Materials (Basel) ; 17(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38612139

RESUMO

Grit basting is the most common process applied to titanium dental implants to give them a roughness that favors bone colonization. There are numerous studies on the influence of roughness on osseointegration, but the influence of the compressive residual stress associated with this treatment on biological behavior has not been determined. For this purpose, four types of surfaces have been studied using 60 titanium discs: smooth, smooth with residual stress, rough without stress, and rough with residual stress. Roughness was studied by optic interferometry; wettability and surface energy (polar and dispersive components) by contact angle equipment using three solvents; and residual stresses by Bragg-Bentano X-ray diffraction. The adhesion and alkaline phosphatase (ALP) levels on the different surfaces were studied using Saos-2 osteoblastic cultures. The bacterial strains Streptococcus sanguinis and Lactobacillus salivarius were cultured on different surfaces, determining the adhesion. The results showed that residual stresses lead to increased hydrophilicity on the surfaces, as well as an increase in surface energy, especially on the polar component. From the culture results, higher adhesion and higher ALP levels were observed in the discs with residual stresses when compared between smooth and roughened discs. It was also found that roughness was the property that mostly influenced osteoblasts' response. Bacteria colonize rough surfaces better than smooth surfaces, but no changes are observed due to residual surface tension.

2.
Materials (Basel) ; 17(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38255602

RESUMO

STATEMENT OF PROBLEM: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. OBJECTIVE: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. MATERIALS AND METHODS: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N × 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. RESULTS: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. CONCLUSIONS: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.

3.
J Clin Med ; 12(13)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37445228

RESUMO

In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 µm at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 µm do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.

4.
J Clin Med ; 12(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36769501

RESUMO

The major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads are applied. In this work, torque differences in the tightening and loosening of the connection screws after 1 cycle, 10 cycles and 1000 cycles for 4 dental implants with 2 external and 2 internal connections were analyzed. The loosening of 240 implants (60 for each system) was determined using high-precision torsimeters and an electromechanical testing machine. A total of 60 dental implants for each of the 4 systems were inserted into fresh bovine bone to determine the micromovements. The implant stability values (ISQ) were determined by RFA. The mechanical loads were performed at 30° from 20 N to 200 N. By means of the Q-star technique, the micromovements were determined. It was observed that, for a few cycles, the loosening of the screw did not exceed a loss of tightening of 10% for both connections. However, for 1000 cycles, the loss for the external connection was around 20% and for the internal connection it was 13%. The micromovements showed a lineal increase with the applied load for the implant systems studied. An external connection presented greater micromotions for each level of applied load and lower ISQ values than internal ones. An excellent lineal correlation between the ISQ and micromobility was observed. These results may be very useful for clinicians in the selection of the type of dental implant, depending on the masticatory load of the patient as well as the consequences of the insertion torque of the dental implant and its revisions.

5.
J Clin Med ; 12(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36769794

RESUMO

Gingivitis and periodontitis are chronic inflammatory diseases that affect the supporting tissues of the teeth. Although induced by the presence of bacterial biofilms, other factor, such as tobacco smoking, drugs, and various systemic diseases, are known to influence their pathogenesis. Diabetes mellitus and periodontal diseases correspond to inflammatory diseases that have pathogenic mechanisms in common, with the involvement of pro-inflammatory mediators. A bidirectional relationship between type 2 diabetes and periodontitis has been documented in several studies. Significantly less studies have focused on the association between periodontal disease and type 1 diabetes. The aim of the study is to analyze the association between periodontal status and type 1 diabetes mellitus. The "Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines" was used and registered at PROSPERO. The search strategy included electronic databases from 2012 to 2021 and was performed by two independent reviewers. According to our results, we found one article about the risk of periodontal diseases in type 1 diabetes mellitus subjects; four about glycemic control; two about oral hygiene; and eight about pro-inflammatory cytokines. Most of the studies confirm the association between type 1 diabetes mellitus and periodontal diseases. The prevalence and severity of PD was higher in DM1 patients when compared to healthy subjects.

6.
Materials (Basel) ; 15(10)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35629663

RESUMO

Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 µm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 µm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m2/g) corresponds to the particles larger than 30 µm being higher than 0.4969 and 0.4802 m2/g of those that are 5 and 15 µm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, -395 MPa for the 5 µm particles, and -369 for the 15 µm particles, and the lowest residual stresses were found for the 30 µm particles with values of -267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 µm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts.

7.
Artigo em Inglês | MEDLINE | ID: mdl-35409826

RESUMO

Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-implantitis following the criteria of Renvert et al. 2018. Results: In total, 21 patients (15.9%) suffered peri-implantitis (PPG) and 111 patients (84.1%) did not suffer peri-implantitis (NPG). The results reveal that smokers have a high incidence of peri-implantitis (72.7%) compared to non-smokers (27.3%) (p < 0.0005). Another variable with significant results (p < 0.01) was periodontitis: 50% PPG and 23.9% NPG suffered advanced periodontitis. Systemic diseases such as arterial hypertension, diabetes mellitus, osteoporosis, and cardiovascular diseases do not show a statistically significant influence on the incidence of peri-implantitis. Patients who did not attend their maintenance therapy appointment had an incidence of peri-implantitis of 61.4%, compared to 27.3% in those who attend (p < 0.0001). From the results obtained, we can conclude that relevant factors affect peri-implantitis, such as tobacco habits, moderate and severe periodontitis, and attendance in maintenance therapy.


Assuntos
Peri-Implantite , Periodontite , Humanos , Incidência , Estudos Longitudinais , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Periodontite/complicações , Periodontite/epidemiologia , Estudos Retrospectivos , Fatores de Risco
8.
J Clin Med ; 11(4)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35207298

RESUMO

The purpose of this research is to study the biomechanical response of dental implants in bone-level type locations, 0.5 mm above and below the bone level. In addition, the influence of the thickness of the cortical bone on osseointegration is determined due to the mechanical loads transfer from the dental implant to the cortical and trabecular bone. The thicknesses studied were 1.5 mm and 2.5 mm. Numerical simulations were performed using a finite element method (FEM)-based model. In order to verify the FEM model, the in silico results were compared with the results obtained from a histological analysis performed in an in vivo study with 30 New Zealand rabbits. FEM was performed using a computerized 3D model of bone-level dental implants inserted in the lower jawbone with an applied axial load of 100 N. The analysis was performed using different distances from the bone level and different thicknesses of cortical bone. The interface area of bone growth was evaluated by analyzing the bone-implant contact (BIC), region of interest (ROI) and total bone area (BAT) parameters obtained through an in vivo histological process and analyzed by scanning electron microscopy (SEM). Bone-level implants were inserted in the rabbit tibiae, with two implants placed per tibia. These parameters were evaluated after three or six weeks of implantation. FEM studies showed that placements 0.5 mm below the bone level presented lower values of stress distribution compared to the other studied placements. The lower levels of mechanical stress were then correlated with the in vivo studies, showing that this position presented the highest BIC value after three or six weeks of implantation. In this placement, vertical bone growth could be observed up the bone level. The smallest thickness of the study showed a better transfer of mechanical loads, which leads to a better osseointegration. In silico and in vivo results both concluded that the implants placed 0.5 mm below the cortical bone and with lower thicknesses presented the best biomechanical and histological behavior in terms of new bone formation, enhanced mechanical stability and optimum osseointegration.

9.
Materials (Basel) ; 15(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35207933

RESUMO

The stability and integrity of the abutment-implant connection, by means of a screw, is fallible from the moment the prosthetic elements are joined and is dependent on the applied preload, wear of the components and function. One of the main causes of screw loosening is the loss of preload. The loosening of the screw-abutment can cause complications such as screw fracture, marginal gap, peri-implantitis, bacterial microleakage, loosening of the crown and discomfort of the patient. It is also reported that loosening of the screw/abutment may lead to a failure of osseointegration. It is necessary to evaluate and quantify, with in vitro studies, the torque loss before and after loading in the different connections. Aim: evaluate the influence of implant- abutment connection design in torque maintenance after single tightening, multiple tightening and multiple tightening followed by mechanical cycling. Materials and Methods: 180 Klockner implants divided in 4 groups: 15 SK2 external connection, 25 Ncm tightening torque; 15 KL external connection, 30 Ncm tightening torque; 15 Vega internal connection, 25 Ncm tightening torque; 15 Essential internal connection, 30 Ncm tightening torque. In each group removal torque values (RTV) were evaluated with a digital torque meter, in 3 distinct phases: after one single tightening, 10 multiple tightenings and 10 multiple tightenings and cyclic loading (500 N × 1000 cycles). Results: After one single tightening, and for all connections, RTV were lower than those of insertion, but only for Essential and Vega internal connections this result was statistically significant. After multiple tightening, RTV were significantly lower in all connections. After repeated tightening followed by cyclic loading, mean RTV were significantly lower, when compared to insertion torque. The multiple tightening technique resulted in higher RTV than the single tightening technique, except for Vega implant. The multiple tightening followed by cyclic load, compared to the other phases, was the one that generated the lowest RTV, for all connections. Conclusions: The connection design, in our study, did not seem to influence the maintenance of preload. Loading influenced the loss of preload, in the sense that significantly decreased the removal torque values. The multiple re-tightening technique resulted in higher removal torque values than the single tightening technique. Clinically, our results recommend to retighten retaining screws, a few minutes after insertion.

10.
Materials (Basel) ; 15(4)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35208101

RESUMO

The procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol. Using X-ray diffraction, we determined the stresses accumulated in each of the as-received, machined and debris implants. The resistance to corrosion in open circuit and potentiodynamically in physiological medium has been determined, and the corrosion potentials and intensities have been determined. Tests have been carried out to determine ion release by ICP-MS at different immersion times. The results show that the corrosion resistance and the release of titanium ions into the medium are related to the accumulated energy or the degree of deformation. The titanium debris exhibit compressive residual stresses of -202 MPa, the implant treated with implantoplasty -120 MPa, and as-received -77 MPa, with their corrosion behavior resulting in corrosion rates of 0.501, 0.77, and 0.444 mm/year, respectively. Debris is the material with the worst corrosion resistance and the one that releases the most titanium ions to the physiological medium (15.3 ppb after 21 days vs. 7 ppb for as-received samples). Pitting has been observed on the surface of the debris released into the physiological environment. This behavior should be taken into account by clinicians for the good long-term behavior of implants with implantoplasty.

11.
Artigo em Inglês | MEDLINE | ID: mdl-34948515

RESUMO

BACKGROUND: The objective was to determine if asymmetric facial features, nasal and chin deviations, affect the perception of attractiveness of a dental midline angulation, and if it is consistent among both dentists and laypeople. It was also analyzed if factors, such as the sex, age group of the participants and the dentist's area of operation are relevant in their assessment. METHODS: A cross-sectional study, approved by the Ethics Committee of Fernando Pessoa University. From a symmetrical facial model (SFM) image, a natural-looking asymmetrical face was created. Based on this asymmetric facial model six images were created, with different directions and degrees of inclination of the dental midline. In total, 236 laypersons and 242 dentists completed the online questionnaire where they rated the self-perception of attractiveness of the eight images (VAS scale from 0 to 10). Non-parametric comparisons (IBM© SPSS Statistics vs. 27.0, p < 0.05). RESULTS: The results showed a significant difference in the perception of attractiveness between laypeople and dentists. This finding was consistent regarding every image, except for the SFM. The factors, sex of the people participating and dentist's area of operation, seemed only to contribute to a significant difference in the perception when it came to the SFM. The perceived attractiveness of the images, for dentists and laypersons, did not differ by age group of the participant, apart from images 6 and 8. CONCLUSIONS: Dentists are more rigorous about dental midline inclinations than laypersons. The perception of attractiveness was affected by the age group and sex of the participants and the dentist's area of operation.


Assuntos
Estética Dentária , Sorriso , Atitude do Pessoal de Saúde , Estudos Transversais , Odontólogos , Assimetria Facial , Humanos
12.
Artigo em Inglês | MEDLINE | ID: mdl-34832013

RESUMO

The present study had a convenience sample with 236 laypeople and 242 dentists who completed an online questionnaire to choose the most attractive image among six pairs for comparison. Control image: symmetric (parallelism between occlusal plane (OP), commissural line (CL), and interpupillary line (IL)). Change of Control, obtaining three images with a 3-degree inclination of the labial commissures. Image A: OP parallel to IL; Image B: OP parallel to CL; Image C: OP at 1.5 degree mean angulation between IL and CL. Non-parametric comparison (IBM© SPSS Statistics vs. 27.0, p < 0.05). The "Dentists" group's decreasing order of preference (attractiveness) of the images is: Control > A > C > B (p < 0.05). In the "Lay" group, it is: Control > A > (C not ≠ B). Dentists significantly prefer more the Control and Image A than laypeople (p < 0.001). Sex (single exception in laypeople), age, and dentist's area of activity did not interfere in the perception of attractiveness. Dentists and laypeople preferred the Control when compared to images with CL canted. In the existence of CL inclination, the preference of the groups was the IL as a reference for OP orientation, with the mean angulation or coincident with the CL being considered less aesthetic.


Assuntos
Oclusão Dentária , Estética Dentária , Odontólogos , Estética , Humanos , Inquéritos e Questionários
13.
Polymers (Basel) ; 13(13)2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34208978

RESUMO

The pursuit of less time-consuming procedures led to the development of high-power light-curing-units (LCU) to light-cure dental-resin-based-materials. This review aims to describe high-power light-emitting-diode (LED)-LCUs, by a bibliometric systematization of in vitro and in vivo studies. The research-question, by PICO model, aimed to assess the current knowledge on dentistry-based high-power LED-LCUs by analyzing to what extent their use can promote adverse events on materials and patients' oral condition when compared to low-power LED-LCUs, on daily dental practice. PubMed and B-on database search focused on high-power (≥2000 mW/cm2) LED-LCUs outputs. Studies assessing performance of high-power LED-LCUs for light-curing dental-resin-based-materials were included. From 1822 screened articles, 21 fulfilled the inclusion criteria. Thirty-two marketed units with high levels of radiant emittance (≥2000 mW/cm2 up to 6000 mW/cm2) were identified. Most output values vary on 2000-3000 mW/cm2. The highest output found was 6000 mW/cm2, in FlashMax™P3. Reports suggest that light-curing protocols with lower emittance irradiance and longer exposure outperforms all other combination, however in some clinical procedures high-power LED-LCUs are advocated when compared to low-power LED-LCUs. Moreover, long time exposures and over-curing can be dangerous to the biological vital pulp, and other oral tissues. Evidence showing that high-power LCUs are the best clinical option is still very scarce.

14.
Artigo em Inglês | MEDLINE | ID: mdl-33922745

RESUMO

In the treatment of gingival recession, different surgical options have been described: free gingival grafts (FGG), connective tissue Grafts (CTG), and a more recent technique, de-epithelialized free gingival graft (DFGG). They are not procedures exempt from the appearance of complications. Most publications refer to postoperative complications, and there is limited literature regarding the development of late complications (weeks or months). Our working group carried out a study to describe the development of late complications associated with the use of DFGG in comparison with CTG, providing an incidence rate and a classification. Sixty-eight patients with mucogingival problems were selected, and divided into two groups: the Test Group, for which we used DFGG + Coronal Advancement Flap (CAF), and the Control Group (CTG + CAF). All patients were treated at the University of Seville's dental school to solve mucogingival problems for aesthetic and/or functional reasons. A classification is proposed based on its severity; Major and Minor. Major complications included reepithelialization of the graft, epithelial bands, cul-de-sac, epithelial cysts, and bone exostoses. Minor complications included the graft´s color changes and superficial revascularization. Late major complications were only associated with the use of the DFGG, and the late minor complications developed with the use of the DFGG were much higher than those associated with CTG. CTG appears to be a safer procedure than DFGG in terms of late complications.


Assuntos
Gengiva , Retração Gengival , Tecido Conjuntivo , Seguimentos , Retração Gengival/cirurgia , Humanos , Raiz Dentária , Resultado do Tratamento
15.
Artigo em Inglês | MEDLINE | ID: mdl-33451161

RESUMO

PURPOSE: The aim of this retrospective study was to compare the influence of removing or not removing a prosthesis after regenerative surgery on peri-implant defects. METHODS: Two different groups were compared (Group 1: removing the prosthesis; Group 2: maintaining the prosthesis), analyzing radiographic bone filling (n = 32 implants) after regenerative treatment in periapical radiographs. The peri-implant defects were measured before and after regenerative treatment using Bio-Oss® (Geistlich Pharma, Wohhusen, Switzerland) and a reabsorbable collagen membrane (Jason®, Botis, Berlin, Germany), the healing period was two years after peri-implant regenerative surgery. Statistical analysis was performed, and a Chi square test was carried out. To determine the groups that made the difference, corrected standardized Haberman residuals were used, and previously a normality test had been applied; therefore, an ANOVA or Mann-Whitney U test was used for the crossover with the non-normal variables in Group 1 and Group 2. RESULTS: The results obtained suggest that a regenerative procedure with xenograft, resorbable membrane, and detoxifying the implant surface with hydrogen peroxide form a reliable technique to achieve medium-term results, obtaining an average bone gain at a radiographic level of 2.84 mm (±1.78 mm) in patients whose prosthesis was not removed after peri-implant bone regenerative therapy and 2.18 mm (±1.41 mm) in patients whose prosthesis was removed during the healing period. CONCLUSIONS: There are no statistically significant differences in the response to treatment when removing or keeping the prosthesis after regenerative surgery in peri-implant defects.


Assuntos
Próteses e Implantes , Berlim , Seguimentos , Alemanha , Humanos , Estudos Retrospectivos , Suíça , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-33498902

RESUMO

INTRODUCTION: Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. MATERIALS AND METHODS: A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. RESULTS: The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. CONCLUSIONS: The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs' design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols.


Assuntos
Desenho Assistido por Computador , Boca Edêntula , Técnica de Moldagem Odontológica , Odontologia , Humanos , Próteses e Implantes
17.
Artigo em Inglês | MEDLINE | ID: mdl-33513756

RESUMO

According to classic Hirschfeld studies, the first teeth to be lost are the first and second maxillary molars. After the teeth are extracted and the alveolar process is developed, the maxillary sinus is reabsorbed and pneumatized with a decrease in bone availability in the posterior sector of the maxilla. This process often creates the need to perform regeneration techniques for the placement of implants in this area due to the low availability of bone. The most frequently used and documented technique for the elevation of the sinus maxillary floor is elevation by the side window, as proposed by Tatum. In 1994, Summers proposed a technique that allowed the elevation of the sinus floor from a crestal access using an instrument called an osteotome, as well as the placement of the implant in the same surgical act. The aimed of the study was to evaluate the survival of 32 implants placed in posterior maxilla with bone availability less than 5 mm performing a sinus lift augmentation technique with osteotome without biomaterials. The results of this study show a survival rate of 100% for 32 implants placed in situations with an initial bone availability of 2 to 5 mm without the use of graft material. The infra-drilling technique used offers an increase in the primary stability of implants that allows adequate osteointegration Implants placed were charged at 12 weeks. In all cases, spontaneous bone formation was observed, even in cases where a positive Valsalva maneuver was observed. This proposed technique reduces treatment time and the need for more invasive maxillary sinus augmentation techniques.


Assuntos
Levantamento do Assoalho do Seio Maxilar , Materiais Biocompatíveis , Maxila/cirurgia , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Osteotomia
18.
Artigo em Inglês | MEDLINE | ID: mdl-33348644

RESUMO

Aim: (PRIMARY) Assess the changes in bone level (6 and 12 months after implant placement) between the test (definitive abutment (DEF)) and control (healing abutment (HEA)) groups. (SECONDARY) Assess the changes in bone level (6 and 12 months after implant placement) between the 1 mm high abutment group and 2 mm abutment group. Evaluate changes in implant stability recorded with analysis of the resonance frequency (RFA) Osstell system, at 6 and 12 months after implant placement, between the control group (HEA) and test (DEF). For the DEF group, the abutment was placed at the time of the surgery and was never removed. For the HEA group, the abutment was removed three times during the manufacture of the crowns. The abutments used were 1 mm high (Subgroup A) and 2 mm high (Subgroup B). Materials and methods: A total of 147 patients were selected between 54.82 ± 11.92 years old. After implant placement, patients were randomly distributed in the DEF and HEA group. After the implant placement, a periapical radiograph was taken to assess the peri-implant bone level; the same procedure was carried out 6 and 12 months post-placement. To compare the qualitative variables between the groups (HEA/DEF), the Chi-square test was used; for quantitative (MANOVA). Results: After a year, the accumulated bone loss was 0.48 ± 0.71 mm for the HEA group and 0.36 ± 0.79 mm for the DEF group, without statistical significance. Differences were only found due to timing (time) between 0 and 6 months (=0.001) and 0 and 12 months (0.001), with no differences attributable to the study groups (DEF and HEA). The accumulated bone loss (1 year) was 0.45 ± 0.78 mm for the 1 mm abutment group and 0.41 ± 0.70 mm for the 2 mm abutment group (p = 0.02). No differences were observed in implant stability between groups. Conclusions: The "One Abutment-One Time" concept does not reduce peri-implant bone loss compared to the connection-disconnection technique. The height of the abutment does influence bone loss: the higher the abutment, the lower the bone loss.


Assuntos
Perda do Osso Alveolar/diagnóstico , Dente Suporte , Implantes Dentários para Um Único Dente , Adulto , Idoso , Projeto do Implante Dentário-Pivô , Implantação Dentária Endóssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-33276529

RESUMO

As immediate loading protocols are becoming more frequent, the primary stability of implants has become an essential criterion for the osseointegration of dental implants. Based on this, the objective of this study was to understand the influence of different undersized surgical preparation sites on the insertion torque (IT) and implant stability quotient (ISQ). Four different site-preparation protocols were performed on fresh humid type III bovine bone: one control, the standard protocol recommended by the manufacturer (P1), and three variations of undersized techniques (P2, P3 and P4). The implant used was VEGA by Klockner Implant System. The sample size was n = 40 for each of the four groups. A torquemeter was used to measure the IT, and the ISQ was measured with a Penguin RFA. Both variables showed a tendency to increase as the preparation technique was reduced, although not all the values were statistically significant (p < 0.05) when comparing with the standard preparation. The preparations without a cortical drill, P2 and P4, showed better results than those with a cortical drill. Given the limitations of this study, it can be concluded that reducing the implant preparation can increase both the IT and ISQ. Removing the cortical drill is an effective method for increasing implant stability, although it should be used carefully.


Assuntos
Próteses e Implantes , Animais , Bovinos , Objetivos , Padrões de Referência , Projetos de Pesquisa , Tamanho da Amostra , Torque
20.
Artigo em Inglês | MEDLINE | ID: mdl-32947802

RESUMO

Resonance frequency analysis (RFA) requires abutment disconnection to monitor implant stability. To overcome this limitation, an experimental transepithelial abutment was designed to allow a SmartPeg to be screwed onto it, in order to determine the prototype abutments repeatability and reproducibility using Osstell ISQ and to assess whether implant length and diameter have an influence on the reliability of these measurements. RFA was conducted with a SmartPeg screwed directly into the implant and onto experimental abutments of different heights of 2, 3.5 and 5 mm. A total of 32 patients (116 implants) were tested. RFA measurements were taken twice for each group from mesial, distal, buccal and palatal/lingual surfaces. Mean values and SD were calculated and Intraclass Correlation Coefficients (ICC) (p < 0.05, IC 95%). The implant stability quotient (ISQ) mean values were 72.581 measured directly to implant and 72.899 (2 mm), 72.391 (3.5 mm) and 71.458 (5 mm) measured from the prototypes. ICC between measurements made directly to implant and through 2-, 3.5- and 5-mm abutments were 0.908, 0.919 and 0.939, respectively. RFA values registered through the experimental transepithelial abutments achieved a high reliability. Neither the implant length nor the diameter had any influence on the measurements' reliability.


Assuntos
Próteses e Implantes , Análise de Frequência de Ressonância , Vibração , Epitélio , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA