Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 23(13): 5943-5950, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37350548

RESUMO

Dynamics of optically excited plasmonic nanoparticles are presently understood as a series of scattering events involving the initiation of nanoparticle breathing oscillations. According to established models, these are caused by statistical heat transfer from thermalized electrons to the lattice. An additional contribution by hot-electron pressure accounts for phase mismatches between theory and experimental observations. However, direct experimental studies resolving the breathing-oscillation excitation are still missing. We used optical transient-absorption spectroscopy and time-resolved single-particle X-ray diffractive imaging to access the electron system and lattice. The time-resolved single-particle imaging data provided structural information directly on the onset of the breathing oscillation and confirmed the need for an additional excitation mechanism for thermal expansion. We developed a new model that reproduces all of our experimental observations. We identified optically induced electron density gradients as the initial driving source.

2.
Radiat Oncol ; 18(1): 2, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36600254

RESUMO

BACKGROUND: Stereotactic radiosurgery (SRS) is the preferred treatment for vestibular schwannoma (VS) in patients with preserved hearing and tumour diameter < 3 cm. Emerging evidence suggests restricting cochlear dose could preserve hearing. This retrospective replanning study aims to compare dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans for superiority of cochlear dose sparing without compromising tumour coverage. METHODS: Eligibility criteria included sporadic VS, serviceable hearing and availability of CT and MRI for planning. The original gross tumour volume and brainstem OAR volume were retained; the cochlea was newly contoured on the planning CT scan (bone window). Each case was replanned using the three above techniques, prescribing 12 Gy to the 80% isodose line. No dose constraint was applied to the cochlea. RESULTS: Eighteen patients were replanned. Mean tumour volume was 2.25 cc. Tumour coverage and tumour mean dose (DCAT: 14.2, IMRT: 14.6, VMAT: 14.5 Gy) were comparable. Paddick and RTOG conformity indices were better for DCAT (0.66 and 1.6) and VMAT (0.69 and 1.5) compared to IMRT (0.56 and 1.9). DCAT had superior gradient index (3.0) compared to VMAT (3.4) and IMRT (3.4). VMAT delivered the lowest mean brainstem maximum dose (8.3 Gy) and decreased the mean cochlear dose (3.4 Gy) by 2.3 and 2.1 Gy, and the mean cochlear maximum dose (3.6 Gy) by 2.4 and 2.5 Gy relative to DCAT and IMRT, respectively. CONCLUSION: LINAC-based SRS treatment using VMAT can achieve better cochlear dose sparing than DCAT or IMRT while maintaining tumour coverage.


Assuntos
Neuroma Acústico , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Radiocirurgia/métodos , Neuroma Acústico/radioterapia , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
3.
Phys Chem Chem Phys ; 24(38): 23096-23105, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-35876592

RESUMO

We investigated the dissociation of dications and trications of three polycyclic aromatic hydrocarbons (PAHs), fluorene, phenanthrene, and pyrene. PAHs are a family of molecules ubiquitous in space and involved in much of the chemistry of the interstellar medium. In our experiments, ions are formed by interaction with 30.3 nm extreme ultraviolet (XUV) photons, and their velocity map images are recorded using a PImMS2 multi-mass imaging sensor. Application of recoil-frame covariance analysis allows the total kinetic energy release (TKER) associated with multiple fragmentation channels to be determined to high precision, ranging 1.94-2.60 eV and 2.95-5.29 eV for the dications and trications, respectively. Experimental measurements are supported by Born-Oppenheimer molecular dynamics (BOMD) simulations.

4.
Commun Chem ; 5(1): 42, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36697752

RESUMO

Inner-shell photoelectron spectroscopy provides an element-specific probe of molecular structure, as core-electron binding energies are sensitive to the chemical environment. Short-wavelength femtosecond light sources, such as Free-Electron Lasers (FELs), even enable time-resolved site-specific investigations of molecular photochemistry. Here, we study the ultraviolet photodissociation of the prototypical chiral molecule 1-iodo-2-methylbutane, probed by extreme-ultraviolet (XUV) pulses from the Free-electron LASer in Hamburg (FLASH) through the ultrafast evolution of the iodine 4d binding energy. Methodologically, we employ electron-ion partial covariance imaging as a technique to isolate otherwise elusive features in a two-dimensional photoelectron spectrum arising from different photofragmentation pathways. The experimental and theoretical results for the time-resolved electron spectra of the 4d3/2 and 4d5/2 atomic and molecular levels that are disentangled by this method provide a key step towards studying structural and chemical changes from a specific spectator site.

5.
J Synchrotron Radiat ; 25(Pt 5): 1517-1528, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30179193

RESUMO

Extreme ultraviolet (XUV) and X-ray free-electron lasers enable new scientific opportunities. Their ultra-intense coherent femtosecond pulses give unprecedented access to the structure of undepositable nanoscale objects and to transient states of highly excited matter. In order to probe the ultrafast complex light-induced dynamics on the relevant time scales, the multi-purpose end-station CAMP at the free-electron laser FLASH has been complemented by the novel multilayer-mirror-based split-and-delay unit DESC (DElay Stage for CAMP) for time-resolved experiments. XUV double-pulses with delays adjustable from zero femtoseconds up to 650 picoseconds are generated by reflecting under near-normal incidence, exceeding the time range accessible with existing XUV split-and-delay units. Procedures to establish temporal and spatial overlap of the two pulses in CAMP are presented, with emphasis on the optimization of the spatial overlap at long time-delays via time-dependent features, for example in ion spectra of atomic clusters.

6.
J Synchrotron Radiat ; 25(Pt 5): 1529-1540, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30179194

RESUMO

The non-monochromatic beamline BL1 at the FLASH free-electron laser facility at DESY was upgraded with new transport and focusing optics, and a new permanent end-station, CAMP, was installed. This multi-purpose instrument is optimized for electron- and ion-spectroscopy, imaging and pump-probe experiments at free-electron lasers. It can be equipped with various electron- and ion-spectrometers, along with large-area single-photon-counting pnCCD X-ray detectors, thus enabling a wide range of experiments from atomic, molecular, and cluster physics to material and energy science, chemistry and biology. Here, an overview of the layout, the beam transport and focusing capabilities, and the experimental possibilities of this new end-station are presented, as well as results from its commissioning.

7.
Phys Med Biol ; 63(4): 045019, 2018 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-29363617

RESUMO

Three dimensional dosimetry by optical CT readout of radiosensitive gels or solids has previously been indicated as a solution for measurement of radiotherapy 3D dose distributions. The clinical uptake of these dosimetry methods has been limited, partly due to impracticalities of the optical readout such as the expertise and labour required for refractive index fluid matching. In this work a fast laser beam optical CT scanner is described, featuring fluid-less and dual wavelength operation. A second laser with a different wavelength is used to provide an alternative reference scan to the commonly used pre-irradiation scan. Transmission data for both wavelengths is effectively acquired simultaneously, giving a single scan process. Together with the elimination of refractive index fluid matching issues, scanning practicality is substantially improved. Image quality and quantitative accuracy were assessed for both dual and single wavelength methods. The dual wavelength scan technique gave improvements in uniformity of reconstructed optical attenuation coefficients in the sample 3D volume. This was due to a reduction of artefacts caused by scan to scan changes. Optical attenuation measurement accuracy was similar for both dual and single wavelength modes of operation. These results established the basis for further work on dosimetric performance.


Assuntos
Dosímetros de Radiação , Tomógrafos Computadorizados , Géis/efeitos da radiação , Humanos , Lasers , Doses de Radiação , Dosagem Radioterapêutica
8.
Phys Med Biol ; 63(4): 045020, 2018 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-29363619

RESUMO

New clinical radiotherapy dosimetry systems need comprehensive demonstration of measurement quality. Practicality and reliability are other important aspects for clinical dosimeters. In this work the performance of an optical CT scanner for true 3D dosimetry is assessed using a radiochromic gel dosimeter. The fluid-less scanner utilised dual lasers to avoid the necessity for pre-irradiation scans and give greater robustness of image quality, enhancing practicality. Calibration methods using both cuvettes and reconstructed volumes were developed. Dosimetric accuracy was similar for dual and single wavelength measurements, except that cuvette calibration reliability was reduced for dual wavelength without pre-irradiation scanning. Detailed performance parameters were specified for the dosimetry system indicating the suitability for clinical use. The most significant limitations of the system were due to the gel dosimeter rather than the optical CT scanner. Quality assurance guidelines were developed to maintain dosimetry system performance in routine use.


Assuntos
Dosímetros de Radiação/normas , Dosagem Radioterapêutica/normas , Tomógrafos Computadorizados/normas , Calibragem , Humanos , Lasers , Imagens de Fantasmas , Radiometria/métodos , Radiometria/normas , Reprodutibilidade dos Testes
9.
Phys Med Biol ; 57(12): 3853-68, 2012 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-22644104

RESUMO

Optical CT scanners for a 3D readout of externally irradiated radiosensitive hydrogels currently require the use of a refractive index (RI) matching liquid bath to obtain suitable optical ray paths through the gel sample to the detector. The requirement for a RI matching liquid bath has been negated by the design of a plastic cylindrical gel container that provides parallel beam geometry through the gel sample for the majority of the projection. The design method can be used for various hydrogels. Preliminary test results for the prototype laser beam scanner with ferrous xylenol-orange gel show geometric distortion of 0.2 mm maximum, spatial resolution limited to beam spot size of about 0.4 mm and 0.8% noise (1 SD) for a uniform irradiation. Reconstruction of a star pattern irradiated through the cylinder walls demonstrates the suitability for external beam applications. The extremely simple and cost-effective construction of this optical CT scanner, together with the simplicity of scanning gel samples without RI matching fluid increases the feasibility of using 3D gel dosimetry for clinical external beam dose verifications.


Assuntos
Ar , Fenômenos Ópticos , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Géis , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA