Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Phytother Res ; 38(3): 1358-1366, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38200617

RESUMO

Findings on the effect of walnut consumption on endothelial function are conflicting. Therefore, the present systematic review and meta-analysis summarized available trials in this regard. A systematic search was performed in online databases including PubMed-Medline, Scopus, and ISI Web of Science up to October 2023. Articles that reported the effect of walnut intake on flow-mediated dilation (FMD), intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), and stimulus-adjusted response measure (SARM) were included. Random effects models for a weighted mean difference (WMD) or standardized mean difference (SMD) were used to test for the overall effect. Six eligible trials were analyzed (250 participants). Walnut intake significantly increased FMD (WMD: 0.94%, 95% CI: 0.12 to 1.75; p = 0.02). However, meta-analysis could not show any beneficial effect of walnut intake on ICAM-1 (SMD: -0.23, 95% CI: -0.68 to 0.22; p = 0.31), VCAM-1 (SMD: -0.02, 95% CI: -1.38 to 1.34; p = 0.97), and SARM (WMD: 0.01%, 95% CI: -0.01 to 0.04; p = 0.28). In conclusion, the present meta-analysis suggests that walnuts may reduce cardiovascular disease risk by improving FMD. However, further studies should be performed on adults to determine the effect of walnut intake on endothelial function.


Assuntos
Juglans , Adulto , Humanos , Molécula 1 de Adesão Intercelular , Nozes , Ensaios Clínicos Controlados Aleatórios como Assunto , Molécula 1 de Adesão de Célula Vascular
2.
Eur J Neurosci ; 59(2): 283-297, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38043936

RESUMO

Parkinson's disease (PD) is a neurodegenerative disorder characterized by the loss of dopaminergic neurons in the substantia nigra, leading to various motor and non-motor symptoms. Several cellular and molecular mechanisms such as alpha-synuclein (α-syn) accumulation, mitochondrial dysfunction, oxidative stress and neuroinflammation are involved in the pathogenesis of this disease. MicroRNAs (miRNAs) play important roles in post-transcriptional gene regulation. They are typically about 21-25 nucleotides in length and are involved in the regulation of gene expression by binding to the messenger RNA (mRNA) molecules. miRNAs like miR-221 play important roles in various biological processes, including development, cell proliferation, differentiation and apoptosis. miR-221 promotes neuronal survival against oxidative stress and neurite outgrowth and neuronal differentiation. Additionally, the role of miR-221 in PD has been investigated in several studies. According to the results of these studies, (1) miR-221 protects PC12 cells against oxidative stress induced by 6-hydroxydopamine; (2) miR-221 prevents Bax/caspase-3 signalling activation by stopping Bim; (3) miR-221 has moderate predictive power for PD; (4) miR-221 directly targets PTEN, and PTEN over-expression eliminates the protective action of miR-221 on p-AKT expression in PC12 cells; and (5) miRNA-221 controls cell viability and apoptosis by manipulating the Akt signalling pathway in PD. This review study suggested that miR-221 has the potential to be used as a clinical biomarker for PD diagnosis and stage assignment.


Assuntos
MicroRNAs , Doença de Parkinson , Ratos , Animais , Humanos , Doença de Parkinson/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , MicroRNAs/genética , MicroRNAs/metabolismo , Apoptose , Neurônios Dopaminérgicos/metabolismo , Biomarcadores/metabolismo
3.
Nanoscale Adv ; 5(23): 6458-6472, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38024307

RESUMO

The bactericidal effect of biomimetic nanostructured surfaces has been known for a long time, with recent data suggesting an enhanced efficiency of the nanostructured surfaces under fluid shear. While some of the influential factors on the bactericidal effect of nanostructured surfaces under fluid shear are understood, there are numerous important factors yet to be studied, which is essential for the successful implementation of this technology in industrial applications. Among those influential factors, the orientation of the nanostructured surface can play an important role in bacterial cell adhesion onto surfaces. Gravitational effects can become dominant under low flow velocities, making the diffusive transport of bacterial cells more prominent than the advective transport. However, the role of nanostructure orientation in determining its bactericidal efficiency under flow conditions is still not clear. In this study, we analysed the effect of surface orientation of nanostructured surfaces, along with bacterial cell concentration, fluid flow rate, and the duration of time which the surface is exposed to flow, on bacterial adhesion and viability on these surfaces. Two surface orientations, with one on the top and the other on the bottom of a flow channel, were studied. Under flow conditions, the bactericidal efficacy of the nanostructured surface is both orientation and bacterial species dependent. The effects of cell concentration, fluid flow rate, and exposure time on cell adhesion are independent of the nanostructured surface orientation. Fluid shear showed a species-dependent effect on bacterial adhesion, while the effects of concentration and exposure time on bacterial cell adhesion are independent of the bacterial species. Moreover, bacterial cells demonstrate preferential adhesion onto surfaces based on the surface orientation, and these effects are species dependent. These results outline the capabilities and limitations of nanostructures under flow conditions. This provides valuable insights into the applications of nanostructures in medical or industrial sectors, which are associated with overlaying fluid flow.

4.
Nanomaterials (Basel) ; 13(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37887949

RESUMO

Bacterial infections and antibiotic resistance remain significant contributors to morbidity and mortality worldwide. Despite recent advances in biomedical research, a substantial number of medical devices and implants continue to be plagued by bacterial colonisation, resulting in severe consequences, including fatalities. The development of nanostructured surfaces with mechano-bactericidal properties has emerged as a promising solution to this problem. These surfaces employ a mechanical rupturing mechanism to lyse bacterial cells, effectively halting subsequent biofilm formation on various materials and, ultimately, thwarting bacterial infections. This review delves into the prevailing research progress within the realm of nanostructured mechano-bactericidal polymeric surfaces. It also investigates the diverse fabrication methods for developing nanostructured polymeric surfaces with mechano-bactericidal properties. We then discuss the significant challenges associated with each approach and identify research gaps that warrant exploration in future studies, emphasizing the potential for polymeric implants to leverage their distinct physical, chemical, and mechanical properties over traditional materials like metals.

5.
J Colloid Interface Sci ; 652(Pt B): 2127-2138, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37703682

RESUMO

Understanding how bacteria interact with surfaces with micrometer and/or sub-micrometer roughness is critical for developing antibiofouling and bactericidal topographies. A primary research focus in this field has been replicating and emulating bioinspired nanostructures on various substrates to investigate their mechanobactericidal potential. Yet, reports on polymer substrates, especially with very high aspect ratios, have been rare, despite their widespread use in our daily lives. Specifically, the role of a decrease in stiffness with an increase in the aspect ratio of nanostructures may be consequential for the mechanobactericidal mechanism, which is biophysical in nature. Therefore, this work reports on generating bioinspired high aspect ratio nanostructures on poly(ethylene terephthalate) (PET) surfaces to study and elucidate their antibacterial and antibiofouling properties. Biomimetic nanotopographies with variable aspect ratios were generated via maskless dry etching of PET in oxygen plasma. It was found that both high and low-aspect ratio structures effectively neutralized Gram-negative bacterial contamination by imparting damage to their membranes but were unable to inactivate Gram-positive cells. Notably, the clustering of the soft, flexible tall nanopillars resulted in cooperative stiffening, as revealed by the nanomechanical behavior of the nanostructures and validated with the help of finite element simulations. Moreover, external capillary forces augmented the killing efficiency by enhancing the strain on the bacterial cell wall. Finally, experimental and computational investigation of the durability of the nanostructured surfaces showed that the structures were robust enough to withstand forces encountered in daily life. Our results demonstrate the potential of the single-step dry etching method for the fabrication of mechanobactericidal topographies and their potential in a wide variety of applications to minimize bacterial colonization of soft substrates like polymers.

6.
J Eat Disord ; 11(1): 90, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37277839

RESUMO

BACKGROUND: Previous studies have shown that physical appearance perfectionism could play an important role in social physique anxiety; however, the moderating role of body compassion has not been studied. The current study aims to explore the moderating role of body compassion in the relationship between physical appearance perfectionism and social physique anxiety in undergraduate students. METHODS: A sample of 418 undergraduates (n = 418; 217 female and 201 males) from three universities in Tehran, Iran completed online questionnaires measuring physical appearance perfectionism, body compassion and social physique anxiety. RESULTS: The results of structural equation modeling showed that physical appearance perfectionism (ß = 0.68, p < 0.001) positively predicted the social physique anxiety and body compassion negatively predicted (ß = - .56, p < 0.001) the social physique anxiety in undergraduate students. A multi-group analysis showed that body compassion acted as a moderator between physical appearance perfectionism and social physique anxiety. CONCLUSIONS: The results suggested that individuals with greater levels of physical appearance perfectionism are more likely to experience social physique anxiety. Also, the results suggested that individuals who were at a high level of the body-compassion group experienced lower levels of social physical anxiety if they also had high levels of physical appearance perfectionism. Therefore, body-compassion acted as a protective role in the relationship between physical appearance perfectionism and social physique anxiety.


Anxiety over one's physical appearance in social situations is known as social physique anxiety. One of the variables that plays an important role social physique anxiety is physical appearance perfectionism. General perfectionism, body dissatisfaction, the symptoms of eating disorders and muscle dysmorphia and obsessive exercise are all linked to physical appearance perfectionism. The results of the current study showed individuals with high levels of physical appearance perfectionism are more likely to experience social physique anxiety. In the current study, we tested the moderating role of self-compassion in the relationship between physical appearance perfectionism and social physique anxiety. Body compassion is characterized by diffusion, common humanity, and acceptance of one's own body as opposed to being judgmental, critical, isolated, and over-identifying with unpleasant experiences and emotions. The findings showed in the group with high body- compassion, the relationship between physical appearance perfectionism and social physique anxiety was not significant, which means that body-compassion played a buffering role in this relationship.

7.
Micromachines (Basel) ; 14(5)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37241553

RESUMO

Microfluidic organ-on-a-chip (OoC) technology has enabled studies on dynamic physiological conditions as well as being deployed in drug testing applications. A microfluidic pump is an essential component to perform perfusion cell culture in OoC devices. However, it is challenging to have a single pump that can fulfil both the customization function needed to mimic a myriad of physiological flow rates and profiles found in vivo and multiplexing requirements (i.e., low cost, small footprint) for drug testing operations. The advent of 3D printing technology and open-source programmable electronic controllers presents an opportunity to democratize the fabrication of mini-peristaltic pumps suitable for microfluidic applications at a fraction of the cost of commercial microfluidic pumps. However, existing 3D-printed peristaltic pumps have mainly focused on demonstrating the feasibility of using 3D printing to fabricate the structural components of the pump and neglected user experience and customization capability. Here, we present a user-centric programmable 3D-printed mini-peristaltic pump with a compact design and low manufacturing cost (~USD 175) suitable for perfusion OoC culture applications. The pump consists of a user-friendly, wired electronic module that controls the operation of a peristaltic pump module. The peristaltic pump module comprises an air-sealed stepper motor connected to a 3D-printed peristaltic assembly, which can withstand the high-humidity environment of a cell culture incubator. We demonstrated that this pump allows users to either program the electronic module or use different-sized tubing to deliver a wide range of flow rates and flow profiles. The pump also has multiplexing capability as it can accommodate multiple tubing. The performance and user-friendliness of this low-cost, compact pump can be easily deployed for various OoC applications.

8.
Front Psychol ; 14: 1069402, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063549

RESUMO

In the present study, the researchers reported the results of an empirical study on remote working and occupational stress and their effects on employees' job satisfaction, motivation, and performance. Remote working has three subscales: self-proficiency, technology, and teamwork. Intrinsic and extrinsic motivation subscales were included to assess employee motivation. A simple random sampling method was used to select the subjects who are employees of the IT-enabled industries in Hyderabad Metro. A total of 513 responses were obtained on the remote working subscales-the effect on the independent variables, namely, employee self-proficiency, technology, teamwork, and occupational stress, on the dependent variables, namely, job satisfaction, intrinsic motivation, extrinsic motivation, and performance. The measured Cronbach's alpha was in the range of 0.64-0.77, other reliability statistics split-half (odd-even) correlation was in the range of 0.62-0.84, and theSpearman-Brown prophecy was in the range of 0.70-0.91, demonstrating the reliability and internal consistency of the research instrument. The general linear model results indicated that all the independent variables, namely, self-proficiency, teamwork, and Occupational stress, are statistically significant and influence the outcome variables. The general linear model results also indicated statistically significant age differences in the dependent variables; however, there were no statistically significant gender differences. Of the independent variables, self-proficiency influences job satisfaction, intrinsic motivation, and performance (p < 0.01); teamwork influences employee job satisfaction and extrinsic motivation (p < 0.01 and p < 0.05); and Occupational stress influences performance (p < 0.01), which are statistically significant and thus influence the outcome variables. The model predicted a statistically significant influence of age (p < 0.01) on all the dependent factors, namely, job satisfaction, intrinsic motivation, extrinsic motivation, and performance. The study revealed that remote working is one of the major factors causing anxiety and employee stress. The main reasons are the absence of interaction with peers, the absence of routine fun during breaks, and work-family conflicts. Another observation is that the absence of peer-employee interaction demotivates the employees as there is no competition among the employees during remote working. The authors recommend that organizations develop an integrated human resource policy and performance management system that addresses the issues of employee stress, remote working concerns, peer-employee interactions, and pandemic-type situations. As there are several factors such as occupational stress, job satisfaction, motivation, peer interactions, and remote working concerns, employee stress-coping strategies affect the performance of an employee. The multiple mediation analysis indicates no statistically significant influence of the mediator variables, i.e., occupational stress and job satisfaction, on performance through remote working.

9.
Molecules ; 28(5)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36903429

RESUMO

Inspired by nature, it is envisaged that a nanorough surface exhibits bactericidal properties by rupturing bacterial cells. In order to study the interaction mechanism between the cell membrane of a bacteria and a nanospike at the contact point, a finite element model was developed using the ABAQUS software package. The model, which saw a quarter of a gram-negative bacteria (Escherichia coli) cell membrane adhered to a 3 × 6 array of nanospikes, was validated by the published results, which show a reasonably good agreement with the model. The stress and strain development in the cell membrane was modeled and were observed to be spatially linear and temporally nonlinear. From the study, it was observed that the bacterial cell wall was deformed around the location of the nanospike tips as full contact was generated. Around the contact point, the principal stress reached above the critical stress leading to a creep deformation that is expected to cause cell rupture by penetrating the nanospike, and the mechanism is envisaged to be somewhat similar to that of a paper punching machine. The obtained results in this project can provide an insight on how bacterial cells of a specific species are deformed when they adhere to nanospikes, and how it is ruptured using this mechanism.


Assuntos
Antibacterianos , Bactérias Gram-Negativas , Análise de Elementos Finitos
10.
Sci Rep ; 13(1): 219, 2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36604495

RESUMO

Computational fluid dynamics (CFD) simulations are increasingly utilised to evaluate intracranial aneurysm (IA) haemodynamics to aid in the prediction of morphological changes and rupture risk. However, these models vary and differences in published results warrant the investigation of IA-CFD reproducibility. This study aims to explore sources of intra-team variability and determine its impact on the aneurysm morphology and CFD parameters. A team of four operators were given six sets of magnetic resonance angiography data spanning a decade from one patient with a middle cerebral aneurysm. All operators were given the same protocol and software for model reconstruction and numerical analysis. The morphology and haemodynamics of the operator models were then compared. The segmentation, smoothing factor, inlet and outflow branch lengths were found to cause intra-team variability. There was 80% reproducibility in the time-averaged wall shear stress distribution among operators with the major difference attributed to the level of smoothing. Based on these findings, it was concluded that the clinical applicability of CFD simulations may be feasible if a standardised segmentation protocol is developed. Moreover, when analysing the aneurysm shape change over a decade, it was noted that the co-existence of positive and negative values of the wall shear stress divergence (WSSD) contributed to the growth of a daughter sac.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/complicações , Hidrodinâmica , Reprodutibilidade dos Testes , Hemodinâmica , Angiografia por Ressonância Magnética , Estresse Mecânico
11.
Mater Today Proc ; 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38620140

RESUMO

The spread of respiratory diseases has gained significant attention since the detection and rapid global spread of COVID-19. Respiratory viruses are commonly transmitted when an infected person coughs or sneezes onto a surface, infecting persons who subsequently contact this surface. For this reason, developing surfaces with inherent antipathogenic properties is crucially needed for controlling the spread of deadly pathogens. Recent studies have established the antipathogenic potential of hydrothermally synthesised titanium dioxide (TiO2) nanostructured surfaces against bacteria strains (Gram-positive and negative) and several respiratory viruses, including SARS-CoV-2, HRV-16 and HCoV-NL63. This study investigates the antiviral behaviour of TiO2 nanostructured surfaces against Respiratory Syncytial Virus (RSV), a respiratory virus commonly contracted by children, to reduce viral transmission in high-traffic environments such as hospitals and childcare centers. Mimicking droplets produced when a person coughs or sneezes, RSV droplets were exposed to nanostructured surfaces to investigate their antiviral potential. Results show that nanostructured TiO2 reduced the RSV infectious viral load at all timepoints compared to control surfaces, showing 1.7, 2.6 and 3.2 log reductions after 2-, 5- and 7-hours exposure, respectively. Interestingly, virus exposed to nanostructured surfaces showed little to no infectivity after 5 h exposure while viable virus was still detected on control surfaces after 7 h exposure. These encouraging results establish TiO2 nanostructured surfaces as a potential method for reducing transmission and spread of respiratory viruses and bacterial strains.

12.
ACS Omega ; 7(45): 41711-41722, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36406483

RESUMO

Bacterial colonization on solid surfaces creates enormous problems across various industries causing billions of dollars' worth of economic damages and costing human lives. Biomimicking nanostructured surfaces have demonstrated a promising future in mitigating bacterial colonization and related issues. The importance of this non-chemical method has been elevated due to bacterial evolvement into antibiotic and antiseptic-resistant strains. However, bacterial attachment and viability on nanostructured surfaces under fluid flow conditions has not been investigated thoroughly. In this study, attachment and viability of Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus) on a model nanostructured surface were studied under fluid flow conditions. A wide range of flow rates resulting in a broad spectrum of fluid wall shear stress on a nanostructured surface representing various application conditions were experimentally investigated. The bacterial suspension was pumped through a custom-designed microfluidic device (MFD) that contains a sterile Ti-6Al-4V substrate. The surface of the titanium substrate was modified using a hydrothermal synthesis process to fabricate the nanowire structure on the surface. The results of the current study show that the fluid flow significantly reduces bacterial adhesion onto nanostructured surfaces and significantly reduces the viability of adherent cells. Interestingly, the bactericidal efficacy of the nanostructured surface was increased under the flow by ∼1.5-fold against P. aeruginosa and ∼3-fold against S. aureus under static conditions. The bactericidal efficacy had no dependency on the fluid wall shear stress level. However, trends in the dead-cell count with the fluid wall shear were slightly different between the two species. These findings will be highly useful in developing and optimizing nanostructures in the laboratory as well as translating them into successful industrial applications. These findings may be used to develop antibacterial surfaces on biomedical equipment such as catheters and vascular stents or industrial applications such as ship hulls and pipelines where bacterial colonization is a great challenge.

13.
ACS Omega ; 7(27): 23201-23212, 2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35847259

RESUMO

Nanotopographic surfaces are proven to be successful in killing bacterial cells upon contact. This non-chemical bactericidal property has paved an alternative way of fighting bacterial colonization and associated problems, especially the issue of bacteria evolving resistance against antibiotic and antiseptic agents. Recent advancements in nanotopographic bactericidal surfaces have made them suitable for many applications in medical and industrial sectors. The bactericidal effect of nanotopographic surfaces is classically studied under static conditions, but the actual potential applications do have fluid flow in them. In this study, we have studied how fluid flow can affect the adherence of bacterial cells on nanotopographic surfaces. Gram-positive and Gram-negative bacterial species were tested under varying fluid flow rates for their retention and viability after flow exposure. The total number of adherent cells for both species was reduced in the presence of flow, but there was no flowrate dependency. There was a significant reduction in the number of live cells remaining on nanotopographic surfaces with an increasing flowrate for both species. Conversely, we observed a flowrate-independent increase in the number of adherent dead cells. Our results indicated that the presence of flow differentially affected the adherent live and dead bacterial cells on nanotopographic surfaces. This could be because dead bacterial cells were physically pierced by the nano-features, whereas live cells adhered via physiochemical interactions with the surface. Therefore, fluid shear was insufficient to overcome adhesion forces between the surface and dead cells. Furthermore, hydrodynamic forces due to the flow can cause more planktonic and detached live cells to collide with nano-features on the surface, causing more cells to lyse. These results show that nanotopographic surfaces do not have self-cleaning ability as opposed to natural bactericidal nanotopographic surfaces, and nanotopographic surfaces tend to perform better under flow conditions. These findings are highly useful for developing and optimizing nanotopographic surfaces for medical and industrial applications.

14.
Healthcare (Basel) ; 10(5)2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35627963

RESUMO

Health care is uncertain, dynamic, and fast growing. With digital technologies set to revolutionise the industry, hospital capacity optimisation and planning have never been more relevant. The purposes of this article are threefold. The first is to identify the current state of the art, to summarise/analyse the key achievements, and to identify gaps in the body of research. The second is to synthesise and evaluate that literature to create a holistic framework for understanding hospital capacity planning and optimisation, in terms of physical elements, process, and governance. Third, avenues for future research are sought to inform researchers and practitioners where they should best concentrate their efforts. In conclusion, we find that prior research has typically focussed on individual parts, but the hospital is one body that is made up of many interdependent parts. It is also evident that past attempts considering entire hospitals fail to incorporate all the detail that is necessary to provide solutions that can be implemented in the real world, across strategic, tactical and operational planning horizons. A holistic approach is needed that includes ancillary services, equipment medicines, utilities, instrument trays, supply chain and inventory considerations.

15.
Nanomaterials (Basel) ; 11(10)2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34684913

RESUMO

Nanopatterned surfaces administer antibacterial activity through contact-induced mechanical stresses and strains, which can be modulated by changing the nanopattern's radius, spacing and height. However, due to conflicting recommendations throughout the theoretical literature with poor agreement to reported experimental trends, it remains unclear whether these key dimensions-particularly radius and spacing-should be increased or decreased to maximize bactericidal efficiency. It is shown here that a potential failure of biophysical models lies in neglecting any out-of-plane effects of nanopattern contact. To highlight this, stresses induced by a nanopattern were studied via an analytical model based on minimization of strain and adhesion energy. The in-plane (areal) and out-of-plane (contact pressure) stresses at equilibrium were derived, as well as a combined stress (von Mises), which comprises both. Contour plots were produced to illustrate which nanopatterns elicited the highest stresses over all combinations of tip radius between 0 and 100 nm and center spacing between 0 and 200 nm. Considering both the in-plane and out-of-plane stresses drastically transformed the contour plots from those when only in-plane stress was evaluated, clearly favoring small tipped, tightly packed nanopatterns. In addition, the effect of changes to radius and spacing in terms of the combined stress showed the best qualitative agreement with previous reported trends in killing efficiency. Together, the results affirm that the killing efficiency of a nanopattern can be maximized by simultaneous reduction in tip radius and increase in nanopattern packing ratio (i.e., radius/spacing). These findings provide a guide for the design of highly bactericidal nanopatterned surfaces.

16.
Cerebrovasc Dis ; 50(5): 510-519, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33951645

RESUMO

BACKGROUND AND PURPOSE: The hemodynamic environment of an atherosclerotic plaque varies along the longitudinal direction. Investigating the changes in plaque morphology and its biomechanical environment along the longitudinal direction and their correlations will enhance our understanding of plaque progression and arterial remodeling. METHODS: Six male patients with carotid stenosis >70% were recruited. Multisequence high-resolution MRI was performed at the carotid bifurcation. Carotid endarterectomy was performed following MRI, and the plaque tissue was collected for histological and mechanical testing. Patient-specific biomechanical modeling and simulations were conducted to calculate the mechanical stresses (wall shear stress [WSS] and von Mises stress [VMS]). Changes in plaque cross-sectional morphology, WSS, and VMS as well as their correlations were evaluated. RESULTS: Positive correlations were found between % stenosis and % inflammation (MA) (p = 0.019), % lipid area and % MA (p = 0.026), and % calcification area and VMS (p = 0.007). Negative correlations were found between VMS and % stenosis (p = 0.028) and VMS and average WSS (p = 0.034). Moreover, the peak stresses and neovessels were found to be in the shoulder regions. High-stress concentrations were found in the interface regions of the calcification and surrounding tissue, thereby increasing plaque vulnerability. CONCLUSIONS: Correlations between the morphology and stresses suggest that arterial remodeling is a dynamic interaction between mechanical environment and plaque progression resulting in plaque heterogeneity. Our finding indicates that plaque heterogeneity is associated with plaque progression and can be combined with mechanical stresses for identifying high-risk plaques.


Assuntos
Artérias Carótidas/fisiopatologia , Estenose das Carótidas/fisiopatologia , Hemodinâmica , Mecanotransdução Celular , Placa Aterosclerótica , Remodelação Vascular , Fenômenos Biomecânicos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Progressão da Doença , Endarterectomia das Carótidas , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética , Masculino , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Ruptura Espontânea , Estresse Mecânico
17.
J Mech Behav Biomed Mater ; 119: 104552, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33934037

RESUMO

As the global trauma fixation devices market expands rapidly, it is imperative to improve the production of fixation devices through enhanced design accuracy and fit for best performance and maximum patient comfort. Selective laser melting (SLM) is one of the mature additive manufacturing methods, which provides a viable route for the rapid production of such devices. In this work, the ability of SLM to produce near-net-shape parts, as desired for medical implants, was utilized for the fabrication of bone plates from Ti-6Al-4V alloy powder. Martensitic microstructure obtained after the printing of alloy resulted in poor ductility, limiting its application in the field of orthopedics. A specially designed repeated cyclic heating and cooling close to but below the ß-transus was used to transform from acicular to a bimodal microstructure without the need for plastic deformation prior to heat treatment for improving the ductility. Bone plates subjected to this heat treatment were mechanically tested by means of tensile and 3-point bend tests and demonstrated large improvement in ductility, and the values were comparable to those similar plates prepared from wrought alloy. Other important properties required for implants were assessed, such as corrosion resistance in simulated body fluid and cytocompatibility in vitro using MC3T3-E1 cells. These results for the bone plate after heat treatment were excellent and similar to those of the additively manufactured and wrought plates. Taken together, the performance of the additively manufactured bone plates after subjecting to heat treatment was similar to those of bone plate manufactured using wrought alloy. These results have important implications for the fabrication of patient-specific metallic orthopedic devices using SLM without compromising their biomechanical performance by subjecting them to a tailored heat treatment.


Assuntos
Placas Ósseas , Titânio , Ligas , Humanos , Próteses e Implantes , Resistência à Tração
18.
Biophys J ; 120(2): 217-231, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33333030

RESUMO

Nanopatterned surfaces are believed to kill bacteria through physical deformation, a mechanism that has immense potential against biochemical resistance. Because of its elusive nature, this mechanism is mostly understood through biophysical modeling. Problematically, accurate descriptions of the contact mechanics and various boundary conditions involved in the bacteria-nanopattern interaction remain to be seen. This may underpin conflicting predictions, found throughout the literature, regarding two important aspects of the mechanism-that is, its critical action site and relationship with geometry. Herein, a robust computational analysis of bacteria-nanopattern interaction is performed using a three-dimensional finite element modeling that incorporates relevant continuum mechanical properties, multilayered envelope structure, and adhesion interaction conditions. The model is applied to more accurately study the elusory mechanism and its enhancement via nanopattern geometry. Additionally, micrographs of bacteria adhered on a nanopatterned cicada wing are examined to further inform and verify the major modeling predictions. Together, the results indicate that nanopatterned surfaces do not kill bacteria predominantly by rupture in between protruding pillars as previously thought. Instead, nondevelopable deformation about pillar tips is more likely to create a critical site at the pillar apex, which delivers significant in-plane strains and may locally rupture and penetrate the cell. The computational analysis also demonstrates that envelope deformation is increased by adhesion to nanopatterns with smaller pillar radii and spacing. These results further progress understanding of the mechanism of nanopatterned surfaces and help guide their design for enhanced bactericidal efficiency.


Assuntos
Bactérias , Hemípteros , Animais , Antibacterianos , Asas de Animais
19.
ACS Appl Bio Mater ; 4(10): 7626-7642, 2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-35006714

RESUMO

Since the discovery of the bactericidal properties of cicada wing surfaces, there has been a surge in the number of studies involving antibacterial nanostructured surfaces (NSS). Studies show that there are many parameters (and thus, thousands of parameter combinations) that influence the bactericidal efficiency (BE) of these surfaces. Researchers attempted to correlate these parameters to BE but have so far been unsuccessful. This paper presents a meta-analysis and perspective on bactericidal NSS, aiming to identify trends and gaps in the literature and to provide insights for future research. We have attempted to synthesize data from a wide range of published studies and establish trends in the literature on bactericidal NSS. Numerous research gaps and findings based on correlations of various parameters are presented here, which will assist in the design of efficient bactericidal NSS and shape future research. Traditionally, it is accepted that BE of NSS depends on the bacterial Gram-stain type. However, this review found that factors beyond Gram-stain type are also influential. Furthermore, it is found that despite their higher BE, hydrophobic NSS are less commonly studied for their bactericidal effect. Interestingly, the impacts of surface hydrophobicity and roughness on the bactericidal effect were found to be influenced by a Gram-stain type of the tested bacteria. In addition, cell motility and shape influence BE, but research attention into these factors is lacking. It was found that hydrophobic NSS demonstrate more promising results than their hydrophilic counterparts; however, these surfaces have been overlooked. Confirming the common belief of the influence of nanofeature diameter on bactericidal property, this analysis shows the feature aspect ratio is also decisive. NSS fabricated on silicon substrates perform better than their titanium counterparts, and the success of these silicon structures maybe attributed to the fabrication processes. These insights benefit engineers and scientists alike in developing next-generation NSS.


Assuntos
Nanoestruturas , Silício , Animais , Antibacterianos/farmacologia , Bactérias , Nanoestruturas/química , Silício/farmacologia , Propriedades de Superfície
20.
Artigo em Inglês | MEDLINE | ID: mdl-32117939

RESUMO

Atherosclerotic plaque rupture is a catastrophic event that contributes to mortality and long-term disability. A better understanding of the plaque mechanical behavior is essential for the identification of vulnerable plaques pre-rupture. Plaque is subjected to a natural dynamic mechanical environment under hemodynamic loading. Therefore, it is important to understand the mechanical response of plaque tissue under cyclic loading conditions. Moreover, experimental data of such mechanical properties are fundamental for more clinically relevant biomechanical modeling and numerical simulations for risk stratification. This study aims to experimentally and numerically characterize the stress-relaxation and cyclic mechanical behavior of carotid plaque tissue. Instron microtester equipped with a custom-developed setup was used for the experiments. Carotid plaque samples excised at endarterectomy were subjected to uniaxial tensile, stress-relaxation, and cyclic loading protocols. Thirty percent of the underlying load level obtained from the uniaxial tensile test results was used to determine the change in mechanical properties of the tissue over time under a controlled testing environment (Control tests). The stress-relaxation test data was used to calibrate the hyperelastic (neo-Hookean, Ogden, Yeoh) and linear viscoelastic (Prony series) material parameters. The normalized relaxation force increased initially and slowly stabilized toward the end of relaxation phase, highlighting the viscoelastic behavior. During the cyclic tests, there was a decrease in the peak force as a function of the cycle number indicating mechanical distension due to repeated loading that varied with different frequencies. The material also accumulated residual deformation, which increased with the cycle number. This trend showed softening behavior of the samples. The results of this preliminary study provide an enhanced understanding of in vivo stress-relaxation and cyclic behavior of the human atherosclerotic plaque tissue.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA