J Med Imaging (Bellingham) ; 1(3): 033506, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26158058

RESUMO

The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

2.
Med Phys ; 40(8): 081907, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927321

RESUMO

PURPOSE: Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background "clutter" that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporal subtraction CEDM by a power law, with model parameters α and ß. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated. METHODS: The power law parameters, α and ß, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject. RESULTS: In DE CEDM, weighted image subtraction lowers ß to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing ß by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by about 2×10(-5) mm2, and lowers ß by about 0.14 compared to LE images. A comparison of SE and DE CEDM at 4 min postcontrast shows equivalent power law parameters in unprocessed images, and lower α and ß by about 3×10(-5) mm2 and 0.50, respectively, in DE versus SE subtracted images. CONCLUSIONS: Image subtraction in both SE and DE CEDM reduces ß by over a factor of 2, while maintaining α below that in DM. Given the equivalent α between SE and DE unprocessed CEDM images, and the smaller anatomical noise in the DE subtracted images, the DE approach may have an advantage over SE CEDM. It will be necessary to test this potential advantage in future lesion detectability experiments, which account for realistic lesion signals. The authors' results suggest that LE images could be used in place of DM images in CEDM exam interpretation.


Assuntos
Meios de Contraste , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Razão Sinal-Ruído , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade
3.
J Digit Imaging ; 22(5): 519-26, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17955296

RESUMO

Tomosynthesis is a 3-dimensional mammography technique that generates thin slices separated one to the other by typically 1 mm from source data sets. The relatively high image noise in these thin slices raises the value of 1-cm thick slices computed from the set of reconstructed slices for image interpretation. In an initial evaluation, we investigated the potential of different algorithms for generating thick slices from tomosynthesis source data (maximum intensity projection-MIP; average algorithm-AV, and image generation by means of a new algorithm, so-called softMip). The three postprocessing techniques were evaluated using a homogeneous phantom with one textured slab with a total thickness of about 5 cm in which two 0.5-cm-thick slabs contained objects to simulate microcalcifications, spiculated masses, and round masses. The phantom was examined by tomosynthesis (GE Healthcare). Microcalcifications were simulated by inclusion of calcium particles of four different sizes. The slabs containing the inclusions were examined in two different configurations: adjacent to each other and close to the detector and with the two slabs separated by two 1-cm thick breast equivalent material slabs. The reconstructed tomosynthesis slices were postprocessed using MIP, AV, and softMip to generate 1-cm thick slices with a lower noise level. The three postprocessing algorithms were assessed by calculating the resulting contrast versus background for the simulated microcalcifications and contrast-to-noise ratios (CNR) for the other objects. The CNRs of the simulated round and spiculated masses were most favorable for the thick slices generated with the average algorithm, followed by softMip and MIP. Contrast of the simulated microcalcifications was best for MIP, followed by softMip and average projections. Our results suggest that the additional generation of thick slices may improve the visualization of objects in tomosynthesis. This improvement differs from the different algorithms for microcalcifications, speculated objects, and round masses. SoftMip is a new approach combining features of MIP and average showing image properties in between MIP and AV.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Imagens de Fantasmas , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos