Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Dent Mater ; 37(1): 191-200, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33276956

RESUMO

OBJECTIVE: This study aimed to investigate the effects of long-term use on the retention force and wear behavior of double crown systems. METHODS: Based on a common double crown design sixty pairs of telescopic crowns were fabricated and divided into six groups, each consisting ten samples: "Gold standard" cast gold alloy primary and secondary crown (GG) and cast non-precious alloy (NN), computer-aided design (CAD)/computer-aided manufacturing (CAM)-milled zirconia primary crown and galvanoformed secondary crown (ZG), CAD/CAM-milled non-precious alloy primary and secondary crown (CC NN), CAD/CAM-milled zirconia primary crown and non-precious alloy secondary crown (CC ZN) and CAD/CAM-milled zirconia primary crown and polyetheretherketone (PEEK) secondary crown (CC ZP). In the constant presence of artificial saliva, all samples were subjected to 10,000 joining-separation cycles at a velocity of 120 mm/min. Wear was analyzed by reflected light microscopy and confocal microscopy before and after artificial aging. RESULTS: Retention force losses were observed in each group after long-term use, with significant losses in the groups ZG and CC ZP (pZG = 0.01, pCC ZP = 0.049). During artificial aging, no significant differences in pull-off force were recorded for groups GG, NN and CC ZN. Regarding wear, merely the Y-TZP primary crowns of the CC ZP group displayed no surface changes. SIGNIFICANCE: All tested production methods and material combinations seem to be suitable for clinical practice. CAD/CAM technology allows similarly predictable results to be achieved as the gold standard. Confocal microscopy is recommended for surface examinations of double crowns.


Assuntos
Coroas , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Ligas de Ouro , Zircônio
2.
J Prosthodont Res ; 64(4): 498-505, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32063531

RESUMO

PURPOSE: This analysis focused on periodontal health in shortened dental arches (SDAs). METHODS: In a randomized controlled clinical trial, patients with missing molars in one jaw and at least one premolar and canine on both sides were eligible for participation. In the partial removable dental prosthesis (PRDP) group (n = 79), molars were replaced with a precision attachment retained PRDP. In the SDA group (n == 71), the SDA up to the second premolars was either left as is or restored with fixed dental prostheses. Outcome variables were vertical clinical attachment loss (CAL-V), pocket probing depth (PPD), bleeding on probing (BOP) and plaque index (PLI). For CAL-V and PPD, the changes at six measuring points per tooth were analyzed. For BOP and PLI, patient related rates were calculated for each point in time. Statistical methods included linear regression analyses. RESULTS: In the intention-to-treat (ITT) analysis for CAL-V in the study jaw, the 10 year patient related mean changes were 0.66 mm in the PRDP group and -0.13 mm in the SDA group. The resulting mean patient related group difference of 0.79 mm (95% CI: 0.20 mm-1.38 mm) was significant (p = 0.01). There were no significant differences in the ITT analyses for PPD. For BOP and PLI, significant group differences with more favorable results for the SDA group were found. CONCLUSIONS: In view of lacking substantial differences for CAL-V and PPD, the overall differences were considered of minor clinical relevance. The results add confirmatory evidence to the shortened dental arch concept and its clinical viability (controlled-trials.com ISRCTN97265367).


Assuntos
Prótese Parcial Removível , Perda de Dente , Dente Pré-Molar , Arco Dental , Humanos , Dente Molar
3.
J Dent ; 80: 55-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30355509

RESUMO

OBJECTIVES: To compare oral health-related quality of life (OHRQoL) in patients with either molar replacement by partial removable dental prostheses (PRDP) or with restored shortened dental arches (SDA) over a period of 10 years. METHODS: In this multi-center RCT, a consecutive sample of 215 patients with bilateral molar loss in at least one jaw was initially recruited in 14 prosthodontic departments. Of those patients, 150 could be randomly allocated to the treatment groups (SDA: n = 71; PRDP: n = 79), received the allocated treatment, and were available for follow-up assessments. OHRQoL was assessed using the 49-item version of the Oral Health Impact Profile (OHIP) before treatment (baseline) and at follow-ups after treatment (4-8 weeks and 6, 12, 24, 36, 48, 60, 96, and 120 months). To investigate the course of OHRQoL over time, we longitudinally modelled treatment and time effects using mixed-effects models. RESULTS: OHRQoL substantially improved from baseline to first follow-up in both groups indicated by a mean decrease in OHIP scores of 20.0 points (95%-CI: 12.5-27.5). When compared to the SDA group, OHRQoL in the PRDP group was not significantly different (-0.6 OHIP points; 95%-CI: -7.1 to 5.9) during the study period when assuming a constant time effect. OHRQoL remained stable over the 10 years with a statistically insignificant time effect (p = 0.848). CONCLUSIONS: For patients requesting prosthodontic treatment for their lost molars, treatments with SDA or PRDP improve clinically relevantly OHRQoL and maintain it over a period of 10 years with no option being superior to the other. CLINICAL SIGNIFICANCE: Since there was no significant difference between the two treatment options over the observation period of 10 years, and since results have stayed stable over time, patients can be informed that both treatment concepts are equivalent concerning OHRQoL.


Assuntos
Arco Dental , Prótese Parcial Removível , Humanos , Saúde Bucal , Qualidade de Vida , Inquéritos e Questionários
4.
Int J Prosthodont ; 31(1): 77-84, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29316570

RESUMO

PURPOSE: This study aimed to compare the long-term outcomes of two different nonimplant treatments in the bilateral shortened dental arch (SDA). MATERIALS AND METHODS: In a multicenter randomized controlled clinical trial, patients with complete molar loss in one arch were assigned to one of two different nonimplant treatments. In the partial removable dental prosthesis (PRDP) group, patients were provided with a distal-extension prosthesis retained with precision attachments. In the SDA group, patients were treated according to the SDA concept by preserving or restoring a premolar occlusion. RESULTS: Of the 152 treated patients, 82 reached the 10-year examination independent of their dental or prosthetic status. In the intention-to-treat analysis, the survival rates for tooth loss at 10 years were 0.44 (95% confidence interval [CI]: 0.30 to 0.56) in the PRDP group and 0.52 (95% CI: 0.37 to 0.65) in the SDA group. For tooth loss in the study arch, the survival rates were 0.67 (95% CI: 0.52 to 0.78) in the PRDP group and 0.60 (95% CI: 0.45 to 0.73) in the SDA group. The number of teeth lost was higher than expected. In a multivariate analysis using a multiple Cox regression model, the covariates age (unit: 1 year, Hazard Ratio [HR]: 1.033, P = .03) and DMFT value (unit: 1 tooth, HR: 1.121, P = .03) were significant for time to first tooth loss in the study arch. CONCLUSION: The results suggest an overestimation of the influence of the prosthetic management of the bilateral SDA. In treatment decisions, patient preferences should be considered with appropriate weight.


Assuntos
Arco Dental/patologia , Prótese Parcial Removível , Arcada Parcialmente Edêntula/reabilitação , Perda de Dente , Coroas , Índice CPO , Dente Suporte , Oclusão Dentária , Encaixe de Precisão de Dentadura , Feminino , Humanos , Masculino , Dente Molar , Fatores de Risco
5.
Int J Comput Dent ; 20(2): 151-164, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28630956

RESUMO

The aim of this study was to compare the accuracy of six intraoral scanners as regards clinically relevant distances using a new method of evaluation. An additional objective was to compare intraoral scanners with the indirect digitization of model scanners. A resin master model was created by 3D printing and drilled in five places to reflect the following distances: intermolar width (IMW), intercanine width (ICW), and arch length (AL). To determine a gold standard, the distances were measured with a coordinate measuring instrument (Zeiss O-Inspect 422). The master model was scanned 37 times with the following intraoral scanners: Apollo DI (Sirona), CS 3500 (Carestream Dental), iTero (Cadent), PlanScan (Planmeca), Trios (3Shape), and True Definition (3M Espe), and indirectly digitized with the OrthoX Scan (Dentaurum). The digital models were then measured, and deviations from the gold standard calculated. Significant differences were found between the devices. Among the intraoral scanners, Trios and iTero showed the most accurate results, although CS 3500, True Definition, and Apollo DI achieved comparable results. PlanScan demonstrated the highest deviations from the gold standard, and presented a high standard deviation (SD). Direct digitization revealed comparable (and, in fact, slightly higher) accuracy than indirect digitization. Both indirect digitization and most of the intraoral scanners were therefore demonstrated to be suitable for use in the orthodontic office, with the exception of PlanScan, which did not meet the demands of individual orthodontic treatment.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica/instrumentação , Planejamento de Prótese Dentária , Humanos , Modelos Dentários , Tecnologia Odontológica
6.
Int J Comput Dent ; 20(4): 363-375, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29292411

RESUMO

Plaster casts can be digitized with desktop scanners, intraoral scanners, and recently also with cone beam computed tomography (CBCT). The aim of this study was to investigate the accuracy of five different CBCT devices digitizing a plaster cast. A study cast serving as a patient was made using the double mix impression technique, and the impression was poured out with plaster. On the resulting plaster cast, arch length (AL), intermolar width (IMW), and intercanine width (ICW) were measured by a coordinate measuring machine (CMM) (Zeiss O-Inspect 422). The patient cast was then scanned by five CBCT devices - CS 9300, CS 9300 Select, CS 8100 3D (all Carestream), Promax 3D Mid (Planmeca), and Whitefox (Acteon) - in eight scan modes. For each CBCT device, 37 scans were performed. The resulting DICOM data were exported as stereolithographic (STL) data and linearly measured using Convince Premium 2012 (3Shape) software. All measurements were compared to the reference master values of the patient cast. The accuracy measurements showed significant differences among the CBCT devices. The highest accuracy was achieved by Whitefox (IMW: mean ± standard deviation (SD): 5.5 ± 5.7 µm) and CS 9300 (IMW: -15 ± 7.4 µm). Comparable results with less accuracy were shown by CS 8100 3D (IMW: -81.2 ± 7.4 µm) and CS 300 Select (IMW: -82.2 ± 6.6 µm). Significantly lower accuracy was shown by Promax 3D Mid (IMW: -126.1 ± 4.8 µm). Some CBCT devices are suitable for the digitization of plaster casts and show very good clinical accuracy. Dental offices equipped with CBCT devices could digitize plaster casts without the need for additional devices.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Modelos Dentários , Software , Humanos , Estereolitografia
7.
Clin Oral Investig ; 21(6): 1945-1951, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27785586

RESUMO

OBJECTIVES: Being a secondary outcome in a multicenter randomized controlled trial, the present analysis focused on interdental spacing in the shortened dental arch (SDA). The aim was to evaluate changes in interdental spacing in dependence of two different treatments after an observation period of up to 5 years. MATERIAL AND METHODS: Patients were either treated with a partial removable dental prosthesis (PRDP) for molar replacement (PRDP group) or according to the SDA concept aiming at a premolar occlusion (SDA group) in a randomized manner. Interdental spacing in the anterior region was measured with gauges and categorized as "0" (<0.1 mm), "1" (<0.5 mm), "2" (0.5-1 mm), and "3" (>1 mm). The statistical analysis was performed with analysis of variance models followed by linear contrast. RESULTS: Ninety-one patients (SDA n = 41, PRDP n = 50) were included. Changes of interdental spacing were detected in 70.7 % of all cases. A significant difference between the mean score changes was found in the mandible comparing the PRDP group and the SDA group. The respective mean score changes from baseline to 5 years were 0.23 (SD 0.49) for the PRDP group and 0.02 (SD 0.30) for the SDA group (p = 0.023). CONCLUSIONS: Major interdental spacing could be observed in neither of the groups. The SDA concept resulted in a slightly better outcome. CLINICAL RELEVANCE: When deciding whether to replace missing molars, the present results give further support to the SDA concept.


Assuntos
Arco Dental/patologia , Arcada Parcialmente Edêntula/reabilitação , Oclusão Dentária , Encaixe de Precisão de Dentadura , Prótese Parcial Removível , Feminino , Humanos , Masculino , Dente Molar , Odontometria , Fatores de Risco , Perda de Dente
8.
GMS J Med Educ ; 33(4): Doc65, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27579365

RESUMO

AIM: At the annual meeting of German dentists in Frankfurt am Main in 2013, the Working Group for the Advancement of Dental Education (AKWLZ) initiated an interdisciplinary working group to address assessments in dental education. This paper presents an overview of the current work being done by this working group, some of whose members are also actively involved in the German Association for Medical Education's (GMA) working group for dental education. The aim is to present a summary of the current state of research on this topic for all those who participate in the design, administration and evaluation of university-specific assessments in dentistry. METHOD: Based on systematic literature research, the testing scenarios listed in the National Competency-based Catalogue of Learning Objectives (NKLZ) have been compiled and presented in tables according to assessment value. RESULTS: Different assessment scenarios are described briefly in table form addressing validity (V), reliability (R), acceptance (A), cost (C), feasibility (F), and the influence on teaching and learning (EI) as presented in the current literature. Infoboxes were deliberately chosen to allow readers quick access to the information and to facilitate comparisons between the various assessment formats. Following each description is a list summarizing the uses in dental and medical education. CONCLUSION: This overview provides a summary of competency-based testing formats. It is meant to have a formative effect on dental and medical schools and provide support for developing workplace-based strategies in dental education for learning, teaching and testing in the future.


Assuntos
Educação em Odontologia , Educação Médica , Aprendizagem , Odontólogos , Humanos , Reprodutibilidade dos Testes
9.
J Adv Prosthodont ; 8(1): 30-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26949485

RESUMO

PURPOSE: The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. MATERIALS AND METHODS: An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling 5℃-55℃ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at 137℃, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. RESULTS: The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. CONCLUSION: The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

10.
Clin Oral Investig ; 19(5): 1029-37, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25280511

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the trend of dental practitioners in the federal state of Saarland in Germany in regard to restoring endodontically treated teeth using a Web-based survey. MATERIALS AND METHODS: An interactive Web-based survey instrument was developed, including seven clinical scenarios, presented by photographs of natural incisor and premolar with different types of cavities. Following a decision tree adapted to the clinical treatment, questions on different aspects of the post-endodontic treatment were asked. All 615 members of the Saarland Dental Association (SDA) were asked to participate in the survey. RESULTS: A total of 33 % completed the survey. The majority of the participants believed in the reinforcement effect of the ferrule design, as well as the post placement. The vast majority of the responding practitioners (92 %) adapted their treatment strategies to a high extent to the destruction degree of the endodontically treated tooth. Fiber-reinforced composite (FRC) posts are the most popular prefabricated post type, regardless of the cavity size and tooth localization. Significant differences between the dentists according to the degree of experience were detected only for the use of glass-ionomer cements as core buildup material. CONCLUSIONS: The predominant post-endodontic treatment strategies of German dental practitioners are only partly in agreement with the current literature. There is a clear trend toward the increasing use of metal-free post and core materials. CLINICAL SIGNIFICANCE: Although the participants showed a general adoption of modern materials and techniques, different patterns of post-endodontic treatment were revealed that were not consistent with approaches supported by the literature.


Assuntos
Dente Pré-Molar , Restauração Dentária Permanente/métodos , Incisivo , Padrões de Prática Odontológica/estatística & dados numéricos , Dente não Vital/terapia , Materiais Dentários , Alemanha , Humanos , Internet , Técnica para Retentor Intrarradicular , Inquéritos e Questionários
11.
Clin Oral Investig ; 18(9): 2159-69, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24452826

RESUMO

OBJECTIVES: The aim of this multi-center, randomized controlled trial was to assess the impact of missing posterior support on the risk for temporomandibular disorder (TMD) pain by comparing patients with either shortened dental arches (SDA) or molar replacement by removable dental prostheses (RDP). METHODS: A sample of 215 patients with bilateral molar loss in at least one jaw was consecutively recruited in 14 prosthodontic departments of dental schools in Germany. Of the initial sample, 152 patients (mean age: 59.7 years; 53.9 % female) received randomly allocated interventions (SDA: n = 71; RDP: n = 81). Presence of TMD pain was assessed using patients' self-reports and was verified by physical examination and by pain intensity, as the mean of current pain, worst pain, and average pain in the last 6 months, with 10-point ordinal rating scales. Assessments were performed before treatment and at follow-ups until 60 months after treatment. Impact of interventions on TMD risk and pain intensity was computed by applying logistic and linear random-intercept models. RESULTS: Tooth replacement (RDP) did not significantly change the risk for self-reported (odds ratio [OR]: 1.1; confidence interval [CI]: 0.4 to 3.4) or clinically verified (OR: 0.7; CI: 0.1 to 4.3) TMD pain compared to no tooth replacement (SDA). Mean characteristic pain intensity was virtually identical in both groups (Coeff: 0.01; CI: -0.30 to 0.32). CONCLUSION: Retaining or preservation of an SDA is not a major risk factor for TMD pain over the course of 5 years when compared to molar replacement with RPDs. CLINICAL RELEVANCE: Seemingly, missing molars do not have to be replaced in order to prevent TMD pain.


Assuntos
Arco Dental/patologia , Arcada Parcialmente Edêntula/patologia , Transtornos da Articulação Temporomandibular/etiologia , Prótese Parcial Removível , Feminino , Alemanha , Humanos , Arcada Parcialmente Edêntula/reabilitação , Masculino , Pessoa de Meia-Idade , Dente Molar , Medição da Dor , Medição de Risco , Fatores de Risco
12.
Acta Odontol Scand ; 72(5): 392-400, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24304290

RESUMO

OBJECTIVE: Zirconia implant abutments have gained a much broader clinical use over the past few years. The aim of the present study was to assess the clinical performance of a pre-fabricated zirconium dioxide implant abutment for single-tooth replacement in the posterior region. MATERIALS AND METHODS: Forty implants of the XiVE(®) S plus screw type (DENTSPLY Friadent, Mannheim, Germany) were inserted in the posterior region of 24 patients and provided with zirconium dioxide abutments (FRIADENT(®) CERCON(®) Abutment, DENTSPLY Friadent). The following parameters were used to document the state of soft tissue: modified plaque index, modified sulcus bleeding index and pocket depth. Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 36-month recall. RESULTS: Thirty-seven implants could be followed up after 36 months in function. One patient wearing two abutments was lost to follow-up. One abutment exhibited a rotational misfit after 2 years in function. A further abutment showed the same failure at the 36-months recall appointment. In the remaining 36 implants the soft and hard tissue parameters were indicative of a low inflammatory status. Compared to the baseline situation, a partly significant bone apposition could be observed. Chipping of parts of the veneering ceramic was registered in 22% of the remaining implant restorations. CONCLUSIONS: The use of zirconia abutments in this study lead to mainly healthy peri-implant hard and soft tissue conditions but, considering the observed failures after 3 years in function, clinical long-term results should be awaited before recommending full zirconia implant abutments in a posterior indication.


Assuntos
Dente Suporte , Implantes Dentários , Zircônio , Humanos
13.
Dent Mater ; 28(8): 909-18, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22608163

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the influence of different finishing procedures on the wear behavior of zirconia against natural enamel. METHODS: 64 quadratic specimens (10 mm × 10 mm × 2 mm) were cut from a commercial hipped dental Y-TZP ceramic. Four different groups with 16 specimens each were formed according to the following finishing procedures: PZ (polished), RR (fine-grit diamond), GR (coarse-grit diamond), GZ (glazed). Polished specimens of a leucite-reinforced glass ceramic (Empress CAD) were used as a control (GC). The materials were subjected to the Ivoclar wear method (Willytec chewing simulator, 120,000 cycles, 5kg weight) with 80 natural caries-free cusps of first upper molars as antagonists. Wear was analyzed for both the enamel cusps and test specimens by measurement of the vertical substance loss with a laser scanner. Surface roughness was measured by means of a white-light interferometer. RESULTS: The surface roughness was significantly different among the polished, diamond-finished, and glazed ceramic specimens (ANOVA, post hoc Bonferroni p<0.05). The results of the one-way ANOVA indicated that the finishing technique significantly affected enamel wear (p<0.05). The post hoc test indicated that the specimens finished with the coarse diamond caused significantly higher antagonist wear than the polished ones. Polished zirconia showed the lowest wear of the antagonist enamel, with a mean value of 171.74 (SD = 121.68), and resulted in enamel wear that was not significantly different from that of the glass ceramic control group. No significant linear correlation could be found between pre-testing surface roughness and abrasive wear. SIGNIFICANCE: If zirconia is used without veneering material for crowns and fixed dental prostheses (FDPs), the surface must be well-polished if occlusal adjustments with coarse diamonds are performed. The polishing step reduces the wear of the opposing enamel.


Assuntos
Porcelana Dentária , Desgaste de Restauração Dentária , Ítrio , Zircônio , Análise de Variância , Esmalte Dentário , Polimento Dentário , Humanos , Mastigação , Microscopia Eletrônica de Varredura , Estatísticas não Paramétricas , Propriedades de Superfície
14.
Gerodontology ; 29(2): e57-62, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21615466

RESUMO

OBJECTIVE: To investigate nursing home managers' perceptions and attitudes towards oral health care and access to dental services for aged care facility residents. METHOD: Questionnaires containing 28 closed-ended questions were mailed to all 114 nursing homes in Saarland, Germany. Descriptive statistics were calculated for response items. RESULTS: Facility response rate was 39%. None of the nursing homes in this study offered systematic dental health care. Initial dental screening was carried out only in one facility. In 81%, dental examinations only took place if required. Although stationary dental equipment was available only in one home, dental treatment was carried out in 71% of the cases by a dentist in the nursing home. Eighty-four per cent of the homes' managements rated the state of the dentition of the inhabitants as satisfying. Over half of the managers indicated satisfaction with the know-how of their nursing staff concerning oral hygiene procedures. The most significant barriers to provision of dental care in the facilities according to their managers were staff shortage, lack of interest of the inhabitants and financial concerns. CONCLUSIONS: The results of this study showed an urgent need for estimating a programme for systematic dental care for institutionalised elder people in the federal state of Saarland.


Assuntos
Pessoal Administrativo/psicologia , Atitude Frente a Saúde , Assistência Odontológica para Idosos , Necessidades e Demandas de Serviços de Saúde , Instituição de Longa Permanência para Idosos , Casas de Saúde , Idoso de 80 Anos ou mais , Pessoal Técnico de Saúde , Assistência Odontológica para Idosos/economia , Odontólogos , Dentição , Ingestão de Alimentos/fisiologia , Alemanha , Acessibilidade aos Serviços de Saúde , Necessidades e Demandas de Serviços de Saúde/estatística & dados numéricos , Instituição de Longa Permanência para Idosos/economia , Humanos , Tempo de Internação/estatística & dados numéricos , Mastigação/fisiologia , Casas de Saúde/economia , Saúde Bucal/estatística & dados numéricos , Higiene Bucal/estatística & dados numéricos , Política Organizacional , Recursos Humanos
15.
Clin Oral Investig ; 16(3): 951-60, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21611728

RESUMO

The purpose of this study is to compare success rates of dual-viscosity impressions for two types of mixing techniques of the polyether elastomeric impression material. Additionally, influencing parameters on the success rates should be evaluated. The expectation was that there would be no difference between the success rates for the two mixing techniques. Two centres enrolled 290 subjects (727 teeth) into the trial. Patients were randomized for the two types of mixing techniques. One step, dual-viscosity impressions were made with either statically mixed Impregum Soft tray material (SAM) or dynamically mixed Impregum Penta H DuoSoft (DMM). Low viscosity Impregum Garant L DuoSoft was used for both groups. Gingival displacement involved the use of two braided cords. Full-arch trays were used exclusively. Both critical defects and operator errors were assessed for the first impression taken by trained dentists. The primary outcome was impression success. For comparison of the two mixing techniques, the odds ratio for success and the corresponding one-sided 95% confidence interval was calculated by a logistic regression model. To account for the dependence between several teeth within one patient, the method of general estimating equations was used. The overall impression success rate was 35.4%. Both mixing techniques showed equal success rates indicated by an OR of 1.0 and a lower limit of the one-sided 95% confidence interval of 0.71. Using this result to develop the corresponding interval for the difference, it could be shown that the success rate using SAM was at most 8.2% lower than that when using DMM with a probability of 95%. Multivariate logistic regression analysis of other potential influencing factors showed position of finish line (p = 0.008, supra compared to mixed), blood coagulation disorder (p = 0.021) and the level of training of the clinician (student vs dentist, p=0.008) to have an independent influence on the success rate. Dynamic mechanical mixing and the new static mixing of polyether tray material showed nearly equal success rates in the study even though success rates were comparatively low (DMM, 35.3%; SAM, 35.4%).


Assuntos
Coroas , Materiais para Moldagem Odontológica/síntese química , Técnica de Moldagem Odontológica , Idoso , Intervalos de Confiança , Técnica de Moldagem Odontológica/instrumentação , Elastômeros , Éteres , Feminino , Técnicas de Retração Gengival , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Razão de Chances , Resinas Sintéticas/síntese química , Tecnologia Farmacêutica/métodos , Viscosidade
16.
Clin Oral Investig ; 16(6): 1659-67, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22173722

RESUMO

OBJECTIVES: The objective of this in vitro study was to investigate the behavior of different composite restorative materials under the load of cast circumferential clasps for removable dental prostheses (RDPs). METHODS: In 60 human molars, standardized mesial-occlusal-distal cavities were prepared. The cavities were restored with the following materials: Definite, Tetric Ceram, SureFil, Heliomolar RO, Ariston pHc, and Oralloy, and provided with a rest seat. The rest seats were subjected to 5,000 cycles of thermal cycling and 1,200,000 masticatory cycles in a mastication simulator via cobalt-chromium circumferential clasps cast to standardized frameworks in a laboratory model designed to simulate the biomechanics of a free-end denture base. Fracture analysis of the restorations was performed by light microscopy. Before and after loading, material wear was measured with a 3D-laser scanner, and an analysis of the marginal quality was performed in an SEM at ×200 applying the replica technique. RESULTS: No significant differences in the fracture behavior among the composite materials were found; the amalgam control group showed a significantly higher fracture resistance. Regarding the wear of the materials, the composites Definite and SureFil exhibited a behavior similar to that of amalgam. The other composites demonstrated higher wear rates. The initial marginal quality was significantly worse for Ariston pHc. The marginal adaptation decreased significantly after thermal and mechanical loading for Definite and Ariston pHc. CONCLUSIONS: In terms of the investigated aspects of mechanical performance, the tested composites seemed to be inferior to amalgam. Further clinical studies are needed to evaluate the ability of composite restorations to provide support for RDP clasps. CLINICAL RELEVANCE: The use of composites as direct restoration materials should be avoided in teeth, which serve as abutments for clasp-retained RDPs.


Assuntos
Grampos Dentários , Materiais Dentários/química , Prótese Parcial Removível , Resinas Acrílicas/química , Fenômenos Biomecânicos , Força de Mordida , Ligas de Cromo/química , Resinas Compostas/química , Dente Suporte , Amálgama Dentário/química , Preparo da Cavidade Dentária/classificação , Adaptação Marginal Dentária , Falha de Restauração Dentária , Desgaste de Restauração Dentária , Restauração Dentária Permanente/classificação , Análise do Estresse Dentário/instrumentação , Humanos , Imageamento Tridimensional/métodos , Lasers , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Cerâmicas Modificadas Organicamente/química , Poliuretanos/química , Siloxanas/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Terpenos/química
17.
Dent Mater ; 27(7): 684-91, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21514656

RESUMO

OBJECTIVES: The aim of this study was to evaluate the mechanical properties and the subcritical crack growth behavior of a presintered dental Y-TZP (Kavo Everest ZS) and a hot isostatic pressed Y-TZP (Kavo Everest ZH) and to perform life data analysis. METHODS: For each material 150 bending bars were produced. The initial fracture strength was determined in a four-point bending test. The subcritical crack growth parameters n and A were determined in a dynamic fatigue method at four decreasing loading rates from 110MPa/s to 0.11MPa/s in distilled water at 38°C. For each loading rate Weibull statistics were performed and the Weibull moduli m and characteristic strengths σ(0) were calculated. Using these data, strength-fracture probability-life time (SPT) predictions were derived for 1 day, 1 year, 5 years and 10 years, based on a static crack growth mechanism. RESULTS: The "hipped" Y-TZP ceramic exhibited a higher initial strength (σ(c)=1618.18), characteristic strength (σ(0)=837.15) and fracture toughness (K(IC)=4.52MPa/m(1/2)) than the pre-sintered ceramic (σ(c)=1431, σ(0)=745.46 and K(IC)=3.17MPa/m(1/2), respectively). Fatigue parameters, n and A, were 28.5 and 7.97×10(-24) for Everest ZH and 30.15 and 5.47×10(-20) for Everest ZS. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was 259.34MPa for Everest ZH and 263.2MPa for Everest ZS. CONCLUSIONS: Although the "hipped" Y-TZP showed favorable initial mechanical properties, no significant difference could be found in the susceptibility of both ceramics to subcritical crack growth and their long-term strength.


Assuntos
Porcelana Dentária/química , Falha de Restauração Dentária , Análise do Estresse Dentário , Ítrio/química , Zircônio/química , Coroas , Prótese Parcial Fixa , Elasticidade , Análise de Falha de Equipamento , Temperatura Alta , Teste de Materiais , Pressão , Propriedades de Superfície , Análise de Sobrevida
18.
Dent Mater J ; 30(1): 109-14, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21282879

RESUMO

The aim of the study was to evaluate the influence of fatigue and cementation mode on the fracture behaviour of endodontically treated bovine incisors restored with fiber-reinforced-composite (FRC) posts and crowns. Forty-eight endodontically treated incisors were restored with FRC posts, composite build-ups, and cast crowns. In 16 teeth, each of the posts were cemented conventionally with KetacCem (3M Espe) or adhesively with Panavia F (Kuraray) or RelyXUniCem (3M Espe). One-half of the specimens in each group were subjected to thermal cycling with 10,000 cycles at 5-55°C and mechanical aging, loading the specimens in 1,200,000 cycles with 50 N. Fracture resistance was determined by loading the specimens until fracture at an angle of 45°. The loading test showed that cementation mode and fatigue testing had an influence on the load bearing capability. Before fatigue testing no statistically significant differences between the different cementation modes could be detected. After fatigue testing, conventionally cemented FRC posts lead to statistically significant higher fracture loads compared to adhesively luted posts. Most specimens fractured in a favourable way, independent from the type of cementation.


Assuntos
Coroas , Colagem Dentária , Cimentos Dentários/uso terapêutico , Falha de Restauração Dentária , Técnica para Retentor Intrarradicular/instrumentação , Fraturas dos Dentes/prevenção & controle , Animais , Força de Mordida , Bovinos , Cimentos Dentários/química , Retenção em Prótese Dentária , Restauração Dentária Permanente , Análise do Estresse Dentário , Incisivo , Óxido de Magnésio/química , Óxido de Magnésio/uso terapêutico , Teste de Materiais , Cimento de Policarboxilato/química , Cimento de Policarboxilato/uso terapêutico , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Suporte de Carga , Óxido de Zinco/química , Óxido de Zinco/uso terapêutico
19.
Clin Oral Investig ; 15(1): 89-97, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20049497

RESUMO

This in vitro study investigated the fracture behaviour of implant-implant-supported and implant-tooth-supported all-ceramic fixed dental prostheses (FDP) using zirconium dioxide implant abutments (FRIADENT® CERCON® abutments, DENTSPLY Friadent). Six different test groups (n = 8) were prepared. Groups 1, 2, 4, and 5 represented an implant-implant-supported FDP condition, whereas groups 3 and 6 simulated an implant-tooth-supported FDP condition. The second right premolar of the mandible was replaced with a pontic tooth. In groups 2 and 5, implant abutments were individualised by circumferential preparation. XiVe® S plus screw implants (DENTSPLY Friadent) that were 4.5 mm (first molar) and 3.8 mm (first premolar) in diameter and 11 mm in length and metal tooth analogues with simulated periodontal mobility, representing the first right premolar, were mounted in a polymethyl methacrylate block. The FDPs were cemented with KetacCem (3 M Espe GmbH, Germany). Groups 4, 5, and 6 were thermomechanically loaded (thermal and mechanical cycling (TCML) = 1.2 × 106; 10,000 × 5°/55°) and subjected to static loading until failure. Statistical analysis of data obtained for the force at fracture was performed using non-parametric tests. All samples tested survived TCML. In the implant-implant-supported groups, circumferential abutment preparation resulted in a tendency to lower fracture forces compared to groups with unprepared abutments (group 1, 472.75 ± 24.71 N; group 2, 423.75 ± 48.48 N; group 4, 647.13 ± 39.10 N; group 5, 555.86 ± 30.34 N). The implant-tooth-supported restorations exhibited higher fracture loads (group 3, 736.25 ± 82.23 N; group 6, 720.75 ± 48.99 N) than the implant-implant-supported restorations which did not possess circumferentially individualised abutments. Statistically significant differences were found when comparing the non-artificially aged groups. Implant-tooth-supported FDP restorations did exhibit an increased fracture load compared to implant-implant-supported FDP restorations.


Assuntos
Dente Suporte , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Análise do Estresse Dentário , Prótese Parcial Fixa , Desenho Assistido por Computador , Porcelana Dentária , Planejamento de Prótese Dentária , Modelos Dentários , Estatísticas não Paramétricas , Zircônio
20.
Clin Oral Investig ; 15(2): 157-63, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20084415

RESUMO

The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments (ZirDesign™; Astra Tech, Mölndal, Sweden) supporting anterior single crowns (SCs). Four different test groups (n = 8) representing anterior SCs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (left central incisor) from a prosthetic point of view, which allows for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position, requiring an angulated (20°) abutment. OsseoSpeed™ implants (Astra Tech) 4.5 mm in diameter and 13 mm in length were used to support the abutments. The SCs (chromium cobalt alloy) were cemented with glass ionomer cement. Groups 2 and 4 were thermomechanically loaded (TCML = 1.2 × 106; 10,000 × 5°/55°) and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples tested survived TCML. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the groups with straight abutments or the groups with angulated abutments. The restorations that utilized angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1, 280.25 ± 30.45 N; group 2, 268.88 ± 38.00 N; group 3, 355.00 ± 24.71 N; group 4, 320.71 ± 78.08 N). This difference in load-bearing performance between straight and angulated abutments was statistically significant (p = 0.000) only when no artificial aging was employed. The vast majority of the abutments fractured below the implant shoulder.


Assuntos
Dente Suporte , Implantes Dentários para Um Único Dente , Porcelana Dentária , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Coroas , Análise do Estresse Dentário , Modelos Dentários , Estatísticas não Paramétricas , Fatores de Tempo , Suporte de Carga , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA