1.
Respir Res ; 25(1): 247, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890648

RESUMO

INTRODUCTION: Sleep-disordered breathing (SDB) is a major comorbidity in idiopathic pulmonary fibrosis (IPF) and is associated with a poor outcome. There is a lack of knowledge regarding the impact of SDB treatment on IPF. We assessed at one year: (1) the effect of CPAP and/or nocturnal oxygen therapy on IPF regarding lung function, blood mediators, and quality of life; (2) adherence to SDB treatment and SDB changes. METHODOLOGY: This is a prospective study of consecutive newly diagnosed IPF patients initiating anti-fibrotic treatment. Lung function, polysomnography, blood tests and quality of life questionnaires were performed at inclusion and after one year. Patients were classified as obstructive sleep apnoea (OSA), central sleep apnoea (CSA), and sleep-sustained hypoxemia (SSH). SDB therapy (CPAP and/or nocturnal oxygen therapy) was initiated if needed. RESULTS: Fifty patients were enrolled (36% had OSA, 22% CSA, and 12% SSH). CPAP was started in 54% of patients and nocturnal oxygen therapy in 16%. At one-year, polysomnography found improved parameters, though 17% of patients had to add nocturnal oxygen therapy or CPAP, while 33% presented SDB onset at this second polysomnography. CPAP compliance at one year was 6.74 h/night (SD 0.74). After one year, matrix metalloproteinase-1 decreased in OSA and CSA (p = 0.029; p = 0.027), C-reactive protein in OSA (p = 0.045), and surfactant protein D in CSA group (p = 0.074). There was no significant change in lung function. CONCLUSIONS: Treatment of SBD with CPAP and NOT can be well tolerated with a high compliance. IPF patients may exhibit SDB progression and require periodic re-assessment. Further studies to evaluate the impact of SDB treatment on lung function and serological mediators are needed.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Fibrose Pulmonar Idiopática , Oxigenoterapia , Síndromes da Apneia do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Masculino , Fibrose Pulmonar Idiopática/terapia , Fibrose Pulmonar Idiopática/complicações , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/fisiopatologia , Projetos Piloto , Idoso , Estudos Prospectivos , Síndromes da Apneia do Sono/terapia , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/complicações , Oxigenoterapia/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Polissonografia/métodos , Qualidade de Vida
3.
Arch Bronconeumol ; 59(10): 638-644, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37516558

RESUMO

INTRODUCTION: Obstructive sleep apnea (OSA) is heterogeneous and complex, but its severity is still based on the apnea-hypoapnea index (AHI). The present study explores using cluster analysis (CA), the additional information provided from routine polysomnography (PSG) to optimize OSA categorization. METHODS: Cross-sectional study of OSA subjects diagnosed by PSG in a tertiary hospital sleep unit during 2016-2020. PSG, demographical, clinical variables, and comorbidities were recorded. Phenotypes were constructed from PSG variables using CA. Results are shown as median (interquartile range). RESULTS: 981 subjects were studied: 41% females, age 56 years (45-66), overall AHI 23events/h (13-42) and body mass index (BMI) 30kg/m2 (27-34). Three PSG clusters were identified: Cluster 1: "Supine and obstructive apnea predominance" (433 patients, 44%). Cluster 2: "Central, REM and shorter-hypopnea predominance" (374 patients, 38%). Cluster 3: "Severe hypoxemic burden and higher wake after sleep onset" (174 patients, 18%). Based on classical OSA severity classification, subjects are distributed among the PSG clusters as severe OSA patients (AHI≥30events/h): 46% in cluster 1, 17% in cluster 2 and 36% in cluster 3; moderate OSA (15≤AHI<30events/h): 57% in cluster 1, 34% in cluster 2 and 9% in cluster 3; mild OSA (5≤AHI<15events/h): 28% in cluster 1, 68% in cluster 2 and 4% in cluster 3. CONCLUSIONS: The CA identifies three specific PSG phenotypes that do not completely agree with classical OSA severity classification. This emphasized that using a simplistic AHI approach, the OSA severity is assessed by an incorrect or incomplete analysis of the heterogeneity of the disorder.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Estudos Transversais , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Sono/fisiologia , Fenótipo
4.
ERJ Open Res ; 8(4)2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36284828

RESUMO

Introduction: Continuous positive airway pressure (CPAP) titration was dramatically affected by the coronavirus disease 2019 (COVID-19) pandemic due to increased biological risk. This study aimed to compare successful CPAP adaptation and compliance with home telemedicine CPAP titration with the usual method based on face-to-face visits. Methodology: A prospective cohort using telemedicine home CPAP titration and follow-up during the COVID-19 pandemic (TC) was compared with a retrospective cohort receiving face-to-face pre-pandemic home titration (RC). The TC included a subgroup with a smartphone application (TC-APP). Successful CPAP adaptation and compliance at 1 month of follow-up were the main endpoints, while patient satisfaction and costs were secondary endpoints. Results: 210 consecutive patients were evaluated (80 RC and 130 TC). 36 patients were in the TC-APP subgroup. CPAP titration was successful in 90% in RC versus 95% in TC and 100% in TC-APP. No compliance differences between groups were found at 1  month (4.79 h·night-1 RC, 4.33  h·night-1 TC and 4.59 h·night-1 TC-APP). Mean±sd patient satisfaction out of 10 was 7.69±2.05 in RC versus 9.02±0.64 in TC (p<0.001). 64% of the TC-APP subgroup reported that their telemedicine strategy influenced an increase in CPAP use (p=0.011). CPAP adaptation with follow-up had an estimated direct staff cost per patient of EUR 19.61±8.61 in TC with no smartphone application used versus EUR 23.79±9.94 in TC-APP (p=0.048). Conclusions: Telemedicine in CPAP titration and early follow-up is equivalent to the usual care in terms of successful adaptation and compliance, while achieving greater patient satisfaction.

SELEÇÃO DE REFERÊNCIAS