Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Mater Chem B ; 12(18): 4489-4501, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38644661

RESUMO

Orthopedic device-related infection (ODRI) poses a significant threat to patients with titanium-based implants. The challenge lies in developing antibacterial surfaces that preserve the bulk mechanical properties of titanium implants while exhibiting characteristics similar to bone tissue. In response, we present a two-step approach: silver nanoparticle (AgNP) coating followed by selective laser-assisted surface alloying on commonly used titanium alumina vanadium (TiAl6V4) implant surfaces. This process imparts antibacterial properties without compromising the bulk mechanical characteristics of the titanium alloy. Systematic optimization of laser beam power (8-40 W) resulted in an optimized surface (32 W) with uniform TiAg alloy formation. This surface displayed a distinctive hierarchical mesoporous textured surface, featuring cauliflower-like nanostructures measuring between 5-10 nm uniformly covering spatial line periods of 25 µm while demonstrating homogenous elemental distribution of silver throughout the laser processed surface. The optimized laser processed surface exhibited prolonged superhydrophilicity (40 days) and antibacterial efficacy (12 days) against Staphylococcus aureus and Escherichia coli. Additionally, there was a significant twofold increase in bone mineralization compared to the pristine Ti6Al4V surface (p < 0.05). Rockwell hardness tests confirmed minimal (<1%) change in bulk mechanical properties compared to the pristine surface. This innovative laser-assisted approach, with its precisely tailored surface morphology, holds promise for providing enduring antibacterial and osteointegration properties, rendering it an optimal choice for modifying load-bearing implant devices without altering material bulk characteristics.


Assuntos
Ligas , Antibacterianos , Escherichia coli , Lasers , Próteses e Implantes , Prata , Staphylococcus aureus , Propriedades de Superfície , Titânio , Titânio/química , Titânio/farmacologia , Prata/química , Prata/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Staphylococcus aureus/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Ligas/química , Ligas/farmacologia , Animais , Testes de Sensibilidade Microbiana , Nanopartículas Metálicas/química , Calcificação Fisiológica/efeitos dos fármacos
2.
ACS Appl Bio Mater ; 7(3): 1526-1535, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38422985

RESUMO

Graphene quantum dots (GQDs), a class of fluorescent carbon materials, have displayed significant potential in various fields such as energy devices, catalysis, sensing, bioimaging, and drug delivery. Because of their extremely small size, generally less than 100 nm, they also have tremendous potential in plant science research, especially for the delivery of nucleic acids, breaking the barrier of cell walls. In this study, we synthesized GQDs with a size range of 2-5 nm, characterized them, and surface-functionalized them with branched polyethylenimine (bPEI). We then used the surface-functionalized GQDs as carriers to deliver double-stranded RNA (dsRNA) that target two growth-and-development-related genes in Fusarium graminearum─the causative organism of the Fusarium head blight disease of wheat. The successful binding of dsRNA to GQDs-bPEIs was demonstrated through gel-shifting assays, showcasing the potential for efficient dsRNA delivery. We designed dsRNAs targeting the MGV1 and RAS1 genes of F. graminearum by using the pssRNAit pipeline, ensuring high specificity and no off-target effects. The coding sequences of the designed dsRAS1 and dsMGV1 were cloned into the L4440 vector and transformed into the Escherichia coli HT115 strain for dsRNA production. Fungal culture analysis revealed that the inclusion of dsRNAs in potato dextrose agar (PDA) media effectively slowed down the growth. Exogenous spraying experiments both in plate cultures and in intact wheat spikes demonstrated that the dsRNA:GQDs-bPEIs treatment was more effective in restricting fungal mycelium growth or the number of infected spikelets compared to naked dsRNA treatment. Our study demonstrates the promising potential of graphene quantum dots as carriers for dsRNA-based fungal disease management in wheat and other crops.


Assuntos
Fusarium , Grafite , Pontos Quânticos , Triticum , RNA de Cadeia Dupla/genética , Escherichia coli
3.
IEEE Trans Biomed Eng ; PP2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38335074

RESUMO

A substantial number of critically ill patients in intensive care units (ICUs) rely on indwelling urinary catheters (IDCs), demanding regular monitoring of urine bags. This process increases the workload for healthcare providers and elevates the risk of exposure to contagious diseases. Moreover, IDCs are a primary cause of catheter-associated urinary tract infections (UTIs) in ICU patients whose delayed detection can have life-threatening complications. To address this, we have developed a Sticker Type Antenna for Remote Sensing (STARS) system capable of measuring urine flow rate and conductivity as early-risk markers for UTIs, alongside tracking patients' urine bag status to facilitate medical automation for healthcare providers. STARS comprises a simple, low-cost, disposable antenna module for contactless measurements of urine volume and conductivity, and a reusable wireless module for real-time data transmission. Systematic studies on STARS revealed its stable performance within physiologically relevant ranges of urine volume (0 to 2000 ml) and conductivity (5 to 40 mS/cm) in urine bags. As a proof-of-concept, STARS was tested in artificially created healthy and infected urine specimens to validate its non-contact sensing performance in detecting the onset of UTIs in catheterized patients within a hospital-like environment. STARS represents the first application of a real-time, contactless, wireless monitoring platform for simultaneous urine bag management and early risk detection of UTIs.

4.
IEEE Trans Biomed Eng ; PP2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38096093

RESUMO

Effective management of Inflammatory Bowel Disease (IBD) is contingent upon frequent monitoring of inflammation levels at targeted locations within the gastrointestinal (GI) tract. This is crucial for assessing disease progression and detecting potential relapses. To address this need, a novel single-use capsule technology has been devised that enables region-specific inflammation measurement, thereby facilitating repeatable monitoring within the GI tract. The capsule integrates a pH-responsive coating for location-specific activation, a chemiluminescent paper-based myeloperoxidase (MPO) sensor for inflammation detection, and a miniaturized photodetector, complemented by embedded electronics for real-time wireless data transmission. Demonstrating linear sensitivity within the physiological MPO concentration range, the sensor is capable of effectively identifying inflammation risk in the GI fluid. Luminescence emitted by the sensor, proportional to MPO concentration, is converted into an electrical signal by the photodetector, generating a quantifiable energy output with a sensitivity of 6.14 µJ/U.ml-1. The capsule was also tested with GI fluids collected from pig models simulating various inflammation states. Despite the physiological complexities, the capsule consistently activated in the intended region and accurately detected MPO levels with less than a 5% variation between readings in GI fluid and a PBS solution. This study heralds a significant step towards minimally invasive, in situ GI inflammation monitoring, potentially revolutionizing personalized IBD management and patient-specific therapeutic strategies.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37799507

RESUMO

Inflammatory bowel disease (IBD) has become alarmingly prevalent in the last two decades affecting 6.8 million people worldwide with a starkly high relapse rate of 40% within 1 year of remission. Existing visual endoscopy techniques rely on subjective assessment of images that are error-prone and insufficient indicators of early-stage IBD, rendering them unsuitable for frequent and quantitative monitoring of gastrointestinal health necessary for detecting regular relapses in IBD patients. To address these limitations, we have implemented a miniaturized smart capsule (2.2 cm × 11 mm) that allows monitoring reactive oxygen species (ROS) levels as a biomarker of inflammation for quantitative and frequent profiling of inflammatory lesions throughout the gastrointestinal tract. The capsule is composed of a pH and oxidation reduction potential (ORP) sensor to track the capsule's location and ROS levels throughout the gastrointestinal tract, respectively, and an optimized electronic interface for wireless sensing and data communication. The designed sensors provided a linear and stable performance within the physiologically relevant range of the GI tract (pH: 1-8 and ORP: -500 to +500 mV). Additionally, systematic design optimization of the wireless interface electronics offered an efficient sampling rate of 10 ms for long-running measurements up to 48 h for a complete evaluation of the entire gastrointestinal tract. As a proof-of-concept, the capsule the capsule's performance in detecting inflammation risks was validated by conducting tests on in vitro cell culture conditions, simulating healthy and inflamed gut-like environments. The capsule presented here achieves a new milestone in addressing the emerging need for smart ingestible electronics for better diagnosis and treatment of digestive diseases.

6.
Nanoscale ; 15(26): 11209-11221, 2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37345366

RESUMO

Surgical meshes composed of bioinert polymers such as polypropylene are widely used in millions of hernia repair procedures to prevent the recurrence of organ protrusion from the damaged abdominal wall. However, post-operative mesh infection remains a significant complication, elevating hernia recurrence risks from 3.6% to 10%, depending on the procedure type. While attempts have been made to mitigate these infection-related complications by using antibiotic coatings, the rise in antibiotic-resistant bacterial strains threatens their effectiveness. Bioactive glass-ceramics featuring noble metals, notably silver nanoparticles (AgNPs), have recently gained traction for their wide antibacterial properties and biocompatibility. Yet, conventional methods of synthesizing and coating of such materials often require high temperatures, thus making them impractical to be implemented on temperature-sensitive polymeric substrates. To circumvent this challenge, a unique approach has been explored to deposit these functional compounds onto temperature-sensitive polypropylene mesh (PP-M) surfaces. This approach is based on the recent advancements in cold atmospheric plasma (CAP) assisted deposition of SiO2 thin films and laser surface treatment (LST), enabling the selective heating and formation of functional glass-ceramic compounds under atmospheric conditions. A systematic study was conducted to identify optimal LST conditions that resulted in the effective formation of a bioactive glass-ceramic structure without significantly altering the chemical and mechanical properties of the underlying PP-M (less than 1% change compared to the original properties). The developed coating with optimized processing conditions demonstrated high biocompatibility and persistent antibacterial properties (>7 days) against both Gram-positive and Gram-negative bacteria. The developed process is expected to provide a new stepping stone towards depositing a wide range of functional bioceramic coatings onto different implant surfaces, thereby decreasing their risk of infection and associated complications.


Assuntos
Nanopartículas Metálicas , Telas Cirúrgicas , Prata/farmacologia , Prata/química , Dióxido de Silício/química , Antibacterianos/farmacologia , Antibacterianos/química , Polipropilenos , Bactérias Gram-Negativas , Bactérias Gram-Positivas , Cerâmica/química , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química
7.
Front Biosci (Elite Ed) ; 15(2): 9, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-37369568

RESUMO

Dermal wound infections are a rising source of morbidity and mortality in patients worldwide as new and worsening complications reduce the efficacy of traditional treatments. These challenges in wound care are increasingly caused by comorbidities such as obesity and diabetes as well as surging rates of antibiotic resistance. As a result, there is an urgent need for alternative treatment options. Gaseous ozone has shown great promise as a potential new treatment for infected dermal wounds. In this brief review of current wound therapy techniques found in the literature, an in-depth discussion of the mechanisms, benefits, and results of topical ozone gas as a therapy for infected dermal wounds is presented. This includes studies of ozone applied to wounds performed in vitro, in vivo, and clinical settings, as well as the use of ozone as an adjunct therapy for increasing the efficacy of traditional treatments. The overwhelming evidence suggests that ozone exhibits significant antimicrobial properties and has been shown to promote wound healing factors, especially when applied between 5-60 ppm. As such, this promising alternative therapy warrants a significant investment of time and resources to fully utilize ozone as an effective treatment against antibiotic resistant bacteria and other rising challenges in wound treatment.


Assuntos
Anti-Infecciosos , Ozônio , Infecção dos Ferimentos , Humanos , Ozônio/uso terapêutico , Infecção dos Ferimentos/tratamento farmacológico , Antibacterianos/uso terapêutico , Administração Tópica
8.
ACS Biomater Sci Eng ; 9(6): 3606-3617, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37235768

RESUMO

Wound infections with antibiotic-resistant bacteria, particularly the Gram-negative strains, pose a substantial health risk for patients with limited treatment options. Recently topical administration of gaseous ozone and its combination with antibiotics through portable systems has been demonstrated to be a promising approach to eradicate commonly found Gram-negative strains of bacteria in wound infections. However, despite the significant impact of ozone in treating the growing number of antibiotic-resistant infections, uncontrolled and high concentrations of ozone can cause damage to the surrounding tissue. Hence, before such treatments could advance into clinical usage, it is paramount to identify appropriate levels of topical ozone that are effective in treating bacterial infections and safe for use in topical administration. To address this concern, we have conducted a series of in vivo studies to evaluate the efficacy and safety of a portable and wearable adjunct ozone and antibiotic wound therapy system. The concurrent ozone and antibiotics are applied through a wound interfaced gas permeable dressing coated with water-soluble nanofibers containing vancomycin and linezolid (traditionally used to treat Gram-positive infections) and connected to a portable ozone delivery system. The bactericidal properties of the combination therapy were evaluated on an ex vivo wound model infected with Pseudomonas aeruginosa, a common Gram-negative strain of bacteria found in many skin infections with high resistance to a wide range of currently available antibiotics. The results indicated that the optimized combination delivery of ozone (4 mg h-1) and topical antibiotic (200 µg cm-2) provided complete bacteria eradication after 6 h of treatment while having minimum cytotoxicity to human fibroblast cells. Furthermore, in vivo local and systemic toxicity studies (e.g., skin monitoring, skin histopathology, and blood analysis) on pig models showed no signs of adverse effects of ozone and antibiotic combination therapy even after 5 days of continuous administration. The confirmed efficacy and biosafety profile of the adjunct ozone and antibiotic therapy places it as a strong candidate for treating wound infection with antimicrobial-resistant bacteria and further pursuing human clinical trials.


Assuntos
Antibacterianos , Infecção dos Ferimentos , Humanos , Animais , Suínos , Antibacterianos/efeitos adversos , Linezolida/farmacologia , Linezolida/uso terapêutico , Infecção dos Ferimentos/tratamento farmacológico , Infecção dos Ferimentos/microbiologia
9.
ACS Appl Mater Interfaces ; 15(13): 17078-17090, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-36961226

RESUMO

Conductive polymers and their composite materials have attracted considerable interest due to their potential applications in sensors, actuators, drug delivery systems, and energy storage devices. Despite their wide range of applications, many challenges remain primarily with respect to the complex synthesis and time-consuming manufacturing steps that are often required in the fabrication process of various devices with conductive polymers. Here, we demonstrate the novel use of cold atmospheric plasma (CAP)-assisted deposition technologies as a solvent-free and scalable approach for in situ polymerization and direct deposition of conductive polypyrrole-silver (PPy-Ag) nanocomposites onto the desired substrates under atmospheric conditions. In this study, a systematic approach with different precursor composition mixtures containing pyrrole as the monomer and AgNO3 as the photoinitiator was investigated to assess the effect of precursor composition on the final chemical, electrical, and mechanical properties of the PPy-Ag nanocomposite thin-film coatings which were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, and cyclic bending tests. The characterizations indicated the possibility of fabricating PPy-Ag nanocomposite films with tunable degrees of polymerization and Ag nanoparticle loading by simply varying the percentage of AgNO3 in precursor composition mixtures. Finally, as a proof of concept, the potential use of the PPy-Ag nanocomposite films with different Ag nanoparticle loading percentages was assessed for humidity sensing by measuring their level of change in electrical resistance in the relative humidity range of 12-60%. It is envisioned that the developed CAP-assisted deposition technology can provide a new stepping stone toward scalable additive manufacturing of various functional nanocomposite films for different low-cost and flexible electronic applications.

10.
ACS Biomater Sci Eng ; 9(3): 1620-1628, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36763005

RESUMO

Cellular tight junctions play a key role in establishing a barrier between different compartments of the body by regulating the selective passage of different solutes across epithelial and endothelial tissues. Over the past decade, significant efforts have been conducted to develop more clinically relevant "organ-on-a-chip" models with integrated trans-epithelial electrical resistance (TEER) monitoring systems to help better understand the fundamental underpinnings of epithelial tissue physiology upon exposure to different substances. However, most of these platforms require the use of high-cost and time-consuming photolithography processes, which limits their scalability and practical implementation in clinical research. To address this need, we have developed a low-cost microfluidic platform with an integrated electrode array that allows continuous real-time monitoring of TEER and the risk of bubble formation in the microfluidic system by using scalable manufacturing technologies such as screen printing and laser processing. The integrated printed electrode array exhibited excellent stability (with less than ∼0.02 Ω change in resistance) even after long-term exposure to a complex culture medium. As a proof of concept, the fully integrated platform was tested with HMT3522 S1 epithelial cells to evaluate the tight barrier junction formation through TEER measurement and validated with standard immunostaining procedures for Zonula occludens-1 protein. This platform could be regarded as a stepping stone for the fabrication of disposable and low-cost organ and tissue-on-a-chip models with integrated sensors to facilitate studying the dynamic response of epithelial tissues to different substances in more physiologically relevant conditions.


Assuntos
Células Epiteliais , Dispositivos Lab-On-A-Chip , Células Epiteliais/fisiologia , Linhagem Celular , Eletrodos , Impedância Elétrica
11.
Sci Rep ; 13(1): 3101, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36813820

RESUMO

For a continuous healthcare or environmental monitoring system, it is essential to reliably sense the analyte concentration reported by electrochemical sensors. However, environmental perturbation, sensor drift, and power-constraint make reliable sensing with wearable and implantable sensors difficult. While most studies focus on improving sensor stability and precision by increasing the system's complexity and cost, we aim to address this challenge using low-cost sensors. To obtain the desired accuracy from low-cost sensors, we borrow two fundamental concepts from communication theory and computer science. First, inspired by reliable data transmission over a noisy communication channel by incorporating redundancy, we propose to measure the same quantity (i.e., analyte concentration) with multiple sensors. Second, we estimate the true signal by aggregating the output of the sensors based on their credibility, a technique originally developed for "truth discovery" in social sensing applications. We use the Maximum Likelihood Estimation to estimate the true signal and the credibility index of the sensors over time. Using the estimated signal, we develop an on-the-fly drift-correction method to make unreliable sensors reliable by correcting any systematic drifts during operation. Our approach can determine solution pH within 0.09 pH for more than three months by detecting and correcting the gradual drift of pH sensors as a function of gamma-ray irradiation. In the field study, we validate our method by measuring nitrate levels in an agricultural field onsite over 22 days within 0.06 mM of a high-precision laboratory-based sensor. We theoretically demonstrate and numerically validate that our approach can estimate the true signal even when the majority (~ 80%) of the sensors are unreliable. Moreover, by restricting wireless transmission to high-credible sensors, we achieve near-perfect information transfer at a fraction of the energy cost. The high-precision sensing with low-cost sensors at reduced transmission cost will pave the way for pervasive in-field sensing with electrochemical sensors. The approach is general and can improve the accuracy of any field-deployed sensors undergoing drift and degradation during operation.

12.
ACS Sens ; 7(9): 2661-2670, 2022 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-36074898

RESUMO

Originally developed for use in controlled laboratory settings, potentiometric ion-selective electrode (ISE) sensors have recently been deployed for continuous, in situ measurement of analyte concentration in agricultural (e.g., nitrate), environmental (e.g., ocean acidification), industrial (e.g., wastewater), and health-care sectors (e.g., sweat sensors). However, due to uncontrolled temperature and lack of frequent calibration in these field applications, it has been difficult to achieve accuracy comparable to the laboratory setting. In this paper, we propose a novel temperature self-calibration method where the ISE sensors can serve as their own thermometer and therefore precisely measure the analyte concentration in the field condition by compensating for the temperature variations. We validate the method with controlled experiments using pH and nitrate ISEs, which use the Nernst principle for electrochemical sensing. We show that, using temperature self-calibration, pH and nitrate can be measured within 0.3% and 5% of the true concentration, respectively, under varying concentrations and temperature conditions. Moreover, we perform a field study to continuously monitor the nitrate concentration of an agricultural field over a period of 6 days. Our temperature self-calibration approach determines the nitrate concentration within 4% of the ground truth measured by laboratory-based high-precision nitrate sensors. Our approach is general and would allow battery-free temperature-corrected analyte measurement for all Nernst principle-based sensors being deployed as wearable or implantable sensors.


Assuntos
Eletrodos Seletivos de Íons , Nitratos , Calibragem , Concentração de Íons de Hidrogênio , Nitratos/análise , Água do Mar , Temperatura , Águas Residuárias
13.
Anal Chim Acta ; 1229: 340332, 2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36156230

RESUMO

Topical lidocaine patches are commonly used to relieve pain and suffering in various clinical and household settings. Despite its extensive use, excessive skin absorption during numbing or pain reduction procedures can cause systemic toxicity, which can lead to life-threatening conditions. Rapid and reliable monitoring of escalating levels of lidocaine in the blood could help management/prevention of lidocaine overdose and its associated complications. To address this need, here we have developed a disposable point-of-care (POC) diagnostic platform composed of an integrated graphene-based electrochemical sensor with paper-based microfluidics for rapid detection of lidocaine levels in serum and blood samples. The fabrication process takes advantage of advanced, scalable manufacturing techniques, including printing, laser processing, and nondestructive near infrared (NIR) drying. The sensitivity tests of the platform revealed a sensitivity of ∼0.2 µA µM-1 towards lidocaine concentrations in the clinically relevant range (1-100 µM) in both complex matrix fluids of serum and blood with high cross specificity in the presence of the interfering analytes. This proof-of-concept platform could be regarded as the first step toward the development of low-cost and translational POC devices that could help in better pain management and reduce potential side effects or misuse of analgesics.


Assuntos
Técnicas Biossensoriais , Grafite , Técnicas Eletroquímicas , Eletrodos , Humanos , Lidocaína , Microfluídica , Dor
14.
ACS Appl Mater Interfaces ; 14(40): 45752-45764, 2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36173396

RESUMO

Contamination of meat with pathogenic microorganisms can cause severe illnesses and food waste, which has significant negative impacts on both general health and the economy. In many cases, the expiration date is not a good indicator of meat freshness as there is a high risk of contamination during handling throughout the supply chain. Many biomarkers, including color, odor, pH, temperature, and volatile compounds, are used to determine spoilage. Among these, pH presents a simple and effective biomarker directly linked to the overgrowth of bacteria and degradation of the meat tissue. Low-cost methods for wireless pH monitoring are crucial in detecting spoilage on a large commercial scale. Existing technologies are often limited to short-range detection, with the use of batteries and different electronic components that increases both the manufacturing complexity and cost of the final device. To address these shortcomings, we have developed a cost-effective wireless pH sensor, which uses passive resonant frequency (RF) sensing, combined with a pH-responsive polymer that can be placed within packaged meat products and provide a remote assessment of the risk of microbial spoilage throughout the supply chain. The sensor tag consists of a sensing resonator coated with a pH-sensitive material and a passivated reference resonator operating in a differential frequency configuration. Upon exposure to elevated pH levels >6.8, the coating on the sensing resonator dissolves, which in turn results in a distinct change in the resonant frequency with respect to the reference resonator. Systematic theoretical and experimental results at different pH levels demonstrated that a 20% shift in resonant frequency demarcates the point for spoilage detection. As a proof of concept, the performance of the sensor in remotely detecting the risk of food spoilage was validated in packaged poultry over 10 days. The sensor fabrication process takes advantage of recent developments in the scalable manufacturing of flexible, low-cost devices, including selective laser etching of metalized plastic films and doctor-blade coating of stimuli-responsive polymer films. Furthermore, the biocompatibility of all the materials used in the sensor was confirmed with human intestinal cells (HCT-8 cells).


Assuntos
Produtos da Carne , Eliminação de Resíduos , Polímeros Responsivos a Estímulos , Humanos , Concentração de Íons de Hidrogênio , Plásticos , Polímeros/química
15.
Acta Biomater ; 154: 83-96, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36162763

RESUMO

The gastrointestinal (GI) tract, particularly the colon region, holds a highly diverse microbial community that plays an important role in the metabolism, physiology, nutrition, and immune function of the host body. Accumulating evidence has revealed that alteration in these microbial communities is the pivotal step in developing various metabolic diseases, including obesity, inflammatory bowel disease (IBD), and colorectal cancer. However, there is still a lack of clear understanding of the interrelationship between microbiota and diet as well as the effectiveness of chemoprevention strategies, including pre and probiotic agents in modifying the colonic microbiota and preventing digestive diseases. Existing methods for assessing these microbiota-diet interactions are often based on samples collected from the feces or endoscopy techniques which are incapable of providing information on spatial variations of the gut microbiota or are considered invasive procedures. To address this need, here we have developed an electronic-free smart capsule that enables site-specific sampling of the gut microbiome within the proximal colon region of the GI tract. The 3D printed device houses a superabsorbent hydrogel bonded onto a flexible polydimethylsiloxane (PDMS) disk that serves as a milieu to collect the fluid in the gut lumen and its microbiome by rapid swelling and providing the necessary mechanical actuation to close the capsule after the sampling is completed. The targeted colonic sampling is achieved by coating the sampling aperture on the capsule with a double-layer pH-sensitive enteric coating, which delays fluid in the lumen from entering the capsule until it reaches the proximal colon of the GI tract. To identify the appropriate pH-responsive double-layer coating and processing condition, a series of systematic dissolution characterizations in different pH conditions that mimicked the GI tract was conducted. The effective targeted microbial sampling performance and preservation of the smart capsule with the optimized design were validated using both realistic in vitro GI tract models with mixed bacteria cultures and in vivo with pigs as an animal model. The results from 16s rRNA and WideSeq analysis in both in vitro and in vivo studies showed that the bacterial population sampled within the retrieved capsule closely matched the bacterial population within the targeted sampling region (proximal colon). Herein, it is envisioned that such smart sampling capsule technology will provide new avenues for gastroenterological research and clinical applications, including diet-host-microbiome relationships, focused on human GI function and health. STATEMENT OF SIGNIFICANCE: The colonic microbiota plays a major role in the etiology of numerous diseases. Extensive efforts have been conducted to monitor the gut microbiome using sequencing technologies based on samples collected from feces or mucosal biopsies that are typically obtained by colonoscopy. Despite the simplicity of fecal sampling procedures, they are incapable of preserving spatial and temporal information about the bacteria through the gastrointestinal (GI) tract. In contrast, colonoscopy is an invasive and impractical approach to frequently assess the effect of dietary and therapeutic intake on the microbiome and their impact on the health of the patient. Here, we developed a non-invasive capsule that enables targeted sampling from the ascending colon, thereby providing crucial information for disease prediction and monitoring.


Assuntos
Microbioma Gastrointestinal , Microbiota , Humanos , Suínos , Animais , RNA Ribossômico 16S/genética , Microbioma Gastrointestinal/fisiologia , Colo , Fezes/microbiologia , Bactérias
16.
Sci Rep ; 12(1): 13927, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35977975

RESUMO

The problematic combination of a rising prevalence of skin and soft tissue infections and the growing rate of life-threatening antibiotic resistant infections presents an urgent, unmet need for the healthcare industry. These evolutionary resistances originate from mutations in the bacterial cell walls which prevent effective diffusion of antibiotics. Gram-negative bacteria are of special consideration due to the natural resistance to many common antibiotics due to the unique bilayer structure of the cell wall. The system developed here provides one solution to this problem through a wearable therapy that delivers and utilizes gaseous ozone as an adjunct therapy with topical antibiotics through a novel dressing with drug-eluting nanofibers (NFs). This technology drastically increases the sensitivity of Gram-negative bacteria to common antibiotics by using oxidative ozone to bypass resistances created by the bacterial cell wall. To enable simple and effective application of adjunct therapy, ozone delivery and topical antibiotics have been integrated into a single application patch. The drug delivery NFs are generated via electrospinning in a fast-dissolve PVA mat without inducing decreasing gas permeability of the dressing. A systematic study found ozone generation at 4 mg/h provided optimal ozone levels for high antimicrobial performance with minimal cytotoxicity. This ozone treatment was used with adjunct therapy delivered by the system in vitro. Results showed complete eradication of Gram-negative bacteria with ozone and antibiotics typically used only for Gram-positive bacteria, which showed the strength of ozone as an enabling adjunct treatment option to sensitize bacteria strains to otherwise ineffective antibiotics. Furthermore, the treatment is shown through biocompatibility testing to exhibit no cytotoxic effect on human fibroblast cells.


Assuntos
Infecções por Bactérias Gram-Negativas , Ozônio , Dispositivos Eletrônicos Vestíveis , Antibacterianos/química , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Bactérias Gram-Negativas , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Testes de Sensibilidade Microbiana , Ozônio/farmacologia , Ozônio/uso terapêutico
17.
Sci Rep ; 12(1): 8011, 2022 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-35568779

RESUMO

Precision Agriculture (PA) is an integral component of the contemporary agricultural revolution that focuses on enhancing food productivity in proportion to the increasing global population while minimizing resource waste. While the recent advancements in PA, such as the integration of IoT (Internet of Things) sensors, have significantly improved the surveillance of field conditions to achieve high yields, the presence of batteries and electronic chips makes them expensive and non-biodegradable. To address these limitations, for the first time, we have developed a fully Degradable Intelligent Radio Transmitting Sensor (DIRTS) that allows remote sensing of subsoil volumetric water using drone-assisted wireless monitoring. The device consists of a simple miniaturized resonating antenna encapsulated in a biodegradable polymer material such that the resonant frequency of the device is dependent on the dielectric properties of the soil surrounding the encapsulated structure. The simple structure of DIRTS enables scalable additive manufacturing processes using cost-effective, biodegradable materials to fabricate them in a miniaturized size, thereby facilitating their automated distribution in the soil. As a proof-of-concept, we present the use of DIRTS in lab and field conditions where the sensors demonstrate the capability to detect volumetric water content within the range of 3.7-23.5% with a minimum sensitivity of 9.07 MHz/%. Remote sensing of DIRTS can be achieved from an elevation of 40 cm using drones to provide comparable performance to lab measurements. A systematic biodegradation study reveals that DIRTS can provide stable readings within the expected duration of 1 year with less than 4% change in sensitivity before signs of degradation. DIRTS provides a new steppingstone toward advancing precision agriculture while minimizing the environmental footprint.


Assuntos
Agricultura , Solo , Coleta de Dados , Água , Tecnologia sem Fio
18.
Mikrochim Acta ; 189(5): 198, 2022 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-35467152

RESUMO

The growing pervasiveness of opioid-based drugs such as fentanyl and its analogs represent a foremost hazard to the civilian population and burden on the first responders and clinicians. Thus, to enable a rapid and low-cost surveillance system to detect fentanyl in a non-ideal environment, we demonstrate the use of laser-induced nano-porous carbon structures directly onto commercially available polyimide sheets for rapid and cost-effective manufacturing of electrochemical sensors for fentanyl detection. The porous carbon surface instigated by various laser energy densities was analyzed towards morphological, vibrational, and fentanyl sensing properties. The results showed that laser carbonized electrode (LCE) prepared with 31 J/cm2 laser energy densities showed the highest level of porosity, surface roughness, and thereby enhanced sensitivity towards fentanyl detection by square-wave voltammetry (SWV) with a 1 µM limit of detection. This new disposable sensor strip offers an information-rich electrochemical fingerprint of fentanyl oxidation at + 0.526 V (vs Ag/AgCl) on the surface of laser carbonized electrodes with high linear (R2 = 0.99) sensitivity (0.025 µA⋅µM-1⋅cm-2) and reproducibility (RSD = 5%), within the clinically relevant working range of 20-200 µM with similar performance in both PBS and serum samples. The laser carbonized electrode surface was further found to be selective towards fentanyl concentrations in the presence of various cutting agents. This technology could provide a new route towards scalable manufacturing of cost-effective sensors for rapid detection of opioid misuse and potentially save the lives from systemic side effects.


Assuntos
Carbono , Fentanila , Eletrodos , Lasers , Porosidade , Reprodutibilidade dos Testes
19.
Langmuir ; 38(13): 4014-4027, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312330

RESUMO

Despite the great advancement and wide use of titanium (Ti) and Ti-based alloys in different orthopedic implants, device-related infections remain the major complication in modern orthopedic and trauma surgery. Most of these infections are often caused by both poor antibacterial and osteoinductive properties of the implant surface. Here, we have demonstrated a facile two-step laser nanotexturing and immobilization of silver onto the titanium implants to improve both cellular integration and antibacterial properties of Ti surfaces. The required threshold laser processing power for effective nanotexturing and osseointegration was systematically determined by the level of osteoblast cells mineralized on the laser nanotextured Ti (LN-Ti) surfaces using a neodymium-doped yttrium aluminum garnet laser (Nd:YAG, wavelength of 1.06 µm). Laser processing powers above 24 W resulted in the formation of hierarchical nanoporous structures (average pore 190 nm) on the Ti surface with a 2.5-fold increase in osseointegration as compared to the pristine Ti surface. Immobilization of silver nanoparticles onto the LN-Ti surface was conducted by dip coating in an aqueous silver ionic solution and subsequently converted to silver nanoparticles (AgNPs) by using a low power laser-assisted photocatalytic reduction process. Structural and surface morphology analysis via XRD and SEM revealed a uniform distribution of Ag and the formation of an AgTi-alloy interface on the Ti surface. The antibacterial efficacy of the LN-Ti with laser immobilized silver (LN-Ti/LI-Ag) was tested against both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria. The LN-Ti/LI-Ag surface was observed to have efficient and stable antimicrobial properties for over 6 days. In addition, it was found that the LN-Ti/LI-Ag maintained a cytocompatibility and bone cell mineralization property similar to the LN-Ti surface. The differential toxicity of the LN-Ti/LI-Ag between bacterial and cellular species qualifies this approach as a promising candidate for novel rapid surface modification of biomedical metal implants.


Assuntos
Nanopartículas Metálicas , Prata , Antibacterianos/química , Antibacterianos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Lasers , Nanopartículas Metálicas/química , Prata/química , Prata/farmacologia , Propriedades de Superfície , Titânio/química
20.
ACS Sens ; 7(4): 960-971, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35333058

RESUMO

During the γ-radiation sterilization process, the levels of radiation exposure to a medical device must be carefully monitored to achieve the required sterilization without causing deleterious effects on its intended physical and chemical properties. To address this issue, here we have demonstrated the development of an all-printed disposable low-cost sensor that exploits the change in electrical impedance of a semi-interpenetrating polymer network (SIPN) composed of poly(vinyl alcohol) (PVA) and poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) as a functional polymer composite for radiation sterilization monitoring applications. Specifically, the PEDOT:PSS acts as the electrically conductive medium, while the PVA provides the ductility and stability of the printed sensors. During irradiation exposure, chain scission and cross-linking events occur concurrently in the PEDOT:PSS and PVA polymer chains, respectively. The concurrent scissoring of the PEDOT polymer and cross-linking of the PVA polymer network leads to the formation of a stable SIPN with reduced electrical conductivity, which was verified through FTIR, Raman, and TGA analysis. Systematic studies of different ratios of PEDOT:PSS and PVA mixtures were tested to identify the optimal ratio that provided the highest radiation sensitivity and stability performance. The results showed that PEDOT:PSS/PVA composites with 10 wt % PVA produced sensors with relative impedance changes of 30% after 25 kGy and up to 370% after 53 kGy (which are two of the most commonly used radiation exposure levels for sterilization applications). This composition showed high electrical impedance stability with less than ±5% change over 18 days after irradiation exposure. These findings demonstrate the feasibility of utilizing a printing technology for scalable manufacturing of low-cost, flexible radiation sensors for more effective monitoring of radiation sterilization processes.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Polímeros , Compostos Bicíclicos Heterocíclicos com Pontes/química , Condutividade Elétrica , Polímeros/química , Esterilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA