Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Neth Heart J ; 32(6): 245-253, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38713449

RESUMO

BACKGROUND: In refractory cardiogenic shock, temporary mechanical support (tMCS) may be crucial for maintaining tissue perfusion and oxygen delivery. tMCS can serve as a bridge-to-decision to assess eligibility for left ventricular assist device (LVAD) implantation or heart transplantation, or as a bridge-to-recovery. ECPELLA is a novel tMCS configuration combining venoarterial extracorporeal membrane oxygenation with Impella. The present study presents the clinical parameters, outcomes, and complications of patients supported with ECPELLA. METHODS: All patients supported with ECPELLA at University Medical Centre Utrecht between December 2020 and August 2023 were included. The primary outcome was 30-day mortality, and secondary outcomes were LVAD implantation/heart transplantation and safety outcomes. RESULTS: Twenty patients with an average age of 51 years, and of whom 70% were males, were included. Causes of cardiogenic shock were acute heart failure (due to acute coronary syndrome, myocarditis, or after cardiac surgery) or chronic heart failure, respectively 70 and 30% of cases. The median duration of ECPELLA support was 164 h (interquartile range 98-210). In 50% of cases, a permanent LVAD was implanted. Cardiac recovery within 30 days was seen in 30% of cases and 30-day mortality rate was 20%. ECPELLA support was associated with major bleeding (40%), haemolysis (25%), vascular complications (30%), kidney failure requiring replacement therapy (50%), and Impella failure requiring extraction (15%). CONCLUSION: ECPELLA can be successfully used as a bridge to LVAD implantation or as a bridge-to-recovery in patients with refractory cardiogenic shock. Despite a significant number of complications, 30-day mortality was lower than observed in previous cohorts.

2.
Int J Cardiol Heart Vasc ; 50: 101318, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38169976

RESUMO

Background: The aim of this study was to assess the prevalence of frailty and other impairments in potential left ventricular assist device (LVAD) and heart transplantation (HTx) candidates by performing a preoperative comprehensive geriatric assessment (CGA) and reviewing the treatment recommendations resulting from the CGA. Methods and results: This cross-sectional study included 73 patients aged ≥40 years who received a CGA as part of the patient selection procedure for LVAD and HTx. In every patient, a conclusion comprising frailty and other impairments was formulated based on the medical, mental, functional, and social domains and recommendations were made. The mean age was 58 years (range 40-71) and 70 % were male. In 97 % of patients, at least one impairment was identified by the CGA. The most common impairments were polypharmacy, high morbidity burden, reduced renal function, osteopenia, depression, poor quality of life, reduced functionality, (risk of) malnutrition, reduced grip strength and high caregiver burden. A small proportion of the potential LVAD and HTx candidates were frail (7 % according to Fried's frailty criteria, 6 % according to the Edmonton Frail Scale) and 39 % were pre-frail. The domains for which most impairments were found and the domains for which most treatment recommendations were given matched well, with the functional domain as the frontrunner. Conclusion: This study showed that most of the potential candidates for LVAD or HTx have impairments on at least one domain of the CGA. Impairments and associated risks can contribute to the decision making process for candidacy for LVAD and HTx.

4.
Res Pract Thromb Haemost ; 7(2): 100101, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37063754

RESUMO

Background: Continuous-flow left ventricular assist devices (CF-LVADs) are an established therapy for advanced heart failure. Thrombosis and hemorrhage are common complications after CF-LVAD implantation, which may be explained by device-induced platelet activation. Few data on the effect of CF-LVAD implantation on platelets are available to date. Objectives: The aim of this study was to characterize the change in the platelet activation status after CF-LVAD. Methods: Platelet phenotype and reactivity were determined with flow cytometry in 32 adults with end-stage heart failure before and 4 to 6 weeks after CF-LVAD implantation. Sixteen adults with a biological aortic valve prosthesis (AVP) using the same antiplatelet regimen were included to discriminate between the effects of CF-LVAD and the antiplatelet regimen. Plasma markers for platelet activation were determined with enzyme-linked immunosorbent assay. Results: Median (IQR) plasma levels of soluble P-selectin increased from 115.6 (79.1-142.7) ng/mL to 144.5 (100.4-197.5) ng/mL after CF-LVAD implantation (P < .001). Median (IQR) ß-thromboglobulin levels were 60.5 (37.8-81.5) ng/mL before implantation and remained high after LVAD implantation [60.0 (42.0-69.5) ng/mL]. The platelet P-selectin expression after stimulation with ADP (30 and 60 µM) or PAR1-activating peptide (12.5 and 25 µM) was reduced by 17% to 21%, and fibrinogen binding was reduced by 37% to 86%. Platelet responses to agonists were similar in patients with a CF-LVAD and patients with an AVP, except for fibrinogen binding in response to 12.5 µM PAR1-AP, which was lower in patients with a CF-LVAD (P < .001). Conclusions: Combined, these data provide evidence for systemic platelet activation and an acquired platelet disorder after CF-LVAD implantation. This might contribute to the risk of both hemorrhage and thrombosis associated with CF-LVADs.

5.
Artif Organs ; 47(7): 1192-1201, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37032516

RESUMO

BACKGROUND: Late right heart failure (LRHF) is a common complication during long-term left ventricular assist device (LVAD) support. We aimed to identify risk factors for LRHF after LVAD implantation. METHODS: Patients undergoing primary LVAD implantation between 2006 and 2019 and surviving the perioperative period were included for this study (n = 261). Univariate Cox proportional hazards analysis was used to assess the association of clinical covariates and LRHF, stratified for device type. Variables with p < 0.10 entered the multivariable model. In a subset of patients with complete echocardiography or right catheterization data, this multivariable model was extended. Postoperative cardiopulmonary exercise test data were compared in patients with and without LRHF. RESULTS: Nineteen percentage of patients suffered from LRHF after a median of 12 months, of which 67% required hospitalization. A history of atrial fibrillation (AF) (HR: 2.06 [1.08-3.93], p = 0.029), a higher preoperative body mass index (BMI) (HR: 1.07 [1.01-1.13], p = 0.023), and intensive care unit (ICU) duration (HR: 1.03 [1.00-1.06], p = 0.025) were independent predictors of LHRF in the multivariable model. A significant relation between the severity of tricuspid regurgitation (TR) and LRHF (HR: 1.91 [1.13-3.21], p = 0.016) was found in patients with echocardiographic data. Patients with LRHF demonstrated a lower maximal workload and peak VO2 at 6 months postoperatively. CONCLUSION: A history of AF, BMI, and longer ICU stay may help identify patients at high risk for LRHF. Severity of TR was significantly related to LRHF in a subset of patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Tricúspide , Humanos , Incidência , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Fatores de Risco , Coração Auxiliar/efeitos adversos
6.
ESC Heart Fail ; 10(3): 1656-1665, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36798028

RESUMO

AIMS: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. METHODS AND RESULTS: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P < 0.01) in 458 matched patients, with a median follow-up of 23 months. Within the matched cohort, HM3 patients had a median age of 58 years, and 83% were male, 80% of the HVAD patients were male, with a median age of 59 years. PS-adjusted Cox regression confirmed a significantly better survival for HM3 patients when compared with HVAD, with a HR of 1.46 (95% confidence interval 1.14-1.85, P < 0.01). Pump thrombosis (P < 0.01) and ischaemic stroke (P < 0.01) occurred less in HM3 patients. No difference was found for haemorrhagic stroke, right heart failure, driveline infection, and major bleeding. Landmark-analysis confirmed a significant difference in conditional survival >2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. CONCLUSIONS: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation.


Assuntos
Isquemia Encefálica , Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Isquemia Encefálica/complicações , Acidente Vascular Cerebral/epidemiologia , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Trombose/epidemiologia , Trombose/etiologia
7.
ASAIO J ; 69(5): 438-444, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730294

RESUMO

Thrombus formation is a common complication during left ventricular assist device (LVAD) therapy, despite anticoagulation with vitamin K antagonists (VKA) and a platelet inhibitor. Plasma levels of markers for primary and secondary hemostasis and contact activation were determined before LVAD implantation and 6 and 12 months thereafter in 37 adults with end-stage heart failure. Twelve patients received a HeartMate 3, 7 patients received a HeartWare, and 18 patients received a HeartMate II. At baseline, patients had elevated plasma levels of the platelet protein upon activation, ß-thromboglobulin, and active von Willebrand factor in thrombogenic state (VWFa), which remained high after LVAD implantation. Von Willebrand factor levels and VWF activity were elevated at baseline but normalized 12 months after LVAD implantation. High D -dimer plasma levels, at baseline, remained elevated after 12 months. This was associated with an increase in plasma thrombin-antithrombin-complex levels and plasma levels of contact activation marker-cleaved H-kininogen after LVAD implantation. Considering these results it could be concluded that LVAD patients show significant coagulation activation despite antithrombotic therapy, which could explain why patients are at high risk for LVAD-induced thrombosis. Continuous low-grade systemic platelet activation and contact activation may contribute to prothrombotic effects of LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Adulto , Humanos , Fator de von Willebrand/metabolismo , Coração Auxiliar/efeitos adversos , Hemostasia , Coagulação Sanguínea , Trombose/etiologia , Insuficiência Cardíaca/terapia
8.
Neth Heart J ; 31(5): 189-195, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36723773

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) therapy is an established treatment for advanced heart failure with reduced ejection fraction. We evaluated the characteristics and clinical outcomes of patients implanted with an LVAD in the Netherlands. METHODS: Patients implanted with an LVAD in the Netherlands between 2016 and 2020 were included in the analysis. Baseline characteristics entered into this registry, as well as clinical outcomes (death on device, heart transplantation) and major adverse events (device dysfunction, major bleeding, major infection and cerebrovascular event), were evaluated. RESULTS: A total of 430 patients were implanted with an LVAD; mean age was 55 ± 13 years and 27% were female. The initial device strategy was bridge to transplant (BTT) in 50%, destination therapy (DT) in 29% and bridge to decision (BTD) in the remaining 21%. After a follow-up of 17 months, 97 (23%) patients had died during active LVAD support. Survival was 83% at 1 year, 76% at 2 years and 54% at 5 years. Patients implanted with an LVAD as a BTT had better outcomes compared with DT at all time points (1 year 86% vs 72%, 2 years 83% vs 59% and 5 years 58% vs 33%). Major adverse events were frequently observed, most often major infection, major bleeding and cerebrovascular events (0.84, 0.33 and 0.09 per patient-year at risk, respectively) and were similar across device strategies. Patients supported with HeartMate 3 had a lower incidence of major adverse events. CONCLUSIONS: Long-term survival on durable LVAD support in the Netherlands is over 50% after 5 years. Major adverse events, especially infection and bleeding, are still frequently observed, but decreasing with the contemporary use of HeartMate 3 LVAD.

9.
Cardiovasc Revasc Med ; 50: 8-12, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36681530

RESUMO

OBJECTIVE: Periprocedural stroke during transcatheter aortic valve replacement (TAVR) is a highly feared adverse event. The TriGUARD 3 cerebral embolic protection device (CEPD) may have the potential benefit of reduction of embolic events, but it still remains unclear whether it reduces the incidence of periprocedural stroke or transient ischemic attack (TIA). We aimed to investigate whether the latest TriGUARD 3 CEPD reduces the incidence of clinically overt stroke within 72 h or at discharge after TAVR. METHODS: In this prospective single-center study 117 patients (mean age 80.3 years, 53.8 % male) were included from July 2020 to December 2021. RESULTS: The primary efficacy endpoint of this study, periprocedural clinically overt stroke or TIA, within 72 h or at discharge after TAVR with the TriGUARD 3 CEPD occurred in 1/117 pts (0.8 %). Secondary endpoints (device related issues such as life-threatening or disabling bleeding, acute kidney injury, major vascular complications) were reported in 4/117 pts (3.4 %). CONCLUSIONS: This study suggests that the use of the latest TriGUARD 3™ CEPD in transfemoral TAVR seems to be associated with a low rate of clinically overt stroke and a low rate of device related adverse events, reflecting "real world" TAVR practice. However these results should be hypothesis generating and confirmed in a large RCT.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
10.
Artif Organs ; 46(12): 2361-2370, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35920238

RESUMO

BACKGROUND: The life expectancy of patients with a continuous flow left ventricular assist device (cf-LVAD) is increasing. Adequate determination and regulation of mean arterial pressure (MAP) is important to prevent adverse events. Given the low pulsatility characteristics in these patients, standard blood pressure equipment is inadequate to monitor MAP and not recommended. We provide an overview of currently available noninvasive techniques, using an extensive search strategy in three online databases (Pubmed, Scopus and Google Scholar) to find validation studies using invasive intra-arterial blood pressure measurement as a reference. Mean differences with the reference values smaller than 5 ± 8 mm Hg were considered acceptable. OBSERVATIONS: After deduplication, screening, and exclusion of incorrect sources, eleven studies remained with 3139 successful MAP measurements in 386 patients. Four noninvasive techniques, using Doppler, pulse oximetry, finger cuff volume clamp, or slow upper arm cuff deflation, were identified and evaluated for validity and success rate in cf-LVAD patients. Here, a comprehensive technical background of the blood pressure measurement methods is provided in combination with a clinical use comparison. Of the reported noninvasive techniques, slow cuff devices performed most optimally (mean difference 1.3 ± 5.2 mm Hg). CONCLUSIONS: Our results are encouraging and indicate that noninvasive blood pressure monitoring options with acceptable validity and success rate are available. Further technical development and validation is warranted for the growing population of patients on long-term cf-LVAD support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Pressão Arterial , Determinação da Pressão Arterial/métodos , Artérias , Pressão Sanguínea/fisiologia
11.
ESC Heart Fail ; 8(3): 1796-1805, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33710786

RESUMO

AIMS: Mechanical circulatory support (MCS) results in substantial improvement of prognosis and functional capacity. Currently, duration of MCS as a bridge to transplantation (BTT) is often prolonged due to shortage of donor hearts. Because long-term results of exercise capacity after MCS are largely unknown, we studied serial cardiopulmonary exercise tests (CPETs) during the first year after MCS implantation. METHODS AND RESULTS: Cardiopulmonary exercise tests at 6 and 12 months after MCS implantation in BTT patients were retrospectively analysed, including clinical factors related to exercise capacity. A total of 105 MCS patients (67% male, 50 ± 12 years) underwent serial CPET at 6 and 12 months after implantation. Power (105 ± 35 to 114 ± 40 W; P ≤ 0.001) and peak VO2 per kilogram (pVO2/kg) improved significantly (16.5 ± 5.0 to 17.2 ± 5.5 mL/kg/min (P = 0.008)). Improvement in pVO2 between 6 and 12 months after LVAD implantation was not related to heart failure aetiology or haemodynamic severity prior to MCS. We identified maximal heart rate at exercise as an important factor for pVO2. Younger age and lower BMI were related to further improvement. At 12 months, 25 (24%) patients had a normal exercise capacity (Weber classification A, pVO2 > 20 mL/kg/min). CONCLUSIONS: Exercise capacity (power and pVO2) increased significantly between 6 and 12 months after MCS independent of Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile or heart failure aetiology. Heart rate at exercise importantly relates to exercise capacity. This long-term improvement in exercise capacity is important information for the growing group of long-term MCS patients as this is critical for the quality of life of patients.


Assuntos
Transplante de Coração , Coração Auxiliar , Tolerância ao Exercício , Feminino , Humanos , Masculino , Qualidade de Vida , Estudos Retrospectivos , Doadores de Tecidos
12.
ESC Heart Fail ; 8(2): 1596-1603, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33635573

RESUMO

AIMS: Left ventricular assist device therapy has become the cornerstone in the treatment of end-stage heart failure and is increasingly used as destination therapy next to bridge to transplant or recovery. HeartMate 3 (HM3) and HeartWare (HVAD) are centrifugal continuous flow devices implanted intrapericardially and most commonly used worldwide. No randomized controlled trials have been performed yet. Analysis based on large registries may be considered as the best alternative but has the disadvantage of different standard of care between centres and missing data. Bias is introduced, because the decision which device to use was not random, even more so because many centres use only one type of left ventricular assist device. Therefore, we performed a propensity score (PS)-based analysis of long-term clinical outcome of patients that received HM3 or HVAD in a single centre. METHODS AND RESULTS: Between December 2010 and December 2019, 100 patients received HVAD and 81 patients HM3 as primary implantation at the University Medical Centre Utrecht. We performed PS matching with an extensive set of covariates, resulting in 112 matched patients with a median follow-up of 28 months. After PS matching, survival was not significantly different (P = 0.21) but was better for HM3. The cumulative incidences for haemorrhagic stroke (P = 0.01) and pump thrombosis (P = 0.02) were significantly higher for HVAD patients. The cumulative incidences for major bleeding, ischaemic stroke, right heart failure, and driveline infection were not different between the groups. We found no interaction between the surgeon who performed the implantation and survival (P = 0.59, P = 0.78, and P = 0.89). Sensitivity analysis was performed, by PS matching without patients on preoperative temporary support resulting in 74 matched patients. This also resulted in a non-significant difference in survival (P = 0.07). The PS-adjusted Cox regression showed a worse but non-significant (P = 0.10) survival for HVAD patients with hazard ratio 1.71 (95% confidence interval 0.91-3.24). CONCLUSIONS: Survival was not significantly different between both groups after PS matching, but was better for HM3, with a significantly lower incidence of haemorrhagic stroke and pump thrombosis for HM3. These results need to be interpreted carefully, because matching may have introduced greater imbalance on unmeasured covariates. A multicentre approach of carefully selected centres is recommended to enlarge the number of matched patients.


Assuntos
Isquemia Encefálica , Coração Auxiliar , Acidente Vascular Cerebral , Humanos , Pontuação de Propensão , Estudos Retrospectivos
13.
Artif Organs ; 42(10): 983-991, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29675919

RESUMO

Infection of the driveline or pump pocket is a common complication in patients with ventricular assist devices (VADs) and Staphylococcus aureus is the main pathogen causing such infections. Limited evidence is currently available to guide the choice of antibiotic therapy and the duration of treatment in these patients. Patients at the University Medical Center Utrecht who developed a VAD-related S. aureus infection between 2007 and 2016 were retrospectively assessed. Blood culture isolates were typed by whole genome sequencing to differentiate between relapses and reinfections, and to determine whether antibiotic therapy had led to acquisition of resistance mutations. Twenty-eight patients had S. aureus VAD infections. Ten of these patients also suffered S. aureus bacteremia. Discontinuation of antibiotic therapy was followed by relapse in 50% of the patients without prior S. aureus bacteremia and in 80% of patients with bacteremia. Oral cephalexin could ultimately suppress the infection for the duration of follow-up in 8/8 patients without S. aureus bacteremia and in 3/6 patients with S. aureus bacteremia. Clindamycin failed as suppressive therapy in 4/4 patients. Cephalexin appears an adequate choice for antibiotic suppression of VAD infections with methicillin-susceptible S. aureus. In patients without systemic symptoms, it may be justified to attempt to stop therapy after treatment of the acute infection, but antibiotic suppression until heart transplant seems indicated in patients with S. aureus bacteremia.


Assuntos
Antibacterianos/uso terapêutico , Coração Auxiliar/microbiologia , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/efeitos dos fármacos , Adolescente , Adulto , Idoso , Bacteriemia/tratamento farmacológico , Bacteriemia/etiologia , Cefalexina/uso terapêutico , Clindamicina/uso terapêutico , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Filogenia , Infecções Relacionadas à Prótese/etiologia , Infecções Estafilocócicas/etiologia , Staphylococcus aureus/genética , Adulto Jovem
14.
Eur J Clin Invest ; 48(3)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29325227

RESUMO

BACKGROUND: The interleukin-33 (IL-33)/suppressor of tumorigenicity 2 (ST2) pathway is suggested to play an important role in fibrosis, remodelling and the progression of heart failure (HF). Increased soluble (sST2) levels are associated with adverse outcome in the average HF population. Less is known about sST2 levels in end-stage HF. Therefore, we studied sST2 levels in end-stage HF and the effect of unloading by left ventricular assist device (LVAD) support on sST2 levels. METHOD AND RESULTS: Serial plasma measurements of sST2 were performed pre-implantation and 1, 3 and 6 months after (LVAD) implantation in 38 patients. sST2 levels were elevated in end-stage HF just prior to LVAD implantation (74.2 ng/mL [IQR 54.7-116.9]; normal <35 ng/mL) and decreased substantially during LVAD support, to 29.5 ng/mL [IQR 24.7-46.6](P < .001). Patients with INTERMACS profile I had significantly higher sST2 levels compared to patients in profile II and profile III. A moderate correlation was found between sST2 and C-reactive protein (r = .580, P < .010). CONCLUSION: Levels of sST2 are elevated in end-stage HF patients with variability that suggests multiple inputs to a pro-inflammatory and pro-fibrotic pathway. Cardiogenic shock and increased C-reactive protein levels are associated with higher sST2 levels. LVAD support results in a significant drop in sST2 levels with normalization within 3 months postimplantation. This suggests that LVAD support leads to lessening of fibrosis and inflammation, which might eventually be used to target medical policy: explantation of the LVAD versus permanent use or cardiac transplantation.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Proteína 1 Semelhante a Receptor de Interleucina-1/metabolismo , Adolescente , Adulto , Idoso , Biomarcadores/metabolismo , Proteína C-Reativa/metabolismo , Feminino , Insuficiência Cardíaca/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Circ Cardiovasc Interv ; 8(6): e002408, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26033967

RESUMO

BACKGROUND: The new balloon-expandable Sapien 3 transcatheter heart valve (S3-THV) incorporates new features to reduce aortic regurgitation (AR) and vascular complications in transcatheter aortic valve implantation. Aim of this study is to compare the outcomes of the S3-THV with the preceding Sapien XT THV (SXT-THV) in patients who underwent transcatheter aortic valve implantation for symptomatic severe native aortic stenosis. METHODS AND RESULTS: Eligible patients were retrospectively identified in our institutional database and periprocedural clinical and imaging data were collected. Non-parsimonious one-to-many propensity score matching was performed to account for differences in baseline characteristics. Between November 2011 and December 2014, 167 patients underwent balloon-expandable transcatheter aortic valve implantation with either the S3-THV (n=49) or SXT-THV (n=118). Forty-four (89.8%) S3-THV patients were matched to 66 (55.9%) SXT-THV patients (mean age 80.3±8.4 and 80.5±7.8 years, median EuroSCORE 15.8 and 16.5%, respectively). In the S3-THV and SXT-THV groups, transfemoral approach (77.3% versus 78.8%) and postdilatation rates (15.9% versus 12.1%) were similar. Predischarge echocardiography demonstrated a lower incidence of ≥mild AR (15.9% versus 46.2%, P=0.003) for the S3-THV, despite reduced annulus area to prosthesis oversizing (8.2±5.1 versus 18.2±10.7%, P=0.001). Transfemoral access site-related life-threatening or major bleedings and vascular complications were absent in the S3-THV group (0% versus 7.7%, P=0.15). No differences were observed in pacemaker implantation rate (9.8% versus 8.8%, P=0.94) and 30-day mortality (both 5%). CONCLUSIONS: In this retrospective, propensity score-matched analysis, the S3-THV performed superiorly to the SXT-THV, as demonstrated by improved valve patency and increased transfemoral access safety.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Próteses Valvulares Cardíacas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pontuação de Propensão , Estudos Retrospectivos
18.
Front Surg ; 2: 10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25905105

RESUMO

Despite the improved treatment of cardiovascular diseases, the population with end-stage heart failure (HF) is progressively growing. The scarcity of the gold standard therapy, heart transplantation, demands novel therapeutic approaches. For patients awaiting transplantation, ventricular-assist devices have been of great benefit on survival. To allow explantation of the assist device and obviate heart transplantation, sufficient and durable myocardial recovery is necessary. However, explant rates so far are low. Combining mechanical circulatory support with regenerative therapies such as cell (-based) therapy and biomaterials might give rise to improved long-term results. Although synergistic effects are suggested with mechanical support and stem cell therapy, evidence in both preclinical and clinical setting is lacking. This review focuses on advanced and innovative strategies for the treatment of end-stage HF and furthermore appraises clinical experience with combined strategies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA