Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Respir Med Res ; 84: 101028, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37683442

RESUMO

BACKGROUND: The ETAPES program is a national telemedicine experiment conducted in France between 2018 and 2023 to investigate whether home non-invasive ventilation (NIV) telemonitoring improves healthcare pathways in patients with chronic respiratory failure (CRF) and impacts healthcare organization. The program provides a combination of therapeutic education and NIV telemonitoring with data processed by an algorithm generating alerts. The TELVENT study objective was to analyze the evolution of ventilation quality in patients included in the ETAPES program. METHODS: Multicentric cohort study on patients undergoing long-term NIV included in the ETAPES program between September 2018 and December 2020 and who did not refuse the use of their data for this research. Data were obtained from homecare provider databases. The primary endpoint was to attain successful NIV treatment, which was determined by a combination of daily NIV usage for > 4 h per day, low leaks, and a low apnea-hypopnea index (AHI) identified by the NIV device. Respiratory disability was assessed using the DIRECT questionnaire. RESULTS: 329 patients were included in the study of which 145 had COPD and 83 had started NIV and ETAPES within one-month delay. Approximately 25% of patients did not achieve the criteria for successful NIV at ETAPES entry. The proportion of patients with successful NIV treatment increased to 86.8% at six months (p = 0.003, Cochran-Armitage trend test) regardless of NIV history and continued to increase at 12 months in newly equipped NIV patients (93.8%, at month 12, p = 0.0026 for trend test). Over time, a significant increase in NIV use and compliance was observed, while AHI significantly decreased in the overall population. No significant decrease was observed for non-intentional leaks. Approximately 4.9 alerts were generated per patient per 6 months. Their number and type (low NIV use, high AHI or leaks) differed among patients based on their NIV history. Respiratory disability score decreased over time compared with baseline. CONCLUSION: The TELVENT study highlights the importance of remote NIV monitoring to rapidly identify patients with unsuccessful ventilation. The combination of remote monitoring and therapeutic education may improve the quality of home NIV, especially in the first months of treatment.


Assuntos
Acidose Respiratória , Ventilação não Invasiva , Insuficiência Respiratória , Humanos , Ventilação não Invasiva/efeitos adversos , Estudos de Coortes , Insuficiência Respiratória/terapia , Insuficiência Respiratória/etiologia , Pulmão , Acidose Respiratória/etiologia
2.
BMJ Open Respir Res ; 8(1)2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34088727

RESUMO

BACKGROUND: Whereas first-line bronchial artery embolisation (BAE) is considered standard of care for the management of severe haemoptysis, it is unknown whether this approach is warranted for non-severe haemoptysis. RESEARCH QUESTION: To assess the efficacy on bleeding control and the safety of first-line BAE in non-severe haemoptysis of mild abundance. STUDY DESIGN AND METHODS: This multicentre, randomised controlled open-label trial enrolled adult patients without major comorbid condition and having mild haemoptysis (onset <72 hours, 100-200 mL estimated bleeding amount), related to a systemic arterial mechanism. Patients were randomly assigned (1:1) to BAE associated with medical therapy or to medical therapy alone. RESULTS: Bleeding recurrence at day 30 after randomisation (primary outcome) occurred in 4 (11.8%) of 34 patients in the BAE strategy and 17 (44.7%) of 38 patients in the medical strategy (difference -33%; 95% CI -13.8% to -52.1%, p=0.002). The 90-day bleeding recurrence-free survival rates were 91.2% (95% CI 75.1% to 97.1%) and 60.2% (95% CI 42.9% to 73.8%), respectively (HR=0.19, 95% CI 0.05 to 0.67, p=0.01). No death occurred during follow-up and no bleeding recurrence needed surgery.Four adverse events (one major with systemic emboli) occurred during hospitalisation, all in the BAE strategy (11.8% vs 0%; difference 11.8%, 95% CI 0.9 to 22.6, p=0.045); all eventually resolved. CONCLUSION: In non-severe haemoptysis of mild abundance, BAE associated with medical therapy had a superior efficacy for preventing bleeding recurrences at 30 and 90 days, as compared with medical therapy alone. However, it was associated with a higher rate of adverse events. TRIAL REGISTRATION NUMBER: NCT01278199.


Assuntos
Artérias Brônquicas , Embolização Terapêutica , Adulto , Embolização Terapêutica/efeitos adversos , Hemoptise/etiologia , Hemoptise/terapia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
4.
Respirology ; 25(10): 1073-1081, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32052923

RESUMO

BACKGROUND AND OBJECTIVE: Average volume-assured pressure support-automated expiratory positive airway pressure (AVAPS-AE) combines an automated positive expiratory pressure to maintain upper airway patency to an automated pressure support with a targeted tidal volume. The aim of this study was to compare the effects of 2-month AVAPS-AE ventilation versus pressure support (ST) ventilation on objective sleep quality in stable patients with OHS. Secondary outcomes included arterial blood gases, health-related quality of life, daytime sleepiness, subjective sleep quality and compliance to NIV. METHODS: This is a prospective multicentric randomized controlled trial. Consecutive OHS patients included had daytime Pa CO2 > 6 kPa, BMI ≥ 30 kg/m2 , clinical stability for more than 2 weeks and were naive from home NIV. PSG were analysed centrally by two independent experts. Primary endpoint was sleep quality improvement at 2 months. RESULTS: Among 69 trial patients, 60 patients had successful NIV setup. Baseline and follow-up PSG were available for 26 patients randomized in the ST group and 30 in the AVAPS-AE group. At baseline, Pa CO2 was 6.94 ± 0.71 kPa in the ST group and 6.61 ± 0.71 in the AVAPS-AE group (P = 0.032). No significant between-group difference was observed for objective sleep quality indices. Improvement in Pa CO2 was similar between groups with a mean reduction of -0.87 kPa (95% CI: -1.12 to -0.46) in the ST group versus -0.87 kPa (95% CI: -1.14 to -0.50) in the AVAPS-AE group (P = 0.984). Mean NIV use was 6.2 h per night in both groups (P = 0.93). NIV setup duration was shorter in the AVAPS-AE group (P = 0.012). CONCLUSION: AVAPS-AE and ST ventilation for 2 months had similar impact on sleep quality and gas exchange.


Assuntos
Síndrome de Hipoventilação por Obesidade/fisiopatologia , Respiração com Pressão Positiva , Gasometria , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ventilação não Invasiva , Síndrome de Hipoventilação por Obesidade/sangue , Polissonografia , Estudos Prospectivos , Qualidade de Vida , Sono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA