Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pediatrics ; 141(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29691284

RESUMO

: media-1vid110.1542/5727212367001PEDS-VA_2017-4065Video Abstract OBJECTIVES: Determine the performance of the American Academy of Pediatrics (AAP) critical congenital heart disease (CCHD) newborn screening algorithm and the impact of an alternative algorithm. METHODS: Screening was performed on term infants without a known CCHD diagnosis at or near 24 hours of age at a tertiary birth hospital by using the AAP algorithm from 2013 to 2016. Retrospective review from the birth hospital and the area's sole pediatric cardiac center identified true- and false-positives and true- and false-negatives. A simulation study modeled the results of a modified screening algorithm with a single repeat pulse oximetry test instead of 2. RESULTS: Screening results were collected on 77 148 newborns . By using the current AAP algorithm, 77 114 (99.96%) infants passed screening, 18 infants failed for an initial saturation of <90%, and 16 failed after not attaining a passing pulse oximetry level after 3 tests. There was 1 true-positive (total anomalous pulmonary venous return), 33 false-positives, and 6 false-negatives, yielding an overall specificity of 99.96%, a sensitivity of 14.3%, and a false-positive rate of 0.043%. Among false-positives, 10 (31.3%) had significant non-CCHD disease. Simulating the modified algorithm, sensitivity remained at 14.3%, and the false-positive rate increased to 0.054%. CONCLUSIONS: Although CCHD screening in a tertiary care birth hospital may not detect many new cases of CCHD, it can detect other important diseases in newborns. Modifying the screening algorithm to 1 repeat pulse oximetry test instead of 2 may detect additional infants with significant disease without a substantial increase in the false-positive rate.


Assuntos
Algoritmos , Cardiopatias Congênitas/diagnóstico , Triagem Neonatal/métodos , Oximetria/métodos , Humanos , Hipóxia/diagnóstico , Hipóxia/etiologia , Recém-Nascido , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
PLoS Curr ; : e4f99c5654147a, 2012 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-22866242

RESUMO

Purpose. The purpose of this study was to assess the desirability of Duchenne muscular dystrophy (DMD) screening, the effectiveness of the consent process, and the feasibility of conducting DMD screening in a pediatric office. Methods. Infant males who attended a 12-month routine well-child visit at a participating pediatric clinic were screened for DMD. Parents and providers completed post-screening questionnaires to assess their experiences with and attitudes toward screening. Results. A total of 264 male infants were screened for DMD. Approximately 78% of parents indicated support of voluntary DMD screening and 91% of providers were in favor of screening for DMD. About 75% of parents correctly answered three of five questions testing their knowledge of DMD screening. Conclusion. DMD screening is feasible in a pediatric office when conducted as part of a research study. Infant screening for DMD eventually could be offered in pediatric health care provider offices as an optional public health service outside of newborn screening.

3.
Hum Mutat ; 25(4): 413, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15776412

RESUMO

Biotinidase deficiency is a defect in the recycling of the vitamin biotin. Biotin supplementation can markedly improve the neurological and cutaneous symptoms of affected children and prevent symptoms in children identified by newborn screening or treated since birth. We have determined thirteen novel mutations in children with the disorder. Two nonsense mutations, eight single missense mutations, three allelic double missense mutations, and two are polymorphisms were identified in the biotinidase gene (BTD). One of the missense mutations, c.734G>A (p. C245Y), is the first to be reported that alters the cysteine in the putative location crucial for ester formation and binding of the biotinyl-moiety in the active site of the enzyme. These mutations add to the growing list of mutations that are helping to delineate structure/function relationships of the enzyme.


Assuntos
Deficiência de Biotinidase/diagnóstico , Deficiência de Biotinidase/genética , Biotinidase/genética , Mutação , Alelos , Sítios de Ligação , Biotina/química , Deficiência de Biotinidase/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA