Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Neuroimage ; 226: 117539, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33186723

RESUMO

Diffusion-weighted magnetic resonance imaging (dMRI) has found great utility for a wide range of neuroscientific and clinical applications. However, high-resolution dMRI, which is required for improved delineation of fine brain structures and connectomics, is hampered by its low signal-to-noise ratio (SNR). Since dMRI relies on the acquisition of multiple different diffusion weighted images of the same anatomy, it is well-suited for denoising methods that utilize correlations across the image series to improve the apparent SNR and the subsequent data analysis. In this work, we introduce and quantitatively evaluate a comprehensive framework, NOise Reduction with DIstribution Corrected (NORDIC) PCA method for processing dMRI. NORDIC uses low-rank modeling of g-factor-corrected complex dMRI reconstruction and non-asymptotic random matrix distributions to remove signal components which cannot be distinguished from thermal noise. The utility of the proposed framework for denoising dMRI is demonstrated on both simulations and experimental data obtained at 3 Tesla with different resolutions using human connectome project style acquisitions. The proposed framework leads to substantially enhanced quantitative performance for estimating diffusion tractography related measures and for resolving crossing fibers as compared to a conventional/state-of-the-art dMRI denoising method.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Conectoma/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Razão Sinal-Ruído
2.
Radiology ; 297(2): 304-312, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840468

RESUMO

Background Diffusion-weighted imaging (DWI) shows promise in detecting and monitoring breast cancer, but standard spin-echo (SE) echo-planar DWI methods often have poor image quality and low spatial resolution. Proposed alternatives include readout-segmented (RS) echo-planar imaging and axially reformatted (AR)-simultaneous multislice (SMS) imaging. Purpose To compare the resolution and image quality of standard SE echo-planar imaging DWI with two high-spatial-resolution alternatives, RS echo-planar and AR-SMS imaging, for breast imaging. Materials and Methods In a prospective study (2016-2018), three 5-minute DWI protocols were acquired at 3.0 T, including standard SE echo-planar imaging, RS echo-planar imaging with five segments, and AR-SMS imaging with four times slice acceleration. Participants were women undergoing breast MRI either as part of a treatment response clinical trial or undergoing breast MRI for screening or suspected cancer. A commercial breast phantom was imaged for resolution comparison. Three breast radiologists reviewed images in random order, including clinical images indicating the lesion, images with b value of 800 sec/mm2, and apparent diffusion coefficient (ADC) maps from the three randomly labeled DWI methods. Readers measured the longest dimension and lesion-average ADC on three DWI methods, reported measurement confidence, and rated or ranked the quality of each image. The scores were fit to a linear mixed-effects model with intercepts for reader and subject. Results The smallest feature (1 mm) was only detectible in a phantom on images from AR-SMS DWI. Thirty lesions from 28 women (mean age, 50 years ± 13 [standard deviation]) were evaluated. On the five-point Likert scale for image quality, AR-SMS imaging scored 1.31 points higher than SE echo-planar imaging and 0.74 points higher than RS echo-planar imaging, whereas RS echo-planar imaging scored 0.57 points higher than SE echo-planar imaging (all P < .001). Conclusion The axially reformatted simultaneous multislice protocol was rated highest for image quality, followed by the readout-segmented echo-planar imaging protocol. Both were rated higher than the standard spin-echo echo-planar imaging. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Partridge in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Meios de Contraste , Imagem Ecoplanar/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
3.
Magn Reson Med ; 84(4): 1747-1762, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32115756

RESUMO

PURPOSE: In this study, we sought to develop a self-navigation strategy for improving the reconstruction of diffusion weighted 3D multishot echo planar imaging (EPI). We propose a method for extracting the phase correction information from the acquisition itself, eliminating the need for a 2D navigator, further accelerating the acquisition. METHODS: In-vivo acquisitions at 3T with 0.9 mm and 1.5 mm isotropic resolutions were used to evaluate the performance of the self-navigation strategy. Sensitivity to motion was tested using a large difference in pitch position of the head. Using a multishell diffusion weighted acquisition, tractography results were obtained at (0.9 mm)3 to validate the quality with conventional acquisition. RESULTS: The use of 3D multislab EPI with self-navigation enables 3D diffusion-weighted spin echo EPI acquisitions that have the same efficiency as 2D single-shot acquisition. For matched acquisition time the image signal-to-noise ratio (SNR) between 3D and 2D acquisition is shown to be comparable for whole-brain coverage with (1.5 mm)3 resolution and for (0.9 mm)3 resolution the 3D acquisition has higher SNR than what can be obtained with 2D acquisitions using current state-of-art multiband techniques. The self-navigation technique was shown to be stable under inter-volume motion. In tractography analysis, the higher resolution afforded by our technique enabled clear delineation of the tapetum and posterior corona radiata. CONCLUSION: The proposed self-navigation approach utilized a self-consistent phase in 3D diffusion weighted acquisitions. Its efficiency and stability were demonstrated for a plurality of common acquisitions. The proposed self-navigation approach allows for faster acquisition of 3D multishot EPI desirable for large field of view and/or higher resolution.


Assuntos
Imagem Ecoplanar , Interpretação de Imagem Assistida por Computador , Algoritmos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Reprodutibilidade dos Testes
4.
Magn Reson Med ; 83(6): 2209-2220, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31763730

RESUMO

PURPOSE: To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS: Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial b-value of 4000 s/mm2 , a radial b-value of 307 s/mm2 , and 64 diffusion encoding directions. This acquisition was then repeated with the radial b-value set to 0. A previously proposed theory was applied to these data in order to estimate the intra-axonal diffusivity and axonal water fraction for each WM voxel. Conventional single diffusion encoding data were also obtained with b-values of 1000 and 2000 s/mm2 , which provided additional information sufficient for determining both the intra-axonal and extra-axonal diffusion tensors. RESULTS: From the TDE data, the average intra-axonal diffusivity in WM was found to be 2.24 ± 0.18 µm2 /ms, and the average axonal water fraction was found to be 0.60 ± 0.11. From the 2 diffusion tensors, average WM values were estimated for several compartment-specific diffusion parameters. In particular, the extra-axonal mean diffusivity was 1.09 ± 0.19 µm2 /ms, the intra-axonal fractional anisotropy was 0.50 ± 0.14, and the extra-axonal fractional anisotropy was 0.23 ± 0.13. CONCLUSION: By using a simple TDE pulse sequence with an axially symmetric b-matrix, the diffusion tensors for the intra-axonal and extra-axonal spaces can be separately estimated in adult WM. This allows one to determine compartment-specific diffusion properties for these 2 water pools.


Assuntos
Substância Branca , Adulto , Anisotropia , Axônios , Difusão , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Substância Branca/diagnóstico por imagem
5.
PLoS One ; 5(12): e15710, 2010 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-21187930

RESUMO

Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report on a large reduction in EPI whole brain scan time at 3 and 7 Tesla, without significantly sacrificing spatial resolution, and while gaining functional sensitivity. The multiplexed-EPI (M-EPI) pulse sequence combines two forms of multiplexing: temporal multiplexing (m) utilizing simultaneous echo refocused (SIR) EPI and spatial multiplexing (n) with multibanded RF pulses (MB) to achieve m×n images in an EPI echo train instead of the normal single image. This resulted in an unprecedented reduction in EPI scan time for whole brain fMRI performed at 3 Tesla, permitting TRs of 400 ms and 800 ms compared to a more conventional 2.5 sec TR, and 2-4 times reductions in scan time for HARDI imaging of neuronal fibertracks. The simultaneous SE refocusing of SIR imaging at 7 Tesla advantageously reduced SAR by using fewer RF refocusing pulses and by shifting fat signal out of the image plane so that fat suppression pulses were not required. In preliminary studies of resting state functional networks identified through independent component analysis, the 6-fold higher sampling rate increased the peak functional sensitivity by 60%. The novel M-EPI pulse sequence resulted in a significantly increased temporal resolution for whole brain fMRI, and as such, this new methodology can be used for studying non-stationarity in networks and generally for expanding and enriching the functional information.


Assuntos
Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/metabolismo , Encéfalo/patologia , Mapeamento Encefálico/métodos , Difusão , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Biológicos , Neurônios/metabolismo , Imagens de Fantasmas , Análise de Regressão
6.
Magn Reson Med ; 63(2): 290-6, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20025068

RESUMO

A hybridized dual-imaging system combining real-time ultrasound imaging and MRI was utilized for cardiac imaging at 1.5 T and 3 T. The ultrasound scanner with a programmable software interface was connected via computer to the MRI scanner. Electronic noise was eliminated with electromagnetic shielding and grounding to the screen room. At 3 T, real-time prospective motion compensation in dynamic cine cardiac imaging was implemented using B-mode ultrasound imaging. The ultrasound technique avoided drawbacks such as signal saturation or steady-state interruption of the MR navigator gating. At 1.5 T, a low-latency real-time feedback to balanced steady state free precision MR imaging was performed in three normal volunteers. Results showed active tracking of the heart during respiratory motion and improvement in time-averaged cardiovascular images. Future studies can fully exploit the potential of the high-frequency position information provided by the ultrasound system for more advanced applications in real-time organ tracking.


Assuntos
Ecocardiografia/instrumentação , Coração/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória/instrumentação , Ultrassonografia/instrumentação , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Sensibilidade e Especificidade , Integração de Sistemas
SELEÇÃO DE REFERÊNCIAS