Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Prenat Diagn ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877305

RESUMO

OBJECTIVE: To compare the occurrence of fetal bradycardia in open versus fetoscopic fetal spina bifida surgery. METHODS: This is a single-institution retrospective cohort study of patients undergoing open (n = 25) or fetoscopic (n = 26) spina bifida repair between 2017 and 2022. From October 2017 to June 2020, spina bifida repairs were performed via an open classical hysterotomy, and from November 2020 to June 2022 fetoscopic repairs were performed following transition to this technique. Fetal heart rate (FHR) in beats per minute (bpm) was recorded via echocardiography every 15 min during the procedure. Cohort characteristics, fetal bradycardia and maternal physiologic parameters were compared between the groups. RESULTS: Fetuses undergoing an open repair more frequently developed bradycardia defined as <110 bpm (32% vs. 3.8%, p = 0.008), and a trend was observed for FHR decreases more than 25 bpm from baseline (20% vs. 3.8%, p = 0.073). Profound bradycardia less than 80 bpm was rare, occurring in only three operations (two in open, one in fetoscopic repair) with two fetuses (one in each group) requiring emergency cesarean delivery. CONCLUSION: When compared to open fetal surgery, fetal bradycardia occurred less frequently in fetoscopic surgery despite a significantly greater anesthetic exposure and the use of the intraamniotic carbon dioxide insufflation.

2.
Fetal Diagn Ther ; : 1-7, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38740011

RESUMO

INTRODUCTION: Fetal thoracoamniotic shunts are common lifesaving interventions but frequently require replacement. Needle fetal thoracoscopy is a technique that uses standard thoracoamniotic shunt introducer sheaths to permit direct visualization and even instrument manipulation during shunt deployment to facilitate optimal positioning and primary shunt function in the most challenging cases. CASE PRESENTATION: In this study, 5 patients who underwent needle fetal thoracoscopy-assisted thoracoamniotic shunt placement were reviewed. Three patients with large, macrocystic congenital pulmonary airway malformations (CPAMs) with evidence of worsening mediastinal shift and/or hydrops and 2 patients with large chylothorax with fetal hydrops were treated. Four cases had previous shunts that failed due to poor sonographic visualization during initial placement, cyst septations, shunt obstruction, or dislodgment. Needle fetal thoracoscopy was used to disrupt cyst walls and septations, clear hematoma, and confirm the optimal initial position of the shunt. In this series, 1 severe CPAM patient with a short cervix developed preterm labor postoperatively resulting in neonatal demise. The remaining 4 patients experienced resolution of hydrops and progressed to successful delivery with excellent neonatal outcomes. CONCLUSION: Needle fetal thoracoscopy is a procedure that may be selectively deployed in challenging thoracoamniotic shunt cases impacted by recurrent failure, poor sonographic windows, and challenging fetal positioning.

3.
AJP Rep ; 13(4): e89-e93, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38090535

RESUMO

Fetal airway obstruction in one twin of a diamniotic pregnancy presents unique challenges. Very few cases of ex-utero-intrapartum-treatment (EXIT) procedures for twin pregnancy have been reported and only in dichorionic pregnancies. We report a singular methodology for EXIT-to-airway procedures in two pregnancies involving monochorionic and dichorionic twins. Two cases of EXIT-to-airway in twin pregnancies were performed in 2018 and 2019 at a regional fetal treatment center. Case 1 involved a giant cervical teratoma in a monochorionic-diamniotic twin pregnancy with preterm labor at 29 weeks. Case 2 involved a dichorionic-diamniotic pregnancy with a large cervical lymphatic malformation with preterm labor at 36 weeks. In each case, the polyhydramnios caused the affected twin's amniotic sac to be the presenting sac for the surgical approach. Bronchoscopy and successful intubation was completed after 22 and 10 minutes of uteroplacental bypass, respectively. The bystander twins were delivered second without intubation and resuscitated without perinatal distress. EXIT-to-airway appears to be a reasonable option for twins including monochorionic pregnancies, via delivery of the affected twin first followed by delivery of the bystander twin. Thoughtful preparation and counseling by an experienced multidisciplinary team permits an EXIT-to-airway approach for twin pregnancies even in an emergent setting.

4.
JACC Case Rep ; 2(7): 987-990, 2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34317399

RESUMO

We report the unique case of a patient who recovered cardiac function despite a history of doxorubicin-induced cardiomyopathy, chest radiation therapy, high dose chemotherapy post-allogeneic stem cell transplant, and triplet pregnancy. Data are sparse on doxorubicin-induced cardiomyopathy in pregnant patients, calling for further studies to help formulate management or surveillance recommendations. (Level of Difficulty: Advanced.).

5.
Am J Orthop (Belle Mead NJ) ; 43(12): E304-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25490017

RESUMO

There is concern regarding elevated metal ion levels in the blood during pregnancy and the potential fetal effects in women with metal-on-metal (MOM) implants. We obtained maternal and umbilical cord blood samples from 3 patients with a MOM hip arthroplasty and 7 control subjects without any metallic implants. Serum metal ion levels including chromium, cobalt, titanium, and nickel were tested using high-resolution sector-field inductively-coupled plasma-mass spectrometry. Mothers with MOM-bearing implants had significantly elevated levels of serum cobalt and chromium compared with control-group mothers, and umbilical cord blood from mothers with MOM implants also had significantly higher serum metal ion levels compared with control-group mothers. The results of this study show that circulating serum levels of metal ion degradation products from MOM bearings cross the placenta and expose the fetus to metal ions. However, the placenta exerts a modulatory effect on cord blood, resulting in decreased levels compared with maternal samples (approximately 15% of maternal chromium and 50% of maternal cobalt). Physicians and women of child-bearing age should be aware of this potential effect when considering the use of MOM-bearing implants.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Metais/sangue , Falha de Prótese , Adulto , Cromo/sangue , Cobalto/sangue , Feminino , Sangue Fetal , Humanos , Recém-Nascido , Níquel/sangue , Placenta/fisiologia , Gravidez , Estudos Prospectivos , Desenho de Prótese , Titânio/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA