Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Med Tekh ; (4): 24-9, 2005.
Artigo em Russo | MEDLINE | ID: mdl-16144261

RESUMO

The history of the auscultation method of arterial pressure (AP) measurement dates back to more than century ago. Nevertheless, the problem of the accuracy of measurement is still on the agenda. Standards of the accuracy of measurements and data processing are subjects of regular revision and update. The accuracy and reliability of AP monitoring in complex clinical cases are competitive advantages important for manufacturers of medical monitors. A new Triton ElectronicS module for AP measurements based on original technology and results of its testing are considered in this work. An original algorithm of the module operation provides an opportunity for more accurate and convenient monitoring, particularly in case of disordered hemodynamics.


Assuntos
Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea , Artérias/fisiologia , Humanos , Oscilometria/instrumentação , Reprodutibilidade dos Testes
2.
Bioelectromagnetics ; 17(4): 312-21, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8891190

RESUMO

The effect of millimeter waves (MMWs) on the genome conformational state (GCS) of E. coli AB1157 cells was studied by the method of anomalous viscosity time dependencies (AVTD) in the frequency range of 51.64-51.85 GHz. The 51.755 GHz resonance frequency of the cell reaction to MMWs did not depend on power density (PD) in the range from 10(-19) to 3 x 10(-3) W/cm2. The half-width of the resonant reaction of cells showed a sigmoid dependence on PD, changing from 3 MHz to 100 MHz. The PD dependence of the half-width had the same shape for different concentrations of exposed cells (4 x 10(7) and 4 x 10(8) cells/ml), whereas the magnitude of the 51.755 GHz resonance effect differed significantly and depended on the PD of MMW exposure. Sharp narrowing of the 51.755 GHz resonance in the PD range from 10(-4) to 10(-7) W/cm2 was followed by an emergence of new resonance frequencies. The PD dependence of the MMW effect at one of these resonance frequencies (51.674 GHz) differed markedly from the corresponding dependence at the 51.755 GHz resonance, the power window occurring in the range from 10(-16) to 10(-8) W/cm2. The results obtained were explained in the framework of a model of electron-conformational interactions. The frequency-time parameters of this model appeared to be in good agreement with experimental data.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Escherichia coli/genética , Proteínas de Bactérias/química , DNA Bacteriano/química , DNA Bacteriano/efeitos dos fármacos , DNA Bacteriano/genética , Escherichia coli/química , Escherichia coli/efeitos dos fármacos , Etídio/farmacologia , Genoma Bacteriano , Substâncias Intercalantes/farmacologia , Conformação de Ácido Nucleico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA