Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 949-962, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38566525

RESUMO

BACKGROUND: Atherectomy is an important option for debulking atherosclerotic plaque from diseased arteries in patients with infrainguinal arterial disease. Laser atherectomy uses a high-powered laser to remove the plaque from the arteries to restore blood flow. AIMS: The Pathfinder multicenter registry was initiated to evaluate the safety and efficacy of the 355 nm laser atherectomy system in a real-world setting for the treatment of de novo, re-stenotic and in-stent restenosis (ISR) lesions in infrainguinal arteries of patients with peripheral artery disease (PAD). METHODS: The study was a prospective, single-arm, multicenter, open-label registry study for patients treated with the 355 nm laser system. Clinical and lesion characteristics, procedural safety and efficacy data, and baseline, 6-, and 12-month outcomes data, including Ankle Brachial Index (ABI), Rutherford class, and Walking Impairment Questionnaires (WIQ), were collected. The primary efficacy endpoint was the achievement of ≤30% final residual stenosis at the index lesion postatherectomy and adjunctive therapy evaluated by an angiographic Core Lab. The primary safety endpoint was the percentage of subjects who did not experience periprocedural major adverse events (PPMAEs) before discharge. RESULTS: One hundred and two subjects with 121 lesions treated with the 355 nm laser device at 10 centers were included in the analysis. Mean age was 68.4 ± 10.21 years, 61.8% of subjects were male, 44.6% had critical limb ischemia (CLI), and 47.3% had tibial lesions. The mean residual stenosis at the end of the procedure was 24.4 ± 15.5 with 69 lesions (69.0%) achieving technical procedural success (<30% stenosis); similar rates were observed for subjects with ISR (25.5 ± 14.9), chronic total occlusion (CTO) (28.1 ± 17.0), and severe calcification (36.5 ± 21.6) lesions. Mean ABI, Rutherford, and WIQ scores were improved at both 6 and 12 months. Ninety-seven of 102 subjects (95.1%) met the primary safety endpoint of not experiencing a PPMAE before discharge. CONCLUSIONS: The initial data from the Pathfinder Registry demonstrates the 355 nm laser system is safe and effective in a real-world setting for performing atherectomy in patients with infrainguinal PAD.


Assuntos
Aterectomia , Doença Arterial Periférica , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Resultado do Tratamento , Aterectomia/efeitos adversos , Aterectomia/instrumentação , Fatores de Tempo , Idoso de 80 Anos ou mais , Lasers de Estado Sólido/uso terapêutico , Lasers de Estado Sólido/efeitos adversos , Pessoa de Meia-Idade , Recidiva , Estados Unidos , Índice Tornozelo-Braço , Recuperação de Função Fisiológica , Grau de Desobstrução Vascular , Stents
2.
J Vasc Surg ; 78(4): 929-935.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330148

RESUMO

OBJECTIVE: There is no proven therapy to reduce growth rates of small- to medium-sized abdominal aortic aneurysms (AAAs). Ex vivo and animal studies have demonstrated that a novel stabilizing agent, 1,2,3,4,6-pentagalloyl glucose (PGG), delivered locally to the aneurysm sac, can bind to elastin and collagen to re-establish strength and resist enzymatic degradation. We aimed to demonstrate that a one-time administration of PGG solution to the aneurysm wall is safe and potentially effective to slow the growth of small- to medium-sized AAAs. METHODS: Patients with small- to medium-sized infrarenal AAAs (maximum diameter <5.5 cm) were recruited. Via transfemoral access, a 14F or 16F dual-balloon delivery catheter was introduced into the aneurysm sac. A single, 3-minute, localized endoluminal infusion of PGG was delivered via a 'weeping' balloon to the aneurysm wall. Independent core laboratory measurements of maximum aneurysm sac diameter and sac volume measurements based on computed tomography angiography (CTA) were used for assessments at 1, 6, 12, 24, and 36 months. The primary endpoints were technical success and safety (major adverse events at 30 days). The secondary endpoint was growth stabilization, defined as freedom from aneurysm sac enlargement (diameter increase >5 mm per year or volume increase of >10% per year). RESULTS: Twenty patients (19 male) were enrolled at five centers from May 2019 to June 2022 (mean age, 67.8 years; range, 50-87 years). All procedures were technically successful. The safety profile was consistent with standard interventional procedures. Four patients demonstrated transient elevations of liver enzymes levels that returned to normal by 30 days with no clinical symptoms. Through November 2022, follow-up CTA data is available on the first 11 patients. The average changes in maximum aneurysm diameter from baseline to 6, 12, 24, and 36 months were 0.2 mm, 1.1 mm, 1.2 mm, and 0.8 mm, respectively, and the average changes in volume were 2.0%, 9.6%, 18.1%, and 11.6%, respectively. At 12 months, none of the aneurysms showed growth >5.0 mm, and three had volume growth >10%. CONCLUSIONS: The early results of this first-in-human, small cohort study demonstrated that a single, localized PGG administration to patients with small- to medium-sized infrarenal AAAs is safe. Longer term follow-up on all 20 treated patients is needed to better assess the potential impact on aneurysm growth.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Projetos Piloto , Estudos de Coortes , Aorta Abdominal , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Tomografia Computadorizada por Raios X , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Prótese Vascular , Desenho de Prótese
3.
J Thorac Cardiovasc Surg ; 163(5): 1739-1750.e4, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35241276

RESUMO

OBJECTIVE: The study objective was to evaluate the safety and effectiveness of the second-generation, low-profile RelayPro (Terumo Aortic) thoracic endograft for the treatment of descending thoracic aortic aneurysm or penetrating atherosclerotic ulcer. METHOD: A prospective, international, nonblinded, nonrandomized, pivotal trial analyzed a primary safety end point of major adverse events at 30 days (death, myocardial infarction, stroke, renal/respiratory failure, paralysis, bowel ischemia, procedural blood loss) and a primary effectiveness end point of treatment success at 1 year (technical success, patency, absence of aneurysm rupture, type I/III endoleaks, stent fractures, reinterventions, aneurysm expansion, and migration) compared with performance goals from the previous generation Relay pivotal study. The study was conducted in 36 centers in the United States and Japan and enrolled participants between 2017 and 2019. RESULTS: The study population of 110 patients had a median (interquartile range) age of 76 (70-81) years, 69 (62.7%) were male, and 43 (39.1%) were Asian. Patients were treated for 76 fusiform aneurysms (69%), 24 saccular aneurysms (22%), and 10 penetrating atherosclerotic ulcers (9%). Most patients (82.7%) were treated with a non-bare stent configuration. Technical success was 100%. The median (interquartile range) procedure time was 91 (64-131) minutes, and the deployment time was 16 (10-25) minutes. A total of 50 patients (73.5%) in the US cohort had percutaneous access, whereas centers in Japan used only surgical cutdown. The 30-day composite major adverse events rate was 6.4% (95% upper confidence interval, 11.6%; P = .0002): 2 strokes, 2 procedural blood losses greater than 1000 mL requiring transfusion, 2 paralysis events, and 1 renal failure. Primary effectiveness was 89.2% (lower 95% confidence interval, 81.8%; P = .0185). Nine subjects experienced 11 events (1 aneurysm expansion, 6 secondary interventions, and 4 type I endoleaks). There was no loss of stent-graft patency, no rupture, no fractures, and no migration. CONCLUSIONS: The low-profile RelayPro thoracic endograft met the study primary end points and demonstrated satisfactory 30-day safety and 1-year effectiveness for the treatment of patients with aneurysms of the descending thoracic aorta or penetrating atherosclerotic ulcers. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Aterosclerose , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Aterosclerose/etiologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Paralisia/etiologia , Paralisia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Stents , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/cirurgia , Estados Unidos
4.
Vasc Health Risk Manag ; 15: 385-393, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31564888

RESUMO

BACKGROUND: Perioperative health care utilization and costs in patients undergoing elective fast-track vs standard endovascular aneurysm repair (EVAR) remain unclear. METHODS: The fast-track EVAR group included patients treated with a 14 Fr stent graft, bilateral percutaneous access, no general anesthesia or intensive care monitoring, and next-day hospital discharge. The standard EVAR group was identified from Medicare administrative claims using a matching algorithm to adjust for imbalances in patient characteristics. Hospital outcomes included operating room time, intensive care monitoring, hospital stay, secondary interventions, and major adverse events (MAEs). Perioperative outcomes occurring from hospital discharge to 30 days postdischarge included MAE, secondary interventions, and unrelated readmissions. RESULTS: Among 1000 matched patients (250 fast-track; 750 standard), hospital outcomes favored the fast-track EVAR group, including shorter operating room time (2.30 vs 2.83 hrs, P<0.001), shorter hospital stay (1.16 vs 1.69 d, P<0.001), less need for intensive care monitoring (4.4% vs 48.0%, P<0.001), and lower secondary intervention rate (0% vs 2.4%, P=0.01). Postdischarge outcomes also favored fast-track EVAR with a lower rate of MAE (0% vs 7.2%, P<0.001) and all-cause readmission (1.6% vs 6.8%, P=0.001). The total cost to the health care system during the perioperative period was $26,730 with fast-track EVAR vs $30,730 with standard EVAR. Total perioperative health care costs were $4000 (95% CI: $3130-$4830) lower with fast-track EVAR vs standard EVAR, with $2980 in savings to hospitals and $1030 savings to health care payers. CONCLUSION: A fast-track EVAR protocol using a 14 Fr stent graft resulted in shorter procedure time, lower intensive care utilization, faster discharge, lower incidence of MAE, lower readmission rates, and lower perioperative costs compared to standard EVAR.


Assuntos
Aneurisma da Aorta Abdominal/economia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/economia , Procedimentos Endovasculares/economia , Custos Hospitalares , Avaliação de Processos e Resultados em Cuidados de Saúde/economia , Alta do Paciente/economia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular/economia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Redução de Custos , Análise Custo-Benefício , Cuidados Críticos/economia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Tempo de Internação/economia , Masculino , Duração da Cirurgia , Readmissão do Paciente/economia , Desenho de Prótese , Sistema de Registros , Retratamento/economia , Stents/economia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
5.
J Endovasc Ther ; 25(1): 6-13, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29251207

RESUMO

PURPOSE: To determine the feasibility, perioperative resource utilization, and safety of a fast-track endovascular aneurysm repair (EVAR) protocol in well-selected patients. METHODS: Between October 2014 and May 2016, the LIFE (Least Invasive Fast-track EVAR) registry ( ClinicalTrials.gov identifier NCT02224794) enrolled 250 patients (mean age 73±8 years; 208 men) in a fast-track EVAR protocol comprised of bilateral percutaneous access using the 14-F Ovation stent-graft, no general anesthesia, no intensive care unit (ICU) admission, and next-day discharge. The primary endpoint was major adverse events (MAE) through 30 days. The target performance goal for the MAE endpoint was 10.4%. RESULTS: Vascular access, stent-graft delivery, and stent-graft deployment success were 100%. A total of 216 (86%) patients completed all elements of the fast-track EVAR protocol. Completion of individual elements was 98% for general anesthesia avoidance, 97% for bilateral percutaneous access, 96% for ICU avoidance, and 92% for next-day discharge. Perioperative outcomes included mean procedure time of 88 minutes, median blood loss of 50 mL, early oral nutrition (median 6 hours), early mobilization (median 8 hours), and short hospitalization (median 26 hours). Fast-track EVAR completers had shorter procedure time (p<0.001), less blood loss (p=0.04), faster return to oral nutrition (p<0.001) and ambulation (p<0.01), and shorter hospital stay (p<0.001). With 241 (96%) of the 250 patients returning for the 30-day follow-up, the MAE incidence was 0.4% (90% CI 0.1% to 1.8%), significantly less than the 10.4% performance goal (p<0.001). No aneurysm rupture, conversion to surgery, or aneurysm-related secondary procedure was reported. There were no type III endoleaks and 1 (0.4%) type I endoleak. Iliac limb occlusion was identified in 2 (0.8%) patients. The 30-day hospital readmission rate was 1.6% overall. CONCLUSION: A fast-track EVAR protocol was feasible in well-selected patients and resulted in efficient perioperative resource utilization with excellent safety and effectiveness.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Tempo de Internação , Alta do Paciente , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
6.
Vascular ; 25(6): 563-575, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28950783

RESUMO

Objectives To evaluate the novel Phoenix Atherectomy System as percutaneous treatment of de novo and restenotic infrainguinal arterial lesions. Methods This prospective, multicenter, nonrandomized investigational device exemption trial was conducted across 16 US and German centers between August 2010 and April 2013. Intention-to-treat enrollment was 128 patients (mean age: 71.8 years, 59% male) with 149 lesions (mean length: 34 mm, mean diameter stenosis: 89.5%), and the primary analysis per-protocol population consisted of 105 patients with 123 lesions. The primary efficacy endpoint, technical success, was the achievement of acute debulking with a post-atherectomy residual diameter stenosis ≤50% (before adjunctive therapy). The primary safety endpoint was the major adverse event (MAE) rate through 30 days. Results For the primary analysis per-protocol population, the rate of lesion technical success was 95.1% (117/123), with the lower limit of the 95% CI 90.6%, meeting the prospectively established target performance goal of ≥86%. After post-atherectomy adjunctive therapy, residual stenosis was ≤30% for 99.2% (122/123) of lesions (mean final diameter stenosis 10.5%). Improvement of ≥1 Rutherford class occurred for 74.5% of patients through 30 days and for 80% through six months. MAEs were experienced by 5.7% (6/105) of patients through 30 days (with the upper limit of the 95% CI 11.0%, meeting the target performance goal of <20%), and 16.8% through six months. Six-month freedom from TLR and TVR was 88.0% and 86.1%, respectively. Conclusions Based on the high rate of technical success and the low rates of MAEs through six months, the Phoenix Atherectomy System is safe and effective for the debulking of lower-extremity arterial lesions. ClinicalTrials.gov identifier NCT01541774.


Assuntos
Aterectomia/instrumentação , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Aterectomia/efeitos adversos , Constrição Patológica , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
7.
J Endovasc Ther ; 24(4): 478-487, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28504047

RESUMO

PURPOSE: To validate 3 angiographic scoring systems for peripheral artery calcification using intravascular ultrasound (IVUS) as the gold standard. METHODS: The study employed preprocedure angiography and IVUS data from 47 patients (median age 72 years; 34 men) in the 55-patient JetStream G3 Calcium Study ( ClinicalTrials.gov identifier NCT01273623) to validate the 3 angiographic scoring systems [Peripheral Academic Research Consortium (PARC), Peripheral Arterial Calcium Scoring System (PACSS), and the DEFINITIVE Ca++ trial]. Preprocedure angiograms were analyzed using conventional quantitative vessel analysis software in 2 orthogonal views. Calcium length was evaluated by markers placed beside the artery during the procedure; calcium deposit(s) were assessed as being on one or both sides of the vessel wall. The 3 calcium scoring systems used these 2 basic angiographic elements to evaluate calcium severity. Based on these criteria, calcium severity varied from none to focal, mild, moderate, or severe in PARC; grade 0 to 4 in PACSS; and none, moderate, or severe in the DEFINITIVE Ca++ system. Calcium location on IVUS was classified as superficial, deep, or mixed. Lesion length was the segment between the most normal looking proximal and distal reference sites. Superficial, deep, and calcium length were based on motorized IVUS pullback. RESULTS: IVUS detected calcium in 44/47 (93.6%) lesions, and angiography detected calcium in 26/47 (55.3%) lesions (p<0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of angiography relative to IVUS were 59%, 100%, 100%, and 14%, respectively. With increasing severity of angiographic calcium, there was a stepwise increase in the prevalence of IVUS superficial calcium and the maximum arc and length of superficial calcium. Using PARC criteria, with increasing severity of calcification, IVUS maximum calcium arc increased from 120° for none to 305° for severe (p<0.001); the length of calcium increased from 7 to 68 mm (p<0.001). Though a similar trend was seen in IVUS superficial calcium, it was not observed in IVUS deep calcium. Similar observations were seen when using the PACSS and DEFINITIVE Ca++ scoring systems. CONCLUSION: IVUS confirmed that the PARC, PACSS, and DEFINITIVE Ca++ calcium scoring systems can be used to classify the degree of calcium in peripheral artery disease, especially superficial calcium.


Assuntos
Angiografia/métodos , Doença Arterial Periférica/diagnóstico por imagem , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
8.
Catheter Cardiovasc Interv ; 88(7): 1118-1123, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27404487

RESUMO

OBJECTIVE: To assess the feasibility, safety, and clinical utility of a fast-track endovascular aneurysm repair (EVAR) protocol. BACKGROUND: Despite recent advances in EVAR technology and techniques, considerable opportunity exists to further improve EVAR efficiency and outcomes. METHODS: Eligible patients underwent elective EVAR with the Ovation Prime stent graft. Successful completion of the fast-track protocol required bilateral percutaneous access, avoidance of general anesthesia and intensive care unit admission, and next-day discharge. Patients were followed through 1-month post-treatment. RESULTS: Between October 2014 and September 2015, 129 patients were enrolled in the study. Vascular access, stent graft delivery, and stent graft deployment were successful in all patients. The fast-track EVAR protocol was successfully completed in 114 (88%) patients. Bilateral percutaneous access was achieved in 97% of cases. Comparing patients who completed fast-track requirements to those who failed at least one component, procedure time was 86 vs. 122 min, use of general anesthesia was 0% vs. 20%, need for intensive care unit stay was 0% vs. 13%, hospital stay was 1.1 vs. 2.1 days, and postoperative groin pain severity (0-10 scale) was 1.2 vs. 4.0. No type I or III endoleaks, serious device-related adverse events, AAA ruptures, surgical conversions, or AAA-related secondary procedures were reported. One (0.9%) patient in the fast-track group died from acute respiratory failure. CONCLUSIONS: Initial results from the LIFE study are encouraging and suggest that a fast-track protocol is feasible, safe, and may improve efficiency of healthcare resource allocation in select patients undergoing EVAR. © 2016 Wiley Periodicals, Inc.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Tempo de Internação , Alta do Paciente , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Atenção à Saúde/organização & administração , Eficiência Organizacional , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Dor Pós-Operatória/etiologia , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/mortalidade , Stents , Fatores de Tempo , Gerenciamento do Tempo , Resultado do Tratamento , Estados Unidos
9.
Catheter Cardiovasc Interv ; 87(1): 75-81, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25599884

RESUMO

OBJECTIVES: To evaluate the use of the Boomerang™ Wire as an adjunct to manual compression (MC) in patients requiring diagnostic (Dx) or interventional (Ix) percutaneous procedures. BACKGROUND: MC remains the standard of care for closure of femoral artery access sites. Adjunctive use of a device to facilitate closure, reduce time to hemostasis (TTH) and ambulation (TTA) without increasing complication rates could reduce costs and hospital resource demands. METHODS: The Boomerang™ Trial was a prospective, multicenter, randomized, controlled trial comparing use of the Boomerang™ wire, (Cardiva Medical, Sunnyvale, CA) in conjunction with MC versus MC alone to achieve hemostasis in Dx and Ix patients undergoing percutaneous procedures requiring femoral artery access. Endpoints included TTH, TTA, major, and minor access-site related complications. Subjects were randomized 3:1, Boomerang versus MC. RESULTS: No minor or major device-related adverse events were reported. Nondevice related complication rates were 3 (0.9%) in the Boomerang arm (n = 327) and 1 (0.8%) in MC arm (n = 123). Mean TTH for Boomerang vs. MC was 11.2 ± 4.3 vs. 23.2 ± 11 min for Dx (P < 0.0001) and 13.9 ± 5.4 vs. 38.4 ± 57.3 min for Ix patients (P < 0.0001). Mean TTA for Boomerang vs. MC was 3.3 ± 3.0 vs. 4.5 ± 2.0 hr (P < 0.0001)for Dx and 5.4 ± 3.3 vs. 6.8 ± 3.2 hr (P < 0.0001) for Ix patients. CONCLUSIONS: Boomerang™ use, in conjunction with MC, was associated with low rates of complications and demonstrated that Boomerang™ as an adjunct to MC can significantly decrease TTH and TTA after both Dx and Ix procedures. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Técnicas Hemostáticas/instrumentação , Hemorragia Pós-Operatória/terapia , Punções/efeitos adversos , Dispositivos de Oclusão Vascular , Idoso , Desenho de Equipamento , Feminino , Artéria Femoral , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 15: 174, 2015 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-26685936

RESUMO

BACKGROUND: Considerable technological advancements have recently been made with endovascular stent grafts for the treatment of abdominal aortic aneurysm (AAA). However, there is opportunity to further improve the efficiency of endovascular aneurysm repair (EVAR), which may yield better patient outcomes and lower perioperative treatment costs. METHODS/DESIGN: The Least Invasive Fast-Track EVAR (LIFE) registry was developed to determine the clinical utility and cost effectiveness of the Ovation® Prime stent graft when used under least invasive conditions using a defined fast-track protocol. The LIFE study is a prospective multicenter post-market registry of the ultra-low profile (14F) Ovation Prime stent graft when used in the treatment of patients with AAA using a fast-track protocol, consisting of appropriate patient selection, bilateral percutaneous access, avoidance of general anesthesia and intensive care unit admission, and next-day discharge. The primary endpoint of the study is the proportion of subjects that experience a major adverse event within 30 days of the initial procedure. Primary endpoint data will be compared to a target performance goal. A total of 250 subjects will be enrolled at up to 40 sites in the United States. The first subject in this study was enrolled in October 2014 and enrollment is anticipated to continue through mid-2016. DISCUSSION: The recent development of ultra low-profile stent grafts enables EVAR using least invasive methods. A structured fast-track EVAR protocol may yield clinical and cost benefits versus standard EVAR. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02224794.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Sistema de Registros , Projetos de Pesquisa , Stents , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/economia , Prótese Vascular/economia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/economia , Análise Custo-Benefício , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Custos de Cuidados de Saúde , Humanos , Complicações Pós-Operatórias/etiologia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Stents/economia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
11.
EuroIntervention ; 11(1): 96-103, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25982651

RESUMO

AIMS: Endovascular treatment of calcified femoral-popliteal disease is challenging. We sought to evaluate the mechanism of lumen gain when using the JETSTREAM Atherectomy System to treat calcified peripheral artery lesions. METHODS AND RESULTS: The JETSTREAM Calcium Study was a prospective, single-arm, multicentre study to evaluate the JETSTREAM Atherectomy System for severely calcified femoral-popliteal artery lesions, i.e., patients with claudication and lesions with superficial calcium >90° and >5 mm in length as determined by intravascular ultrasound (IVUS). The 2.1 mm catheter was used in this study without distal protection. Fifty-five patients underwent angiographic screening: 26 (45%) met IVUS inclusion criteria. Angiographic calcium was moderate in eight cases and severe in 14, with no available data for four cases. Visual diameter stenosis was 86±9% pre-treatment, 37±13% post atherectomy, and 10±6% post adjunctive treatment (adjunctive PTA+stenting in eight and adjunct PTA alone in 16). IVUS showed lumen area increased from 6.6±3.7 mm2 to 10.0±3.6 mm2 (p=0.001): calcium reduction was responsible for 86±23% of the lumen increase. Although the superficial calcium arc did not change (151±70° to 146±71°, p=0.83), the arc of reverberation increased (23±20° to 65±40°, p=0.006), indicating device-related modification of calcium. Adjunctive balloon angioplasty was performed in 62% of the lesions, and stent implantation in 31%. In 11 cases with adjunctive balloon dilation, the MLA increased from 7.1 (6.4, 7.8) mm2 post atherectomy to 11.9 (10.3, 13.5) mm2 post balloon (p<0.001) without flow-limiting dissection. No major adverse events occurred up to 30 days post procedure in either the study group or the patients who were excluded from the analysis. CONCLUSIONS: The JETSTREAM Atherectomy System increased lumen dimensions in moderately or severely calcified femoral-popliteal lesions by removing superficial calcium without major complications.


Assuntos
Aterectomia/métodos , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Ultrassonografia de Intervenção , Calcificação Vascular/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Aterectomia/instrumentação , Constrição Patológica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia , Índice de Gravidade de Doença , Stents , Resultado do Tratamento , Dispositivos de Acesso Vascular , Calcificação Vascular/diagnóstico por imagem
12.
World J Surg ; 36(11): 2738-41, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22791195

RESUMO

BACKGROUND: Variability exists between institutions in the application of endovascular aneurysm repair (EVAR). This study compares patient-specific variables from a high-volume North American institution with one from the UK. METHODS: One hundred consecutive patients from each institution were studied. All were treated for an intact, infrarenal aortic aneurysm. Patient characteristics and aneurysm-related variables, measured from computed tomography according to Society for Vascular Surgery (USA) reporting standards, were examined. RESULTS: The median (range) age of the American patients was 74 (55-97) years and that of the British patients, 73 (49-89) years. There were 78 men in the American group and 79 men in the British group. All American patients were treated by EVAR compared to 11 % of the British group. Mean (SD) aneurysm diameter for the former was 55 (9) mm and for the latter 64 (11) mm (P < 0.001). While there was no difference in mean diameter of the infrarenal aortic neck (P = 0.918), the aneurysms of British patients (22 %) were more likely to be angulated >60° than those of the American patients (11 %) (P = 0.039). Furthermore, the mean (SD) length of infrarenal aortic neck was shorter in the British patients [21 (11) mm] compared to the American group [25 (12) mm] (P = 0.003). The mean diameter of the common iliac arteries was larger in the British patients than in the American group (P < 0.001). Mean external iliac artery diameter was no different between the groups (P = 0.507). CONCLUSIONS: This group of British patients have a more advanced pattern of aneurysm morphology than American patients of similar age. This difference may, in part, explain variability in the application of EVAR.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reino Unido , Estados Unidos
13.
J Vasc Surg ; 55(2): 318-25, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22047829

RESUMO

PURPOSE: Some patients with aortic arch or descending thoracic aorta pathologies are not suited for open repair because of comorbidities that may increase their risk of procedural complications or death. Endovascular approaches may also be difficult when there are inadequate proximal landing zones in the aortic arch. We report our experience using rerouting techniques with bypass, stenting of the branches, or a combination of both to create a landing area in zones 0 and 1 of the aortic arch. METHODS: Since November 2002, thoracic aortic endoluminal grafts were placed in 38 patients in whom the endograft was deployed in zone 0 (n = 27) or zone 1 (n = 11). A retrospective review is included. RESULTS: There were 11 women and 27 men with a mean age of 65.4 years (range 38-88). Aortic pathology included 12 Stanford type A dissections, 10 aortic arch aneurysms, 8 Stanford type B dissections, 3 descending thoracic aortic aneurysms, 2 aortobronchial fistulas, 1 innominate artery aneurysm and 2 aortic arch pseudoaneurysms. In zone 0, 21 had thoracic debranching with an ascending bypass, three patients had a remote-inflow and three patients had a chimney-stent with carotid-carotid bypass. In zone 1, five patients had a carotid-carotid bypass, one patient had an aortic to left common carotid artery (LCCA) bypass and five patients had chimney-stent on the LCCA. Fifty-eight percent of the patients were symptomatic and 26% emergent. Three patients required hemodialysis postoperatively (7.9%), 18 patients (47.4%) required prolonged mechanical ventilation for respiratory insufficiency. Paraplegia occurred in one patient (2.7%), and five patients suffered a cerebrovascular accident (13.1%). There were four early type I and two type II endoleaks. Overall 30-day mortality was 23.7%. CONCLUSIONS: The hybrid approach for repair of the aortic arch pathologies is feasible in patients unfit for open repair. We present the results of performing different techniques to treat the aortic arch with hybrid repair with antegrade or retrograde inflow, stenting of the branches or a combination of both. Long-term results are unknown, and larger series results and comparative studies are needed to determine safety and efficacy.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Arizona , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
Ann Thorac Surg ; 90(5): 1716-20, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20971308

RESUMO

Traditional open surgical repair has proven to be an effective treatment for the management of primary and recurrent coarctation of the thoracic aorta. Potential complications at short-term and long-term follow-up have included recurrent coarctation, hypertension, premature coronary artery disease, cerebrovascular disease, and anastomotic pseudoaneurysm. Endovascular repair of recurrent coarctation of the thoracic aorta offers a less invasive treatment approach in potential high-risk surgical patients.


Assuntos
Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Adulto , Falso Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Feminino , Humanos , Recidiva
15.
Ann Thorac Surg ; 90(1): 78-82, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20609752

RESUMO

BACKGROUND: The objective of our study is to determine the feasibility of thoracic aortic endografting in octogenarians. METHODS: Between 2000 and 2006 a total of 504 consecutive patients from two high-volume institutions underwent thoracic endoluminal graft repair for various thoracic aortic pathologies. The following devices were used: Gore TAG (W.L. Gore, Flagstaff, AZ); Talent (Medtronic, Minneapolis, MN); and Zenith (Cook, Inc, Bloomington, IN). One hundred one (101 of 504; 20%) patients were octogenarians; 60 males (1.5:1, M:F) with a mean age of 83.7 years. Indications for intervention included the following: atherosclerotic aneurysms, 75 (75 of 101, 74%); acute and chronic dissections, 11(11 of 101, 11%); penetrating aortic ulcers, 9 (9 of 101, 9%); contained ruptures, 5 (5 of 101, 5%); and 1 transection (1 of 101, 1%). Mean length of follow-up was 3.4 +/- 2.1 years. RESULTS: No intraoperative deaths were noted. Thirty-day mortality was 10% (10 of 101 patients) with an overall late mortality of 26.7% (27 of 101 patients). Mean hospital stay was 6.3 days. A total of 12 neurologic events were noticed: 2 paraplegia (2 of 101, 2%); 4 paraparesis (4 of 101, 4%), 3 with full recovery; and 6 (6 of 101, 6%) cerebrovascular accidents with full recovery in half. A total of 15 endoleaks (15 of 101, 15%) were seen and, in 11, interventions were required. CONCLUSIONS: Our data suggest that technical success is high and age-specific outcomes in this group of patients are favorable. Further studies are warranted.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Fatores Etários , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino
16.
Eur J Cardiothorac Surg ; 38(3): 305-10, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20304663

RESUMO

OBJECTIVE: Primary adult aortic coarctation (PAAC) is an unusual cause of hypertension. The standard of care includes surgical repair, which can be associated with considerable morbidity and operative risk. Although balloon angioplasty has been successfully used in paediatric and adolescent patients with coarctation, little information exists regarding the endovascular repair of PAAC. This study examines the procedural safety and efficacy of endovascular repair of PAAC along with midterm outcomes. METHODS: Between January 2000 and July 2008, 16 patients underwent endovascular repair of PAAC. All patients were hypertensive with 13 patients (81.3%) receiving medical therapy. Symptoms included chest pain (n=11, 69%), progressive fatigue (n=5, 31%), exercise intolerance (n=4, 25%) and shortness of breath (n=3, 19%). Associated cardiac concerns included depressed ejection fraction (n=6, 38%), pulmonary hypertension (n=5, 31%), ascending aortic dilatation (n=5, 31%) and bicuspid aortic valve (n=4, 25%). Endovascular repair was achieved using a percutaneous femoral approach. Balloon angioplasty of the coarctation was performed prior to treatment using a balloon-expandable uncovered stent. Aortic diameters were assessed using intravascular ultrasound. Pre- and post-procedure pressure gradients were measured and success was determined as a residual pressure gradient across the treated aorta of less than 20 mmHg. RESULTS: The male:female (M:F) ratio was 9:7 with a mean age of 39.7 years. Procedural success was 100%. Mean pre-procedural aortic diameter was 8.4mm (3-14 mm) and mean post-procedural aortic diameter was 16.3mm (10-20mm) (p=0.04). The mean pre-procedural pressure gradient was 48.3 mmHg (25-100 mmHg) and the mean post-procedural pressure gradient was 0.5 mmHg (0-15 mmHg) (p=0.05). Twelve patients received one stent, two patients received two stents, one patient received three stents and one other patient received a thoracic stent graft. The rate of paraplegia was 0% with no blood transfusions, strokes or deaths. Follow-up ranged from 12 to 72 months (mean=22.8 months). One patient required re-intervention with an additional stent 14 months following the initial procedure and all the patients remain symptom-free. CONCLUSION: Endovascular repair of PAAC is safe and effective and compares favourably with open surgical repair. Midterm follow-up suggests that the treatment is durable and may be an alternative to surgical repair. Although this is the largest endovascular treatment series for PAAC reported to date, additional study and follow-up are needed.


Assuntos
Coartação Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Adolescente , Adulto , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Feminino , Humanos , Hipertensão/etiologia , Masculino , Pessoa de Meia-Idade , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
17.
Eur J Cardiothorac Surg ; 37(2): 322-7, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19635674

RESUMO

OBJECTIVE: To determine the safety and effectiveness of current endovascular treatment in adult patients with thoracic aortic coarctation and its complications. METHODS: A cohort of 22 patients was treated for late presenting primary or recurrent coarctation or aneurysmal formation at varying intervals following childhood intervention. RESULTS: Ten patients with recently discovered de novo coarctations were treated with balloon-expandable stents, and an endoluminal graft (ELG) was used in one additional patient. In the other 11 patients with recurrent lesions, three underwent repeat balloon dilation and stenting; eight patients with recurrence with aneurysms received ELGs. The gradients across the coarctation decreased from 49 + 16 to 4 + 7 mmHg (p = 0.001), and the diameters increased from 10 + 4 to 19 + 4mm (p = 0.001). In five of the eight patients (63%) with aneurysms, the ELG covered the subclavian artery, and a carotid subclavian bypass was necessary. Two patients required iliac artery access. No early major complications occurred. At mean follow-up of 31 + 15.6 months, one patient with type II leak resolved spontaneously and another developed neck dilation and type I leak, requiring a second ELG placement. All patients except one had improvements in symptoms and better hypertension control. CONCLUSIONS: We conclude that primary or secondary endovascular intervention in adults with de novo or recurrent coarctation and aneurysms is feasible with good intermediate results.


Assuntos
Aorta Torácica/anormalidades , Coartação Aórtica/terapia , Adulto , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
18.
J Vasc Surg ; 50(6): 1255-64.e1-4, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19958982

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is applicable to a spectrum of thoracic aortic pathology with half of the procedures performed world-wide for indications other than degenerative aneurysm of the descending thoracic aorta (DTA). This multicenter, prospective study queried perioperative and one-year results of TEVAR using the commercially available GORE TAG device, in the treatment of acute complicated Type B dissection (cTBD), traumatic aortic tear (TT), and ruptured degenerative aneurysm (RDA) of the DTA. METHODS: This prospective, non-randomized, literature controlled study included 59 patients; cTBD, n = 19; RDA, n = 20; TT, n = 20. The primary end-point was the composite of death and total paraplegia in subjects at

Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Doença Aguda , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/etiologia , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/mortalidade , Ruptura Aórtica/etiologia , Ruptura Aórtica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Doença Catastrófica , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Razão de Chances , Paraplegia/etiologia , Estudos Prospectivos , Falha de Prótese , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/mortalidade , Reoperação , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
19.
Asian Cardiovasc Thorac Ann ; 17(6): 568-72, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20026530

RESUMO

Endografting, like open surgical repair of the thoracic aorta, can be complicated by paraplegia. We reviewed our thoracic endografting experience regarding the incidence and treatment of spinal cord neurologic events. Between February 2000 and July 2008, 346 patients underwent endoluminal grafting of the descending thoracic aorta. Indications for intervention included atherosclerotic aneurysms (45.9%), acute and chronic dissections (31.5%), miscellaneous lesions (13.6%), and penetrating aortic ulcers (8.9%). Ten women and 4 men (4.0%), with a mean age of 71.3 years, developed either paraparesis (1.7%) or paraplegia (2.3%). Nine (64.3%) of these patients had an aneurysm, 4 (28.6%) had acute or chronic type B aortic dissection, and 1 (7.1%) had a penetrating aortic ulcer; 3 (21.4%) of them had previously undergone open abdominal aortic aneurysm repair, and 13 (92.9%) required coverage of more than 20 cm of the aorta. Cerebrospinal fluid drainage was instituted in 7/8 paraplegic patients. Eight (57.1%) of the 14 patients recovered fully, 2 (14.3%) experienced partial recovery, and 4 (28.6%) had significant neurological deficits. Paraplegia following thoracic endografting appears to be associated with female sex, long-segment coverage of the thoracic aorta, and aneurysmal disease.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Paraparesia/etiologia , Paraplegia/etiologia , Isquemia do Cordão Espinal/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/epidemiologia , Aortografia/métodos , Arizona/epidemiologia , Bases de Dados como Assunto , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Paraparesia/epidemiologia , Paraplegia/epidemiologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Isquemia do Cordão Espinal/epidemiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Úlcera/cirurgia , Adulto Jovem
20.
J Card Surg ; 24(2): 188-90, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19267829

RESUMO

BACKGROUND: The use of endoluminal grafts to treat thoracic aortic aneurysms has been associated with a decreased morbidity and mortality compared with open thoracic aortic aneurysm repair. High-risk surgical patients with ilio-femoral occlusive disease may not be amenable to general anesthesia and the construction of a retroperitoneal conduit. METHODS AND RESULTS: We report the use of a novel technique consisting of cracking and paving of the ilio-femoral vessels with balloon angioplasty, followed by deployment of an endoconduit to deliver an endoluminal graft under local sedation to treat a high-risk 80-year-old patient with a thoracic aneurysm. CONCLUSION: High-risk surgical patients with iliofemoral disease can undergo endoluminal graft therapy to threat thoracic aortic aneurysms.


Assuntos
Angioplastia com Balão , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Artéria Ilíaca/cirurgia , Doenças Vasculares Periféricas/cirurgia , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/patologia , Procedimentos Cirúrgicos Cardiovasculares , Humanos , Artéria Ilíaca/patologia , Masculino , Doenças Vasculares Periféricas/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA