Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 43: 134-139, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195556

RESUMO

INTRODUCTION: Whereas hadron therapy of static targets is clinically established, treatment of moving organs remains a challenge. One strategy is to minimize motion of surrounding tissue mechanically and to mitigate residual motion with an appropriate irradiation technique. In this technical note, we present and characterize such an immobilization technique for a novel noncancerous application: the irradiation of small targets in hearts with scanned carbon ion beams in a porcine model for elimination of arrhythmias. MATERIAL AND METHODS: A device for immobilization was custom-built. Both for the treatment planning 4D-CT scan and for irradiation, breath-hold at end-exhale was enforced using a remotely-controlled respirator. Target motion was thus reduced to heartbeat only. Positioning was verified by orthogonal X-rays followed by couch shift if necessary. Reproducibility of bony anatomy, diaphragm, and heart position after repositioning and between repeated breath-hold maneuvers was evaluated on X-rays and cardiac-gated 4D-CTs. Treatment was post hoc simulated on sequential 4D-CTs for a subset of animals, after immediate repositioning and after a delay of one week, similar to the delay between imaging and irradiation. RESULTS: Breath-hold without repositioning was highly reproducible with an RMS deviation of at most one millimeter. 4D-CTs showed larger deformations in soft tissue, but treatment simulation on sequential images resulted in full target coverage (V95 >95%). CONCLUSION: The method of immobilization permitted reproducible positioning of mobile, thoracic targets for range-sensitive particle therapy. The presented immobilization strategy could be a reasonable approach for future animal investigations with the ultimate goal of translation to therapy in men.


Assuntos
Técnicas de Ablação , Coração/efeitos da radiação , Radioterapia com Íons Pesados , Imobilização/métodos , Animais , Tomografia Computadorizada Quadridimensional , Coração/diagnóstico por imagem , Imobilização/instrumentação , Suínos
2.
Phys Med Biol ; 62(17): 6869-6883, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28644151

RESUMO

Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R-R interval. 4D-dose calculation was performed using GSI's in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage (D95 and V95), heterogeneity (HI = D5-D95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.


Assuntos
Arritmias Cardíacas/cirurgia , Carbono/uso terapêutico , Ablação por Cateter , Eletrocardiografia , Tomografia Computadorizada Quadridimensional/métodos , Radioterapia com Íons Pesados , Animais , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Suínos
3.
Sci Rep ; 6: 38895, 2016 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-27996023

RESUMO

High-energy ion beams are successfully used in cancer therapy and precisely deliver high doses of ionizing radiation to small deep-seated target volumes. A similar noninvasive treatment modality for cardiac arrhythmias was tested here. This study used high-energy carbon ions for ablation of cardiac tissue in pigs. Doses of 25, 40, and 55 Gy were applied in forced-breath-hold to the atrioventricular junction, left atrial pulmonary vein junction, and freewall left ventricle of intact animals. Procedural success was tracked by (1.) in-beam positron-emission tomography (PET) imaging; (2.) intracardiac voltage mapping with visible lesion on ultrasound; (3.) lesion outcomes in pathohistolgy. High doses (40-55 Gy) caused slowing and interruption of cardiac impulse propagation. Target fibrosis was the main mediator of the ablation effect. In irradiated tissue, apoptosis was present after 3, but not 6 months. Our study shows feasibility to use high-energy ion beams for creation of cardiac lesions that chronically interrupt cardiac conduction.


Assuntos
Arritmias Cardíacas/radioterapia , Radioterapia de Alta Energia/métodos , Animais , Apoptose/efeitos da radiação , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/patologia , Relação Dose-Resposta à Radiação , Feminino , Masculino , Miocárdio/metabolismo , Miocárdio/patologia , Tomografia por Emissão de Pósitrons , Sus scrofa
4.
Biomed Tech (Berl) ; 60(2): 147-56, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25719279

RESUMO

Hadron therapy has already proven to be successful in cancer therapy, and might be a noninvasive alternative for the ablation of cardiac arrhythmias in humans. We present a pilot experiment investigating acute effects of a 12C irradiation on the AV nodes of porcine hearts in a Langendorff setup. This setup was adapted to the requirements of charged particle therapy. Treatment plans were computed on calibrated CTs of the hearts. Irradiation was applied in units of 5 and 10 Gy over a period of about 3 h until a total dose of up to 160 Gy was reached. Repeated application of the same irradiation field helped to mitigate motion artifacts in the resulting dose distribution. After irradiation, PET scans were performed to verify accurate dose application. Acute AV blocks were identified. No other acute effects were observed. Hearts were kept in sinus rhythm for up to 6 h in the Langendorff setup. We demonstrated that 12C ions can be used to select a small target in the heart and, thereby, influence the electrical conduction system. Second, our pilot study seems to suggest that no adverse effects have to be expected immediately during heavy ion irradiation in performing subsequent experiments with doses of 30-60 Gy and intact pigs.


Assuntos
Arritmias Cardíacas/fisiopatologia , Radioterapia com Íons Pesados/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Animais , Síndrome de Brugada , Doença do Sistema de Condução Cardíaco , Estudos de Viabilidade , Radioterapia com Íons Pesados/instrumentação , Humanos , Projetos Piloto , Suínos
5.
Circ Arrhythm Electrophysiol ; 8(2): 429-38, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25609687

RESUMO

BACKGROUND: Particle therapy, with heavy ions such as carbon-12 ((12)C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. METHODS AND RESULTS: Intact hearts were explanted from 4 (30-40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomographic scans (1 mm voxel and slice spacing) were acquired and (12)C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomographic scans for detection of ß(+) ((11)C) activity were obtained. A (12)C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomography demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. CONCLUSIONS: This is the first report of the application of a (12)C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.


Assuntos
Técnicas de Ablação , Nó Atrioventricular/efeitos da radiação , Radioterapia com Íons Pesados , Perfusão , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/instrumentação , Animais , Nó Atrioventricular/diagnóstico por imagem , Nó Atrioventricular/metabolismo , Nó Atrioventricular/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Marcadores Fiduciais , Frequência Cardíaca/efeitos da radiação , Radioterapia com Íons Pesados/efeitos adversos , Radioterapia com Íons Pesados/instrumentação , Histonas/metabolismo , Modelos Animais , Imagem Multimodal , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Miócitos Cardíacos/efeitos da radiação , Tomografia por Emissão de Pósitrons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Assistida por Computador , Sus scrofa , Tomografia Computadorizada por Raios X
6.
Acc Chem Res ; 38(1): 29-37, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15654734

RESUMO

Quantum chemical studies of cyclizations of enediynes and enyne-allenes have proven to be computationally tractable thanks to the success of the unrestricted broken spin symmetry (UBS) approach using GGA functionals for the description of open-shell biradicals; the results can further be improved through single-point energy coupled-cluster computations [CCSD(T), BD(T)]. This made comprehensive computational studies on substituent effects and heterosubstituted systems possible. For convenience and predicting new reactions, these transformations can be grouped within larger "families". Alternative cyclization modes are predicted and await experimental realization.


Assuntos
Alcenos/química , Alcinos/química , Polímeros/química , Biologia Computacional , Ciclização , Estrutura Molecular , Termodinâmica
7.
Org Lett ; 6(17): 2981-4, 2004 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-15330663

RESUMO

The cyclization reactions of polyunsaturated systems such as enediynes, enyne-allenes, as well as many others, can be structurally related to the Cope reaction and grouped into two branches: 6pi (e.g., Cope, allenyl-Cope) and [2sigma + 4pi] systems (e.g., Bergman, Myers-Saito). After extensive computional (BCCD(T)/cc-pVDZ//UBLYP/6-31G) examination of a large set of Cope-related reactions, we derive the following simple rule: biradical intermediates are involved along the reaction path if they are stabilized by allylic resonance or aromaticity.

9.
J Org Chem ; 67(5): 1453-61, 2002 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-11871873

RESUMO

Aromaticity criteria (magnetic susceptibility exaltations, nucleus independent chemical shifts (NICS), and aromatic stabilization energy (ASE) evaluations) for enediyne and enyne-allene cyclizations evaluated at (UBS)-BLYP/6-31G* all agree that the degrees of cyclic electron delocalization of the benzenoid systems formed by the Bergman (3) and Myers-Saito reactions (5) are comparable to benzene. The reaction enthalpy differences between the parent cyclizations and their benzannelated analogues are not entirely due to disparities in gained ASE during the reactions. The alternative formation of fulvene biradicals is not accompanied by favorable aromatic effects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA