Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Minim Invasive Gynecol ; 24(1): 124-132, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27687851

RESUMO

STUDY OBJECTIVE: To assess the safety and effectiveness of the Minerva Endometrial Ablation System for the treatment of heavy menstrual bleeding in premenopausal women. DESIGN: Multicenter, randomized, controlled, international study (Canadian Task Force classification I). SETTING: Thirteen academic and private medical centers. PATIENTS: Premenopausal women (n = 153) suffering from heavy menstrual bleeding (PALM-COEIN: E, O). INTERVENTION: Patients were treated using the Minerva Endometrial Ablation System or rollerball ablation. MEASUREMENTS AND MAIN RESULTS: At 1-year post-treatment, study success (alkaline hematin ≤80 mL) was observed in 93.1% of Minerva subjects and 80.4% of rollerball subjects with amenorrhea reported by 71.6% and 49% of subjects, respectively. The mean procedure times were 3.1 minutes for Minerva and 17.2 minutes for rollerball. There were no intraoperative adverse events and/or complications reported. CONCLUSION: The results of this multicenter randomized controlled trial demonstrate that at the 12-month follow-up, the Minerva procedure produces statistically significantly higher rates of success, amenorrhea, and patient satisfaction as well as a shorter procedure time when compared with the historic criterion standard of rollerball ablation. Safety results were excellent and similar for both procedures.


Assuntos
Técnicas de Ablação Endometrial/efeitos adversos , Técnicas de Ablação Endometrial/métodos , Menorragia/cirurgia , Adulto , Feminino , Seguimentos , Humanos , Histeroscopia/efeitos adversos , Histeroscopia/métodos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Satisfação do Paciente , Pré-Menopausa , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
2.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26916197

RESUMO

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Assuntos
Biomarcadores/análise , Medicamentos Biossimilares/análise , Avaliação Pré-Clínica de Medicamentos/métodos , Biomarcadores/sangue , Registros Eletrônicos de Saúde , Laboratórios , Sociedades Médicas , Estudos de Validação como Assunto
3.
Bioanalysis ; 6(22): 2957-63, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25496252

RESUMO

The 8th GCC Closed Forum for Bioanalysis was held in Baltimore, MD, USA on 5 December 2013, immediately following the 2013 AAPS Workshop (Crystal City V): Quantitative Bioanalytical Methods Validation and Implementation--The 2013 Revised FDA Guidance. This GCC meeting was organized to discuss the contents of the draft revised FDA Guidance on bioanalytical method validation that was published in September 2013 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants, from seven countries, representing 46 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the draft FDA Guidance, and to build unified comments to be provided to the FDA.


Assuntos
Técnicas de Química Analítica/normas , Guias como Assunto , Estudos de Validação como Assunto , Biomarcadores/análise , Calibragem , Ligantes , Limite de Detecção , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA