disruption regime (pulse energy above 1 µJ) with a long cavitation duration from seconds to minutes, resulting in elongated spots. These advances in the understanding of the ultrafast laser's interactions with the lens are of the utmost importance for the preparation of the next-generation treatments that will be applied to the lens.

10.
Digit Health ; 8: 20552076221121155, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36133001

RESUMO

Objectives: Corneal transplantation is the most common transplant worldwide and its success critically depends on the management of corneal graft rejection through topical steroid therapy during the first 12 months after surgery. There is currently no published data on adherence after keratoplasty. This pilot study aims to explore the adherence to topical steroid after penetrating keratoplasty using a smart electronic device. Methods: Thirty patients undergoing penetrating keratoplasty were included to evaluate the adherence to topical dexamethasone medication for 12 months after surgery. Patients received the usual post-transplantation treatment (topical dexamethasone) and follow-up after surgery (day 15, months 1, 2, 3, 4, 5, 6, 9, and 12). Adherence to treatment was monitored using the KaliJAR device (Kali Care, Santa Clara, CA, USA), which recorded the number of single-dose units (SDU) discarded. At control visits, data recorded by the device were compared to the manually count of SDU. Adherence ratio and individual adherence curve were explored for all patients. Results: Data from 27 patients showed a high agreement between adherence ratio calculated based on the device data and obtained from manual counting of the discarded SDU (intraclass coefficient correlation of 0.87 [95% CI: 0.738-0.938]). Mean adherence to the treatment over the 12-month study period was 95.2 ± 4%. Conclusions: Adherence to topical dexamethasone for 12 months after corneal transplantation was high. The connected device was able to record accurately the discarded SDU. This approach would be a particular interest in the early identification and personalized follow-up of poorly adherent patients.

11.
PLoS Med ; 19(3): e1003922, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35231027

RESUMO

BACKGROUND: The risk of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) transmission through corneal graft is an ongoing debate and leads to strict restrictions in corneas procurement, leading to a major decrease in eye banking activity. The aims of this study are to specifically assess the capacity of human cornea to be infected by SARS-CoV-2 and promote its replication ex vivo, and to evaluate the real-life risk of corneal contamination by detecting SARS-CoV-2 RNA in corneas retrieved in donors diagnosed with Coronavirus Disease 2019 (COVID-19) and nonaffected donors. METHODS AND FINDINGS: To assess the capacity of human cornea to be infected by SARS-CoV-2, the expression pattern of SARS-CoV-2 receptor angiotensin-converting enzyme 2 (ACE-2) and activators TMPRSS2 and Cathepsins B and L in ocular surface tissues from nonaffected donors was explored by immunohistochemistry (n = 10 corneas, 78 ± 11 years, 40% female) and qPCR (n = 5 corneas, 80 ± 12 years, 40% female). Additionally, 5 freshly excised corneas (80 ± 12 years, 40% female) were infected ex vivo with highly concentrated SARS-CoV-2 solution (106 median tissue culture infectious dose (TCID50)/mL). Viral RNA was extracted from tissues and culture media and quantified by reverse transcription quantitative PCR (RT-qPCR) (viral RNA copies) 30 minutes (H0) and 24 hours (H24) after infection. To assess the risk of corneal contamination by SARS-CoV-2, viral RNA was tested by RT-qPCR (Ct value) in both corneas and organ culture media from 14 donors diagnosed with COVID-19 (74 ± 10 years, 29% female) and 26 healthy donors (79 ± 13 years, 57% female), and in organ culture media only from 133 consecutive nonaffected donors from 2 eye banks (73 ± 13 years, 29% female). The expression of receptor and activators was variable among samples at both protein and mRNA level. Based on immunohistochemistry findings, ACE-2 was localized mainly in the most superficial epithelial cells of peripheral cornea, limbus, and conjunctiva, whereas TMPRSS2 was mostly expressed in all layers of bulbar conjunctiva. A significant increase in total and positive strands of IP4 RNA sequence (RdRp viral gene) was observed from 30 minutes to 24 hours postinfection in central cornea (1.1 × 108 [95% CI: 6.4 × 107 to 2.4 × 108] to 3.0 × 109 [1.4 × 109 to 5.3 × 109], p = 0.0039 and 2.2 × 107 [1.4 × 107 to 3.6 × 107] to 5.1 × 107 [2.9 × 107 to 7.5 × 107], p = 0.0117, respectively) and in corneoscleral rim (4.5 × 109 [2.7 × 109 to 9.6 × 109] to 3.9 × 1010 [2.6 × 1010 to 4.4 × 1010], p = 0.0039 and 3.1 × 108 [1.2 × 108 to 5.3 × 108] to 7.8 × 108 [3.9 × 108 to 9.9 × 108], p = 0.0391, respectively). Viral RNA copies in ex vivo corneas were highly variable from one donor to another. Finally, viral RNA was detected in 3 out of 28 corneas (11%) from donors diagnosed with COVID-19. All samples from the 159 nonaffected donors were negative for SARS-CoV-2 RNA. The main limitation of this study relates to the limited sample size, due to limited access to donors diagnosed with COVID-19 and concomitant decrease in the procurement corneas from nonaffected donors. CONCLUSIONS: In this study, we observed the expression of SARS-CoV-2 receptors and activators at the human ocular surface and a variable increase in viral RNA copies 24 hours after experimental infection of freshly excised human corneas. We also found viral RNA only in a very limited percentage of donors with positive nasopharyngeal PCR. The low rate of positivity in donors diagnosed with COVID-19 calls into question the utility of donor selection algorithms. TRIAL REGISTRATION: Agence de la Biomédecine, PFS-20-011 https://www.agence-biomedecine.fr/.


Assuntos
COVID-19/complicações , Córnea/virologia , Doenças da Córnea/virologia , Infecções Oculares Virais/virologia , SARS-CoV-2/fisiologia , Adulto , Idoso , Enzima de Conversão de Angiotensina 2/metabolismo , Animais , Catepsinas/metabolismo , Chlorocebus aethiops , Córnea/metabolismo , Meios de Cultura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Cultura de Órgãos , RNA Viral/metabolismo , Receptores de Coronavírus/metabolismo , Serina Endopeptidases/metabolismo , Células Vero , Replicação Viral
12.
Br J Ophthalmol ; 106(3): 312-318, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33243832

RESUMO

OBJECTIVES: To assess to which extent the COVID-19 pandemic affected corneal transplantation by virtue of donor selection algorithms in different European countries. DESIGN: Survey. SETTING: 110 eye banks in 26 European countries. PARTICIPANTS: 64 eye banks covering 95% of European corneal transplantation activity. INTERVENTIONS: A questionnaire listing the number of corneas procured and distributed from February to May 2018-2020 was circulated to eye banks. MAIN OUTCOME MEASURES: The primary outcome was the number of corneal procurements. Additional outcomes were national algorithms for donor selection, classified according to their stringency (donors with COVID-19 history, suspected for COVID-19, asymptomatic, PCR testing) and the pandemic severity in each country. We calculated Spearman's correlation coefficient to determine, two by two, the relationship between the 3-month decline in eye banking activity (procurement), the stringency of donor selection algorithm and the grading of pandemic severity (cases and deaths). A partial correlation was run to determine the relationship between decline and stringency while controlling for pandemic severity. RESULTS: Procurements decreased by 38%, 68% and 41%, respectively, in March, April and May 2020 compared with the mean of the previous 2 years, while grafts decreased, respectively, by 28%, 68% and 56% corresponding to 3866 untreated patients in 3 months. Significant disparities between countries and the decrease in activity correlated with stringency in donor selection independent of pandemic severity. CONCLUSIONS: Our data demonstrate significant differences between countries regarding donor screening algorithms based on precautionary principles and, consequently, a decrease in the donor pool, already constrained by a long list of contraindications. Fundamental studies are needed to determine the risk of SARS-CoV-2 transmission by corneal transplantation and guide evidence-based recommendations for donor selection to justify their substantial medical and economic impact.


Assuntos
COVID-19 , Córnea , Seleção do Doador , Doadores de Tecidos , COVID-19/epidemiologia , Transplante de Córnea , Europa (Continente)/epidemiologia , Bancos de Olhos , Humanos , Pandemias , Doadores de Tecidos/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA