Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Cancer Radiother ; 28(2): 195-201, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38599941

RESUMO

PURPOSE: Preclinical data demonstrated that the use of proton minibeam radiotherapy reduces the risk of toxicity in healthy tissue. Ventricular tachycardia radioablation is an area under clinical investigation in proton beam therapy. We sought to simulate a ventricular tachycardia radioablation with proton minibeams and to demonstrate that it was possible to obtain a homogeneous coverage of an arrhythmogenic cardiac zone with this technique. MATERIAL AND METHODS: An arrhythmogenic target volume was defined on the simulation CT scan of a patient, localized in the lateral wall of the left ventricle. A dose of 25Gy was planned to be delivered by proton minibeam radiotherapy, simulated using a Monte Carlo code (TOPAS v.3.7) with a collimator of 19 0.4 mm-wide slits spaced 3mm apart. The main objective of the study was to obtain a plan ensuring at least 93% of the prescription dose in 93% of the planning target volume without exceeding 110% of the prescribed dose in the planning target volume. RESULTS: The average dose in the planning treatment volume in proton minibeam radiotherapy was 25.12Gy. The percentage of the planning target volume receiving 93% (V93%), 110% (V110%), and 95% (V95%) of the prescribed dose was 94.25%, 0%, and 92.6% respectively. The lateral penumbra was 6.6mm. The mean value of the peak-to-valley-dose ratio in the planning target volume was 1.06. The mean heart dose was 2.54Gy versus 5.95Gy with stereotactic photon beam irradiation. CONCLUSION: This proof-of-concept study shows that proton minibeam radiotherapy can achieve a homogeneous coverage of an arrhythmogenic cardiac zone, reducing the dose at the normal tissues. This technique, ensuring could theoretically reduce the risk of late pulmonary and breast fibrosis, as well as cardiac toxicity as seen in previous biological studies in proton minibeam radiotherapy.


Assuntos
Terapia com Prótons , Prótons , Humanos , Estudos de Viabilidade , Terapia com Prótons/métodos , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Método de Monte Carlo
2.
Cancer Radiother ; 27(6-7): 499-503, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37482463

RESUMO

PURPOSE: The RadioTransNet project is a French initiative structuring preclinical and translational research in radiation therapy for cancer at national level. The network's activities are organized around four chosen priorities, which are: target definition, normal tissue, combined treatments and dose modelling. The subtargets linked to these four major priorities are unlimited. They include all aspects associated with fundamental radiobiology, preclinical studies, imaging, medical physics research and transversal components clearly related to these scientific areas, such as medical oncology, radio-diagnostics, nuclear medicine and cost-effectiveness considerations. METHOD: During its first phase of activity, four workshops following the consensus conference model and based on scientific and medical state of the art in radiotherapy and radiobiology were organized on the four above-mentioned objectives to identify key points. Then a road map has been defined and served as the basis for the opening in 2022 of a dedicated call, SEQ-RTH22, proposed by the French cancer national institute (INCa). RESULTS: Four research projects submitted by RadioTransNet partners have been selected to be supported by INCa: the first by Professor Anne Laprie from Oncopole Claudius-Regaud and Inserm ToNic in Toulouse on neurocognition and health after pediatric irradiation, the second submitted by Fabien Milliat from IRSN aims to study decryption and targeting of endothelial cell-immune cells interactions to limit radiation-induced intestinal toxicity, the third project, submitted by Yolanda Prezado from institut Curie-CNRS on proton minibeam radiotherapy as a new approach to reduce toxicity, and the latest project proposed by R. de Crevoisier from centre Eugène-Marquis in Rennes on predictive multiscale models of head and neck radiotoxicity induced for optimized personalized radiation therapy. Topics of each of these projects are presented here. CONCLUSION: RadioTransNet project has been launched in 2018, supported by INCa, in order to structure and promote preclinical research in oncology radiotherapy and to favor collaboration between the actors of this research. INCa relied on RadioTransNet initiatives and activities, resulting in the opening of dedicated call for projects. Beyond its first main goals, RadioTransNet network is able to help to fund the human and technical resources necessary to conduct optimal translational and preclinical research in radiation oncology.


Assuntos
Neoplasias , Lesões por Radiação , Radioterapia (Especialidade) , Humanos , Criança , Neoplasias/radioterapia , Radiobiologia
3.
Clin Transl Radiat Oncol ; 40: 100605, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36910025

RESUMO

•Improvement of therapeutic ratio by novel unconventional radiotherapy approaches.•Immunomodulation using high-dose spatially fractionated radiotherapy.•Boosting radiation anti-tumor effects by adding an immune-mediated cell killing.

4.
Phys Med Biol ; 66(22)2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34673555

RESUMO

The Orsay Proton therapy Center (ICPO) has a long history of intracranial radiotherapy using both double scattering (DS) and pencil beam scanning (PBS) techniques, and is actively investigating a promising modality of spatially fractionated radiotherapy using proton minibeams (pMBRT). This work provides a comprehensive comparison of the organ-specific secondary neutron dose due to each of these treatment modalities, assessed using Monte Carlo (MC) algorithms and measurements. A MC model of a universal nozzle was benchmarked by comparing the neutron ambient dose equivalent,H*(10), in the gantry room with measurements obtained using a WENDI-II counter. The secondary neutron dose was evaluated for clinically relevant intracranial treatments of patients of different ages, in which secondary neutron doses were scored in anthropomorphic phantoms merged with the patients' images. The MC calculatedH*(10) values showed a reasonable agreement with the measurements and followed the expected tendency, in which PBS yields the lowest dose, followed by pMBRT and DS. Our results for intracranial treatments show that pMBRT yielded a higher secondary neutron dose for organs closer to the target volume, while organs situated furthest from the target volume received a greater quantity of neutrons from the passive scattering beam line. To the best of our knowledge, this is the first study to compare MC secondary neutron dose estimates in clinical treatments between these various proton therapy modalities and to realistically quantify the secondary neutron dose contribution of clinical pMBRT treatments. The method established in this study will enable epidemiological studies of the long-term effects of intracranial treatments at ICPO, notably radiation-induced second malignancies.


Assuntos
Neoplasias Induzidas por Radiação , Terapia com Prótons , Humanos , Método de Monte Carlo , Nêutrons , Imagens de Fantasmas , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica
5.
Sci Rep ; 10(1): 7025, 2020 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-32341427

RESUMO

Proton minibeam radiation therapy (pMBRT) is a novel dose delivery method based on spatial dose fractionation. pMBRT has been shown to be promising in terms of reduced side effects and superior tumour control in high-grade glioma-bearing rats compared to standard irradiation. These findings, together with the recent optimized implementation of pMBRT in a clinical pencil beam scanning system, have triggered reflection on the possible application to patient treatments. In this context, the present study was designed to conduct a first theoretical investigation of the clinical potential of this technique. For this purpose, a dedicated dose engine was developed and used to evaluate two clinically relevant patient treatment plans (high-grade glioma and meningioma). Treatment plans were compared with standard proton therapy plans assessed by means of a commercial treatment planning system (ECLIPSE-Varian Medical systems) and Monte Carlo simulations. A multislit brass collimator consisting of 0.4 mm wide slits separated by a centre-to-centre distance of 4 or 6 mm was placed between the nozzle and the patient to shape the planar minibeams. For each plan, spread-out Bragg peaks and homogeneous dose distributions (±7% dose variations) can be obtained in target volumes. The Peak-to-Valley Dose Ratios (PVDR) were evaluated between 9.2 and 12.8 at a depth of 20 mm for meningioma and glioma, respectively. Dose volume histograms (DVHs) for target volumes and organs at risk were quantitatively compared, resulting in a slightly better target homogeneity with standard PT than with pMBRT plans, but similar DVHs for deep-seated organs-at-risk and lower average dose for shallow organs. The proposed delivery method evaluated in this work opens the way to an effective treatment for radioresistant tumours and will support the design of future clinical research.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Prótons , Dosagem Radioterapêutica
6.
Phys Med ; 69: 256-261, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31918378

RESUMO

PURPOSE: Minibeam radiation therapy (MBRT) is a novel therapeutic strategy, whose exploration was hindered due to its restriction to large synchrotrons. Our recent implementation of MBRT in a wide-spread small animal irradiator offers the possibility of performing systematic radiobiological studies. The aim of this research was to develop a set of dosimetric tools to reliably guide biological experiments in the irradiator. METHODS: A Monte Carlo (Geant4)-based dose calculation engine was developed. It was then benchmarked against a series of dosimetric measurements performed with gafchromic films. Two voxelized rat phantoms (ROBY, computer tomography) were used to evaluate the treatment plan of F98 tumor-bearing rats. The response of a group of 7 animals receiving a unilateral irradiation of 58 Gy was compared to a group of non-irradiated controls. RESULTS: The good agreement between calculations and the experimental data allowed the validation of the dose-calculation engine. The latter was first used to compare the dose distributions in computer tomography images of a rat's head and in a digital model of a rat's head (ROBY), obtaining a good general agreement. Finally, with respect to the in vivo experiment, the increase of mean survival time of the treated group with respect to the controls was modest but statistically significant. CONCLUSIONS: The developed dosimetric tools were used to reliably guide the first MBRT treatments of intracranial glioma-bearing rats outside synchrotrons. The significant tumor response obtained with respect to the non-irradiated controls, despite the heterogenous dose coverage of the target, might indicate the participation of non-targeted effects.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Neoplasias Experimentais/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Modelos Animais de Doenças , Elétrons , Glioma/tratamento farmacológico , Íons , Estimativa de Kaplan-Meier , Masculino , Método de Monte Carlo , Neoplasias Experimentais/diagnóstico por imagem , Distribuição Normal , Prótons , Dosagem Radioterapêutica , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Síncrotrons , Resultado do Tratamento
7.
Med Phys ; 47(3): 1379-1390, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31900944

RESUMO

PURPOSE: Minibeam radiation therapy (MBRT) is an innovative strategy based on a distinct dose delivery method that is administered using a series of narrow (submillimetric) parallel beams. To shed light on the biological effects of MBRT irradiation, we explored the micro- and nanodosimetric characteristics of three promising MBRT modalities (photon, electron, and proton) using Monte Carlo (MC) calculations. METHODS: Irradiation with proton (100 MeV), electron (300 MeV), and photon (effective energy of 69 keV) minibeams were simulated using Geant4 MC code and the Geant4-DNA extension, which allows the simulation of energy transfer points with nanometric accuracy. As the target of the simulations, cells containing spherical nuclei with or without a detailed description of the DNA (deoxyribonucleic acid) geometry were placed at different depths in peak and valley regions in a water phantom. The energy deposition and number of events in the cell nuclei were recorded in the microdosimetry study, and the number of DNA breaks and their complexity were determined in the nanodosimetric study, where a multi-scale simulation approach was used for the latter. For DNA damage assessment, an adapted DBSCAN clustering algorithm was used. To compare the photon MBRT (xMBRT), electron MBRT (eMBRT), and proton MBRT (pMBRT) approaches, we considered the treatment of a brain tumor located at a depth of 75 mm. RESULTS: Both mean energy deposition at micrometric scale and DNA damage in the "valley" cell nuclei were very low as compared with these parameters in the peak region at all depths for xMBRT and at depths of 0 to 30 mm and 0 to 50 mm for eMBRT and pMBRT, respectively. Only the charged minibeams were favorable for tumor control by producing similar effects in peak and valley cells after 70 mm. At the micrometer scale, the energy deposited per event pointed to a potential advantage of proton beams for tumor control, as more aggressive events could be expected at the end of their tracks. At the nanometer scale, all three MBRT modalities produced direct clustered DNA breaks, although the majority of damage (>93%) was composed of isolated single strand breaks. The pMBRT led to a significant increase in the proportion of clustered single strand breaks and double-strand breaks at the end of its range as compared to the entrance (7% at 75 mm vs 3% at 10 mm) in contrast to eMBRT and xMBRT. In the latter cases, the proportions of complex breaks remained constant, irrespective of the depth and region (peak or valley). CONCLUSIONS: Enhanced normal tissue sparing can be expected with these three MBRT techniques. Among the three modalities, pMBRT offers an additional gain for radioresistant tumors, as it resulted in a higher number of complex DNA damage clusters in the tumor region. These results can aid understanding of the biological mechanisms of MBRT.


Assuntos
Método de Monte Carlo , Radiometria/métodos , Radioterapia , Nanotecnologia
8.
Cancer Radiother ; 23(6-7): 677-681, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31494038

RESUMO

In radiation therapy, a renewed interest is emerging for the study of spatially fractionated irradiation. In this article, a few applications using spatial fractionation of the dose will be discussed with a focus on proton minibeam radiation therapy. Examples of calculated dose (1D profiles and 2D dose distributions) and biological evidence obtained so far will be presented for various spatially fractionated techniques GRID, micro- and minibeam radiation therapy. Recent results demonstrating that proton minibeam radiation therapy leads to an increase in normal tissues sparing will be discussed, which opens the door to a dose escalation in the tumour and a possibly efficient treatment of very radioresistant tumours.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Terapia com Prótons/métodos , Animais , Humanos , Lesões por Radiação/prevenção & controle , Tolerância a Radiação , Ratos
9.
Med Phys ; 45(6): 2620-2627, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29633284

RESUMO

PURPOSE: The alliance of charged particle therapy and the spatial fractionation of the dose, as in minibeam or Grid therapy, is an innovative strategy to improve the therapeutic index in the treatment of radioresistant tumors. The aim of this work was to assess the optimum irradiation configuration in heavy ion spatially fractionated radiotherapy (SFRT) in terms of ion species, beam width, center-to-center distances, and linear energy transfer (LET), information that could be used to guide the design of the future biological experiments. The nuclear fragmentation leading to peak and valley regions composed of different secondary particles, creates the need for a more complete dosimetric description that the classical one in SFRT. METHODS: Monte Carlo simulations (GATE 6.2) were performed to evaluate the dose distributions for different ions, beam widths, and spacings. We have also assessed the 3D-maps of dose-averaged LET and proposed a new parameter, the peak-to-valley-LET ratio, to offer a more thorough physical evaluation of the technique. RESULTS: Our results show that beam widths larger than 400 µm are needed in order to keep a ratio between the dose in the entrance and the dose in the target of the same order as in conventional irradiations. A large ctc distance (3500 µm) would favor tissue sparing since it provides higher PVDR, it leads to a reduced contribution of the heavier nuclear fragments and a LET value in the valleys a factor 2 lower than the LET in the ctc leading to homogeneous distributions in the target. CONCLUSIONS: Heavy ions MBRT provide advantageous dose distributions. Thanks to the reduced lateral scattering, the use of submillimetric beams still allows to keep a ratio between the dose in the entrance and the dose in the target of the same order as in conventional irradiations. Large ctc distances (3500 µm) should be preferred since they lead to valley doses composed of lighter nuclear fragments resulting in a much reduced dose-averaged LET values in normal tissue, favoring its preservation. Among the different ions species evaluated, Ne stands out as the one leading to the best balance between high PVDR and PVLR in normal tissues and high LET values (close to 100 keV/µm) and a favorable oxygen enhancement ratio in the target region.


Assuntos
Fracionamento da Dose de Radiação , Radioterapia com Íons Pesados/métodos , Simulação por Computador , Radioterapia com Íons Pesados/instrumentação , Humanos , Método de Monte Carlo , Imagens de Fantasmas
10.
Sci Rep ; 7(1): 17295, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29229965

RESUMO

Minibeam radiation therapy (MBRT) is an innovative synchrotron radiotherapy technique able to shift the normal tissue complication probability curves to significantly higher doses. However, its exploration was hindered due to the limited and expensive beamtime at synchrotrons. The aim of this work was to develop a cost-effective equipment to perform systematic radiobiological studies in view of MBRT. Tumor control for various tumor entities will be addressable as well as studies to unravel the distinct biological mechanisms involved in normal and tumor tissues responses when applying MBRT. With that aim, a series of modifications of a small animal irradiator were performed to make it suitable for MBRT experiments. In addition, the brains of two groups of rats were irradiated. Half of the animals received a standard irradiation, the other half, MBRT. The animals were followed-up for 6.5 months. Substantial brain damage was observed in the group receiving standard RT, in contrast to the MBRT group, where no significant lesions were observed. This work proves the feasibility of the transfer of MBRT outside synchrotron sources towards a small animal irradiator.


Assuntos
Neoplasias Encefálicas/patologia , Encéfalo/patologia , Análise Custo-Benefício , Imagens de Fantasmas , Síncrotrons/economia , Síncrotrons/instrumentação , Animais , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Ratos
11.
Phys Med Biol ; 61(11): 4036-47, 2016 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-27163881

RESUMO

The commissioning of an ion beam for hadrontherapy requires the evaluation of the biologically weighted effective dose that results from the microdosimetric properties of the therapy beam. The spectra of the energy imparted at cellular and sub-cellular scales are fundamental to the determination of the biological effect of the beam. These magnitudes are related to the microdosimetric distributions of the ion beam at different points along the beam path. This work is dedicated to the measurement of microdosimetric spectra at several depths in the central axis of a (12)C beam with an energy of 94.98 AMeV using a novel 3D ultrathin silicon diode detector. Data is compared with Monte Carlo calculations providing an excellent agreement (deviations are less than 2% for the most probable lineal energy value) up to the Bragg peak. The results show the feasibility to determine with high precision the lineal energy transfer spectrum of a hadrontherapy beam with these silicon devices.


Assuntos
Radioterapia com Íons Pesados/instrumentação , Radiometria/instrumentação , Silício , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Prótons
12.
Med Phys ; 42(12): 7108-13, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26632064

RESUMO

PURPOSE: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy (RT) approach that allies the inherent physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams. This dosimetry work aims at demonstrating the feasibility of the technical implementation of pMBRT. This has been performed at the Institut Curie - Proton Therapy Center in Orsay. METHODS: Proton minibeams (400 and 700 µm-width) were generated by means of a brass multislit collimator. Center-to-center distances between consecutive beams of 3200 and 3500 µm, respectively, were employed. The (passive scattered) beam energy was 100 MeV corresponding to a range of 7.7 cm water equivalent. Absolute dosimetry was performed with a thimble ionization chamber (IBA CC13) in a water tank. Relative dosimetry was carried out irradiating radiochromic films interspersed in a IBA RW3 slab phantom. Depth dose curves and lateral profiles at different depths were evaluated. Peak-to-valley dose ratios (PVDR), beam widths, and output factors were also assessed as a function of depth. RESULTS: A pattern of peaks and valleys was maintained in the transverse direction with PVDR values decreasing as a function of depth until 6.7 cm. From that depth, the transverse dose profiles became homogeneous due to multiple Coulomb scattering. Peak-to-valley dose ratio values extended from 8.2 ± 0.5 at the phantom surface to 1.08 ± 0.06 at the Bragg peak. This was the first time that dosimetry in such small proton field sizes was performed. Despite the challenge, a complete set of dosimetric data needed to guide the first biological experiments was achieved. CONCLUSIONS: pMBRT is a novel strategy in order to reduce the side effects of RT. This works provides the experimental proof of concept of this new RT method: clinical proton beams might allow depositing a (high) uniform dose in a brain tumor located in the center of the brain (7.5 cm depth, the worst scenario), while a spatial fractionation of the dose is retained in the normal tissues in the beam path, potentially leading to a gain in tissue sparing. This is the first complete experimental implementation of this promising technique. Biological experiments are needed in order to confirm the clinical potential of pMBRT.


Assuntos
Terapia com Prótons/métodos , Estudos de Viabilidade , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Água
13.
Med Phys ; 42(11): 6703-10, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26520760

RESUMO

PURPOSE: The outcome of radiotherapy can be further improved by combining irradiation with dose enhancers such as high-Z nanoparticles. Since 2004, spectacular results have been obtained when low-energy x-ray irradiations have been combined with nanoparticles. Recently, the same combination has been explored in hadron therapy. In vitro studies have shown a significant amplification of the biological damage in tumor cells charged with nanoparticles and irradiated with fast ions. This has been attributed to the increase in the ionizations and electron emissions induced by the incident ions or the electrons in the secondary tracks on the high-Z atoms, resulting in a local energy deposition enhancement. However, this subject is still a matter of controversy. Within this context, the main goal of the authors' work was to provide new insights into the dose enhancement effects of nanoparticles in proton therapy. METHODS: For this purpose, Monte Carlo calculations (gate/geant4 code) were performed. In particular, the geant4-DNA toolkit, which allows the modeling of early biological damages induced by ionizing radiation at the DNA scale, was used. The nanometric radial energy distributions around the nanoparticle were studied, and the processes (such as Auger deexcitation or dissociative electron attachment) participating in the dose deposition of proton therapy treatments in the presence of nanoparticles were evaluated. It has been reported that the architecture of Monte Carlo calculations plays a crucial role in the assessment of nanoparticle dose enhancement and that it may introduce a bias in the results or amplify the possible final dose enhancement. Thus, a dosimetric study of different cases was performed, considering Au and Gd nanoparticles, several nanoparticle sizes (from 4 to 50 nm), and several beam configurations (source-nanoparticle distances and source sizes). RESULTS: This Monte Carlo study shows the influence of the simulations' parameters on the local dose enhancement and how more realistic configurations lead to a negligible increase of local energy deposition. The obtained dose enhancement factor was up to 1.7 when the source was located at the nanoparticle surface. This dose enhancement was reduced when the source was located at further distances (i.e., in more realistic situations). Additionally, no significant increase in the dissociative electron attachment processes was observed. CONCLUSIONS: The authors' results indicate that physical effects play a minor role in the amplification of damage, as a very low dose enhancement or increase of dissociative electron attachment processes is observed when the authors get closer to more realistic simulations. Thus, other effects, such as biological or chemical processes, may be mainly responsible for the enhanced radiosensibilization observed in biological studies. However, more biological studies are needed to verify this hypothesis.


Assuntos
Nanopartículas Metálicas/uso terapêutico , Terapia com Prótons/métodos , Terapia Combinada/métodos , Simulação por Computador , Gadolínio , Ouro , Método de Monte Carlo , Tamanho da Partícula , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica , Água
14.
Med Phys ; 42(10): 5928-36, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26429267

RESUMO

PURPOSE: This work explores a new radiation therapy approach which might trigger a renewed use of neon and heavier ions to treat cancers. These ions were shown to be extremely efficient in radioresistant tumor killing. Unfortunately, the efficient region also extends into the normal tissue in front of the tumor. The strategy the authors propose is to profit from the well-established sparing effect of thin spatially fractionated beams, so that the impact on normal tissues might be minimized while a high tumor control is achieved. The main goal of this work is to provide a proof of concept of this new approach. With that aim, a dosimetric study was carried out as a first step to evaluate the interest of further explorations of this avenue. METHODS: The gate/geant4 v.6.1 Monte Carlo simulation platform was employed to simulate arrays of rectangular minibeams (700 µm × 2 cm) of four ions (Ne, Si, Ar, and Fe). The irradiations were performed with a 2 cm-long spread-out Bragg peak centered at 7 cm-depth. Dose distributions in a water phantom were scored considering two minibeams center-to-center distances: 1400 and 3500 µm. Peak and valley doses, peak-to-valley dose ratios (PVDRs), beam penumbras, and relative contribution of nuclear fragments and electromagnetic processes were assessed as figures of merit. In addition, the type and proportion of the secondary nuclear fragments were evaluated in both peak and valley regions. RESULTS: Extremely high PVDR values (>100) and low valley doses were obtained. The higher the atomic number (Z) of the primary ion is, the lower the valleys and the narrower the penumbras. Although the yield of secondary nuclear products increases with Z, the actual dose being deposited by the secondary nuclear fragments in the valleys starts to be the dominant contribution at deeper points, helping in the sparing of proximal normal tissues. Additionally, a wider center-to-center distance leads to a minimized contribution of heavier secondary fragments in valleys. CONCLUSIONS: The computed dose distributions suggest that a spatial fractionation of the dose combined to the use of submillimetric field sizes might allow profiting from the high efficiency of neon and heavier ions for the treatment of radioresistant tumors, while preserving normal tissues. The authors' results support the further exploration of this avenue. Next steps include the realization of biological experiment to confirm the shifting of normal tissue complication probability curves.


Assuntos
Fracionamento da Dose de Radiação , Radioterapia com Íons Pesados , Método de Monte Carlo , Neônio/uso terapêutico , Íons Pesados/efeitos adversos , Neônio/efeitos adversos , Tratamentos com Preservação do Órgão , Radiometria
15.
Med Phys ; 42(2): 685-93, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25652482

RESUMO

PURPOSE: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose-volume effects. METHODS: Monte Carlo simulations (penelope/peneasy and geant4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. RESULTS: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. CONCLUSIONS: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.


Assuntos
Radioterapia/métodos , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/radioterapia , Elétrons/uso terapêutico , Humanos , Método de Monte Carlo , Terapia com Prótons , Radiometria , Dosagem Radioterapêutica
16.
Med Phys ; 41(6): 061706, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24877801

RESUMO

PURPOSE: Minibeam radiation therapy (MBRT) exploits the well-established tissue-sparing effect provided by the combination of submillimetric field sizes and a spatial fractionation of the dose. The aim of this work is to evaluate the feasibility and potential therapeutic gain of MBRT, in comparison with conventional radiotherapy, for osteosarcoma treatments. METHODS: Monte Carlo simulations (PENELOPE/penEasy code) were used as a method to study the dose distributions resulting from MBRT irradiations of a rat femur and a realistic human femur phantoms. As a figure of merit, peak and valley doses and peak-to-valley dose ratios (PVDR) were assessed. Conversion of absorbed dose to normalized total dose (NTD) was performed in the human case. Several field sizes and irradiation geometries were evaluated. RESULTS: It is feasible to deliver a uniform dose distribution in the target while the healthy tissue benefits from a spatial fractionation of the dose. Very high PVDR values (⩾20) were achieved in the entrance beam path in the rat case. PVDR values ranged from 2 to 9 in the human phantom. NTD(2.0) of 87 Gy might be reached in the tumor in the human femur while the healthy tissues might receive valley NTD(2.0) lower than 20 Gy. The doses in the tumor and healthy tissues might be significantly higher and lower than the ones commonly delivered used in conventional radiotherapy. CONCLUSIONS: The obtained dose distributions indicate that a gain in normal tissue sparing might be expected. This would allow the use of higher (and potentially curative) doses in the tumor. Biological experiments are warranted.


Assuntos
Simulação por Computador , Fêmur , Modelos Biológicos , Método de Monte Carlo , Osteossarcoma/radioterapia , Radioterapia/métodos , Animais , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Fêmur/efeitos da radiação , Humanos , Imagens de Fantasmas , Radioterapia/instrumentação , Dosagem Radioterapêutica , Ratos
17.
Phys Med ; 30(1): 57-62, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23597423

RESUMO

Minibeam radiation therapy (MBRT) is an innovative radiotherapy approach based on the well-established tissue sparing effect of arrays of quasi-parallel micrometre-sized beams. In order to guide the preclinical trials in progress at the European Synchrotron Radiation Facility (ESRF), a Monte Carlo-based dose calculation engine has been developed and successfully benchmarked with experimental data in anthropomorphic phantoms. Additionally, a realistic example of treatment plan is presented. Despite the micron scale of the voxels used to tally dose distributions in MBRT, the combination of several efficiency optimisation methods allowed to achieve acceptable computation times for clinical settings (approximately 2 h). The calculation engine can be easily adapted with little or no programming effort to other synchrotron sources or for dose calculations in presence of contrast agents.


Assuntos
Método de Monte Carlo , Tratamentos com Preservação do Órgão/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
18.
Clin Transl Oncol ; 16(8): 696-701, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24271740

RESUMO

PURPOSE: To assess the DNA damage induced by MBRT and BB radiations on glioma cells. METHODS: The analysis of fluorescent intensity emitted per nucleus was plotted versus DNA content 2 and 17 h after irradiations. At around cell-doubling time (17 h) after exposures, the remaining DNA radiation damage could be correlated with cellular death. RESULTS: A higher γH2AX IF intensity per cell could be detected 2 and 17 h after MBRT when compared with BB. 17 h after MBRT, misrepaired damaged cells remained arrested in both G1 and G2 phases. CONCLUSIONS: A pronounced G2 phase arrest was detected at 17 h after MBRT and BB. However, only after MBRT, a dose-dependent increasing number of damaged cells appeared arrested also in the G1 phase, and a higher amount of cells more prone to undergo apoptosis were detected. The threshold dose required to enhance the effectiveness of both synchrotron radiation techniques was 12 Gy.


Assuntos
Quebras de DNA de Cadeia Dupla/efeitos da radiação , Glioma/genética , Radioterapia/métodos , Animais , Linhagem Celular Tumoral , Ratos , Síncrotrons
19.
Phys Med Biol ; 58(9): 2879-99, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23571094

RESUMO

Monte Carlo simulations play a crucial role for in-vivo treatment monitoring based on PET and prompt gamma imaging in proton and carbon-ion therapies. The accuracy of the nuclear fragmentation models implemented in these codes might affect the quality of the treatment verification. In this paper, we investigate the nuclear models implemented in GATE/Geant4 and FLUKA by comparing the angular and energy distributions of secondary particles exiting a homogeneous target of PMMA. Comparison results were restricted to fragmentation of (16)O and (12)C. Despite the very simple target and set-up, substantial discrepancies were observed between the two codes. For instance, the number of high energy (>1 MeV) prompt gammas exiting the target was about twice as large with GATE/Geant4 than with FLUKA both for proton and carbon ion beams. Such differences were not observed for the predicted annihilation photon production yields, for which ratios of 1.09 and 1.20 were obtained between GATE and FLUKA for the proton beam and the carbon ion beam, respectively. For neutrons and protons, discrepancies from 14% (exiting protons-carbon ion beam) to 57% (exiting neutrons-proton beam) have been identified in production yields as well as in the energy spectra for neutrons.


Assuntos
Radioterapia com Íons Pesados/métodos , Método de Monte Carlo , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Nêutrons , Dosagem Radioterapêutica , Fatores de Tempo
20.
Med Phys ; 40(3): 031712, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464307

RESUMO

PURPOSE: This Monte Carlo simulation work aims at studying a new radiotherapy approach called proton-minibeam radiation therapy (pMBRT). The main objective of this proof of concept was the evaluation of the possible gain in tissue sparing, thanks to the spatial fractionation of the dose, which could be used to deposit higher and potentially curative doses in clinical cases where tissue tolerances are a limit for conventional methods. METHODS: Monte Carlo simulations (GATE v.6) have been used as a method to calculate the ratio of the peak-to-valley doses (PVDR) for arrays of proton minibeams of 0.7 mm width and several center-to-center distances, at different depths in a water phantom. The beam penumbras were also evaluated as an important parameter for tissue sparing, for example, in the treatment of non-cancer diseases like epilepsy. Two proton energies were considered in this study: a clinically relevant energy (105 MeV) and a very high energy (1 GeV), to benefit from a reduced lateral scattering. For the latter case, an interlaced geometry was also evaluated. RESULTS: Higher or similar PVDR than the ones obtained in x-rays minibeam radiation therapy were achieved in several pMBRT configurations. In addition, for the two energies studied, the beam penumbras are smaller than in the case of Gamma Knife radiosurgery. CONCLUSIONS: The high PVDR obtained for some configurations and the small penumbras in comparison with existing radiosurgery techniques, suggest a potential gain in healthy tissue sparing in this new technique. Biological studies are warranted to assess the effects of pMBRT on both normal and tumoral tissues.


Assuntos
Método de Monte Carlo , Terapia com Prótons , Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia Assistida por Computador/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA