Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Hear Res ; 419: 108318, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34334219

RESUMO

In bone conduction (BC) stimulation, the sound travels from the site of stimulation to the ipsilateral and contralateral cochlea. A frequency dependent reduction in BC hearing sensitivity occurs when sound travels to the contralateral cochlea as compared to the ipsilateral cochlea. This effect is called transcranial attenuation (TA) that is affected by several factors. Experimental and clinical studies describe TA and the factors that have an effect on it. These factors include stimulus location, coupling of a bone conduction hearing aid to the underlying tissue, and the properties of the head (such as geometry of the head, thickness of the skin and/or skull, changes due to aging, iatrogenic changes such as bone removal in mastoidectomy, and occlusion of the external auditory canal). While TA has an effect of the patient's benefit of BCHAs, there seems to be a discrepancy between experimental measurements and clinical relevance. The effects are small and the interindividual variability, in comparison, is rather large. However, a better understanding of these factors may help to determine the site of attachment, the coupling mode, and possibly the fitting of a BCHA, depending on its indication.


Assuntos
Condução Óssea , Auxiliares de Audição , Estimulação Acústica , Condução Óssea/fisiologia , Cóclea/fisiologia , Humanos , Mastoidectomia , Som , Vibração
2.
J Laryngol Otol ; 134(5): 409-414, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32425144

RESUMO

OBJECTIVE: To investigate the prevalence of bony dehiscence in the tympanic facial canal in patients with acute otitis media with facial paresis compared to those without facial paresis. METHOD: A retrospective case-control study was conducted on acute otitis media patients with facial paresis undergoing high-resolution temporal bone computed tomography. RESULTS: Forty-eight patients were included (24 per group). Definitive determination of the presence of a bony dehiscence was possible in 44 out of 48 patients (91.7 per cent). Prevalence of bony dehiscence in acute otitis media patients with facial paresis was not different from that in acute otitis media patients without facial paresis (p = 0.21). Presence of a bony dehiscence was associated with a positive predictive value of 66.7 per cent in regard to development of facial paresis. However, an intact bony tympanic facial canal did not prevent facial paresis in 44.8 per cent of cases (95 per cent confidence interval = 34.6-55.6). CONCLUSION: Prevalence of bony dehiscence in acute otitis media patients with facial paresis did not differ from that in acute otitis media patients without facial paresis. An intact tympanic bony facial canal does not protect from facial paresis development.


Assuntos
Orelha Média , Paralisia Facial/etiologia , Otite Média/complicações , Doença Aguda , Adulto , Estudos de Casos e Controles , Paralisia Facial/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Otite Média/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
Hear Res ; 378: 149-156, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30661818

RESUMO

In incus stapedotomy surgeries, the longitudinal direction of the piston prosthesis should ideally be perpendicular to the stapes footplate. However, in reality, some amounts of angular deviation of the prosthesis from the ideal angular position is unavoidable due to anatomical constraints and surgical conditions. This study aims to evaluate the influence of angular positioning of the prosthesis on surgical outcomes in incus stapedotomy and to provide surgical guidelines related to practical tolerance of the angular positioning. In this study, this influence was assessed with a Kurz NiTiBond prosthesis (0.4-mm diameter) and fenestra sizes of 0.5- and 0.6-mm diameter in cadaveric temporal bones (n = 7 including 2 preliminary tests). Angular position of the prosthesis relative to the footplate was modulated by rotating the stapes about the long and short axes of the footplate. At each angular position, the tympanic membrane was acoustically stimulated in the frequency range of 0.2-10 kHz, and motion of the prosthesis was measured using a Laser Doppler vibrometer (LDV). Furthermore, micro-computed tomography (micro-CT) data of the middle-ear ossicles were used for anatomical analysis of angular positioning of the prosthesis. The results showed that changes of angular position of the prosthesis relative to the stapes footplate do not cause significant changes of prosthesis motion until a certain angular position threshold, and sharply attenuate prosthesis motion when the angular position reaches the threshold. The threshold of the angular position, as the tilting angle of the prosthesis from the direction normal to the stapes footplate, was 26.9 ±â€¯2.5° with the fenestration hole of 0.5-mm diameter and 30.6 ±â€¯3.0° with the fenestration hole of 0.6-mm diameter (n = 5, p < 0.01 for difference between the two fenestra sizes). Analysis of the middle-ear anatomy in this study revealed that the tolerances of the angular positions of the prosthesis does not always cover possible positions of prosthesis crimping. This study suggests that if an anterior offset of the stapes head and/or the thickened footplate is suspected, efforts to locate prosthesis crimping closer to the tip of the incus and/or to make a sufficiently large fenestration hole are favorable.


Assuntos
Otosclerose/cirurgia , Implantação de Prótese/instrumentação , Cirurgia do Estribo/instrumentação , Estribo , Osso Temporal/cirurgia , Cadáver , Humanos , Fluxometria por Laser-Doppler , Movimento , Otosclerose/diagnóstico por imagem , Otosclerose/fisiopatologia , Desenho de Prótese , Estribo/diagnóstico por imagem , Estribo/fisiopatologia , Osso Temporal/diagnóstico por imagem , Osso Temporal/fisiopatologia , Microtomografia por Raio-X
4.
Hear Res ; 340: 153-160, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26807795

RESUMO

Bone conduction (BC) stimulation can be applied by vibration to the bony or skin covered skull (osseous BC), or on soft tissue such as the neck (non-osseous BC). The interaction between osseous and non-osseous bone conduction pathways is assessed in this study. The relation between bone vibrations measured at the cochlear promontory and the intracranial sound pressure for stimulation directly on the dura and for stimulation at the mastoid between 0.2 and 10 kHz was compared. First, for stimulation on the dura, varying the static coupling force of the BC transducer on the dura had only a small effect on promontory vibration. Second, the presence or absence of intracranial fluid did not affect promontory vibration for stimulation on the dura. Third, stimulation on the mastoid elicited both promontory vibration and intracranial sound pressure. Stimulation on the dura caused intracranial sound pressure to a similar extent above 0.5 kHz compared to stimulation on the mastoid, while promontory vibration was less by 20-40 dB. From these findings, we conclude that intracranial sound pressure (non-osseous BC) only marginally affects bone vibrations measured on the promontory (osseous BC), whereas skull vibrations affect intracranial sound pressure.


Assuntos
Limiar Auditivo/fisiologia , Condução Óssea/fisiologia , Cóclea/fisiologia , Som , Estimulação Acústica , Cadáver , Cabeça , Humanos , Processo Mastoide/fisiologia , Movimento (Física) , Pressão , Razão Sinal-Ruído , Crânio/fisiologia , Vibração
5.
Hear Res ; 340: 69-78, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26619749

RESUMO

Under large quasi-static loads, the incudo-malleolar joint (IMJ), connecting the malleus and the incus, is highly mobile. It can be classified as a mechanical filter decoupling large quasi-static motions while transferring small dynamic excitations. This is presumed to be due to the complex geometry of the joint inducing a spatial decoupling between the malleus and incus under large quasi-static loads. Spatial Laser Doppler Vibrometer (LDV) displacement measurements on isolated malleus-incus-complexes (MICs) were performed. With the malleus firmly attached to a probe holder, the incus was excited by applying quasi-static forces at different points. For each force application point the resulting displacement was measured subsequently at different points on the incus. The location of the force application point and the LDV measurement points were calculated in a post-processing step combining the position of the LDV points with geometric data of the MIC. The rigid body motion of the incus was then calculated from the multiple displacement measurements for each force application point. The contact regions of the articular surfaces for different load configurations were calculated by applying the reconstructed motion to the geometry model of the MIC and calculate the minimal distance of the articular surfaces. The reconstructed motion has a complex spatial characteristic and varies for different force application points. The motion changed with increasing load caused by the kinematic guidance of the articular surfaces of the joint. The IMJ permits a relative large rotation around the anterior-posterior axis through the joint when a force is applied at the lenticularis in lateral direction before impeding the motion. This is part of the decoupling of the malleus motion from the incus motion in case of large quasi-static loads.


Assuntos
Bigorna/fisiologia , Martelo/fisiologia , Osso Temporal/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Elasticidade , Humanos , Pessoa de Meia-Idade , Movimento (Física) , Estresse Mecânico , Vibração , Viscosidade , Microtomografia por Raio-X
6.
Laryngorhinootologie ; 93(3): 178-85, 2014 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-24135825

RESUMO

BACKGROUND: Compared to traditional stapes prostheses, self-crimping prostheses have been shown to result in similar, if not better, closure of the air bone gap in patients undergoing stapedotomy for otosclerosis. To achieve self-crimping, nitinol, a shape memory alloy, has been used for several years but concerns have been raised regarding possible damage to the incus and its muco-periosteum. We investigate these concerns with regard to the newer NiTiBOND stapes prosthesis in an observational multi-centre study. MATERIAL AND METHODS: In a multicentre, prospective observational study, 76 patients undergoing stapedotomy with the NiTiBond prosthesis across 4 centres were compared to 75 -retrospectively selected control SMart patients. Complications, intra-operative user-friendliness and audiological results at 3 months were documented. RESULTS: Audiological improvement and the rate of complications were similar in both groups. Non inferiority was shown at all frequencies and in the pure-tone average. The NiTiBOND prosthesis was described as very user-friendly. CONCLUSIONS: By eliminating manual crimping, stapedotomy using the NiTiBOND prosthesis can be facilitated and standardized. Furthermore, intraoperative handling characteristics of the prosthesis are very good which may further reduce operative risk. Importantly, we show that these benefits are not to the detriment of audiological outcome. Larger and longer-term studies are required to further evaluate results.


Assuntos
Ligas , Audiometria de Tons Puros , Prótese Ossicular , Otosclerose/cirurgia , Desenho de Prótese , Titânio , Adolescente , Adulto , Idoso , Limiar Auditivo , Condução Óssea , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
7.
Hear Res ; 301: 93-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23467173

RESUMO

OBJECTIVES: To assess the functional performance of the Bonebridge (BB, MED-EL), a newly-designed transcutaneous bone conduction implant that allows the skin to remain intact and to compare it with the current clinical model of choice, a percutaneous bone conduction implant (BAHA BP100, Cochlear Bone Anchored Solutions AG). MATERIALS AND METHODS: The devices were compared using two methods: (1) Measurements of cochlear promontory acceleration in five cadaver heads: Accelerations of the cochlear promontories on both ipsilateral and contralateral sides were measured using a Laser Doppler system, with free-field sound stimuli of 90 dB SPL in the frequency range of 0.3-10 kHz (2) Measurements of pure-tone sound field thresholds in 5 normally hearing human adult subjects under a condition of simulated hearing loss. For the latter measurements, the devices were applied to the head using a Softband, and measurements were performed in the frequency range of 0.25-8 kHz. Within investigation comparisons (i.e., in cadavers or listeners) and a cross-comparison analysis of the cadaver and human results were done. RESULTS: Results from the cadaver heads showed that the cochlear promontory acceleration with the BB was higher within 10 dB on the ipsilateral side and lower within 5 dB on the contralateral side than the acceleration with the BAHA, in the frequency range of 0.7-10 kHz. The transcranial attenuation of the acceleration for the BB was greater than for the BAHA within 20 dB. For the sound-field threshold assessments with human subjects, the BB and BAHA showed similar threshold improvements of more than 10 dB HL for the ipsilateral side. For the contralateral side, the threshold improvement with the BB was less than with the BAHA, indicating better separation between ipsilateral and contralateral sides. CONCLUSIONS: Preclinical results imply that the BB has functional performance similar to the BAHA and could be beneficial to patients suffering with conductive and mixed hearing losses as well as for those with unilateral impairment. Based on these preliminary results, a carefully designed clinical trial with conservative inclusion criteria can be recommended. This article is part of a special issue entitled "MEMRO 2012".


Assuntos
Condução Óssea , Implantes Cocleares , Auxiliares de Audição , Audição , Âncoras de Sutura , Adulto , Limiar Auditivo , Cadáver , Cóclea/anatomia & histologia , Feminino , Perda Auditiva , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Perda Auditiva Neurossensorial/reabilitação , Testes Auditivos , Humanos , Lasers , Masculino , Desenho de Prótese , Percepção da Fala , Transdutores
8.
Audiol Neurootol ; 16(1): 12-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20453499

RESUMO

Vibratory auditory stimulation or bone conduction (BC) reaches the inner ear through both osseous and non-osseous structures of the head, but the contribution of the different pathways of BC is still unclear. In this study, BC thresholds in response to stimulation at several different locations including the eye were assessed, while the magnitudes of skull bone vibrations were measured on the front teeth in human subjects with either normal hearing on both sides or unilateral deafness with normal hearing on the other side. The BC thresholds with stimulation at the ipsilateral mastoid and ipsilateral temporal region were lower than the BC thresholds with stimulation at the other sites, as reported by previous works. The lower thresholds with stimulation at the ipsilateral mastoid and ipsilateral temporal region matched higher amplitudes of skull bone vibrations measured on the teeth, but only at frequencies below 1 kHz. With stimulation at the eye, the thresholds were significantly higher than those with stimulation at the bony sites in the frequency range of 0.25-4 kHz. While skull bone vibrations as measured on the teeth during stimulation at the eye were low for low frequencies, significant bone vibrations were measured at 3 and 4 kHz, indicating different pathways for BC for either the soft tissue or bony site stimulation. This finding contradicts a straightforward relationship between vibrations of the skull bones and BC hearing thresholds.


Assuntos
Limiar Auditivo/fisiologia , Condução Óssea/fisiologia , Crânio/fisiologia , Dente/fisiologia , Vibração , Adulto , Análise de Variância , Audiometria de Tons Puros , Feminino , Humanos , Masculino , Estimulação Física
9.
Laryngorhinootologie ; 88(7): 460-4, 2009 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-19177327

RESUMO

BACKGROUND: The standard surgical approach to treat primary (pHPT) and secondary hyperparathyroidism (sHPT) used to be a cervicotomy with exploration of all four parathyroid glands. This access has been challenged recently by the introduction of minimally invasive techniques in order to achieve superior cosmesic results and to reduce theatre time. We analyzed the advantages and morbidities of these surgical aproaches. PATIENTS AND METHODS: Between 1997 and 2006 a total of 123 patients (109 with pHPT and 14 with sHPT) underwent parathyroidectomy at the ENT Department in Luzern. Ultrasonographic scanning was performed on 74 patients (68%), szintigraphy in 8 patients (7%) and both scanning methods in 27 patients (25%). 103 patients were available for follow-up. The indications for each technique were reviewed and outcome measures included serum Calcium and parathyroid hormone levels. RESULTS: Sensitivity for preoperative ultrasonographic and scintigraphic scanning was 67% and 65% for identification of the correct quadrant and 74% and 71% for identification of the correct side. A bilateral exploration was performed until June 2001 for all patients. Thereafter, a minimally invasive approach was chosen for patients with pHPT, whereas patients with sHPT still require bilateral exploration. Adequate preoperative localization was a prerequisite for a minimally invasive technique. Mean postoperative serum Kalzium levels were within the normal range, independently of the surgical technique and disease. Two patients developed hypercalcemia after an initially successful operation. CONCLUSIONS: Review of the literature confirms the shift from bilateral exploration towards minimally invasive techniques. The incidence of persistent or recurrent disease as well as the rate of complications seems comparable. Operation time for minimally invasive techniques is reduced in the hands of an experienced surgeon. However, proper preoperative localization of the diseased parathyroid gland is not always possible and the expenses of intraoperative parathyroid hormone measures do not lower the overall costs. Considerable experience and a multidisiplinary approach (endocrinologist, surgeon, pathologist) is required to adopt efficient minimally invasive techniques. As for sHPT, bilateral exploration remains the treatment of choice.


Assuntos
Adenoma/cirurgia , Coristoma/cirurgia , Hiperparatireoidismo Primário/cirurgia , Hiperparatireoidismo Secundário/cirurgia , Mediastino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Pescoço , Neoplasias Primárias Múltiplas/cirurgia , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia/métodos , Adenoma/sangue , Adenoma/diagnóstico , Cálcio/sangue , Coristoma/sangue , Coristoma/diagnóstico , Seguimentos , Humanos , Hiperparatireoidismo Primário/sangue , Hiperparatireoidismo Primário/diagnóstico , Hiperparatireoidismo Secundário/sangue , Hiperparatireoidismo Secundário/diagnóstico , Mediastino/cirurgia , Pescoço/cirurgia , Neoplasias Primárias Múltiplas/sangue , Neoplasias Primárias Múltiplas/diagnóstico , Hormônio Paratireóideo/sangue , Neoplasias das Paratireoides/sangue , Neoplasias das Paratireoides/diagnóstico , Complicações Pós-Operatórias/sangue , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi , Ultrassonografia
10.
HNO ; 56(9): 895-900, 2008 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-18330533

RESUMO

BACKGROUND: Stapedectomy and, more recently, stapedotomy have been widely accepted as the primary surgical techniques to improve conductive hearing in patients suffering from otosclerosis. Unsuccessful outcomes are infrequent, but revision surgery may become necessary. We have analyzed the value of computed tomography (CT) scanning following unsuccessful stapes surgery. PATIENTS AND METHODS: In a total of 37 CT scans, the depth of insertion, angle between prosthesis and footplate, location of prosthesis within the oval niche, visibility of the prosthesis, dehiscence of the superior semicircular canal, and extent of otospongiotic foci were evaluated and compared with the audiometric results. RESULTS: There was no significant correlation between CT parameters and audiologic results, except for patients with cochlear otosclerosis or lateral dislocation of the piston. One previously unknown dehiscence of the superior semicircular canal was diagnosed. Otospongiotic foci were seen in 13 ears (35%). CONCLUSION: Displacements of the stapes piston and rare causes for an insufficient result, such as a dehiscence of the superior semicircular canal, can be diagnosed accurately by CT. However, correlation between the audiologic results and the findings on CT scans was possible in only a few cases. Nevertheless, CT scans provide additional information for surgical planning in revision stapes surgery and may become increasingly important to reduce unanticipated intraoperative risks; they may even guide the surgeon not to perform unnecessary revision surgeries.


Assuntos
Perda Auditiva/diagnóstico por imagem , Perda Auditiva/prevenção & controle , Otosclerose/diagnóstico por imagem , Otosclerose/cirurgia , Cirurgia do Estribo/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA