Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37734641

RESUMO

BACKGROUND: The criteria for chest drain removal after lung resections remain vague and rely on personal experience instead of evidence. Because pleural fluid resorption is proportional to body weight, a weight-related approach seems reasonable. We examined the feasibility of a weight-adjusted fluid output threshold concerning postoperative respiratory complications and the occurrence of symptomatic pleural effusion after chest drain removal. Our secondary objectives were the hospital length of stay and pain levels before and after chest drain removal. METHODS: This was a single-center randomized controlled trial including 337 patients planned for open or thoracoscopic anatomical lung resections. Patients were randomly assigned postoperatively into 2 groups. The chest drain was removed in the study group according to a fluid output threshold calculated by the 5 mL × body weight (in kg)/24 hours formula. In the control group, our previous traditional fluid threshold of 200 mL/24 hours was applied. RESULTS: No differences were evident regarding the occurrence of pleural effusion and dyspnea at discharge and 30 days postoperatively. In the logistic regression analysis, the surgical modality was a risk factor for other complications, and age was the only variable influencing postoperative dyspnea. Time to chest drain removal was identical in both groups, and time to discharge was shorter after open surgery in the test group. CONCLUSIONS: No increased postoperative complications occurred with this weight-based formula, and a trend toward earlier discharge after open surgery was observed in the test group.

2.
Sci Rep ; 12(1): 4941, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35322134

RESUMO

Worldwide, health care professionals working in operating rooms (ORs) are exposed to electrocautery smoke on a daily basis. Aims of this study were to determine composition and concentrations of electrocautery smoke in the OR using mass spectrometry. Prospective observational study at a tertiary care academic center, involving 122 surgical procedures of which 84 were 1:1 computer randomized to smoke evacuation system (SES) versus no SES use. Irritating, toxic, carcinogenic and mutagenic VOCs were observed in OR air, with some exceeding permissible exposure limits (OSHA/NIOSH). Mean total concentration of harmful compounds was 272.69 ppb (± 189 ppb) with a maximum total concentration of harmful substances of 8991 ppb (at surgeon level, no SES). Maximum total VOC concentrations were 1.6 ± 1.2 ppm (minimally-invasive surgery) and 2.1 ± 1.5 ppm (open surgery), and total maximum VOC concentrations were 1.8 ± 1.3 ppm at the OR table 'at surgeon level' and 1.4 ± 1.0 ppm 'in OR room air' away from the operating table. Neither difference was statistically significant. In open surgery, SES significantly reduced maximum concentrations of specific VOCs at surgeon level, including aromatics and aldehydes. Our data indicate relevant exposure of health care professionals to volatile organic compounds in the OR. Surgical technique and distance to cautery devices did not significantly reduce exposure. SES reduced exposure to specific harmful VOC's during open surgery.Trial Registration Number: NCT03924206 (clinicaltrials.gov).


Assuntos
Exposição Ocupacional , Compostos Orgânicos Voláteis , Carcinógenos/análise , Eletrocoagulação/métodos , Exposição Ocupacional/análise , Salas Cirúrgicas , Estudos Prospectivos , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA