Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 10(4)2019 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-30935105

RESUMO

Soft, untethered microrobots composed of biocompatible materials for completing micromanipulation and drug delivery tasks in lab-on-a-chip and medical scenarios are currently being developed. Alginate holds significant potential in medical microrobotics due to its biocompatibility, biodegradability, and drug encapsulation capabilities. Here, we describe the synthesis of MANiACs-Magnetically Aligned Nanorods in Alginate Capsules-for use as untethered microrobotic surface tumblers, demonstrating magnetically guided lateral tumbling via rotating magnetic fields. MANiAC translation is demonstrated on tissue surfaces as well as inclined slopes. These alginate microrobots are capable of manipulating objects over millimeter-scale distances. Finally, we demonstrate payload release capabilities of MANiACs during translational tumbling motion.

2.
3.
PLoS One ; 12(8): e0183168, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28806768

RESUMO

OBJECTIVE: The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. MATERIALS AND METHODS: An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource). The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created) and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner. RESULTS: Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla) and the scattering parameter (measured using a network analyzer) were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer. CONCLUSION: The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Imagem Ecoplanar , Desenho de Equipamento , Cabeça , Humanos , Processamento de Imagem Assistida por Computador
4.
PLoS One ; 12(6): e0175629, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28662061

RESUMO

OBJECTIVE: The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. MATERIALS AND METHOD: A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization]. RESULTS: High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]-images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The proper digital palmar arteries and superficial palmar arch could also be clearly visualized using TOF nCE 7T MRI. CONCLUSION: Ultra-high resolution neurovascular imaging in upper extremities is possible at 7T without use of renal toxic intravenous contrast. 7T MRI can provide superior peripheral nerve [based on fiber anisotropy and diffusion coefficient parameters derived from diffusion tensor/spectrum imaging] and vascular [nCE MRA and vessel segmentation] imaging.


Assuntos
Imagem de Tensor de Difusão/métodos , Nervos Periféricos/diagnóstico por imagem , Feminino , Humanos , Masculino
5.
NMR Biomed ; 29(12): 1768-1779, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27809383

RESUMO

The purpose of this study is to develop and evaluate a custom-designed 7  T MRI coil and explore its use for upper extremity applications. An RF system composed of a transverse electromagnetic transmit coil and an eight-channel receive-only array was developed for 7  T upper extremity applications. The RF system was characterized and evaluated using scattering parameters and B1+ mapping. Finite difference time domain simulations were performed to evaluate the B1+ field distribution and specific absorption rate for the forearm region of the upper extremity. High-resolution 7  T images were acquired and compared with those at 3 T. The simulation and experimental results show very good B1+ field homogeneity across the forearm. High-resolution images of musculotendinous, osseocartilaginous, and neurovascular structures in the upper extremity are presented with T1 volumetric interpolated breath-hold examination, T2 double-echo steady state, T2 * susceptibility weighted imaging (SWI), diffusion tensor imaging, and time-of-flight sequences. Comparison between 3  T and 7  T is shown. Intricate contextual anatomy can be delineated in synovial, fibrocartilaginous, interosseous, and intraosseous trabecular structures of the forearm, as well as palmar and digital vascular anatomy (including microvascular detail in SWI). Ultra-high-field 7  T imaging holds great potential in improving the sensitivity and specificity of upper extremity imaging, especially in wrist and hand pathology secondary to bone, ligament, nerve, vascular, and other soft or hard tissue etiology.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Extremidade Superior/anatomia & histologia , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Magn Reson Med ; 74(5): 1461-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25367703

RESUMO

PURPOSE: To optimize the design of radiofrequency (RF) shielding of transmit coils at 7T and reduce eddy currents generated on the RF shielding when imaging with rapid gradient waveforms. METHODS: One set of a four-element, 2 × 2 Tic-Tac-Toe head coil structure was selected and constructed to study eddy currents on the RF coil shielding. The generated eddy currents were quantitatively studied in the time and frequency domains. The RF characteristics were studied using the finite difference time domain method. Five different kinds of RF shielding were tested on a 7T MRI scanner with phantoms and in vivo human subjects. RESULTS: The eddy current simulation method was verified by the measurement results. Eddy currents induced by solid/intact and simple-structured slotted RF shielding significantly distorted the gradient fields. Echo-planar images, B1+ maps, and S matrix measurements verified that the proposed slot pattern suppressed the eddy currents while maintaining the RF characteristics of the transmit coil. CONCLUSION: The presented dual-optimization method could be used to design RF shielding and reduce the gradient field-induced eddy currents while maintaining the RF characteristics of the transmit coil.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Encéfalo/anatomia & histologia , Simulação por Computador , Cobre , Campos Eletromagnéticos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Ondas de Rádio
SELEÇÃO DE REFERÊNCIAS