Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 69(7): 1026-35, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17530701

RESUMO

OBJECTIVE: Evaluate the performance and safety of the FiberNet Embolic Protection System during carotid artery intervention. BACKGROUND: Carotid Angioplasty and Stenting (CAS) can be proposed to treat the majority of carotid stenoses. Brain embolization takes place and routine use of Embolic Protection Devices (EPD) is warranted. Many EPDs have significant limitations, which may be addressed by a new EPD, the FiberNet (Lumen Biomedical, Plymouth, MN). METHODS: The system consists of a 3-dimensional expandable filter made of fibers, which expand radially, mounted onto a 0.014'' wire and retrieval catheter. FiberNet can capture particles as small as 40 microm without compromising flow. RESULTS: 35 lesions treated in 34 patients. Male 67.6%. Age: 71.4 +/- 8.8 (50-85). Average stenosis 84.5% +/- 7.9 (70-99). 29.4% were symptomatic. Technical success: 34/35 (97%). No stroke or death within 30 days. Neurological events: two permanent amaurosis, one amaurosis fugax. All samples visually contained significant amounts of emboli. The mean surface area of debris caught was 63.8 mm(2) (37.7-107.5). Comparisons were made with other EPDs. The mean surface area of debris caught was 12.2 mm(2) (2.7-34.3). No changes were noted in CT/MRI at 30-day post procedure. CONCLUSION: The first human use of this new novel EPD in carotid artery stenting is encouraging. The FiberNet was easy to use and confirmed the ability to capture particles less than 100 microm. The feasibility of the FiberNet has been demonstrated. Additional patients will demonstrate the overall safety and efficacy of this new EPD device.


Assuntos
Angioplastia com Balão/instrumentação , Estenose das Carótidas/terapia , Filtração/instrumentação , Embolia Intracraniana/prevenção & controle , Stents , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/complicações , Estenose das Carótidas/patologia , Estenose das Carótidas/fisiopatologia , Circulação Cerebrovascular , Remoção de Dispositivo , Estudos de Viabilidade , Feminino , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/patologia , Embolia Intracraniana/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA