Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int Endod J ; 45(9): 783-801, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22429152

RESUMO

This systematic review evaluates the diagnostic accuracy of radiographic methods employed to indicate presence/absence and changes over time of periapical bone lesions. Also investigated were the leads radiographic images may give about the nature of the process and the condition of the pulp in nonendodontically treated teeth. Electronic literature search included the databases PubMed, Embase and CENTRAL from January 1950 to June 2011. All languages were accepted provided there was an abstract in English. The MeSH terms were 'Cone beam computed tomography (CBCT)', 'Radiography, panoramic', 'Periapical diseases', 'Dental pulp diseases', 'Sensitivity and specificity', 'receiver operating characteristics (ROC) curve', 'Cadaver', 'Endodontics' and 'Radiography dental'. Two reviewers independently assessed abstracts and full text articles. An article was read in full text if at least one of the two reviewers considered an abstract to be potentially relevant. Altogether, 181 articles were read in full text. The GRADE approach was used to assess the quality of evidence of each radiographic method based on studies of high or moderate quality. Twenty-six studies fulfilled criteria set for inclusion. None was of high quality; 11 were of moderate quality. There is insufficient evidence that the digital intraoral radiographic technique is diagnostically as accurate as the conventional film technique. The same applies to CBCT. No conclusions can be drawn regarding the accuracy of radiological examination in identifying various forms of periapical bone tissue changes or about the pulpal condition.


Assuntos
Processo Alveolar/diagnóstico por imagem , Doenças Periapicais/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Doenças da Polpa Dentária/diagnóstico por imagem , Humanos , Radiografia Dentária Digital , Radiografia Panorâmica , Filme para Raios X
2.
Int Endod J ; 45(7): 597-613, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22329525

RESUMO

The aim of this systematic review was to appraise the diagnostic accuracy of signs/symptoms and tests used to determine the condition of the pulp in teeth affected by deep caries, trauma or other types of injury. Radiographic methods were not included. The electronic literature search included the databases PubMed, EMBASE, The Cochrane Central Register of Controlled Trials and Cochrane Reviews from January 1950 to June 2011. The complete search strategy is given in an Appendix S1 (available online as Supporting Information). In addition, hand searches were made. Two reviewers independently assessed abstracts and full-text articles. An article was read in full text if at least one of the two reviewers considered an abstract to be potentially relevant. Altogether, 155 articles were read in full text. Of these, 18 studies fulfilled pre-specified inclusion criteria. The quality of included articles was assessed using the QUADAS tool. Based on studies of high or moderate quality, the quality of evidence of each diagnostic method/test was rated in four levels according to GRADE. No study reached high quality; two were of moderate quality. The overall evidence was insufficient to assess the value of toothache or abnormal reaction to heat/cold stimulation for determining the pulp condition. The same applies to methods for establishing pulp status, including electric or thermal pulp testing, or methods for measuring pulpal blood circulation. In general, there are major shortcomings in the design, conduct and reporting of studies in this domain of dental research.


Assuntos
Doenças da Polpa Dentária/diagnóstico , Biomarcadores , Polpa Dentária/irrigação sanguínea , Exposição da Polpa Dentária/diagnóstico , Necrose da Polpa Dentária/diagnóstico , Teste da Polpa Dentária , Odontologia Baseada em Evidências/normas , Humanos , Pulpite/diagnóstico , Sensibilidade e Especificidade , Avaliação de Sintomas
3.
Int Endod J ; 35(12): 1005-11, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12653319

RESUMO

AIM: The aim of the study was to compare the quality of root fillings completed by lateral condensation (L), Thermafil (TF), and a new technique using Thermafil for backfilling (BF), with special emphasis on control of overfilling. METHODOLOGY: Sixty curved canals in plastic blocks were prepared with the ProFile system to size 40/04 taper in the apical half and to 06 taper in the coronal half. The canals were divided into three groups of 20. Apical patency was verified with a size 15 K-file. The canals were then filled using three different techniques: LC (20 canals), TF (20 canals), and BF, where a size 40 master point with sealer was seated prior to the introduction of a size 30 Thermafil point (20 canals). The same resin-based sealer was used on each occasion. The root fillings were assessed using stereo-microscopy for material extrusion, digital radiography for occurrence of voids, and microscopy of sections for voids and thickness of sealer layer. RESULTS: Extrusion of both gutta-percha and sealer occurred in all 20 canals filled with the TF technique, but only three and five cases of sealer extrusion were detected with LC and BF techniques, respectively. No voids were detected in the TF group, whereas small voids were present in most fillings in the LC and BF groups. The average total length of the voids was less than 1 mm per canal. The thickness of the sealer layer in the middle and apical parts was greater in the LC and BF groups than in the TF group. CONCLUSIONS: LC and BF techniques resulted in fewer overfills than TF. Voids were absent in TF fillings, whilst small voids were found in the LC and BF groups.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular/métodos , Raiz Dentária/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Guta-Percha , Humanos , Modelos Anatômicos , Modelos Dentários , Radiografia , Tratamento do Canal Radicular/métodos , Raiz Dentária/anatomia & histologia
4.
Int Endod J ; 34(3): 184-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12193263

RESUMO

AIM: This study examined and compared the inhibition of the antibacterial effect of saturated calcium hydroxide solution, chlorhexidine acetate and iodine potassium iodide by dentine, hydroxylapatite and bovine serum albumin. METHODOLOGY: Enterococcus faecalis strain A197A prepared to a suspension of 3 x 10(8) cells per ml in 0.5% peptone water was used. Fifty microL of saturated calcium hydroxide solution, 0.05% chlorhexidine acetate or 0.2/0.4% iodine potassium iodide were incubated at 37 degrees C with 28 mg dentine powder (DP), hydroxylapatite (HA) or bovine serum albumin (BSA) in 50 microL water for 1 h before adding 50 microL of the bacterial suspension. Samples for bacterial culturing were taken from the suspension 1 and 24 h after adding the bacteria. In further experiments, the amount of dentine was stepwise reduced from 28 mg 150 microL-1 to 2.8 mg 150 microL-1. RESULTS: Calcium hydroxide was totally inactivated by the presence of 28 mg of DP, HA or BSA. Chlorhexidine (0.05%) was strongly inhibited by BSA and slowed down by dentine. However, HA had little or no inhibitory effect on chlorhexidine. The antibacterial effect of 0.2/0.4% iodine potassium iodide on E. faecalis was totally inhibited by dentine (28 mg), but was practically unaffected by HA or BSA. A stepwise reduction of dentine from 28 mg 150 microL-1 to 2.8 mg 150 microL-1 was followed by a similar reduction of the inhibition of the antibacterial activity of chlorhexidine. Iodine potassium iodide was not inhibited at all with dentine amounts less than 28 mg. However, the effect of saturated calcium hydroxide solution was totally eliminated by dentine, in all four concentrations. CONCLUSION: Inhibition by dentine of the antibacterial activity of calcium hydroxide, chlorhexidine and iodine potassium iodide occurs by different mechanisms. Different components of dentine may be responsible for the inhibition of these three medicaments. Calcium hydroxide was particularly sensitive to inhibition by both inorganic and organic compounds.


Assuntos
Materiais Biocompatíveis/farmacologia , Dentina/fisiologia , Durapatita/farmacologia , Irrigantes do Canal Radicular/química , Soroalbumina Bovina/farmacologia , Animais , Anti-Infecciosos Locais/antagonistas & inibidores , Hidróxido de Cálcio/antagonistas & inibidores , Bovinos , Clorexidina/antagonistas & inibidores , Antagonismo de Drogas , Enterococcus faecalis/efeitos dos fármacos , Enterococcus faecalis/crescimento & desenvolvimento , Compostos de Iodo/antagonistas & inibidores , Iodeto de Potássio/antagonistas & inibidores
5.
Int Endod J ; 31(2): 103-11, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9868936

RESUMO

This study measured in vitro the displacement of natural canal centres in 18 human teeth before and after shaping by the step-back or Lightspeed techniques. Experimental roots (n = 9 per group), embedded in clear plastic, were cross-sectioned using a 0.1-mm-thick band saw at distances 1.25 mm, 3.25 mm and 5.25 mm from the apices. A stereo microscope was used to take 35 mm slides of the cut surfaces of the sectioned roots and canals. The slides of the uninstrumented canals were scanned into a computer and saved. Each sectioned root was then reassembled and the canals shaped by the step-back or Lightspeed technique. File size 40 and instrument size 50 were selected as the master apical file and master apical rotary for the step-back and Lightspeed groups, respectively. The 18 prepared canals were photographed, and the 35 mm slides scanned and computer stored as previously. This allowed the positions of the pre- and postinstrumented roots to be electronically superimposed for subsequent analyses. Displacements of the root canal centres before and after preparation were assessed in relation to the cross-sectional diameter of the files or instruments used. In addition, increases in cross-sectional area of the root canals after preparation were evaluated in relation to the cross-sectional area of the files or instruments used. Engine-driven nickel-titanium Lightspeed instruments caused significantly less (P < 0.001) displacement of the canal centres, so roots in the Lightspeed group remained better centred than those in the step-back group. The mean cross-sectional area after preparation in the Lightspeed group was significantly less (P < 0.001) than that recorded in the step-back group. Clinically, this implies less apical transportation and less dentine destruction with the Lightspeed technique than with the step-back technique.


Assuntos
Preparo de Canal Radicular/métodos , Instrumentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Humanos , Preparo de Canal Radicular/instrumentação , Ápice Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA