Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Sci ; 3(2): 100275, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36950088

RESUMO

Purpose: To assess the intrasession repeatability of macular OCT angiography (OCTA) parameters in Alzheimer's disease (AD), mild cognitive impairment (MCI), Parkinson's disease (PD), and normal cognition (NC). Design: Cross sectional study. Subjects: Patients with a clinical diagnosis of AD, PD, MCI, or NC were imaged. Images with poor quality and of those with diabetes mellitus, glaucoma, or vitreoretinal disease were excluded from analysis. Methods Intervention or Testing: All participants were imaged using the Zeiss Cirrus HD-5000 with AngioPlex (Carl Zeiss Meditec, Software Version 11.0.0.29946) and repeat OCTA images were obtained for both eyes. Perfusion density (PFD), vessel density (VD), and Foveal avascular zone (FAZ) area were measured from 3 × 3 mm and 6 × 6 mm OCTA images centered on the fovea using an ETDRS grid overlay. Main Outcome Measures: Intraclass correlation coefficients were used to quantify repeatability of PFD, VD, and FAZ area measurements obtained from imaging. Results: 3 × 3 mm scans of 22 AD, 40 MCI, 21 PD, and 26 NC participants and 6 × 6 mm scans of 29 AD, 44 MCI, 29 PD, and 30 NC participants were analyzed. Repeatability values ranged from 0.64 (0.49-0.82) for 6 × 6 mm PFD in AD participants to 0.87 (0.67-0.92) for 3 × 3 mm PFD in AD participants. No significant differences were observed in repeatability between NC participants and those with neurodegenerative disease. Conclusions: Overall, similar OCTA repeatability was observed between NC participants and those with neurodegeneration. Regardless of diagnostic group, macular OCTA metrics demonstrated moderate to good repeatability. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

2.
J Glaucoma ; 30(1): 32-36, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32969920

RESUMO

PRECIS: The use of nylon wicks with fenestrations in nonvalved aqueous shunt surgery significantly reduces intraocular pressure (IOP) and glaucoma medication usage in the immediate postoperative period compared with the use of fenestrations alone. PURPOSE: To compare early postoperative IOP and medication usage in patients undergoing implantation of a nonvalved aqueous shunt device with fenestrations only or fenestrations with nylon wicks. METHODS: A retrospective review of all nonvalved aqueous shunt insertions completed by one surgeon (L.W.H.) was completed using current procedure terminology. Patients undergoing Baerveldt or ClearPath 350 mm2 aqueous shunt insertion with fenestrations only (n=37) or fenestrations with 2 nylon wicks were identified (n=92). All devices were ligated with 7-0 Vicryl (polyglactin) suture, and either 4 fenestrations or 2 fenestrations and two 9-0 nylon wicks were placed anterior to the ligature. Data regarding visual acuity (VA), IOP, number of glaucoma medications, and complications were collected from the preoperative visit just before surgery, postoperative day 1, week 3 (POW3), week 5, and month 2 (POM2). The main outcome measures were VA, IOP, number of glaucoma medications, and complications at all postoperative time points. RESULTS: There was no difference in logMAR VA between the 2 groups at any time point. At POW3, IOP was significantly lower in the wick group (14.6±7.7 vs. 18.1±8.7 mm Hg, P=0.03). Number of glaucoma medications used was significantly reduced in the wick group at POW3 (0.5±0.9 vs. 1.0±1.2, P=0.02) and POM2 (0.7±1.0 vs. 1.4±1.3, P=0.02). There was no significant increase in the overall rate of complications in the wick group, but there was a higher rate of transient hyphema (28% vs. 8%, P=0.02). CONCLUSIONS: The use of 2 nylon wicks with fenestrations in nonvalved aqueous shunt device implantation can significantly lower IOP and medication burden while awaiting the dissolution of the ligature suture.


Assuntos
Implantes para Drenagem de Glaucoma , Nylons , Humanos , Pressão Intraocular , Estudos Retrospectivos , Tonometria Ocular
3.
Am J Ophthalmol Case Rep ; 20: 100923, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32995666

RESUMO

PURPOSE: To describe a case of anterior ischemic optic neuropathy as a presenting sign of granulomatosis with polyangiitis. OBSERVATIONS: A previously healthy 50-year-old female developed right eye, then left eye, redness and pruritis and was diagnosed with allergic versus viral conjunctivitis. Five days later, she noted an acute decline in vision in the right eye, corresponding with a decrease on Snellen testing from 20/30 to 20/100 with correction. She was noted to have a right relative afferent pupillary defect, 2+ pallid disc edema, and OCT (Spectralis, Heidelberg Engineering, Carlsbad, CA) findings of significant retinal nerve fiber thickening. Review of systems revealed a three-month history fatigue, right-sided headaches, jaw claudication, bronchitis, cough without hemoptysis, and epistaxis, as well as interval development of a petechial rash across her body, migratory polyarthralgias, fevers, and tachycardia. ESR and CRP were markedly elevated, and the patient was admitted to the hospital for a systemic vasculitis workup. She was started on IV methylprednisolone. Her vision improved dramatically with steroids, measuring 20/50 with correction in the right eye after 24 hours and returning to baseline after five days. An extensive workup including imaging, bloodwork, and biopsies led to a diagnosis of granulomatosis with polyangiitis, with PR3-positive ANCA. CONCLUSIONS: Ocular findings, including anterior ischemic optic neuropathy, may be the presenting signs for patients with granulomatosis with polyangiitis. Prompt recognition and treatment with high-dose steroids and immunomodulatory therapy is important for visual recovery. IMPORTANCE: Prompt recognition of potential vasculitis-related vision loss can lead to timely initiation of vision-saving treatment.

4.
J AAPOS ; 24(4): 238-239, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32634554

RESUMO

Handheld optical coherence tomography (OCT) makes it possible to acquire intraoperative and clinical imaging in infants and children for whom standard OCT is not possible. In patients with a retinal pathology who are left aphakic after surgery, however, image clarity is affected by insufficient refractive correction with handheld OCT. We describe a technique for supplementing the refractive power of the handheld OCT device with an aphakic contact lens to improve image clarity.


Assuntos
Lentes de Contato , Tomografia de Coerência Óptica , Criança , Humanos , Lactente , Retina
5.
J Glaucoma ; 28(2): 165-171, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30689608

RESUMO

PURPOSE: Many surgeons remove the ripcord in the Baerveldt glaucoma drainage device to better control tube opening and intraocular pressure (IOP) lowering postoperatively. However, complications following Baerveldt implant surgery with or without ripcord removal are not well-characterized. We performed a prospective, randomized trial to test the hypothesis that scheduled ripcord removal decreases complications and final IOP. METHODS: Eighty-one patients were enrolled and randomized to scheduled ripcord removal at postoperative week 3 or to observation. They were followed for 6 months, and outcomes were compared between the 2 groups. RESULTS: Forty-four patients were randomized to scheduled ripcord removal and 37 to observation. The intervention group had a similar rate of total complications after ripcord removal (36% vs. 24%, P=0.24), a lower rate of tube fibrin obstruction (2.3% vs. 13.5%, P=0.05), and a larger decrease in the number of medications (1.3 vs. 0.49 fewer medications, P=0.01). The removal group's mean IOP decrease was 8.6 mm Hg and success rate was 59%, defined as 5 mm Hg

Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Cuidados Pós-Operatórios , Técnicas de Sutura , Idoso , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Qualidade de Vida , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
6.
J Glaucoma ; 27(2): 148-156, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29189540

RESUMO

PURPOSE: Traditionally, during trabeculectomy, Mitomycin-C (MMC) is applied to the tissues using surgical sponges. However, alternate modes of application exist. This study assessed the success rates, complication rates, final intraocular pressure (IOP), and bleb characteristics between patients receiving subtenon MMC application by sponge versus irrigation. PATIENTS AND METHODS: A total of 100 patients with glaucoma were enrolled and each was randomized to 1 of the 2 treatment groups. Patients underwent trabeculectomy with Ex-PRESS shunt and MMC placement and were followed for 6 months. Complication rates assessed included bleb failure, bleb leaks, bleb encapsulation, and hypotony, amongst others. Additional factors evaluated included bleb morphology, glaucoma drop usage, Fluorouracil (5-FU) application, bleb revision, and subsequent glaucoma surgery. RESULTS: The irrigation method provided greater IOP lowering effects (P=0.03); correspondingly the irrigation group had higher rates of hypotony (P=0.03) but with no significant consequences. Patients who had trabeculectomy/Ex-PRESS alone had greater IOP reduction than those who had concurrent cataract surgery (P<0.001). The sponge group had higher rates of 5-FU use (P=0.007) and higher reoperation rates (P=0.02) when compared with the irrigation group. Success was defined as achieving 4 mm Hg≤IOP≤15 mm Hg without any anatomical bleb failure or subsequent glaucoma surgery. The overall success rate was 87%. CONCLUSIONS: Application of subtenon MMC by irrigation seems to provide improved short-term outcomes compared with application with sponges. With a similar safety profile, the irrigation method provides better IOP control, and decreases the need for further clinical/surgical intervention in the short-term after trabeculectomy. Longer-term studies will be useful in analyzing if these differences persist with time.


Assuntos
Alquilantes/administração & dosagem , Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Mitomicina/administração & dosagem , Implantação de Prótese , Cápsula de Tenon/efeitos dos fármacos , Trabeculectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Tampões de Gaze Cirúrgicos , Irrigação Terapêutica , Tonometria Ocular , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA