Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38449430

RESUMO

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Arritmias Cardíacas/terapia , Frequência Cardíaca/fisiologia
2.
Heart Rhythm ; 19(2): 228-234, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757189

RESUMO

BACKGROUND: Early results from the Micra investigational trial and Micra Post-Approval Registry (PAR) demonstrated excellent safety and device performance; however, outcomes based on anticoagulation (AC) status at implant have not been evaluated. OBJECTIVE: The purpose of this study was to report implant characteristics, perforation rate, and vascular-related events based on perioperative oral AC strategy in patients undergoing Micra implant. METHODS: We compared procedure characteristics, major complications, and vascular events, including pericardial effusion, stratified by any adverse event (including major complications, minor complications, and observations) or major complication only according to AC status in the Micra PAR. RESULTS: Among 1795 patients with AC status available, 585 were not on AC, 795 had AC interrupted, and 415 had AC continued during Micra implant. Non-AC patients tended to be younger, with less history of atrial fibrillation and chronic obstructive pulmonary disease, and more history of dialysis than interrupted and continued patients. The implant success rate was similar for all groups (99.1%-99.8%). Through 30 days postimplant, the overall major complication rate was 3.1% for the non-AC group, 2.6% for the interrupted group, and 1.5% for the continued group. The combined rate for any vascular or pericardial effusion adverse event did not differ significantly among AC strategies (6.5%, 4.8%, and 3.6%, respectively). CONCLUSION: Implant of Micra seems to be safe and feasible regardless of an interrupted or continued periprocedural oral AC strategy, with no increased risk of perforation or vascular complications.


Assuntos
Anticoagulantes/administração & dosagem , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Desenho de Prótese , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA