J Radiol Prot ; 38(2): 549-564, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29498356

RESUMO

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of the Monte Carlo (MC) code Penelope. The results obtained were validated against measurements performed in reference conditions in a secondary standard dosimetry laboratory. Next, the MC model was used to evaluate the backscatter correction factor needed for the case where the dosimeter is worn over a lead shield to estimate the personal equivalent dose H p (0.07) to unprotected soft tissues. For this purpose, the TLD was irradiated over a water slab phantom with a photon beam representative of the result of a fluoroscopy beam scattered by a patient. Incident beam angles of 0° and 60°, and lead thicknesses between the TLD and phantom of 0.25 and 0.5 mm Pb were considered. A backscatter correction factor of 1.23 (independent of lead thickness) was calculated comparing the results with those faced in reference conditions (i.e., without lead shield and with an angular incidence of 0°). The corrected dose algorithm was validated in laboratory conditions with dosimeters irradiated over a thyroid collar and angular incidences of 0°, 40° and 60°, as well as with dosimeters worn by interventional radiologists and cardiologists. The corrected dose algorithm provides a better approach to estimate the equivalent dose to unprotected soft tissues such as eye lenses. Dosimeters that are not shielded from backscatter radiation might underestimate personal equivalent doses when worn over a lead apron and, therefore, should be specifically characterized for this purpose.


Assuntos
Fluoroscopia/métodos , Dosímetros de Radiação/normas , Dosimetria Termoluminescente/normas , Calibragem , Desenho de Equipamento , Chumbo , Roupa de Proteção , Dosimetria Termoluminescente/instrumentação
2.
J Radiol Prot ; 35(4): N33-41, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26457404

RESUMO

The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to the OBI systems of the Clinac iX and the TrueBeam were 0.71 ± 0.07 mGy/CBCT and 0.70 ± 0.08 mGy/CBCT, respectively. The extra absorbed dose received by the eye lenses due to one CBCT acquisition with the studied protocol is far below the 500 mGy threshold established by ICRP for cataract formation (ICRP 2011 Statement on Tissue Reactions). However, the incremental effect of several CBCT acquisitions during the whole treatment should be taken into account.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cristalino/efeitos da radiação , Dosagem Radioterapêutica , Cabeça , Imagens de Fantasmas , Dosimetria Termoluminescente
3.
Phys Med ; 31(3): 286-92, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25681030

RESUMO

PURPOSE: To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose. METHODS: Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding. RESULTS: With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at 5 cm from the caudal edge of the breast to <0.1 cGy at 30 cm. The shielding reduces absorbed dose by a factor of two near the breast and more than an order of magnitude beyond 20 cm. The dose is heterogeneous within a given axial plane, with variations from the central region within 50%. Interstitial HDR (192)Ir brachytherapy with breast shielding can be more advantageous than external-beam radiotherapy (EBRT) from a radiation protection point of view, as long as the distance to the uterine fundus is higher than about 10 cm. Furthermore, the weight of the shielding here proposed is notably lower than that needed in EBRT. CONCLUSIONS: Shielded breast brachytherapy may benefit pregnant patients needing localized radiotherapy, especially during the early gestational ages when the fetus is more sensitive to ionizing radiation.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Feto/efeitos da radiação , Radioisótopos de Irídio/uso terapêutico , Complicações na Gravidez/radioterapia , Proteção Radiológica/instrumentação , Planejamento da Radioterapia Assistida por Computador , Adulto , Braquiterapia/efeitos adversos , Feminino , Humanos , Radioisótopos de Irídio/efeitos adversos , Gravidez , Radiometria , Dosagem Radioterapêutica
4.
J Radiol Prot ; 34(4): 741-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25222942

RESUMO

In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by (192)Ir and (60)Co will reduce the lead thickness by a factor of five for (192)Ir and ten for (60)Co. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers.The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness.


Assuntos
Braquiterapia/instrumentação , Instalações de Saúde , Arquitetura Hospitalar/métodos , Modelos Estatísticos , Proteção Radiológica/métodos , Radiometria/métodos , Simulação por Computador , Arquitetura Hospitalar/instrumentação , Método de Monte Carlo , Doses de Radiação , Espalhamento de Radiação , Espanha
5.
Phys Med ; 30(8): 954-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24998334

RESUMO

INTRODUCTION AND PURPOSE: Dosimetry Check (DC) (Math Resolutions) is a commercial EPID-based dosimetry software, which allows performing pre-treatment and transit dosimetry. DC provides an independent verification of the treatment, being potentially of great interest due to the high benefits of the in vivo volumetric dosimetry, which guarantee the treatment delivery and anatomy constancy. The aim of this work is to study the differences in dose between DC and the Treatment Planning System (TPS) to establish an accuracy level of the system. MATERIAL AND METHODS: DC v.3.8 was used along with Varian Clinac iX accelerator equipped with EPID aS1000 and Eclipse v.10.0 with AAA and Acuros XB calculation algorithms. The DC evaluated version is based on a pencil beam calculation algorithm. Various plans were generated over several homogeneous and heterogeneous phantoms. Isocentre point doses and gamma analysis were evaluated. RESULTS: Total dose differences at the isocentre between DC and TPS for the studied plans are less than 2%, but single field contributions achieve greater values. In the presence of heterogeneities, the discrepancies can reach up to 15%. In transit mode, DC does not consider properly the couch attenuation, especially when there is an air gap between phantom and couch. CONCLUSIONS: The possibility of this in vivo evaluation and the potentiality of this new system have a very positive impact on improving patient QA. But improvements are required in both calculation algorithm and integration with the record and verify system.


Assuntos
Radiometria/instrumentação , Radioterapia de Intensidade Modulada/métodos , Software , Algoritmos , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes
6.
Phys Med ; 28(3): 262-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21784685

RESUMO

PURPOSE: Dynamic delivery of intensity modulated beams (dIMRT) requires not only accurate verification of leaf positioning but also a control on the speed of motion. The latter is a parameter that has a major impact on the dose delivered to the patient. Time consumed in quality assurance (QA) procedures is an issue of relevance in any radiotherapy department. Electronic portal imaging dosimetry (EPID) can be very efficient for routine tests. The purpose of this work is to investigate the ability of our EPID for detecting small errors in leaf positioning, and to present our daily QA procedures for dIMRT based on EPID. METHODS AND MATERIALS: A Varian 2100 CD Clinac equipped with an 80 leaf Millennium MLC and with amorphous silicon based EPID (aS500, Varian) is used. The daily QA program consists in performing: Stability check of the EPID signal, Garden fence test, Sweeping slit test, and Leaf speed test. RESULTS AND DISCUSSION: The EPID system exhibits good long term reproducibility. The mean portal dose at the centre of a 10 × 10 cm(2) static field was 1.002 ± 0.004 (range 1.013-0.995) for the period evaluated of 47 weeks. Garden fence test shows that leaf position errors of up to 0.2 mm can be detected. With the Sweeping slit test we are able to detect small deviations on the gap width and errors of individual leaves of 0.5 and 0.2 mm. With the Leaf speed test problems due to motor fatigue or friction between leaves can be detected. CONCLUSIONS: This set of tests takes no longer than 5 min in the linac treatment room. With EPID dosimetry, a consistent daily QA program can be applied, giving complete information about positioning/speed MLC.


Assuntos
Equipamentos e Provisões Elétricas/normas , Radiometria/instrumentação , Radiometria/normas , Controle de Qualidade