Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 14(8): 479-489, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35484942

RESUMO

Aim: Ultra-fast LC was used to establish a new bioanalytical method for enantiomeric separation of oxomemazine. Methods: The proposed study was carried out using the ultra-fast LC technique with an amylose chiral column. The bioanalytical approach was used in rabbit plasma following US FDA regulations and then extended to oxomemazine enantiomeric separation using metronidazole as the internal standard. Results: The retention times of (R)-oxomemazine, (S)-oxomemazine and the internal standard were found to be 9.511, 10.712 and 6.503 min, respectively. Within-run and between-run precision (percent relative standard deviation) was found to be in the range of 0.018-0.102% for (R)-oxomemazine and 0.028-0.675% for (S)-oxomemazine, whereas accuracy (%) was found to be in the range of 95.971-99.720% for (R)-oxomemazine and 97.199-103.921% for (S)-oxomemazine. Conclusion: The findings revealed that stereospecific distribution of oxomemazine enantiomers does not change significantly.


Assuntos
Óxidos S-Cíclicos , Fenotiazinas , Animais , Cromatografia Líquida de Alta Pressão/métodos , Plasma , Coelhos , Reprodutibilidade dos Testes , Estereoisomerismo
2.
Chirality ; 32(8): 1091-1106, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32567097

RESUMO

Enantiomeric resolution and molecular docking studies of meclizine hydrochloride on polysaccharide-based chiral stationary phase comprising cellulose tris(4-methylbenzoate) chiral selector (150 × 4.6 mm, 3.0 µm) were presented. The mobile phase used was acetonitrile:10mM ammonium bicarbonate (95:05, v/v). The developed technique was used to perform the enantioselective assay of meclizine hydrochloride in its marketed formulation. The elution order of meclizine hydrochloride enantiomers was determined by docking studies. Target compound was extracted from rabbit plasma using protein precipitation technique, followed by development of bioanalytical chiral separation method using the same matrix. Application of the method to determine pharmacokinetic parameters of meclizine hydrochloride enantiomers was performed using Phoenix WinNonlin 8.1 software. The results demonstrated stereoselective disposition of meclizine hydrochloride enantiomers in rabbits.


Assuntos
Meclizina/química , Meclizina/farmacocinética , Simulação de Acoplamento Molecular , Animais , Composição de Medicamentos , Meclizina/isolamento & purificação , Coelhos , Estereoisomerismo , Distribuição Tecidual
3.
Perspect Clin Res ; 2(4): 137-44, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22145124

RESUMO

Now-a-days there is significant discussion about patient-reported outcomes (PRO) in medical world. The following article covers almost all the areas of PRO including-their importance, important concepts for understanding of PRO, significance, ideal properties, types, development and evaluation of PRO instruments. It is useful for physicians, pharmacists and patients for the assessment and improvement of the therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA