Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 11(1): 930, 2020 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-32071293

RESUMO

The development of qualitatively new measurement capabilities is often a prerequisite for critical scientific and technological advances. Here we introduce an unconventional quantum probe, an entangled neutron beam, where individual neutrons can be entangled in spin, trajectory and energy. The spatial separation of trajectories from nanometers to microns and energy differences from peV to neV will enable investigations of microscopic magnetic correlations in systems with strongly entangled phases, such as those believed to emerge in unconventional superconductors. We develop an interferometer to prove entanglement of these distinguishable properties of the neutron beam by observing clear violations of both Clauser-Horne-Shimony-Holt and Mermin contextuality inequalities in the same experimental setup. Our work opens a pathway to a future of entangled neutron scattering in matter.

2.
Rev Sci Instrum ; 90(3): 033705, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927791

RESUMO

The polarized neutron imaging technique provides a non-invasive method of characterizing localized magnetic fields inside superconductors. However, complete understanding of the magnetic field distribution has yet to be realized experimentally due to the complexity of the interaction between neutron polarization and magnetic field. In this article, we show that a well-defined and controlled magnetic field through the neutron path contributes to simplify the data analysis and makes future quantitative polarized neutron imaging possible. This is demonstrated in a set of experiments that visualize the magnetic field distribution inside and around the superconductors. The experimental results demonstrate that proper guide field setup allows the visualization of the magnetic field expulsion at the surface of the superconductor in the zero-field cooling condition, as well as the magnetic field trapped inside the superconductor under field cooling condition.

3.
Rev Sci Instrum ; 87(3): 033901, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27036785

RESUMO

We describe a simple, compact device for spherical neutron polarimetry measurements at small neutron scattering angles. The device consists of a sample chamber with very low (<0.01 G) magnetic field flanked by regions within which the neutron polarization can be manipulated in a controlled manner. This allows any selected initial and final polarization direction of the neutrons to be obtained. We have constructed a prototype device using high-T(c) superconducting films and mu-metal to isolate regions with different magnetic fields and tested device performance in transmission geometry. Finite-element methods were used to simulate the device's field profile and these have been verified by experiment using a small solenoid as a test sample. Measurements are reported using both monochromatic and polychromatic neutron sources. The results show that the device is capable of extracting sample information and distinguishing small angular variations of the sample magnetic field. As a more realistic test, we present results on the characterization of a 10 µm thick Permalloy film in zero magnetic field, as well as its response to an external magnetic field.

4.
Soft Matter ; 12(21): 4709-14, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-27021920

RESUMO

Stöber silica particles are used in a diverse range of applications. Despite their widespread industrial and scientific uses, information on the internal structure of the particles is non-trivial to obtain and is not often reported. In this work we have used spin-echo small angle neutron scattering (SESANS) in conjunction with ultra small angle X-ray scattering (USAXS) and pycnometry to study an aqueous dispersion of Stöber particles. Our results are in agreement with models which propose that Stöber particles have a porous core, with a significant fraction of the pores inaccessible to solvent. For samples prepared from the same master sample in a range of H2O : D2O ratio solutions we were able to model the SESANS results for the solution series assuming monodisperse, smooth surfaced spheres of radius 83 nm with an internal open pore volume fraction of 32% and a closed pore fraction of 10%. Our results are consistent with USAXS measurements. The protocol developed and discussed here shows that the SESANS technique is a powerful way to investigate particles much larger than those studied using conventional small angle scattering methods.

5.
Rev Sci Instrum ; 86(2): 023902, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25725858

RESUMO

We present a new instrument for spin echo small angle neutron scattering (SESANS) developed at the Low Energy Neutron Source at Indiana University. A description of the various instrument components is given along with the performance of these components. At the heart of the instrument are a series of resistive coils to encode the neutron trajectory into the neutron polarisation. These are shown to work well over a broad range of neutron wavelengths. Neutron polarisation analysis is accomplished using a continuously operating neutron spin filter polarised by Rb spin-exchange optical pumping of (3)He. We describe the performance of the analyser along with a study of the (3)He polarisation stability and its implications for SESANS measurements. Scattering from silica Stöber particles is investigated and agrees with samples run on similar instruments.

6.
Rev Sci Instrum ; 85(5): 053303, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24880360

RESUMO

A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ~30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ~98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 µm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.

7.
Soft Matter ; 10(17): 3016-26, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24695952

RESUMO

Using a neutron scattering technique that measures a statistically-averaged density correlation function in real space rather than the conventional reciprocal-space structure factor, we have measured correlations between poly(methyl-methacrylate) (PMMA) colloidal particles of several sizes suspended in decalin. The new method, called Spin Echo Small Angle Neutron Scattering (SESANS) provides accurate information about particle composition, including the degree of solvent penetration into the polymer brush grafted on to the PMMA spheres to prevent aggregation. It confirms for particles, between 85 nm and 150 nm in radius that inter-particle correlations closely follow the Percus-Yevick hard-sphere model when the colloidal volume-fraction is between 30% and 50% provided the volume-fraction is used as a fitted parameter. No particle aggregation occurs in these systems. When small amounts of polystyrene are added as a depletant to a concentrated suspension of PMMA particles, short-range clustering of the particles occurs and there is an increase in the frequency of near-neighbor contacts. Within a small range of depletant concentration, near-neighbor correlations saturate and large aggregates with power law density correlations are formed. SESANS clearly separates the short- and long-range correlations and shows that, in this case, the power-law correlations are visible for inter-particle distances larger than roughly two particle diameters. In some cases, aggregate sizes are within our measurement window, which can extend out to 16 microns in favorable cases. We discuss the advantages of SESANS for measurements of the structure of concentrated colloidal systems and conclude that the method offers several important advantages.

8.
Langmuir ; 21(9): 3910-4, 2005 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-15835954

RESUMO

We report a technique for the alignment of self-assembled protein systems, such as F-actin bundles and microtubules, in a surface-modified titanium or silicon microfluidic device. Assembling filamentous protein systems in a confined geometry produces highly aligned samples for structural and mechanical studies. Biomolecular self-assembly can be investigated in a controlled fashion under different molecular concentration gradients and conditions along a channel length. We have shown that surface-modified devices produced via a high aspect ratio etch process in titanium and silicon can be used to confine and control such macromolecular assemblies and present examples of F-actin bundles and microtubules in this system.


Assuntos
Materiais Biocompatíveis/química , Microtúbulos/química , Proteínas/química , Silício/química , Titânio/química , Actinas/química , Teste de Materiais , Microquímica , Microscopia Eletrônica de Varredura , Proteínas Associadas aos Microtúbulos/química , Estresse Mecânico
9.
Science ; 269(5232): 1801, 1995 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-17820230
11.
Phys Rev B Condens Matter ; 45(2): 602-612, 1992 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-10001098
13.
Phys Rev Lett ; 62(14): 1667-1670, 1989 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-10039733
14.
Phys Rev Lett ; 59(6): 708-711, 1987 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-10035850
15.
Science ; 211(4488): 1258, 1981 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-17779212
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA