Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Cardiovasc Intervent Radiol ; 46(11): 1621-1631, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37759090

RESUMO

PURPOSE: Evaluation of dual-layer spectral computed tomography (CT) for contrast enhancement during image-guided biopsy of liver lesions using virtual monoenergetic images (VMI) and virtual non-contrast (VNC) images. METHODS: Spectral CT data of 20 patients receiving CT-guided needle biopsy of focal liver lesions were used to generate VMI at energy levels from 40 to 200 keV and VNC images. Images were analyzed objectively regarding contrast-to-noise ratio between lesion center (CNRcent) or periphery (CNRperi) and normal liver parenchyma. Lesion visibility and image quality were evaluated on a 4-point Likert scale by two radiologists. RESULTS: Using VMI/VNC images, readers reported an increased visibility of the lesion compared to the conventional CT images in 18/20 cases. In 75% of cases, the highest visibility was derived by VMI-40. Showing all reconstructions simultaneously, VMI-40 offered the highest visibility in 75% of cases, followed by VNC in 12.5% of cases. Either CNRcent (17/20) or/and CNRperi (17/20) was higher (CNR increase > 50%) in 19/20 cases for VMI-40 or VNC images compared to conventional CT images. VMI-40 showed the highest CNRcent in 14 cases and the highest CNRperi in 12 cases. High image quality was present for all reconstructions with a minimum median of 3.5 for VMI-40 and VMI-50. CONCLUSIONS: When implemented in the CT scanner software, automated contrast enhancement of liver lesions during image-guided biopsy may facilitate the procedure.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Razão Sinal-Ruído , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Biópsia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
IEEE Trans Med Imaging ; 42(1): 220-232, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36112565

RESUMO

Computed tomography (CT) as an important clinical diagnostics method can profit from extension with dark-field imaging, as it is currently restricted to X-rays' attenuation contrast only. Dark-field imaging allows access to more tissue properties, such as micro-structural texture or porosity. The up-scaling process to clinical scale is complex because several design constraints must be considered. The two most important ones are that the finest grating is limited by current manufacturing technology to a [Formula: see text] period and that the interferometer should fit into the CT gantry with minimal modifications only. In this work we discuss why an inverse interferometer and a triangular G1 profile are advantageous and make a compact and sensitive interferometer implementation feasible. Our evaluation of the triangular grating profile reveals a deviation in the interference pattern compared to standard grating profiles, which must be considered in the subsequent data processing. An analysis of the grating orientation demonstrates that currently only a vertical layout can be combined with cylindrical bending of the gratings. We also provide an in-depth discussion, including a new simulation approach, of the impact of the extended X-ray source spot which can lead to large performance loss and present supporting experimental results. This analysis reveals a vastly increased sensitivity to geometry and grating period deviations, which must be considered early in the system design process.


Assuntos
Interferometria , Tomografia Computadorizada por Raios X , Humanos , Interferometria/métodos , Tomografia Computadorizada por Raios X/métodos , Radiografia , Raios X , Simulação por Computador
4.
Proc Natl Acad Sci U S A ; 119(8)2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35131900

RESUMO

X-ray computed tomography (CT) is one of the most commonly used three-dimensional medical imaging modalities today. It has been refined over several decades, with the most recent innovations including dual-energy and spectral photon-counting technologies. Nevertheless, it has been discovered that wave-optical contrast mechanisms-beyond the presently used X-ray attenuation-offer the potential of complementary information, particularly on otherwise unresolved tissue microstructure. One such approach is dark-field imaging, which has recently been introduced and already demonstrated significantly improved radiological benefit in small-animal models, especially for lung diseases. Until now, however, dark-field CT could not yet be translated to the human scale and has been restricted to benchtop and small-animal systems, with scan durations of several minutes or more. This is mainly because the adaption and upscaling to the mechanical complexity, speed, and size of a human CT scanner so far remained an unsolved challenge. Here, we now report the successful integration of a Talbot-Lau interferometer into a clinical CT gantry and present dark-field CT results of a human-sized anthropomorphic body phantom, reconstructed from a single rotation scan performed in 1 s. Moreover, we present our key hardware and software solutions to the previously unsolved roadblocks, which so far have kept dark-field CT from being translated from the optical bench into a rapidly rotating CT gantry, with all its associated challenges like vibrations, continuous rotation, and large field of view. This development enables clinical dark-field CT studies with human patients in the near future.


Assuntos
Espalhamento a Baixo Ângulo , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Humanos , Imageamento Tridimensional , Interferometria/métodos , Imagens de Fantasmas , Radiografia , Tomógrafos Computadorizados , Raios X
5.
Med Phys ; 48(10): 6152-6159, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34314019

RESUMO

PURPOSE: The purpose of this study was to evaluate the dose characteristic for patient examinations at the first clinical X-ray dark-field chest radiography system and to determine whether the effective patient dose is within a clinically acceptable dose range. METHODS: A clinical setup for grating-based dark-field chest radiography was constructed and commissioned, operating at a tube voltage of 70 kVp. Thermoluminescent dosimeter (TLD) measurements were conducted using an anthropomorphic phantom modeling the reference person to obtain a conversion coefficient relating dose area product (DAP) to effective patient dose at the dark-field system. For 92 patients, the DAP values for posterior-anterior measurements were collected at the dark-field system. Using the previously determined conversion coefficient, the effective dose was calculated. RESULTS: A reference person, modeled by an anthropomorphic phantom, receives an effective dose of 35 µSv. For the examined patients, a mean effective dose of 39 µSv was found. CONCLUSIONS: The effective dose at the clinical dark-field radiography system, generating both attenuation and dark-field images, is within the range of reported standard dose values for chest radiography.


Assuntos
Radiometria , Dosimetria Termoluminescente , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiografia
6.
Cancers (Basel) ; 12(5)2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32456049

RESUMO

Imaging techniques such as computed tomographies (CT) play a major role in clinical imaging and diagnosis of malignant lesions. In recent years, metal nanoparticle platforms enabled effective payload delivery for several imaging techniques. Due to the possibility of surface modification, metal nanoparticles are predestined to facilitate molecular tumor targeting. In this work, we demonstrate the feasibility of anti-plasma membrane Heat shock protein 70 (Hsp70) antibody functionalized gold nanoparticles (cmHsp70.1-AuNPs) for tumor-specific multimodal imaging. Membrane-associated Hsp70 is exclusively presented on the plasma membrane of malignant cells of multiple tumor entities but not on corresponding normal cells, predestining this target for a tumor-selective in vivo imaging. In vitro microscopic analysis revealed the presence of cmHsp70.1-AuNPs in the cytosol of tumor cell lines after internalization via the endo-lysosomal pathway. In preclinical models, the biodistribution as well as the intratumoral enrichment of AuNPs were examined 24 h after i.v. injection in tumor-bearing mice. In parallel to spectral CT analysis, histological analysis confirmed the presence of AuNPs within tumor cells. In contrast to control AuNPs, a significant enrichment of cmHsp70.1-AuNPs has been detected selectively inside tumor cells in different tumor mouse models. Furthermore, a machine-learning approach was developed to analyze AuNP accumulations in tumor tissues and organs. In summary, utilizing mHsp70 on tumor cells as a target for the guidance of cmHsp70.1-AuNPs facilitates an enrichment and uniform distribution of nanoparticles in mHsp70-expressing tumor cells that enables various microscopic imaging techniques and spectral-CT-based tumor delineation in vivo.

7.
Biomed Phys Eng Express ; 6(5): 055021, 2020 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33444252

RESUMO

OBJECTIVES: To study whether a dual-layer spectral CT scout scan-based areal BMD estimation method, called Spectral-detector based x-ray absorptiometry (SDXA), can differentiate patients with versus without osteoporotic fractures. METHODS: The ability of the method to differentiate patients with osteoporosis was evaluated by assessing the areal BMD at the spine (L1 to L4) in a group of 19 patients presenting at least one fracture and comparing these results to the areal BMD of age- and gender-matched controls (57 patients). Finally, the reproducibility of SDXA was evaluated in-vivo through the calculation of coefficients of variation (CV), using three repeated analyses performed on each patient. RESULTS: The average areal BMD of patients presenting fractures, measured with the scout scan-based method (0.86 ± 0.17 g cm-2), was found to be significantly lower than the average BMD of the control group (1.00 ± 0.17 g cm-2, p = 0.043). The reproducibility of the method in-vivo was found to be reasonable, with CVs ranging between 3.1 and 6.9%. CONCLUSIONS: The results illustrate that the SDXA method for DXA-equivalent areal BMD estimation -delivers the ability to distinguish patients presenting osteoporotic fractures. Considering the total number of CT examinations worldwide, SDXA could develop to be a useful tool for truly opportunistic osteoporosis screening for a future clinical day-to-day routine.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea , Osteoporose/patologia , Fraturas por Osteoporose/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico por imagem
8.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31073861

RESUMO

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Análise de Variância , Artefatos , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Segurança do Paciente , Doses de Radiação , Sensibilidade e Especificidade
9.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30758656

RESUMO

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Assuntos
Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Fatores Etários , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
10.
Sci Rep ; 8(1): 17386, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30478300

RESUMO

The purpose of this study was to investigate a preclinical spectral photon-counting CT (SPCCT) prototype compared to conventional CT for pulmonary imaging. A custom-made lung phantom, including nodules of different sizes and shapes, was scanned with a preclinical SPCCT and a conventional CT in standard and high-resolution (HR-CT) mode. Volume estimation was evaluated by linear regression. Shape similarity was evaluated with the Dice similarity coefficient. Spatial resolution was investigated via MTF for each imaging system. In-vivo rabbit lung images from the SPCCT system were subjectively reviewed. Evaluating the volume estimation, linear regression showed best results for the SPCCT compared to CT and HR-CT with a root mean squared error of 21.3 mm3, 28.5 mm3 and 26.4 mm3 for SPCCT, CT and HR-CT, respectively. The Dice similarity coefficient was superior for SPCCT throughout nodule shapes and all nodule sizes (mean, SPCCT: 0.90; CT: 0.85; HR-CT: 0.85). 10% MTF improved from 10.1 LP/cm for HR-CT to 21.7 LP/cm for SPCCT. Visual investigation of small pulmonary structures was superior for SPCCT in the animal study. In conclusion, the SPCCT prototype has the potential to improve the assessment of lung structures due to higher resolution compared to conventional CT.


Assuntos
Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Humanos , Modelos Lineares , Imagens de Fantasmas , Fótons , Coelhos
11.
PLoS One ; 13(9): e0204565, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30261038

RESUMO

Disorders of the lungs such as chronic obstructive pulmonary disease (COPD) are a major cause of chronic morbidity and mortality and the third leading cause of death in the world. The absence of sensitive diagnostic tests for early disease stages of COPD results in under-diagnosis of this treatable disease in an estimated 60-85% of the patients. In recent years a grating-based approach to X-ray dark-field contrast imaging has shown to be very sensitive for the detection and quantification of pulmonary emphysema in small animal models. However, translation of this technique to imaging systems suitable for humans remains challenging and has not yet been reported. In this manuscript, we present the first X-ray dark-field images of in-situ human lungs in a deceased body, demonstrating the feasibility of X-ray dark-field chest radiography on a human scale. Results were correlated with findings of computed tomography imaging and autopsy. The performance of the experimental radiography setup allows acquisition of multi-contrast chest X-ray images within clinical boundary conditions, including radiation dose. Upcoming clinical studies will have to demonstrate that this technology has the potential to improve early diagnosis of COPD and pulmonary diseases in general.


Assuntos
Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , Autopsia , Cadáver , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Humanos , Interferometria/instrumentação , Interferometria/métodos , Pneumopatias/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/instrumentação , Radiografia Torácica/estatística & dados numéricos , Tomografia Computadorizada por Raios X
12.
Sci Rep ; 8(1): 2602, 2018 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-29422512

RESUMO

The aim of this study was to assess the diagnostic value of x-ray dark-field radiography to detect pneumothoraces in a pig model. Eight pigs were imaged with an experimental grating-based large-animal dark-field scanner before and after induction of a unilateral pneumothorax. Image contrast-to-noise ratios between lung tissue and the air-filled pleural cavity were quantified for transmission and dark-field radiograms. The projected area in the object plane of the inflated lung was measured in dark-field images to quantify the collapse of lung parenchyma due to a pneumothorax. Means and standard deviations for lung sizes and signal intensities from dark-field and transmission images were tested for statistical significance using Student's two-tailed t-test for paired samples. The contrast-to-noise ratio between the air-filled pleural space of lateral pneumothoraces and lung tissue was significantly higher in the dark-field (3.65 ± 0.9) than in the transmission images (1.13 ± 1.1; p = 0.002). In case of dorsally located pneumothoraces, a significant decrease (-20.5%; p > 0.0001) in the projected area of inflated lung parenchyma was found after a pneumothorax was induced. Therefore, the detection of pneumothoraces in x-ray dark-field radiography was facilitated compared to transmission imaging in a large animal model.


Assuntos
Pulmão/diagnóstico por imagem , Pneumotórax/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Radiografia/métodos , Suínos , Raios X
13.
Eur Radiol ; 28(8): 3318-3325, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460069

RESUMO

OBJECTIVES: After endovascular aortic repair (EVAR), discrimination of endoleaks and intra-aneurysmatic calcifications within the aneurysm often requires multiphase computed tomography (CT). Spectral photon-counting CT (SPCCT) in combination with a two-contrast agent injection protocol may provide reliable detection of endoleaks with a single CT acquisition. METHODS: To evaluate the feasibility of SPCCT, the stent-lined compartment of an abdominal aortic aneurysm phantom was filled with a mixture of iodine and gadolinium mimicking enhanced blood. To represent endoleaks of different flow rates, the adjacent compartments contained either one of the contrast agents or calcium chloride to mimic intra-aneurysmatic calcifications. After data acquisition with a SPCCT prototype scanner with multi-energy bins, material decomposition was performed to generate iodine, gadolinium and calcium maps. RESULTS: In a conventional CT slice, Hounsfield units (HU) of the compartments were similar ranging from 147 to 168 HU. Material-specific maps differentiate the distributions within the compartments filled with iodine, gadolinium or calcium. CONCLUSION: SPCCT may replace multiphase CT to detect endoleaks without sacrificing diagnostic accuracy. It is a unique feature of our method to capture endoleak dynamics and allow reliable distinction from intra-aneurysmatic calcifications in a single scan, thereby enabling a significant reduction of radiation exposure. KEY POINTS: • SPCCT might enable advanced endoleak detection. • Material maps derived from SPCCT can differentiate iodine, gadolinium and calcium. • SPCCT may potentially reduce radiation burden for EVAR patients under post-interventional surveillance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Fótons , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
14.
Sci Rep ; 7(1): 7476, 2017 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-28785015

RESUMO

Grating-based X-ray interferometry offers vast potential for imaging materials and tissues that are not easily visualised using conventional X-ray imaging. Tomographic reconstruction based on X-ray interferometric data provides not only access to the attenuation coefficient of an object, but also the refractive index and information about ultra-small-angle scattering. This improved functionality comes at the cost of longer measurement times because existing projection-based signal extraction algorithms require not only a single measurement per projection angle but several with precise grating movements in between. This obstacle hinders the adaptation of grating-based interferometry into a continuously rotating gantry. Several solutions to this problem have been proposed but all suffer from major drawbacks. We present results using an iterative reconstruction algorithm working directly on the interferograms. The suggested direct approach enables improved image quality, since interpolations and unnecessary assumptions about the object are circumvented. Our results demonstrate that it is possible to successfully reconstruct the linear attenuation coefficient, the refractive index and the linear diffusion coefficient, which is a measure related to ultra-small-angle scattering, using a single measurement per projection angle and without any grating movements. This is a milestone for future clinical implementation of grating-based phase-contrast and dark-field contrast X-ray computed tomography.

15.
Sci Rep ; 7(1): 4807, 2017 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-28684858

RESUMO

X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the first in-vivo XDF full-field chest radiographs (32 × 35 cm2) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 µSv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.


Assuntos
Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Masculino , Radiografia Torácica/instrumentação , Suínos , Tomografia Computadorizada por Raios X/instrumentação
16.
Radiology ; 283(3): 723-728, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27918709

RESUMO

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.


Assuntos
Colonografia Tomográfica Computadorizada , Colonografia Tomográfica Computadorizada/métodos , Meios de Contraste , Gadolínio , Compostos de Iodo , Imagens de Fantasmas , Fótons
17.
Eur Radiol Exp ; 1(1): 25, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29708205

RESUMO

BACKGROUND: To assess the feasibility of dual-contrast spectral photon-counting computed tomography (SPCCT) for liver imaging. METHODS: We present an SPCCT in-silico study for simultaneous mapping of the complementary distribution in the liver of two contrast agents (CAs) subsequently intravenously injected: a gadolinium-based contrast agent and an iodine-based contrast agent. Four types of simulated liver lesions with a characteristic arterial and portal venous pattern (haemangioma, hepatocellular carcinoma, cyst, and metastasis) are presented. A material decomposition was performed to reconstruct quantitative iodine and gadolinium maps. Finally, a multi-dimensional classification algorithm for automatic lesion detection is presented. RESULTS: Our simulations showed that with a single-scan SPCCT and an adapted contrast injection protocol, it was possible to reconstruct contrast-enhanced images of the liver with arterial distribution of the iodine-based CA and portal venous phase of the gadolinium-based CA. The characteristic patterns of contrast enhancement were visible in all liver lesions. The approach allowed for an automatic detection and classification of liver lesions using a multi-dimensional analysis. CONCLUSIONS: Dual-contrast SPCCT should be able to visualise the characteristic arterial and portal venous enhancement with a single scan, allowing for an automatic lesion detection and characterisation, with a reduced radiation exposure.

18.
Med Phys ; 43(3): 1295-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26936714

RESUMO

PURPOSE: An analytic Fourier approach to predict the expected number of counts registered in a photon-counting detector subject to pulse pile-up for arbitrary photon flux, detector response function, and pulse-shape is presented. The analysis provides a complete forward model for energy-sensitive, photon-counting x-ray detectors for spectral computed tomography. METHODS: The formalism of the stochastic theory of the expected frequency of level crossings of shot noise processes is applied to the pulse pile-up effect and build on a recently published analytic Fourier representation of the level crossing frequency of shot noise processes with piece-wise continuous kernels with jumps. RESULTS: The general analytic result is validated by a Monte Carlo simulation for pulses of the form g(t) = e(-t/τ) (t > 0) and a Gaussian detector response function. The Monte Carlo simulations are in excellent agreement with the analytic predictions of photon counts within the numerical accuracy of the calculations. CONCLUSIONS: The phenomenon of pulse pile-up is identified with the level-crossing problem of shot noise processes and an exact, analytic formula for the expected number of counts in energy-sensitive, photon-counting x-ray detectors for arbitrary photon flux, response function, and pulse-shapes is derived. The framework serves as a theoretical foundation for future works on pulse pile-up.


Assuntos
Análise de Fourier , Fótons , Radiometria/instrumentação , Método de Monte Carlo , Raios X
19.
ACS Nano ; 7(11): 9761-70, 2013 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-24127782

RESUMO

Low-density lipoprotein (LDL) plays a critical role in cholesterol transport and is closely linked to the progression of several diseases. This motivates the development of methods to study LDL behavior from the microscopic to whole-body level. We have developed an approach to efficiently load LDL with a range of diagnostically active nanocrystals or hydrophobic agents. We performed focused experiments on LDL labeled with gold nanocrystals (Au-LDL). The labeling procedure had minimal effect on LDL size, morphology, or composition. Biological function was found to be maintained from both in vitro and in vivo experiments. Tumor-bearing mice were injected intravenously with LDL, DiR-LDL, Au-LDL, or a gold-loaded nanoemulsion. LDL accumulation in the tumors was detected with whole-body imaging methods, such as computed tomography (CT), spectral CT, and fluorescence imaging. Cellular localization was studied with transmission electron microscopy and fluorescence techniques. This LDL labeling procedure should permit the study of lipoprotein biointeractions in unprecedented detail.


Assuntos
Ouro/química , Lipoproteínas LDL/química , Nanopartículas Metálicas/química , Nanopartículas/química , Animais , Carbocianinas/química , Colesterol/química , Feminino , Citometria de Fluxo , Células Hep G2 , Humanos , Melanoma Experimental , Camundongos , Camundongos Knockout , Camundongos Nus , Microscopia Eletrônica de Transmissão , Microscopia de Fluorescência , Transplante de Neoplasias , Fosfolipídeos/química , Tomografia Computadorizada por Raios X
20.
IEEE Trans Med Imaging ; 32(7): 1249-57, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23475351

RESUMO

Photon-counting detector technology has enabled the first experimental investigations of energy-resolved computed tomography (CT) imaging and the potential use for K-edge imaging. However, limitations in regards to detecter technology have been imposing a limit to effective count rates. As a consequence, this has resulted in high noise levels in the obtained images given scan time limitations in CT imaging applications. It has been well recognized in the area of low-dose imaging with conventional CT that iterative image reconstruction provides a superior signal to noise ratio compared to traditional filtered backprojection techniques. Furthermore, iterative reconstruction methods also allow for incorporation of a roughness penalty function in order to make a trade-off between noise and spatial resolution in the reconstructed images. In this work, we investigate statistically-principled iterative image reconstruction from material-decomposed sinograms in spectral CT. The proposed reconstruction algorithm seeks to minimize a penalized likelihood-based cost functional, where the parameters of the likelihood function are estimated by computing the Fisher information matrix associated with the material decomposition step. The performance of the proposed reconstruction method is quantitatively investigated by use of computer-simulated and experimental phantom data. The potential for improved K-edge imaging is also demonstrated in an animal experiment.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Simulação por Computador , Camundongos , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA