Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
J Contemp Dent Pract ; 16(6): 451-7, 2015 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-26323447

RESUMO

AIM: The aim of this study was to evaluate the inner surface of two ceramic systems: IPS Empress II (Ivoclar Vivadent, Germany) and In-Ceram Alumina (Vita Zahnfabrick, Germany) submitted to surface treatments, especially by Nd:YAG laser. MATERIALS AND METHODS: Fifty samples were prepared in pellet form for each ceramic system according to manufacturers' specifications. The samples were stored at room temperature and then be subjected to surface treatment: without treatment (T0) (control), hydrofluoric acid-etched (T1), hydrofluoric acid-etched associated with the airborne particle-abraded (T2); CoJet system (T3), Nd:YAG laser (T4). The data were performed the statistical analysis by ANOVA and Tukey's test (p < 0.001). RESULTS: The group control (T0) of the ceramics, the analysis showed the lowest roughness values; for the System Alumina In-Ceram, treatment with hydrofluoric acid (T1), associated with hydrofluoric acid and airborne particle-abraded (T2) and Nd:YAG laser (T4), had no statistically significant difference, whereas for the IPS Empress System II treatment with hydrofluoric acid (T1) and hydrofluoric acid associated with airborne particle-abraded (T2), had no statistically significant difference between the system and also CoJet (T3) and hydrofluoric acid associated with the airborne particle-abraded (T2). Photomicrographs of scanning electron microscopy showed different characteristics to the treatments for each ceramic system. CONCLUSION: The IPS Empress II had the appearance of favoring the retention when treated with hydrofluoric acid, as well as its association with the airborne particle-abraded. Uncertainty in Alumina, treatment with hydrofluoric acid associated with the airborne particle-abraded and CoJet system and provided a surface with irregularities. With respect to the laser further studies should be performed for parameters that are ideal for your application. CLINICAL RELEVANCE: The ceramic restorations are attractive due of their excellent esthetics and the ability to stay for long periods. However, the retention of ceramic requires further study.


Assuntos
Porcelana Dentária/química , Condicionamento Ácido do Dente/métodos , Ácido Fluorídrico/química , Lasers de Estado Sólido , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
2.
Ortodontia ; 47(5): 414-418, set.-out. 2014. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-760083

RESUMO

O objetivo deste estudo foi avaliar se o posicionamento da moldeira durante o tempo de presa do gesso pode causar a distorção dos modelos. Um total de 30 pares de modelos-mestre foi moldado com alginato e imediatamente vertido com gesso pedra especial. Os modelos foram divididos em dois grupos: no grupo 1, o gesso foi vertido sobre o molde e aguardada a presa; no grupo 2, depois de vertido o gesso, o conjunto (molde e gesso) foi posicionado sobre uma bancada de trabalho, ficando sobre o gesso a moldeira e o molde. O tamanho dos dentes e as distâncias foram medidos utilizando-se as ferramentas do software O3D (Widialabs, Brasil) nas imagens dos modelos de gesso digitalizados por scanner a laser (3Shape R-700, 3Shape A/S). Os dados foram analisados pelo teste t pareado e pela regressão linear ao nível de significância de 5%. A maioria das medidas foi semelhante para ambos os grupos, exceto para a distância intermolares inferiores. Não foi possível comprovar a presença de distorções nas medidas analisadas em função da posição da moldeira durante a presa do gesso.


The objective of this study was to assess if the positioning of the impression tray could cause plaster casts distortion during gypsum setting time. Fifteen pairs of master models were cast with alginate impression material and immediately poured with gypsum. Impressions were allowed to set with the tray in the not inverted position (group A) or in the inverted position (group B). The plaster models were digitized using a laser scanner (3Shape R-700, 3Shape A/S). Tooth size measurements and distances were obtained using O3D software (Widialabs, Brasil) measurement tools. Data were analyzed by paired t test and linear regression with 5% significance. Most measurements of both groups were similar, except for the lower intermolar distance.It was not possible to corroborate the presence of distortions owing to the position of the impression tray during gypsum setting time.


Assuntos
Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica
3.
J Contemp Dent Pract ; 15(6): 681-7, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25825090

RESUMO

Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.


Assuntos
Cefalometria/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Modelos Dentários , Sulfato de Cálcio/química , Cefalometria/instrumentação , Dente Canino/anatomia & histologia , Arco Dental/anatomia & histologia , Materiais Dentários/química , Humanos , Incisivo/anatomia & histologia , Lasers , Dente Molar/anatomia & histologia , Odontometria/estatística & dados numéricos , Sobremordida/patologia , Reprodutibilidade dos Testes
4.
Rev. Clín. Ortod. Dent. Press ; 9(3): 26-34, jun.-jul. 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-562638

RESUMO

O diagnóstico e o planejamento constituem etapas fundamentais para o sucesso do tratamento ortodôntico, nas quais o ortodontista deve ter inúmeros elementos que contribuem na tomada das decisões mais acertadas. O set-up, ou montagem de diagnóstico em modelo, é um importante recurso no planejamento da terapia ortodôntica corretiva. Consiste no reposicionamento dos dentes previamente removidos dos modelos de estudo e remontados sobre a base remanescente dos mesmos. Quando corretamente confeccionado, o set-up permite uma visualização tridimensional prévia dos problemas e limitações do caso, auxiliando na tomada de decisões quanto às exodontias em casos com problemas de espaços, à quantidade de perda de ancoragem, extensão e tipo de movimentação dentária, discrepância do volume dentário interarcadas, entre outros, indicando a melhor opção para o tratamento. Este trabalho expõe etapas importantes para sua confecção, sistema de avaliação e sua aplicação na elaboração de planos de tratamento ortodôntico.


Assuntos
Humanos , Diagnóstico Bucal , Ortodontia Corretiva , Planejamento de Assistência ao Paciente , Sulfato de Cálcio
5.
Ortodontia ; 41(n.esp): 317-323, dez. 2008.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-542724

RESUMO

As disfunções temporomandibulares (DTM) abrangem diferentes sinais e sintomas da articulação temporomandibular (ATM), músculos mastigatórios e estruturas relacionadas. Embora os fatores oclusais apresentem baixa associação na caracterização da DTM, a relação da morfologia esquelética com a disfunção da ATM permanece obscura. Em más-oclusões severas com - discrepâncias esqueléticas, o tratamento ortodôntico combinado a cirurgia ortognática é muitas vezes necessário. A cirurgia ortognática e os seus efeitos sobre a DTM têm sido objeto de investigação de muitos estudos nas ultimas décadas. O propósito deste artigo foi revisar a literatura avaliando os resultados da cirurgia ortognática sobre os sinais e sintomas da DTM em pacientes ortodôntico-cirúrgicos, bem como analisar as evidências pertinentes a esse tema.


Temporomandibular dysfunctions (TMD) comprise different signs and symptoms of the temporomandibular joint (TMJ), masticatory muscles and related structures. Although the occlusal factors do not seem to play an important role in the TMD characterization, the relationship between the skeletal morphology and the TMJ dysfunctions remains uncertain. In the presence of severe malocclusion with skeletal discrepancies. orthodontic treatment combined with orthognathic surgery is recommended. Orthognathic surgery and its effects on the TMD have been object of investigation of a number of studies in the last decades. The objective of this study was both to review the literature by evaluating the effects of the orthognathic surgery on the signs and symptoms of the TMD in orthosurgical patients, and to analyze the evidences related to this issue.


Assuntos
Humanos , Articulação Temporomandibular/anormalidades , Má Oclusão , Cirurgia Bucal
6.
Ortho Sci., Orthod. sci. pract ; 1(4): 362-367, 2008. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-544318

RESUMO

A esterilização e a biossegurança em Odontologia assim como em Ortodontia tem recebido inúmeras sugestões como também modificações, com o intuito de minimizar as chances de contaminação entre pacientes e profissionais. Vários são os trabalhos que classificam os procedimentos odontológicos como: críticos, semicríticos e acríticos, a fim de estabelecer protocolos de desinfecção, esterilização e biossegurança. Assim atenção especial ao paciente, preocupação com o profissional e pessoal auxiliar, bem como cuidado nos ambiente clínico e laboratorial tem sido ressaltados na busca de procedimentos de controle total de esterilização de instrumentais abordando vários métodos para enfim estabelecer um protocolo rígido no ambiente de trabalho.


Assuntos
Clínicas Odontológicas , Desinfecção , Esterilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA