Biomed Opt Express ; 14(10): 5488-5498, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37854562

RESUMO

Fogging is a non-invasive technique based on the use of positive spherical power lenses to relax accommodation during refraction that is commonly used as an alternative to cycloplegic drugs. Although the mechanism of the fogging technique has been described, some aspects of its methodology remain unclear. The main purpose of this work was to determine which lens power and time of application are more suitable for achieving a successful relaxation of accommodation by analyzing the changes in accommodation when fogging lenses of different powers were placed in front of the participants' eye for a certain timespan. The results of this analysis showed, in general, that low-power lenses and timespans of less than half a minute provided the highest relaxation of accommodation. However, high inter-subject variability was found in the two variables (power and time).

2.
PLoS One ; 18(5): e0284552, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37141181

RESUMO

Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants' negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research). Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively. Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements. Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar. A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes. The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.74 ± 3.35 PD and -1.97 ± 2.60 PD, respectively, which were comparable to those obtained for the subjective tests. For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.31 ± 6.44 PD and -2.84 ± 7.01 PD, respectively). This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests. However, these tests cannot be used interchangeably due to their poor agreement.


Assuntos
Convergência Ocular , Ligustrum , Adulto , Humanos , Estudos de Viabilidade , Visão Binocular , Cultura
3.
Biomed Opt Express ; 13(6): 3504-3519, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35781951

RESUMO

We examined the spectral reflectance of fundus structures in the visible and near-infrared (400-1300 nm) range for contributing to the medical diagnosis of fundus diseases. Spectral images of healthy eye fundus and other ocular diseases were acquired using a novel multispectral fundus camera. Reflectance metrics were computed based on contrast to analyze the spectral features. Significant differences were observed among the structures in healthy and diseased eye fundus. Specifically, near-infrared analysis allows imaging of deeper layers, such as the choroid, which, to date, has not been retrieved using traditional color fundus cameras. Pathological structures, which were hardly observable in color fundus images owing to metamerism, were also revealed by the developed multispectral fundus camera.

4.
Curr Eye Res ; 47(3): 391-398, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34738850

RESUMO

A previous work has reported a methodology to quantify intraocular scattering using a high sensitivity double-pass instrument with a robust index, the frequency scatter index. The purpose of our study was to evaluate an adaptation of the frequency scatter index for use in clinical double-pass systems. A prospective observational study was carried out in a group of patients with nuclear cataracts (n = 52) and in a control group (n = 11) using conventional double-pass systems. The frequency scatter index and the objective scatter index were used to assess the scattering. The Spearman coefficient was calculated to assess the correlation between both indexes, obtained from the double-pass images. Simultaneous measurements were performed with a double-pass and with a Hartmann-Shack wavefront sensor in the control group. The root-mean-square wavefront error and the full width at half maximum of the double-pass image were used to quantify the residual aberrations introduced by the variations in pupil size and retinal eccentricity. Measurement in eyes with different grades of cataracts shows a strong correlation (ρ = 0.929, p < .0001) between the frequency scatter index and the objective scatter index. A certain degree of correlation was observed between the objective scatter index and the root-mean-square and between the objective scatter index and the full width at half maximum, both for measurements with a different pupillary diameter and with a different retinal eccentricity (p < .05). No relationship was observed between the frequency scatter index and the root-mean-square or between the frequency scatter index and the full width at half maximum (p > .05). We have introduced and evaluated an adaptation of a methodology proposed recently for the measurement of intraocular scattering using the double-pass technique with a robust index, which is less affected by ocular aberrations. The frequency scatter index can be applied to conventional double-pass instruments available in clinical environments.


Assuntos
Catarata , Luz , Catarata/diagnóstico , Humanos , Retina , Espalhamento de Radiação , Visão Ocular
5.
Vision Res ; 187: 27-40, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34147850

RESUMO

The near point of convergence test is widely used to evaluate binocular vision. It assesses the ability of the eyes to converge at short distances. Although the test consists of a pure symmetrical vergence task, small involuntary saccades occur concurrently. The main goal of this study was to analyze saccadic characteristics as a function of vergence demand when testing the near point of convergence. To this purpose, the eye movements of 11 participants were registered with an eye-tracker while they performed the near point of convergence test by following a target that traveled forward and backward on a motorized bench. Saccade amplitude increased and, on average, saccade rate decreased with vergence demand. In general, the direction of the concurrent vergence movement had no significant effect on saccade characteristics. However, each individual subject showed idiosyncratic behavior. Most saccades tended to be corrective in terms of both binocular disparity and individual fixation position errors. In particular, most participants tended to correct the fixation position error of the dominant eye.


Assuntos
Convergência Ocular , Movimentos Sacádicos , Humanos , Motivação , Disparidade Visual , Visão Binocular
6.
Biomed Opt Express ; 12(3): 1263-1278, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796352

RESUMO

Whole eye visualization and morphometry are of high relevance in clinical practice. However, most standard ophthalmic OCT instruments are dedicated either to retinal or to anterior segment imaging. We demonstrate a swept source optical coherence tomography system (SS-OCT) that images both the whole anterior segment and the retina alternately using a single source and detector. A pilot population was imaged with the proof of concept prototype. We demonstrate the clinical potential of whole eye OCT screening for the description and early detection of relevant clinical features in the anterior segment and retina of several patients.

7.
J Opt Soc Am A Opt Image Sci Vis ; 36(5): 918-924, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31045021

RESUMO

Double-pass systems rely on backscattering of light by the human ocular fundus to assess the optical quality of the eye. In this work, we present a method to reduce double-pass image degradation caused by undesired multiple scattering effects in the eye fundus. The reduction is based on combined data processing of simultaneous measurements using two different configurations: one symmetric with equal entrance and exit pupils and another asymmetric with unequal entrance and exit pupils. Under certain conditions, such scattering effects may be effectively suppressed. Measurements of human eyes show that, although multiple fundus scattering imposes a shift on the estimations, double-pass systems can be used to predict the optical quality of the eye within a population.


Assuntos
Artefatos , Fundo de Olho , Luz , Espalhamento de Radiação , Adulto , Humanos , Processamento de Imagem Assistida por Computador , Adulto Jovem
8.
Optom Vis Sci ; 96(6): 424-433, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31107844

RESUMO

SIGNIFICANCE: The effect of predictability in changes of time, magnitude, and direction of the accommodation demand on the accommodation response latency and its magnitude are insignificant, which suggests that repetitive accommodative tasks such as the clinical accommodative facility test may not be influenced by potential anticipation effects. PURPOSE: The purpose of this study was to investigate the effect of stimulus' time, magnitude, and direction predictability, as well as their interactions, on accommodation latency and response magnitude. METHODS: Monocular accommodative response and latency were measured in 12 young subjects for nine different conditions where the stimulus accommodative demand changed several times in a steplike fashion for a period of 120 seconds. Each change in accommodative demand could have different time duration (i.e., 1, 2, or 3 seconds), magnitude (1, 2, or 3 diopters), and/or direction (i.e., accommodation or disaccommodation). All conditions were created permuting the factors of time, magnitude, and direction with two levels each: random and not random. The baseline condition was a step signal from 0 to 2 diopters persisting for 2 seconds in both accommodative demands. After each condition, subjects were asked to provide a score from 1 to 5 in their perceived predictability. RESULTS: Friedman test conducted on the perceived predictability of each condition resulted in statistically significant differences between the nine conditions (χ = 56.57, P < .01). However, repeated-measures analysis of variance applied to latency and accommodative response magnitude did not show significant differences (P > .05). In addition, no correlation was found between the perceived predictability scores and both latency and accommodative response magnitudes between the most predictable and the most unpredictable conditions. CONCLUSIONS: Subjects were able to perceptually notice whether the stimulus was predictable or not, although our results indicate no significant effect of stimuli predictability on either the accommodation latency or its magnitude.


Assuntos
Acomodação Ocular/fisiologia , Generalização da Resposta/fisiologia , Tempo de Reação/fisiologia , Adulto , Feminino , Humanos , Masculino , Fatores de Tempo , Adulto Jovem
9.
Acta Ophthalmol ; 97(7): e1019-e1026, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31050166

RESUMO

PURPOSE: To assess forward intraocular scattering by means of a new parameter (Frequency Scatter Index, FSI3 ) based on the analysing double-pass retinal images in the frequency domain, which minimizes the impact of aberrations on the results. METHODS: A prospective observational study was carried out in the Department of Ophthalmology, Hospital Universitari Mútua de Terrassa (Spain) on a group of 19 patients diagnosed with nuclear cataracts of various LOCSIII grades and a control group (CG) with nine healthy eyes. We recorded double-pass retinal images with a custom set-up based on a high-sensitivity digital camera. The FSI3 was then computed using spatial frequencies below three cycles per degree. A preliminary validation of the FSI3 was performed on an artificial eye and two eyes of volunteers with and without commercial diffusers, and under defocus. RESULTS: The FSI3 was hardly affected by defocus values up to 2.50 D. The mean (and standard deviation) FSI3 values were as follows: for the CG, 1.19 (0.21); and for LOCSIII grades nuclear opacity 1, 2 and 3, 1.30 (0.12), 1.62 (0.21) and 1.85 (0.21), respectively. Eyes with cataracts showed FSI3 values significantly different than healthy eyes (p = 0.001). A good correlation (ρ = 0.861, p < 0.001) was found between the FSI3 and objective scatter index provided by a commercial instrument. CONCLUSION: Since aberrations have little impact on the FSI3 , the light scatter assessment becomes less dependent on the patient's refractive error compensation and the presence of higher-order aberrations. The FSI3 can further the clinical and scientific understanding of forward intraocular scattering.


Assuntos
Catarata/fisiopatologia , Córnea/efeitos da radiação , Luz , Espalhamento de Radiação , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Catarata/diagnóstico , Córnea/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
10.
J Optom ; 12(2): 74-83, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30389250

RESUMO

PURPOSE: To investigate a new algorithm to perform an automated non-cycloplegic refraction in adults. METHODS: Fifty healthy subjects were measured twice (test-retest) with the new automated subjective refraction method and with the conventional clinician subjective refraction procedure. Objective refraction was also measured with the Grand Seiko WAM-5500 autorefractor. The new automated method was inspired on the root finding bisection algorithm and on the Euclidean distances in the power vector domain. The algorithm was implemented in a computer that was synchronized with a customized motorized phoropter. Repeatability was mainly assessed with the within-subject standard deviation (Sw) and accuracy was mainly assessed with the limits of agreement. RESULTS: The within-subject standard deviations of the power vector components (M, J0, J45) obtained for the right eye are (±0.13, ±0.04, ±0.05)D and (±0.17, ±0.03, ±0.07)D, respectively, for the clinical and the automated subjective refraction methods. The limits of agreement (with the clinical method) for the automated and the objective methods are, respectively (±0.56, ±0.18, ±0.31)D and (±0.77, ±0.15, ±0.18)D. Similar results are obtained for the left eye. CONCLUSIONS: The proposed automated method is repeatable and more accurate than objective techniques in healthy adults. However, it is not accurate enough to replace the clinical subjective refraction yet and it should be tested in a wider population in terms of age, refraction and different ocular conditions. Despite these important limitations, this method has been shown to be a potentially valuable method to improve the access to primary eye care services in developing countries.


Assuntos
Algoritmos , Diagnóstico por Computador , Optometria/métodos , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Seleção Visual/métodos , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Optometria/instrumentação , Reprodutibilidade dos Testes , Seleção Visual/instrumentação
11.
PLoS One ; 13(11): e0206674, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30383846

RESUMO

Heterophoria is the relative deviation of the eyes in absence of fusional vergence. Fusional vergence can be deprived by, for example, occluding one eye while the other fixates a visual target. Then, the occluded eye will presumably deviate from its initial position by an amount that corresponds to the heterophoria. Its assessment in clinical practice is crucial for the diagnosis of non-strabismic binocular dysfunctions such as convergence insufficiency. Traditional clinical methods, like the cover test or the modified Thorington test, suffer from practitioner's subjectivity, impossibility to observe the occluding eye or unusual viewing conditions. These limitations could be overcome by using eye tracking systems to measure objectively the heterophoria. The main purpose of this study was to compare the performance of an automated and objective method to measure near heterophoria using an eye-tracker with two conventional methods: the cover-uncover test and the modified Thorington test. The eye tracking method gave us the possibility to measure the heterophoria as the deviation of the occluded eye (mimicking the cover test) or as the deviations of the occluded and fixating eyes (adhering to the theoretical definition of heterophoria). The latter method provided smaller results than the former, although on average the differences might not be clinically relevant. The proposed objective method exhibited considerably better repeatability than the two conventional clinical methods. It showed better agreement with the modified Thorington test than with the cover-uncover test, and a similar level of agreement was obtained between the two clinical methods. To conclude, the use of eye-trackers to measure heterophoria provides objective and more repeatable measures. As eye-trackers become common tools in clinical settings, their use to measure heterophoria should be the new gold standard.


Assuntos
Automação , Medições dos Movimentos Oculares , Estrabismo/diagnóstico , Adulto , Desenho de Equipamento , Feminino , Fixação Ocular , Humanos , Masculino , Estimulação Luminosa , Reprodutibilidade dos Testes , Adulto Jovem
12.
Curr Eye Res ; 43(6): 788-795, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29488815

RESUMO

PURPOSE: To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. RESULTS: The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. CONCLUSIONS: The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.


Assuntos
Acomodação Ocular/fisiologia , Astenopia/fisiopatologia , Miopia/fisiopatologia , Presbiopia/fisiopatologia , Visão Binocular/fisiologia , Adolescente , Adulto , Astenopia/diagnóstico , Feminino , Humanos , Cristalino/fisiopatologia , Masculino , Miopia/diagnóstico , Estimulação Luminosa , Presbiopia/diagnóstico , Testes Visuais , Adulto Jovem
13.
J Biomed Opt ; 23(3): 1-9, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29500875

RESUMO

A set of methods in terms of both image processing and gaze estimation for accurate eye tracking is proposed. The eye-tracker used in this study relies on the dark-pupil method with up to 12 corneal reflections and offers an unprecedented high resolution imaging of the pupil and the cornea. The potential benefits of a higher number of glints and their optimum arrangement are analyzed considering distinct light sources configurations with 12, 8, 6, 4, and 2 corneal reflections. Moreover, a normalization factor of the pupil-glint vector is proposed for each configuration. There is a tendency for increasing accuracy with the number of glints, especially vertically (0.47 deg for 12 glints configuration versus 0.65 deg for 2 glints configuration). Besides the number of corneal reflections, their arrangement seems to have a stronger effect. A configuration that minimizes the interference of the eyelids with the corneal reflections is desired. Finally, the normalization of the pupil-glint vectors improves the vertical eye tracking accuracy up to 43.2%. In addition, the normalization also limits the need for a higher number of light sources to achieve better spatial accuracy.


Assuntos
Córnea/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Movimentos Oculares/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Adulto , Desenho de Equipamento , Fixação Ocular/fisiologia , Humanos , Pupila/fisiologia , Adulto Jovem
14.
J Optom ; 11(3): 174-181, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29146479

RESUMO

PURPOSE: A single-center, cross-sectional study was designed to assess and compare objective and subjective quality of vision of patients intervened with penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK) and Descemet membrane endothelial keratoplasty (DMEK). METHODS: Forty-six patients previously intervened with PK (22 eyes), DALK (7 eyes) and DMEK (17 eyes) were recruited. Visual evaluation included spherical and cylindrical refraction, distance corrected visual acuity (DCVA), photopic contrast sensitivity (CS), optical quality, measured with the HD Analyzer (objective scattering index [OSI], MTF cut-off and Strehl ratio), and ocular and corneal aberrometry, measured with the KR-1W Wavefront Analyzer. RESULTS: Statistically significant between-group differences were found in age (p=0.006, DMEK patients were older) and time since surgery (p<0.001, longest time for PK patients). No statistically significant differences were found in DCVA between the techniques. Between-group differences were encountered in CS at 12 (p=0.007) and 18 (p<0.001) cycles per degree, with DMEK and DALK obtaining the best and worst outcomes, respectively. Differences in optical quality were found between the techniques (OSI, p=0.004; MTF cut-off, p=0.048; Strehl ratio p=0.022), with DMEK displaying the best outcomes. Highest and lowest values in ocular and corneal aberrations were for DALK and DMEK patients, respectively. Between-group differences were found in corneal astigmatism (p<0.001; -3.31±2.00 D in PK; -2.68±0.94 D in DALK; -1.09±0.62 D in DMEK). CONCLUSION: Overall, DMEK proved superior over PK and DALK in terms of quality of vision, with PK offering slightly better outcomes than DALK in most visual function parameters under evaluation.


Assuntos
Doenças da Córnea/cirurgia , Lâmina Limitante Posterior/cirurgia , Endotélio Corneano/cirurgia , Ceratoplastia Penetrante/métodos , Adulto , Idoso , Análise de Variância , Sensibilidades de Contraste/fisiologia , Doenças da Córnea/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
15.
Optom Vis Sci ; 94(12): 1120-1128, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29053487

RESUMO

SIGNIFICANCE: The accommodative response is more affected by the type of refractive error than the method of stimulation, field of view (FOV), or stimulus depth. PURPOSE: This study aims to analyze the effect of stimulation method, stimulus depth, and FOV on the accommodation response (AR) for emmetropes (EMM), late-onset myopes (LOM), and early-onset myopes (EOM). METHODS: Monocular AR was measured in 26 young observers (n = 9 EMM, n = 8 LOM, n = 9 EOM) under 60 different viewing conditions that were the result of permuting the following factors: (1) stimulation method (free space or Badal lens viewing), (2) stimulus depth (flat or volumetric), (3) FOV (2.5, 4, 8, 10, and 30°), and (4) accommodative stimulus (AS: 0.17, 2.50, and 5.00 diopters [D]). RESULTS: Mixed analysis of variance for 2.50 D of AS resulted in a significant effect of refractive group (F = 6.77, P < .01) and FOV (F = 1.26, P = .04). There was also a significant interaction between stimulus depth and FOV (F = 2.73, P = .03) and among stimulation method, FOV, and refractive group (F = 2.42, P = .02). For AS of 5.00 D, there was a significant effect of refractive group (F = 13.88, P < .01) and stimulation method (F = 5.16, P = .03). There was also a significant interaction of stimulation method, stimulus depth, and refractive group (F = 4.08, P = .03). When controlling for all interactions, LOM showed larger lags than EMM and EOM; the AR did not significantly change for fields of 8, 10, and 30°, and it did not significantly differ for different stimulation methods or stimulus depth. CONCLUSIONS: Previously reported differences in AR when using lens-based methods compared with free space viewing may be explained by the effect of other factors such as the FOV or the depth of the stimulus. Targets with an FOV of 8 or 10° may be optimal for accurate ARs.


Assuntos
Acomodação Ocular/fisiologia , Miopia/fisiopatologia , Adolescente , Adulto , Emetropia/fisiologia , Fixação Ocular/fisiologia , Humanos , Testes Visuais , Campos Visuais/fisiologia , Adulto Jovem
16.
Appl Opt ; 56(25): 7194-7203, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29047981

RESUMO

In this study, a novel gonio-hyperspectral imaging system based on light-emitting diodes for the analysis of automotive coatings was validated colorimetrically and spectrally from 368 to 1309 nm. A total of 30 pearlescent, 30 metallic, and 30 solid real automotive coatings were evaluated with this system, the BYK-mac and X-Rite MA98 gonio-spectrophotometers, and also with the SPECTRO 320 spectrometer for further comparison. The results showed very precise correlations, especially in the visible range. In conclusion, this new system provides a deeper assessment of goniochromatic pigments than current approaches due to the expansion of the spectral range to the infrared.

17.
Int J Ophthalmol ; 10(4): 567-572, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28503429

RESUMO

AIM: To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. METHODS: Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t-tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. RESULTS: The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. CONCLUSION: All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.

18.
Clin Exp Optom ; 100(6): 649-655, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28326607

RESUMO

BACKGROUND: The aim was to analyse the effect of peripheral depth cues on accommodation in Badal optometers. METHODS: Monocular refractions at 0.17 and 5.00 D of accommodative stimulus were measured with the PowerRef II autorefractor (Plusoptix Inc., Atlanta, Georgia, USA). Subjects looked (randomly) at four different scenes, one real scene comprising familiar objects at different depth planes (Real) and three virtual scenes comprising different two-dimensional pictures seen through a Badal lens. The first image consisted of a photograph of the real scene taken in conditions that closely mimic a healthy standard human eye performance (out-of-focus [OoF] blur); the second image was the same photograph rendered with a depth of focus to infinity (OoF sharpness); and finally the third image consisted of a fixation target and a even white surrounding (White). In all cases the field of view was 25.0° and the fixation target was a Maltese cross subtending to two degrees. RESULTS: Twenty-eight right eyes from healthy young subjects were measured. The achieved statistical power was 0.9. At 5.00 D of accommodative stimulus, the repeated measures analysis of variance was statistically significant (p < 0.05) and the corresponding Bonferroni post hoc tests showed the following mean accommodative response differences and standard deviation (p-value) between the real and the virtual scenes: real-white =-0.66 ± 0.92 D (p < 0.01); real-OoF sharpness = -0.43 ± 0.88 D (p = 0.07); real-OoF blur =-0.25 ± 0.93 D (p = 0.89). CONCLUSIONS: A stimulus poor in depth cues inaccurately stimulates accommodation in Badal optometers; however, accommodation can be significantly improved in the same Badal optometer, when displaying a realistic image rich in peripheral depth cues, even though these peripheral cues (also referred to as retinal blur cues) are shown in the same plane as the fixation target. These results have important implications in stereoscopic virtual reality systems that fail to represent appropriately retinal blur.


Assuntos
Acomodação Ocular/fisiologia , Sinais (Psicologia) , Percepção de Profundidade/fisiologia , Optometria/instrumentação , Adulto , Fixação Ocular/fisiologia , Voluntários Saudáveis , Humanos , Interface Usuário-Computador , Acuidade Visual/fisiologia , Adulto Jovem
19.
J Optom ; 10(1): 43-51, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-26856962

RESUMO

PURPOSE: To conduct a clinical validation of a virtual reality-based experimental system that is able to assess the spherical subjective refraction simplifying the methodology of ocular refraction. METHODS: For the agreement assessment, spherical refraction measurements were obtained from 104 eyes of 52 subjects using three different methods: subjectively with the experimental prototype (Subj.E) and the classical subjective refraction (Subj.C); and objectively with the WAM-5500 autorefractor (WAM). To evaluate precision (intra- and inter-observer variability) of each refractive tool independently, 26 eyes were measured in four occasions. RESULTS: With regard to agreement, the mean difference (±SD) for the spherical equivalent (M) between the new experimental subjective method (Subj.E) and the classical subjective refraction (Subj.C) was -0.034D (±0.454D). The corresponding 95% Limits of Agreement (LoA) were (-0.856D, 0.924D). In relation to precision, intra-observer mean difference for the M component was 0.034±0.195D for the Subj.C, 0.015±0.177D for the WAM and 0.072±0.197D for the Subj.E. Inter-observer variability showed worse precision values, although still clinically valid (below 0.25D) in all instruments. CONCLUSIONS: The spherical equivalent obtained with the new experimental system was precise and in good agreement with the classical subjective routine. The algorithm implemented in this new system and its optical configuration has been shown to be a first valid step for spherical error correction in a semiautomated way.


Assuntos
Optometria/métodos , Erros de Refração/diagnóstico , Refratometria , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Refração Ocular , Refratometria/instrumentação , Refratometria/normas , Reprodutibilidade dos Testes , Adulto Jovem
20.
Ophthalmic Physiol Opt ; 37(1): 88-95, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27774618

RESUMO

PURPOSE: To study whether the accommodation response to Badal optometer is equivalent to the response for real space targets. METHODS: Accommodative responses were measured for 28 young eyes with the WAM-5500 autorefractometer in eight configurations for 0.17 D, 2.0 D and 5.0 D accommodation stimuli. Parameters that might contribute to differences in response were systematically isolated: stimulation method (real space vs Badal targets), field of view, instrument's cover proximity, the looming effect, and the peripheral interposition of objects in depth. RESULTS: Mean accommodative response differences between a natural view configuration and a configuration with a Badal Optometer were 0.50 ± 0.43 D and 0.58 ± 0.53 D for 2.0 D and 5.0 D stimulation, respectively (p < 0.001), with accommodation lags for the latter condition. Of the isolated parameters that might contribute to these differences, varying the interposition of objects in depth affected accommodation response more markedly. CONCLUSIONS: It is likely that Badal optometers affect accommodation through a combination of some or all of the studied parameters. We conclude that accommodation response to closed-view Badal optometers is not equivalent to real space target response.


Assuntos
Acomodação Ocular/fisiologia , Óptica e Fotônica , Optometria/instrumentação , Adolescente , Adulto , Feminino , Humanos , Masculino , Matemática , Reprodutibilidade dos Testes , Adulto Jovem