Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(20): 32761-32771, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37859071

RESUMO

The use of ultrasonic elastic waves is a well established technique for non-destructive testing of materials and structures, in particular to exploit the interaction of waves with structural features to detect and characterize defects. Optical methods offer the advantage of visualising the distribution of elastic waves in a non-contact manner without disturbing the elastic wave. In this work we propose a laser feedback interferometry (LFI) based system as a cost effective, non-contact, alternative to a well established laser Doppler vibrometer technique. We demonstrate the visualization of the elastic waves, using an example of an elastic wave propagating through a prismatic acrylic rod. We show that the ultra-compact and simple implementation of LFI enables accurate visualization of the elastic waves in solids, and opens the pathway to a range of new opportunities in ultrasonic non-destructive testing and evaluation.

2.
Opt Express ; 31(15): 23877-23888, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37475228

RESUMO

The response of terahertz to the presence of water content makes it an ideal analytical tool for hydration monitoring in agricultural applications. This study reports on the feasibility of terahertz sensing for monitoring the hydration level of freshly harvested leaves of Celtis sinensis by employing a imaging platform based on quantum cascade lasers and laser feedback interferometry. The imaging platform produces wide angle high resolution terahertz amplitude and phase images of the leaves at high frame rates allowing monitoring of dynamic water transport and other changes across the whole leaf. The complementary information in the resulting images was fed to a machine learning model aiming to predict relative water content from a single frame. The model was used to predict the change in hydration level over time. Results of the study suggest that the technique could have substantial potential in agricultural applications.

3.
J Phys Chem Lett ; 14(20): 4892-4900, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37199508

RESUMO

Superconducting circuits are among the most advanced quantum computing technologies; however, their performance is limited by losses found in surface oxides and disordered materials. In this work, we demonstrate the identification and spatial localization of a near-field signature of loss centers on tantalum films using terahertz scattering-type scanning near-field optical microscopy. By utilizing terahertz nanospectroscopy, we observe a localized excess vibrational mode around 0.5 THz and identify this resonance as the boson peak, a signature of amorphous materials. Grazing-incidence wide-angle X-ray scattering reveals that oxides on freshly solvent-cleaned samples are amorphous, whereas crystalline phases emerge after aging in air. Through nanoscale localization of defect centers, our findings provide valuable insights for the optimization of fabrication procedures for new low-loss superconducting circuits.

4.
Biomed Opt Express ; 14(4): 1393-1410, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37078035

RESUMO

Early detection of skin pathologies with current clinical diagnostic tools is challenging, particularly when there are no visible colour changes or morphological cues present on the skin. In this study, we present a terahertz (THz) imaging technology based on a narrow band quantum cascade laser (QCL) at 2.8 THz for human skin pathology detection with diffraction limited spatial resolution. THz imaging was conducted for three different groups of unstained human skin samples (benign naevus, dysplastic naevus, and melanoma) and compared to the corresponding traditional histopathologic stained images. The minimum thickness of dehydrated human skin that can provide THz contrast was determined to be 50 µm, which is approximately one half-wavelength of the THz wave used. The THz images from different types of 50 µm-thick skin samples were well correlated with the histological findings. The per-sample locations of pathology vs healthy skin can be separated from the density distribution of the corresponding pixels in the THz amplitude-phase map. The possible THz contrast mechanisms relating to the origin of image contrast in addition to water content were analyzed from these dehydrated samples. Our findings suggest that THz imaging could provide a feasible imaging modality for skin cancer detection that is beyond the visible.

5.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36904925

RESUMO

To reduce the water footprint in agriculture, the recent push toward precision irrigation management has initiated a sharp rise in photonics-based hydration sensing in plants in a non-contact, non-invasive manner. Here, this aspect of sensing was employed in the terahertz (THz) range for mapping liquid water in the plucked leaves of Bambusa vulgaris and Celtis sinensis. Two complementary techniques, broadband THz time-domain spectroscopic imaging and THz quantum cascade laser-based imaging, were utilized. The resulting hydration maps capture the spatial variations within the leaves as well as the hydration dynamics in various time scales. Although both techniques employed raster scanning to acquire the THz image, the results provide very distinct and different information. Terahertz time-domain spectroscopy provides rich spectral and phase information detailing the dehydration effects on the leaf structure, while THz quantum cascade laser-based laser feedback interferometry gives insight into the fast dynamic variation in dehydration patterns.

6.
Sensors (Basel) ; 22(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36433597

RESUMO

In this article, we revisit the concept of optical feedback regimes in diode lasers and explore each regime experimentally from a somewhat unconventional point of view by relating the feedback regimes to the laser bias current and its optical feedback level. The results enable setting the operating conditions of the diode laser in different applications requiring operation in different feedback regimes. We experimentally explored and theoretically supported this relationship from the standard Lang and Kobayashi rate equation model for a laser diode under optical feedback. All five regimes were explored for two major types of laser diodes: inplane lasers and vertical-cavity surface emitting lasers. For both lasers, we mapped the self-mixing strength vs. drive current and feedback level, observed the differences in the shape of the self-mixing fringes between the two laser architectures and a general simulation, and monitored other parameters of the lasers with changing optical feedback.

7.
Sensors (Basel) ; 22(21)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36366193

RESUMO

We have recently reported the self-pulsation phenomenon under strong optical feedback in terahertz (THz) quantum cascade lasers (QCLs). One important issue, however, we left open: the effect of multiple round trips in the external cavity on the laser response to feedback. Our current analysis also casts additional light on the phenomenon of self-pulsations. Using only one external cavity round trip (ECRT) in the model has been the common approach following the seminal paper by Lang-Kobayashi in 1980. However, the conditions under which the Lang-Kobayashi model, in its original single-ECRT formulation, is applicable has been rarely explored. In this work, we investigate the self-pulsation phenomenon under multiple ECRTs. We found that the self-pulsation waveform changes when considering more than one ECRT. This we attribute to the combined effect of the extended external cavity length and the frequency modulation of the pulsation frequency by the optical feedback. Our findings add to the understanding of the optical feedback dynamics under multiple ECRTs and provide a pathway for selecting the appropriate numerical model to study the optical feedback dynamics in THz QCLs and semiconductor lasers in general.

8.
ACS Nano ; 16(10): 16497-16512, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36245096

RESUMO

Biomaterial-associated infections are one of the major causes of implant failure. These infections result from persistent bacteria that have adhered to the biomaterial surface before, during, or after surgery and have formed a biofilm on the implant's surface. It is estimated that 4 to 10% of implant surfaces are contaminated with bacteria; however, the infection rate can be as high as 30% in intensive care units in developed countries and as high as 45% in developing countries. To date, there is no clinical solution to prevent implant infection without relying on the use of high doses of antibiotics supplied systemically and/or removal of the infected device. In this study, melimine, a chimeric cationic peptide that has been tested in Phase I and II human clinical trials, was immobilized onto the surface of 3D-printed medical-grade polycaprolactone (mPCL) scaffolds via covalent binding and adsorption. X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectra of melimine-treated surfaces confirmed immobilization of the peptide, as well as its homogeneous distribution throughout the scaffold surface. Amino acid analysis showed that melimine covalent and noncovalent immobilization resulted in a peptide density of ∼156 and ∼533 ng/cm2, respectively. Furthermore, we demonstrated that the immobilization of melimine on mPCL scaffolds by 1-ethyl-3-[3-(dimethylamino)propyl] carbodiimide hydrochloride (EDC) coupling and noncovalent interactions resulted in a reduction of Staphylococcus aureus colonization by 78.7% and 76.0%, respectively, in comparison with the nonmodified control specimens. Particularly, the modified surfaces maintained their antibacterial properties for 3 days, which resulted in the inhibition of biofilm formation in vitro. This system offers a biomaterial strategy to effectively prevent biofilm-related infections on implant surfaces without relying on the use of prophylactic antibiotic treatment.


Assuntos
Peptídeos Catiônicos Antimicrobianos , Pseudomonas aeruginosa , Humanos , Peptídeos Catiônicos Antimicrobianos/química , Biofilmes , Antibacterianos/farmacologia , Antibacterianos/química , Materiais Revestidos Biocompatíveis/química , Bactérias , Aminoácidos , Carbodi-Imidas/farmacologia , Impressão Tridimensional
9.
Nat Commun ; 13(1): 4294, 2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35879290

RESUMO

Measuring polarisation, spectrum, temporal dynamics, and spatial complex amplitude of optical beams is essential to studying phenomena in laser dynamics, telecommunications and nonlinear optics. Current characterisation techniques apply in limited contexts. Non-interferometric methods struggle to distinguish spatial phase, while phase-sensitive approaches necessitate either an auxiliary reference source or a self-reference, neither of which is universally available. Deciphering complex wavefronts of multiple co-propagating incoherent fields remains particularly challenging. We harness principles of spatial state tomography to circumvent these limitations and measure a complete description of an unknown beam as a set of spectrally, temporally, and polarisation resolved spatial state density matrices. Each density matrix slice resolves the spatial complex amplitude of multiple mutually incoherent fields, which over several slices reveals the spectral or temporal evolution of these fields even when fields spectrally or temporally overlap. We demonstrate these features by characterising the spatiotemporal and spatiospectral output of a vertical-cavity surface-emitting laser.

10.
Opt Express ; 29(24): 39885-39895, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809343

RESUMO

In this article, we explore the interplay between the self-pulsations (SPs) and self-mixing (SM) signals generated in terahertz (THz) quantum cascade lasers (QCLs) under optical feedback. We find that optical feedback dynamics in a THz QCL, namely, SPs, modulate the conventional SM interference fringes in a laser feedback interferometry system. The phenomenon of fringe loss in the SM signal - well known in interband diode lasers - was also observed along with pronounced SPs. With an increasing optical feedback strength, SM interference fringes transition from regular fringes at weak feedback (C ≤ 1) to fringes modulated by SPs under moderate feedback (1 < C ≤ 4.6), and then [under strong feedback (C > 4.6)] to a SM waveform with reduced number of fringes modulated by SP, until eventually (under even greater feedback) all the fringes are lost and only SPs are left visible. The transition route described above was identified in simulation when the SM fringes are created either by a moving target or a current modulation of the THz QCL. This SM signal transition route was successfully validated experimentally in a pulsed mode THz QCL with SM fringes created by current modulation during the pulse. The effects of SP dynamics in laser feedback interferometric system investigated in this work not only provides a further understanding of nonlinear dynamics in a THz QCL but also helps to understand the SM waveforms generated in a THz QCLs when they are used for various sensing and imaging applications.

11.
Nanotechnology ; 33(6)2021 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34715680

RESUMO

Significant efforts have recently been invested in assessing the physical and chemical properties of microbial nanowires for their promising role in developing alternative renewable sources of electricity, bioelectronic materials and implantable sensors. One of their outstanding properties, the ever-desirable conductivity has been the focus of numerous studies. However, the lack of a straightforward and reliable method for measuring it seems to be responsible for the broad variability of the reported data. Routinely employed methods tend to underestimate or overestimate conductivity by several orders of magnitude. In this work, synthetic peptide nanowires conductivity is interrogated employing a non-destructive measurement technique developed on a terahertz scanning near-field microscope to test if peptide aromaticity leads to higher electrical conductivity. Our novel peptide conductivity measurement technique, based on triple standards calibration method, shows that in the case of two biopolymer mimicking peptides, the sample incorporating aromatic residues (W6) is about six times more conductive than the negative control (L6). To the best of our knowledge, this is the first report of a quantitative nano-scale terahertz s-SNOM investigation of peptides. These results prove the suitability of the terahertz radiation-based non-destructive approach in tandem with the designer peptides choice as model test subjects. This approach requires only simple sample preparation, avoids many of the pitfalls of typical contact-based conductivity measurement techniques and could help understanding fundamental aspects of nature's design of electron transfer in biopolymers.


Assuntos
Condutividade Elétrica , Nanofios/química , Peptídeos/química , Espectroscopia Terahertz , Microscopia
12.
Opt Express ; 28(10): 14246-14262, 2020 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-32403467

RESUMO

The typical modal characteristics arising during laser feedback interferometry (LFI) in multi-mode terahertz (THz) quantum cascade lasers (QCLs) are investigated in this work. To this end, a set of multi-mode reduced rate equations with gain saturation for a general Fabry-Pérot multi-mode THz QCL under optical feedback is developed. Depending on gain bandwidth of the laser and optical feedback level, three different operating regimes are identified, namely a single-mode regime, a multi-mode regime, and a tuneable-mode regime. When the laser operates in the single-mode and multi-mode regimes, the self-mixing signal amplitude (peak to peak value of the self-mixing fringes) is proportional to the feedback coupling rate at each mode frequency. However, this rule no longer holds when the laser enters into the tuneable-mode regime, in which the feedback level becomes sufficiently strong (the boundary value of the feedback level depends on the gain bandwidth). The mapping of the identified feedback regimes of the multi-mode THz QCL in the space of the gain bandwidth and feedback level is investigated. In addition, the dependence of the aforementioned mapping of these three regimes on the linewidth enhancement factor of the laser is also explored, which provides a systematic picture of the potential of LFI in multi-mode THz QCLs for spectroscopic sensing applications.

13.
Opt Express ; 27(7): 10221-10233, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31045166

RESUMO

We report a coherent terahertz (THz) imaging system that utilises a quantum cascade laser (QCL) operating in pulsed-mode as both the source and detector. The realisation of a short-pulsed THz QCL feedback interferometer permits both high peak powers and improved thermal efficiency, which enables the cryogen-free operation of the system. In this work, we demonstrated pulsed-mode swept-frequency laser feedback interferometry experimentally. Our interferometric detection scheme not only permits the simultaneous creation of both amplitude and phase images, but inherently suppresses unwanted background radiation. We demonstrate that the proposed system utilising microsecond pulses has the potential to achieve 0.25 mega-pixel per second acquisition rates, paving the pathway to video frame rate THz imaging.

14.
Sci Rep ; 8(1): 17648, 2018 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-30504784

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

15.
Nat Commun ; 9(1): 5181, 2018 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-30504849

RESUMO

The original version of this Article contained an error in the Acknowledgements, which incorrectly omitted the following: 'We also acknowledge support from the Australian Research Council's Discovery Projects Funding Scheme (Grant DP 160 103910).' This has been corrected in both the PDF and HTML versions of the Article.

16.
Opt Express ; 26(20): 25778-25792, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469674

RESUMO

In this work, we present a method to discriminate between different microparticle sizes in mixed flowing media based on laser feedback interferometry, which could ultimately form the basis for a small, low-cost, real-time microembolus detector. We experimentally evaluated the performance of the system using microparticle phantoms, and the system achieved approximately 45% positive predictive value and better than 98% negative predictive value in the detection and classification of abnormally large particles.

17.
Nat Commun ; 9(1): 3076, 2018 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-30082762

RESUMO

Single-mode frequency-tuneable semiconductor lasers based on monolithic integration of multiple cavity sections are important components, widely used in optical communications, photonic integrated circuits and other optical technologies. To date, investigations of the ultrafast switching processes in such lasers, essential to reduce frequency cross-talk, have been restricted to the observation of intensity switching over nanosecond-timescales. Here, we report coherent measurements of the ultrafast switch-on dynamics, mode competition and frequency selection in a monolithic frequency-tuneable laser using coherent time-domain sampling of the laser emission. This approach allows us to observe hopping between lasing modes on picosecond-timescales and the temporal evolution of transient multi-mode emission into steady-state single mode emission. The underlying physics is explained through a full multi-mode, temperature-dependent carrier and photon transport model. Our results show that the fundamental limit on the timescales of frequency-switching between competing modes varies with the underlying Vernier alignment of the laser cavity.

18.
Appl Opt ; 57(15): 4067-4074, 2018 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-29791380

RESUMO

Specular reflection from the surface of targets or prepared specimens represents a significant problem in optical microscopy and related optical imaging techniques as usually the surface reflection does not contribute to the desired signal. Solutions exist for many of these imaging techniques; however, remedial techniques for imaging based on laser feedback interferometry (LFI) are absent. We propose a reflection cancellation technique based on crossed-polarization filtering that is tailored for a typical LFI configuration. The technique is validated with three experimental designs, and a significant improvement of about 40 dB in the ratio of the diffuse and specular LFI signal is observed. Applications of this principle extend from specular reflection removal to characterization of target materials in industrial to biomedical domains.

19.
Biomed Opt Express ; 8(9): 4037-4048, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28966845

RESUMO

Tomographic imaging of soft tissue such as skin has a potential role in cancer detection. The penetration of infrared wavelengths makes a confocal approach based on laser feedback interferometry feasible. We present a compact system using a semiconductor laser as both transmitter and receiver. Numerical and physical models based on the known optical properties of keratinocyte cancers were developed. We validated the technique on three phantoms containing macro-structural changes in optical properties. Experimental results were in agreement with numerical simulations and structural changes were evident which would permit discrimination of healthy tissue and tumour. Furthermore, cancer type discrimination was also able to be visualized using this imaging technique.

20.
Sci Rep ; 7(1): 7236, 2017 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-28775327

RESUMO

The effects of optical feedback (OF) in lasers have been observed since the early days of laser development. While OF can result in undesirable and unpredictable operation in laser systems, it can also cause measurable perturbations to the operating parameters, which can be harnessed for metrological purposes. In this work we exploit this 'self-mixing' effect to infer the emission spectrum of a semiconductor laser using a laser-feedback interferometer, in which the terminal voltage of the laser is used to coherently sample the reinjected field. We demonstrate this approach using a terahertz frequency quantum cascade laser operating in both single- and multiple-longitudinal mode regimes, and are able to resolve spectral features not reliably resolved using traditional Fourier transform spectroscopy. We also investigate quantitatively the frequency perturbation of individual laser modes under OF, and find excellent agreement with predictions of the excess phase equation central to the theory of lasers under OF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA