Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Prostate Cancer ; 2023: 6641707, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37885823

RESUMO

Background: Androgen deprivation therapy (ADT) for prostate cancer is implicated as a possible cause of cognitive impairment (CI). CI in dementia and Alzheimer's disease is associated with neuroinflammation. In this study, we investigated a potential role of neuroinflammation in ADT-related CI. Methods: Patients with prostate cancer on ADT for ≥3 months were categorized as having ADT-emergent CI or normal cognition (NC) based on self-report at interview. Neuroinflammation was evaluated using positron emission tomography (PET) with the translocator protein (TSPO) radioligand [11C]-PBR28. [11C]-PBR28 uptake in various brain regions was quantified as standardized uptake value (SUVR, normalized to cerebellum) and related to blood oxygen level-dependent functional magnetic resonance imaging (BOLD-fMRI) choice-reaction time task (CRT) activation maps. Results: Eleven patients underwent PET: four with reported CI (rCI), six with reported NC (rNC), and one status unrecorded. PET did not reveal any between-group differences in SUVR regionally or globally. There was no difference between groups on brain activation to the CRT. Regardless of the reported cognitive status, there was strong correlation between PET-TSPO signal and CRT activation in the hippocampus, amygdala, and medial cortex. Conclusions: We found no difference in neuroinflammation measured by PET-TSPO between patients with rCI and rNC. However, we speculate that the strong correlation between TSPO uptake and BOLD-fMRI activation in brain regions involved in memory and known to have high androgen-receptor expression mediating plasticity (hippocampus and amygdala) might reflect inflammatory effects of ADT with compensatory upregulated/increased synaptic functions. Further studies of this imaging readout are warranted to investigate ADT-related CI.

2.
J Nucl Med ; 62(5): 738-744, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-32948679

RESUMO

Parametric imaging has been shown to provide better quantitation physiologically than SUV imaging in PET. With the increased sensitivity from a recently developed total-body PET scanner, whole-body scans with higher temporal resolution become possible for dynamic analysis and parametric imaging. In this paper, we focus on deriving the parameter k1 using compartmental modeling and on developing a method to acquire whole-body 18F-FDG PET parametric images using only the first 90 s of the postinjection scan data with the total-body PET system. Methods: Dynamic projections were acquired with a time interval of 1 s for the first 30 s and a time interval of 2 s for the following minute. Image-derived input functions were acquired from the reconstructed dynamic sequences in the ascending aorta. A 1-tissue-compartment model with 4 parameters (k1, k2, blood fraction, and delay time) was used. A maximum-likelihood-based estimation method was developed with the 1-tissue-compartment model solution. The accuracy of the acquired parameters was compared with the ones estimated using a 2-tissue-compartment irreversible model with 1-h-long data. Results: All 4 parametric images were successfully calculated using data from 2 volunteers. By comparing the time-activity curves acquired from the volumes of interest, we showed that the parameters estimated using our method were able to predict the time-activity curves of the early dynamics of 18F-FDG in different organs. The delay-time effects for different organs were also clearly visible in the reconstructed delay-time image with delay variations of as large as 40 s. The estimated parameters using both 90-s data and 1-h data agreed well for k1 and blood fraction, whereas a large difference in k2 was found between the 90-s and 1-h data, suggesting k2 cannot be reliably estimated from the 90-s scan. Conclusion: We have shown that with total-body PET and the increased sensitivity, it is possible to estimate parametric images based on the very early dynamics after 18F-FDG injection. The estimated k1 might potentially be used clinically as an indicator for identifying abnormalities.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Funções Verossimilhança , Distribuição Tecidual
3.
PET Clin ; 16(1): 89-97, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33160926

RESUMO

Total-body PET enables high-sensitivity imaging with dramatically improved signal-to-noise ratio. These enhanced performance characteristics allow for decreased PET scanning times acquiring data "total-body wide" and can be leveraged to decrease the amount of radiotracer required, thereby permitting more frequent imaging or longer imaging periods during radiotracer decay. Novel approaches to PET imaging of infectious diseases are emerging, including those that directly visualize pathogens in vivo and characterize concomitant immune responses and inflammation. Efforts to develop these imaging approaches are hampered by challenges of traditional imaging platforms, which may be overcome by novel total-body PET strategies.


Assuntos
Doenças Transmissíveis/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Humanos , Razão Sinal-Ruído , Tempo
4.
J Nucl Med ; 60(3): 299-303, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30733314

RESUMO

Within the EXPLORER Consortium, the construction of the world's first total-body PET/CT scanner has recently been completed. The 194-cm axial field of view of the EXPLORER PET/CT scanner is sufficient to cover, for the first time, the entire human adult body in a single acquisition in more than 99% of the population and allows total-body pharmacokinetic studies with frame durations as short as 1 s. The large increase in sensitivity arising from total-body coverage as well as increased solid angle for detection at any point within the body allows whole-body 18F-FDG PET studies to be acquired with unprecedented count density, improving the signal-to-noise ratio of the resulting images. Alternatively, the sensitivity gain can be used to acquire diagnostic PET images with very small amounts of activity in the field of view (25 MBq, 0.7 mCi or less), with very short acquisition times (∼1 min or less) or at later time points after the tracer's administration. We report here on the first human imaging studies on the EXPLORER scanner using a range of different protocols that provide initial evidence in support of these claims. These case studies provide the foundation for future carefully controlled trials to quantitatively evaluate the improvements possible through total-body PET imaging.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Doses de Radiação , Fatores de Tempo
5.
Radiat Oncol ; 13(1): 204, 2018 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-30340643

RESUMO

BACKGROUND: Stereotactic ablative radiotherapy (SABR) offers an alternative treatment for pancreatic cancer, with the potential for improved tumour control and reduced toxicity compared with conventional therapies. However, optimal dose planning and delivery strategies are unelucidated and gastro-intestinal (GI) toxicity remains a key concern. METHODS: Patients with inoperable non-metastatic pancreatic cancer who received CyberKnife® SABR (18-36 Gy) in three fractions as primary, adjuvant, consolidation or re-treatment options were studied. Patient individualised planning and delivery variables were collected and their impact on patient outcome examined. Linear-quadratic (LQ) radiobiology modelling methods were applied to assess SABR parameters against a conventional fractionated radiotherapy schedule. RESULTS: In total 42 patients were included, 37 (88%) of whom had stage T4 disease. SABR was used > 6 months post-primary therapy to re-treat residual disease in 11 (26.2%) patients and relapsed disease in nine (21.4%) patients. SABR was an adjuvant to other primary therapy for 14 (33.3%) patients and was the sole primary therapy for eight (19.0%) patients. The mean (95% CI) planning target volume (PTV), prescription isodose, percentage cover, minimum dose to PTV and biological effective dose (BED) were 76.3(63.8-88.7) cc, 67.3(65.2-69.5)%, 96.6(95.5-97.7)%, 22.3(21.0-23.6) Gy and 50.3(47.7-53.0) Gy, respectively. Only 3/37 (8.1%) patients experienced Grade 3 acute toxicities. Two (4.8%) patients converted to resectable status and median freedom-from-local-progression (FFLP) and overall survival (OS) were 9.8 and 8.4 months, respectively. No late toxicity was experienced in 27/32 (84.4%) patients; however, four (12.5%) patients - of whom two had particularly large PTV, two had sub-optimal number of fiducials and three breached organ-at-risk (OAR) constraints-showed Grade 4 duodenal toxicities. Longer delivery time, extended treatment course and reduced percentage coverage additionally associated with late toxicity, likely reflecting parameters typically applied to riskier patients. Larger PTV size and longer treatment course associated with OS. Comparator regimen LQ modelling analysis indicated 50% of patients received minimum PTV doses less potent than a conventional radiotherapy regimen, indicating scope for dose escalation. CONCLUSION: The results demonstrate the value of SABR for a range of indications in pancreatic cancer. Dose escalation to increase BED may improve FFLP and OS in inoperable, non-metastatic disease: however concomitant enhanced stringency for duodenal protection is critical, particularly for patients where SABR is more challenging.


Assuntos
Fracionamento da Dose de Radiação , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/cirurgia , Complicações Pós-Operatórias , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Prognóstico , Retratamento , Taxa de Sobrevida
6.
Cureus ; 10(3): e2380, 2018 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-29805949

RESUMO

The study aim was to evaluate patient individualized Cyberknife® treatment for heterogeneous skull-base tumors. Patients treated between 2009 and 2013 at The Harley Street Clinic were studied. In total, 66 patients received 15-30 Gy in 1-5 fractions to a median planning target volume (PTV) of 6.4 cc, including patients with secondary, multiple, residual and recurrent tumors, and those with tumors of uncertain pathological type. Outcome analysis was pragmatically restricted to 35 patients who had single, primary tumors treated with curative intent, and sufficient diagnostic and outcome information. Sixteen vestibular schwannoma patients with median PTV 3.8 cc (range 0.81-19.6) received 18-25 Gy in 3-5 fractions: 81% showed no acute toxicity, 50% reported no late toxicity, 71% of symptoms were stable/improved and local control was 100% at 11.4 months median follow-up. Twelve meningioma patients with median PTV of 5.5 cc (range 0.68-22.3) received 17-30 Gy in 1-5 fractions: 83% experienced no acute toxicity, 33% reported no late toxicity, 88% of symptoms were stable/improved and local control was 100% at 22.1 months median follow-up. Seven patients with other tumor types with median PTV of 24.3 cc (range 7.6-100.5) received 15-28.5 Gy in 1-5 fractions: 57% experienced no acute toxicity, 57% reported no late toxicities, 66% of symptoms were stable and local control was 43% at 14.9 months median follow-up. When tumor types were considered together, smaller tumors (PTV < 6.4 cc) showed reduced acute toxicity (p = 0.01). Overall, smaller benign tumors showed low acute toxicity, excellent local control, and good symptom management: a focus on enhanced neurological preservation may refine outcomes. For other tumor types outcome was encouraging: a focus on optimal dose and fractionation scheduling may reduce toxicity and improve local control. Individual patient experiences are detailed where valuable lessons were gained for optimizing local control and minimizing toxicity.

7.
Cureus ; 10(10): e3523, 2018 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-30648058

RESUMO

Introduction  The underlying assumptions of the CyberKnife® (Accuray, Sunnyvale, CA, US) fiducial tracking system are: i) fiducial positions are accurately detected; ii) inter-fiducial geometry remains consistent (rigid); iii) inter-fiducial geometric array changes are detected and either accommodated with corrections or treatment is interrupted. However: i) soft-tissue targets are deformable & fiducial migration is possible; ii) the accuracy of the tracking system has not previously been examined with fiducial displacement; iii) treatment interruptions may occur due to inter-fiducial geometric changes, but there is little information available to assist subsequent troubleshooting. The purpose of this study was to emulate a clinical target defined with a two, three, or four-fiducial array where one fiducial is displaced to mimic a target deformation or fiducial migration scenario. The objectives: evaluate the fiducial positioning accuracy, array interpretation, & corresponding corrections of the CyberKnife system, with the aim of assisting troubleshooting following fiducial displacement. Methods A novel solid-water phantom was constructed with three fixed fiducials (F1,F2,F3) & one moveable fiducial (F4), arranged as if placed to track an imaginary clinical target. Using either two fiducials (F1,F4), different combinations of three fiducials (F1,F2,F4; F1,F3,F4; F2,F3,F4) or four fiducials (F1,F2,F3,F4), repeat experiments were conducted where F4 was displaced inferiorly at 2-mm intervals from 0-16 mm. Data were acquired at each position of F4, including rigid body errors (RBE), fiducial x, y, & z coordinate displacements, six degrees of freedom (DOF) corrections, & robot center-of-mass (COM) translation corrections. Results Maximum positioning difference (mean±SD) between the reference and live x, y, & z coordinates for the three fixed fiducials was 0.08±0.30 mm, confirming good accuracy for fixed fiducial registration. For two fiducials (F1,F4), F4 registration was accurate to 14-mm displacement and the F4 x-axis coordinate change was 2.0±0.12 mm with each 2 mm inferior displacement validating the phantom for tracking evaluation. RBE was >5 mm (system threshold) at 6-14 mm F4 displacement: however, F1 was misidentified as the RBE main contributor. Further, F1/F4 false-lock occurred at 16 mm F4 displacement with corresponding RBE <3 mm & COM corrections >13 mm. For combinations of three fiducials, F4 registration was accurate to 10-mm displacement. RBE was >5 mm at 6-16 mm F4 displacement: however, F4 false-lock occurred at 12-16 mm with RBE 5-6 mm. For four fiducials, F4 registration was accurate to 4 mm displacement: however, F4 false-lock occurred at 6-16 mm displacement with concerning RBE <2 & <5 at 6 & 8-mm F4 displacement, respectively. False-locks were easily identified in the phantom but frequently uncorrectable. Conclusions Results indicate fiducial positioning accuracy and system output following fiducial displacement depends on the number of fiducials correlated, displacement distance, and clinical thresholds applied. Displacements ≤4 mm were accurately located, but some displacements 6-16 mm were misrepresented, either by erroneous main contributor (two-fiducial array only) or by false-locks and misleading RBE, which underestimated displacement. Operator vigilance and implementation of our practical guidelines based on the study findings may help reduce targeting error and assist troubleshooting in clinical situations.

8.
Artigo em Inglês | MEDLINE | ID: mdl-28652810

RESUMO

BACKGROUND: We developed, applied, and prospectively evaluated a novel deep-inspiration breath-hold (DIBH) screening and delivery technique to optimize cardiac sparing in left-breast radiotherapy (RT) at our clinic. The impact of set-up and dose variables upon organs at risk (OAR) dose in DIBH RT was investigated. METHODS AND MATERIALS: All patients with left-breast cancer referred between 2011 and 2014 - of all disease stages, set-up variations, and dose prescriptions - were included. Radiographers used simple screening criteria at CT simulation, to systematically assess patients for obvious DIBH benefit and capability. Selected patients received forward-planned intensity-modulated RT (IMRT) based on a DIBH CT scan. A 3D-surface monitoring system with visual feedback assured reproducible DIBH positioning during gated radiation delivery. Patient, target set-up, and OAR dose information were collected at treatment. RESULTS: Of 272 patients who were screened, 4 withdrew, 56 showed no obvious advantage, and 56 showed benefit but had suitability issues; 156 patients were selected and successfully completed DIBH treatment. The technique was compatible with complex set-up and optimal target coverage was maintained. Comparison of free-breathing (FB) and DIBH treatment plans in the first five patients enrolled confirmed DIBH reduced heart radiation by ~80% (p = 0.032). Low OAR doses were achieved overall: the mean (95% confidence interval [CI]) heart dose was 1.17 (1.12-1.22) Gy, and the mean ipsilateral lung dose was 5.26 (5.01-5.52) Gy. Patients who underwent a standard radiation schedule (40 Gy/15#) after breast-conserving surgery had the lowest OAR doses: post-mastectomy treatment, simultaneous supraclavicular (SCV) node coverage, and alternative dose schedule (50 Gy/25#) were interrelated variables associated with increased OAR risk and compromised ipsilateral lung dose constraints. CONCLUSION: The DIBH technique was successfully implemented and resulted in optimally low heart radiation. All patients who demonstrate sufficient DIBH technique at planning CT are now offered DIBH RT at our clinic. Patients with more advanced disease, particularly those with additional pulmonary risk factors, warrant additional focus to improve lung sparing.

9.
Transl Oncol ; 7(1): 55-64, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24772208

RESUMO

BACKGROUND: Preclinical data have indicated the anti-epidermal growth factor receptor (EGFR) agent cetuximab (Erbitux) as a radiosensitizer in pancreatic cancer, but this has not been specifically addressed in a clinical study. We report the results of an original study initiated in 2007, where cetuximab was tested with radiotherapy (RT) alone in locally advanced pancreatic cancer in a phase II trial (PACER). METHODS: Patients (n = 21) received cetuximab loading dose (400 mg/m(2)) and weekly dose (250 mg/m(2)) during RT (50.4 Gy in 28 fractions). Toxicity and disease response end point data were prospectively assessed. A feasibility study of on-trial patient blood and skin sampling was incorporated. RESULTS: Treatment was well tolerated, and toxicity was low; most patients (71%) experienced acute toxicities of grade 2 or less. Six months posttreatment, stable local disease was achieved in 90% of evaluable patients, but only 33% were free from metastatic progression. Median overall survival was 7.5 months, and actuarial survival was 33% at 1 year and 11% at 3 years, reflecting swift metastatic progression in some patients but good long-term control of localized disease in others. High-grade acneiform rash (P = .0027), posttreatment stable disease (P = .0059), and pretreatment cancer antigen 19.9 (CA19.9) level (P = .0042) associated with extended survival. Patient skin and blood samples yielded sufficient RNA and good quality protein, respectively. CONCLUSIONS: The results indicate that cetuximab inhibits EGFR-mediated radioresistance to achieve excellent local control with minimal toxicity but does not sufficiently control metastatic progression in all patients. Translational studies of patient tissue samples may yield molecular information that may enable individual treatment response prediction.

11.
Health Aff (Millwood) ; 31(6): 1244-50, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22665836

RESUMO

Keeping patients and caregivers at the center of quality improvement is critical. Kaiser Permanente's Care Management Institute adapted video ethnography to achieve this aim, using video to capture interviews with-and observations of-patients and caregivers, identify patient-centered improvement opportunities, and communicate them effectively to clinical and administrative leaders and front-line staff. This method is particularly effective for helping understand the needs of frail elders, patients nearing the end of life, those with multiple chronic conditions, and other vulnerable people who are not well represented in focus groups and patient advisory councils. As part of an initiative to improve care transitions for elders with heart failure, video ethnography contributed to greatly reduced thirty-day hospital readmission rates, helping reduce readmissions at one medical center from 13.6 percent to 9 percent in six months. It also helped improve the reliability of the readmissions reduction program. When embedded within an established quality improvement framework, video ethnography can be an effective tool for innovating new solutions, improving existing processes, and spreading knowledge about how best to meet patient needs.


Assuntos
Antropologia Cultural , Programas de Assistência Gerenciada , Garantia da Qualidade dos Cuidados de Saúde/métodos , Gravação de Videoteipe , Enfermagem Geriátrica/normas , Humanos , Entrevistas como Assunto , Readmissão do Paciente/tendências
12.
Clin Cancer Res ; 18(5): 1415-25, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22235096

RESUMO

PURPOSE: Preclinical studies show that OXi4503 (combretastatin A1 diphosphate, CA1P) is more potent than other clinically evaluated vascular-disrupting agents. EXPERIMENTAL DESIGN: Escalating doses of OXi4503 were given intravenously over 10 minutes on days 1, 8, and 15 every 28 days to patients with advanced solid tumors. RESULTS: Doses were escalated in single-patient cohorts from 0.06 to 1.92 mg/m(2), then expanded cohorts to 15.4 mg/m(2) in 43 patients. Common adverse drug reactions were hypertension, tumor pain, anemia, lymphopenia, and easily controllable nausea/vomiting and fatigue. Five patients experienced different drug-related dose-limiting toxicities, atrial fibrillation, increased troponin, blurred vision, diplopia, and tumor lysis. Prophylactic amlodipine failed to prevent adverse events. Pharmacokinetics showed dose-dependent linear increases in peak plasma concentrations and area under the curve value of OXi4503. One partial response was seen in a heavily pretreated patient with ovarian cancer. Dynamic contrast-enhanced MRI confirmed a dose effect and showed significant antivascular effects in 10 of 13 patients treated at doses of 11 mg/m(2) or higher. CONCLUSIONS: The maximum tolerated dose was 8.5 mg/m(2) but escalation to 14 mg/m(2) was possible with only temporary reversible cerebrovascular toxicity by excluding hypertensive patients. As a tumor response was seen at 14 mg/m(2) and maximum tumor perfusion reductions were seen at doses of 11 mg/m(2) or higher, the recommended phase II dose is from 11 to 14 mg/m(2).


Assuntos
Inibidores da Angiogênese/uso terapêutico , Antineoplásicos/uso terapêutico , Difosfatos/uso terapêutico , Neoplasias/tratamento farmacológico , Estilbenos/uso terapêutico , Adulto , Idoso , Inibidores da Angiogênese/farmacocinética , Inibidores da Angiogênese/farmacologia , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Difosfatos/farmacocinética , Difosfatos/farmacologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico , Estilbenos/farmacocinética , Estilbenos/farmacologia , Resultado do Tratamento , Adulto Jovem
13.
Theranostics ; 1: 290-301, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21772926

RESUMO

Antisense oligonucleotides (ASOs) have potential as anti-cancer agents by specifically modulating genes involved in tumorigenesis. However, little is known about ASO biodistribution and tissue pharmacokinetics (PKs) in humans, including whether sufficient delivery to target tumor tissue may be achieved. In this preliminary study in human subjects, we used combined positron emission and computed tomography (PET-CT) imaging and subsequent modeling analysis of acquired dynamic data, to examine the in vivo biodistribution and PK properties of LY2181308 - a second generation ASO which targets the apoptosis inhibitor protein survivin. Following radiolabeling of LY2181308 with methylated carbon-11 ([(11)C]methylated-LY2181308), micro-doses (<1mg) were administered to three patients with solid tumors enrolled in a phase I trial. Moderate uptake of [(11)C]methylated-LY2181308 was observed in tumors (mean=32.5ng*h /mL, per mg administered intravenously). Highest uptake was seen in kidney and liver and lowest uptake was seen in lung and muscle. One patient underwent repeat analysis on day 15 of multiple dose therapy, during administration of LY2181308 (750mg), when altered tissue PKs and a favorable change in biodistribution was seen. [(11)C]methylated-LY2181308 exposure increased in tumor, lung and muscle, whereas renal and hepatic exposure decreased. This suggests that biological barriers to ASO tumor uptake seen at micro-doses were overcome by therapeutic dosing. In addition, (18)F-labeled fluorodeoxyglucose (FDG) scans carried out in the same patient before and after treatment showed up to 40% decreased tumor metabolism. For the development of anti-cancer ASOs, the results provide evidence of LY2181308 tumor tissue delivery and add valuable in vivo pharmacological information. For the development of novel therapeutic agents in general, the study exemplifies the merits of applying PET imaging methodology early in clinical investigations.

14.
Cancer Res ; 71(1): 143-53, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21084271

RESUMO

Non-invasive imaging of angiogenesis could ease the optimization of antiangiogenesis treatments for cancer. In this study, we evaluated the role of VEGF-PET as a biomarker of dynamic angiogenic changes in tumors following treatment with the kinase inhibitor sunitinib. The effects of sunitinib treatment and withdrawal on the tumor was investigated using the new VEGF-PET tracer (89)Zr-ranibizumab as well as (18)F-FDG PET, and (15)O-water PET in mouse xenograft models of human cancer. The obtained imaging results were compared with tumor growth, VEGF plasma levels and immunohistologic analyzes. In contrast to (18)F-FDG and (15)O-water PET, VEGF-PET demonstrated dynamic changes during sunitinib treatment within the tumor with a strong decline in signal in the tumor center and only minimal reduction in tumor rim, with a pronounced rebound after sunitinib discontinuation. VEGF-PET results corresponded with tumor growth and immunohistochemical vascular- and tumor- markers. Our findings highlight the strengths of VEGF-PET imaging to allow serial analysis of angiogenic changes in different areas within a tumor.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Antineoplásicos/uso terapêutico , Biomarcadores Tumorais/sangue , Indóis/uso terapêutico , Tomografia por Emissão de Pósitrons , Pirróis/uso terapêutico , Fator A de Crescimento do Endotélio Vascular/sangue , Animais , Fluordesoxiglucose F18 , Humanos , Masculino , Camundongos , Camundongos Nus , Sunitinibe , Transplante Heterólogo
15.
World J Gastrointest Oncol ; 2(4): 197-204, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21160598

RESUMO

AIM: To assess the relationship between preoperative computed tomography (CT) and postoperative pathological measurements of esophageal tumor length and the prognostic significance of CT tumor length data. METHODS: A retrospective study was carried out in 56 patients who underwent curative esophagogastrectomy. Tumor lengths were measured on the immediate preoperative CT and on the post-operative resection specimens. Inter- and intra-observer variations in CT measurements were assessed. Survival data were collected. RESULTS: There was a weak correlation between CT and pathological tumor length (r = 0.30, P = 0.025). CT lengths were longer than pathological lengths in 68% (38/56) of patients with a mean difference of 1.67 cm (95% CI: 1.18-2.97). The mean difference in measurements by two radiologists was 0.39 cm (95% CI: -0.59-1.44). The mean difference between repeat CT measured tumor length (intra-observer variation) were 0.04 cm (95% CI: -0.59-0.66) and 0.47 cm (95% CI: -0.53-1.47). When stratified, patients not receiving neoadjuvant chemotherapy showed a strong correlation between CT and pathological tumor length (r = 0.69, P = 0.0014, n = 37) than patients that did (r = 0.13, P = 0.43, n = 19). Median survival with CT tumor length > 5.6 cm was poorer than with smaller tumors, but the difference was not statistically significant. CONCLUSION: Esophageal tumor length assessed using CT does not reflect pathological tumor extent and should not be the only modality used for management decisions, particularly for planning radiotherapy.

16.
J Nucl Med ; 50(9): 1409-17, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19690021

RESUMO

UNLABELLED: The magnitude of the injected activity (A(0)) has a direct impact on the statistical quality of PET images. This study aimed to develop a generalized method for maximizing the statistical quality of dynamic PET images by optimizing A(0). METHODS: Patient-specific noise-equivalent counts (PS-NECs) were used as a metric of the statistical quality of each time frame of a dynamic PET image. Previous methodology developed to extrapolate the NEC as a function of A(0) was extended to dynamic PET, enabling the NEC to be extrapolated as a function of both A(0) and the time after injection. This method allowed A(0) to be optimized after a single scan (at a single A(0)), by maximizing the NEC within the time interval for which the parameter estimation is most sensitive. The extrapolation method was validated by a series of (15)O-H(2)O scans of the body acquired in 3-dimensional mode. Each patient (n = 6) underwent between 3 and 6 scans at 1 bed position. The injected activities were varied over a wide range (140-840 MBq). Noise-equivalent counting rate (NECR) versus A(0) curves and the optimal injected activities were calculated from each injection. RESULTS: PS-NECR versus A(0) curves as extrapolated from different injected activities were consistent (coefficient of variation, typically <5%). The optimal injected activities for an individual, as derived from these curves, were also consistent (maximum coefficient of variation, 4.3%). For abdominal (n = 4) and chest (n = 1) scans, we found optimal injected activities of (15)O-H(2)O in the range of 220-350 MBq for estimating blood perfusion (F) and 660-1,070 MBq for estimating the volume of distribution (V(T)). Higher optimal injected activities were found in the case of a pelvic scan (n = 1; 570 MBq for F and 1,530 MBq for V(T)). CONCLUSION: PS-NECs are a valid and generic method for optimizing the injected activity in PET, allowing scanning protocols to be improved after the collection of an initial, single dynamic dataset. This generic method can be used to estimate the optimal injected activity, which is specific to the patient, tracer, PET scanner, and body region being scanned.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Radioisótopos de Oxigênio/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Humanos , Injeções Intravenosas , Taxa de Depuração Metabólica , Modelos Biológicos , Modelos Estatísticos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água/metabolismo
17.
Int J Radiat Oncol Biol Phys ; 75(3): 664-71, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19473781

RESUMO

PURPOSE: Organ motion is recognized as the principal source of inaccuracy in bladder radiotherapy (RT), but there is currently little information on intrafraction bladder motion. METHODS AND MATERIALS: We used cine-magnetic resonance imaging (cine-MRI) to study bladder motion relevant to intrafraction RT delivery. On two occasions, a 28 minute cine-MRI sequence was acquired from 10 bladder cancer patients and 5 control participants immediately after bladder emptying, after abstinence from drinking for the preceding hour. From the resulting cine sequences, bladder motion was subjectively assessed. To quantify bladder motion, the bladder was contoured in imaging volume sets at 0, 14, and 28 min to measure changes to bladder volumes, wall displacements, and center of gravity (COG) over time. RESULTS: The dominant source of bladder motion during imaging was bladder filling (up to 101% volume increase); rectal and small bowel movements were transient, with minimal impact. Bladder volume changes were similar for all participants. However for bladder cancer patients, wall displacements were larger (up to 58 mm), less symmetrical, and more variable compared with nondiseased control bladders. CONCLUSIONS: Significant and individualized intrafraction bladder wall displacements may occur during bladder RT delivery. This important source of inaccuracy should be incorporated into treatment planning and verification.


Assuntos
Imagem Cinética por Ressonância Magnética , Movimento , Neoplasias da Bexiga Urinária/radioterapia , Bexiga Urinária/anatomia & histologia , Idoso , Estudos de Casos e Controles , Fracionamento da Dose de Radiação , Feminino , Humanos , Intestino Delgado/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Reto/anatomia & histologia , Reprodutibilidade dos Testes , Carga Tumoral , Neoplasias da Bexiga Urinária/patologia , Urina
18.
Cancer Res ; 69(1): 120-7, 2009 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19117994

RESUMO

Difficulties in direct measurement of drug concentrations in human tissues have hampered the understanding of drug accumulation in tumors and normal tissues. We propose a new system analysis modeling approach to characterize drug distribution in tissues based on human positron emission tomography (PET) data. The PET system analysis method was applied to temozolomide, an important alkylating agent used in the treatment of brain tumors, as part of standard temozolomide treatment regimens in patients. The system analysis technique, embodied in the convolution integral, generated an impulse response function that, when convolved with temozolomide plasma concentration input functions, yielded predicted normal brain and brain tumor temozolomide concentration profiles for different temozolomide dosing regimens (75-200 mg/m(2)/d). Predicted peak concentrations of temozolomide ranged from 2.9 to 6.7 microg/mL in human glioma tumors and from 1.8 to 3.7 microg/mL in normal brain, with the total drug exposure, as indicated by the tissue/plasma area under the curve ratio, being about 1.3 in tumor compared with 0.9 in normal brain. The higher temozolomide exposures in brain tumor relative to normal brain were attributed to breakdown of the blood-brain barrier and possibly secondary to increased intratumoral angiogenesis. Overall, the method is considered a robust tool to analyze and predict tissue drug concentrations to help select the most rational dosing schedules.


Assuntos
Antineoplásicos Alquilantes/farmacocinética , Neoplasias Encefálicas/metabolismo , Dacarbazina/análogos & derivados , Glioma/metabolismo , Modelos Biológicos , Administração Oral , Antineoplásicos Alquilantes/administração & dosagem , Antineoplásicos Alquilantes/sangue , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Neoplasias Encefálicas/sangue , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/tratamento farmacológico , Radioisótopos de Carbono , Dacarbazina/administração & dosagem , Dacarbazina/sangue , Dacarbazina/farmacocinética , Glioma/sangue , Glioma/diagnóstico por imagem , Glioma/tratamento farmacológico , Humanos , Marcação por Isótopo , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Temozolomida , Distribuição Tecidual
19.
Clin Cancer Res ; 12(10): 3115-23, 2006 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-16707610

RESUMO

PURPOSE: To examine whether carbogen and nicotinamide increases 5-fluorouracil (5-FU) delivery to colorectal cancer metastases. EXPERIMENTAL DESIGN: Six patients were scanned using positron emission tomography. Two scans were done to coincide with the start of separate chemotherapy cycles. At the second positron emission tomography session, 60 mg/kg nicotinamide was given orally 2 to 3 hours before 10-minute carbogen inhalation. In the middle of carbogen treatment, [15O]H2O (to measure regional tissue perfusion) and then [18F]5-FU (to measure 5-FU tissue pharmacokinetics) were administered. RESULTS: Regions of interest were drawn in 12 liver metastases, 6 spleens, 6 livers, and 12 kidneys. Nicotinamide and carbogen administration increased mean blood pO2 from 93 mm Hg (95% confidence interval, 79-198) to 278 mm Hg (95% confidence interval, 241-316; P = 0.031). Regional perfusion (mL(blood)/min/mL(tissue)) increased in metastases (mean change = 52%, range -32% to +261%, P = 0.024), but decreased in kidney (mean change = -42%, range -82% to -11%, P = 0.0005) and liver (mean change = -34%, range -43% to -26%, P = 0.031). 5-FU uptake at 3.75 minutes (m(2)/mL) increased in tumor (mean change = 40%, range -39% to +196%, P = 0.06) and decreased in kidney (mean change = -25%, range -71% to 12%, P = 0.043). 5-FU delivery measured as K1 increased in tumor (mean change = 74%, range -23% to +293%, P = 0.0039). No differences were seen in [18F]5-FU tumor exposure (net area under curve) and retention. CONCLUSION: Nicotinamide and carbogen administration can increase 5-FU delivery to colorectal cancer liver metastases. Despite an increase in perfusion and 5-FU delivery, the effects were not directly related and did not increase 5-FU retention or tissue exposure.


Assuntos
Antimetabólitos Antineoplásicos/farmacocinética , Dióxido de Carbono/farmacologia , Neoplasias Colorretais/tratamento farmacológico , Fluoruracila/farmacocinética , Neoplasias Hepáticas/tratamento farmacológico , Niacinamida/farmacologia , Oxigênio/farmacologia , Radiossensibilizantes/farmacologia , Complexo Vitamínico B/farmacologia , Administração por Inalação , Administração Oral , Idoso , Neoplasias Colorretais/patologia , Interações Medicamentosas , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Distribuição Tecidual
20.
Crit Rev Oncol Hematol ; 58(2): 95-113, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16387510

RESUMO

The primary physiological function of the vasculature is to support perfusion, the nutritive flow of blood through the tissues. Vascular physiology can be studied non-invasively in human subjects using imaging methods such as positron emission tomography (PET), magnetic resonance imaging (MRI), X-ray computed tomography (CT), and Doppler ultrasound (DU). We describe the physiological rationale for imaging vascular physiology with these methods. We review the published data on repeatability. We review the literature on 'before-and-after' studies using these methods to monitor response to treatment in human subjects, in five broad clinical settings: (1) antiangiogenic agents, (2) vascular disruptive agents, (3) conventional cytotoxic drugs, (4) radiation treatment, and (5) agents affecting drug delivery. We argue that imaging of vascular physiology offers an attractive 'functional endpoint' for clinical trials of anticancer treatment. More conventional measures of tumour response, such as size criteria and the uptake of fluorodeoxyglucose, may be insensitive to therapeutically important changes in vascular function.


Assuntos
Diagnóstico por Imagem , Monitorização Fisiológica/métodos , Neoplasias/irrigação sanguínea , Neovascularização Patológica/diagnóstico , Inibidores da Angiogênese/uso terapêutico , Antineoplásicos/uso terapêutico , Velocidade do Fluxo Sanguíneo , Ensaios Clínicos como Assunto , Monitoramento de Medicamentos , Humanos , Imageamento por Ressonância Magnética , Neoplasias/patologia , Neoplasias/terapia , Neovascularização Patológica/terapia , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA