1.
J Contemp Dent Pract ; 24(1): 56-60, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37189013

RESUMO

AIM: The aim of this study is to evaluate and compare the impact strength of conventional acrylic resin, high-impact acrylic resin, high-impact acrylic resin reinforced with silver nanoparticles, and high-impact acrylic resin reinforced with a zirconium oxide powder. MATERIALS AND METHODS: A total of 60 samples were prepared of dimensions 60 mm length × 7 mm width × 4 mm thickness to test impact strength. Machined stainless steel dies of the same dimension were used to form molds for the fabrication of these samples. Of 60 samples, 15 samples were prepared each from conventional acrylic resin (Group A1), high-impact acrylic resin (Group A2), acrylic resin reinforced with silver nanoparticles (Group A3), and acrylic resin reinforced with zirconium oxide powder (Group A4). Izod-Charpy pendulum impact testing machine was used. RESULTS: The impact strength of group A1 was in the range of 2.83-3.30 kJ/m2 (M = 3.12 kJ/m2, SD = 0.16), group A2 was in range of 5.10-5.78 kJ/m2 (M = 5.51 kJ/m2, SD = 0.18), group A3 was in range 3.18-3.56 kJ/m2 (M = 3.37 kJ/m2, SD = 0.11), and group A4 was in range 7.18-7.78 kJ/m2 (M = 7.5 kJ/m2, SD = 0.18). Statistical analysis using one-way ANOVA and t-test revealed significant differences (p < 0.001). CONCLUSION: High-impact acrylic resin reinforced with zirconium oxide powder has the highest impact strength. CLINICAL SIGNIFICANCE: This research sheds light on the usefulness of novel filler materials in clinical prosthodontics.


Assuntos
Resinas Acrílicas , Nanopartículas Metálicas , Pós , Prata , Polimetil Metacrilato , Bases de Dentadura , Teste de Materiais
2.
Semin Intervent Radiol ; 39(2): 192-193, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35781992
3.
Sensors (Basel) ; 21(16)2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34450839

RESUMO

Autonomous vehicles (AVs) rely on various types of sensor technologies to perceive the environment and to make logical decisions based on the gathered information similar to humans. Under ideal operating conditions, the perception systems (sensors onboard AVs) provide enough information to enable autonomous transportation and mobility. In practice, there are still several challenges that can impede the AV sensors' operability and, in turn, degrade their performance under more realistic conditions that actually occur in the physical world. This paper specifically addresses the effects of different weather conditions (precipitation, fog, lightning, etc.) on the perception systems of AVs. In this work, the most common types of AV sensors and communication modules are included, namely: RADAR, LiDAR, ultrasonic, camera, and global navigation satellite system (GNSS). A comprehensive overview of their physical fundamentals, electromagnetic spectrum, and principle of operation is used to quantify the effects of various weather conditions on the performance of the selected AV sensors. This quantification will lead to several advantages in the simulation world by creating more realistic scenarios and by properly fusing responses from AV sensors in any object identification model used in AVs in the physical world. Moreover, it will assist in selecting the appropriate fading or attenuation models to be used in any X-in-the-loop (XIL, e.g., hardware-in-the-loop, software-in-the-loop, etc.) type of experiments to test and validate the manner AVs perceive the surrounding environment under certain conditions.


Assuntos
Condução de Veículo , Automação , Humanos , Tecnologia , Meios de Transporte , Tempo (Meteorologia)
4.
Contemp Clin Dent ; 9(4): 587-591, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-31772468

RESUMO

BACKGROUND: Good adhesive bonding of restorative materials to cavity walls minimizing microleakage is an important criterion for the performance and longevity of a restoration in the oral cavity. The present study is aimed to compare the microleakage among newer composite materials. MATERIALS AND METHODS: Forty-five extracted healthy premolars were collected; standard Class II cavities were prepared. They were randomly divided into three groups of 15 teeth each. The groups were made based on the different composite restorative materials used for restoration. Group A consisted of conventional microfilled composite resin restorations, and Group B was posterior nanocomposite resin. Group C was restored using ORMOCER - Admira. After completion of restorations, all teeth were subjected to thermocycling at 5° C, 37° C, and 55° C for 250 cycles. Later, all samples were immersed into 50% silver nitrate dye group wise for for 4 hours (h), and teeth were sectioned buccolingually. Sectioned teeth were observed under a stereomicroscope for the evaluation of microleakage. ANOVA and unpaired t-tests were used for statistical analysis. The significance level was at set P < 0.001. RESULTS: The results of this study showed that Group C (ORMOCER - Admira) presented with the least microleakage followed by Group B (Tetric N-Ceram) followed by Group A (Tetric Ceram). CONCLUSIONS: Overall ORMOCER - Admira performed better than the other two composite materials with the least microleakage.

5.
N Engl J Med ; 377(23): 2240-2252, 2017 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-29211671

RESUMO

BACKGROUND: The post-thrombotic syndrome frequently develops in patients with proximal deep-vein thrombosis despite treatment with anticoagulant therapy. Pharmacomechanical catheter-directed thrombolysis (hereafter "pharmacomechanical thrombolysis") rapidly removes thrombus and is hypothesized to reduce the risk of the post-thrombotic syndrome. METHODS: We randomly assigned 692 patients with acute proximal deep-vein thrombosis to receive either anticoagulation alone (control group) or anticoagulation plus pharmacomechanical thrombolysis (catheter-mediated or device-mediated intrathrombus delivery of recombinant tissue plasminogen activator and thrombus aspiration or maceration, with or without stenting). The primary outcome was development of the post-thrombotic syndrome between 6 and 24 months of follow-up. RESULTS: Between 6 and 24 months, there was no significant between-group difference in the percentage of patients with the post-thrombotic syndrome (47% in the pharmacomechanical-thrombolysis group and 48% in the control group; risk ratio, 0.96; 95% confidence interval [CI], 0.82 to 1.11; P=0.56). Pharmacomechanical thrombolysis led to more major bleeding events within 10 days (1.7% vs. 0.3% of patients, P=0.049), but no significant difference in recurrent venous thromboembolism was seen over the 24-month follow-up period (12% in the pharmacomechanical-thrombolysis group and 8% in the control group, P=0.09). Moderate-to-severe post-thrombotic syndrome occurred in 18% of patients in the pharmacomechanical-thrombolysis group versus 24% of those in the control group (risk ratio, 0.73; 95% CI, 0.54 to 0.98; P=0.04). Severity scores for the post-thrombotic syndrome were lower in the pharmacomechanical-thrombolysis group than in the control group at 6, 12, 18, and 24 months of follow-up (P<0.01 for the comparison of the Villalta scores at each time point), but the improvement in quality of life from baseline to 24 months did not differ significantly between the treatment groups. CONCLUSIONS: Among patients with acute proximal deep-vein thrombosis, the addition of pharmacomechanical catheter-directed thrombolysis to anticoagulation did not result in a lower risk of the post-thrombotic syndrome but did result in a higher risk of major bleeding. (Funded by the National Heart, Lung, and Blood Institute and others; ATTRACT ClinicalTrials.gov number, NCT00790335 .).


Assuntos
Anticoagulantes/uso terapêutico , Síndrome Pós-Trombótica/prevenção & controle , Terapia Trombolítica/métodos , Ativador de Plasminogênio Tecidual/administração & dosagem , Trombose Venosa/tratamento farmacológico , Adulto , Anticoagulantes/efeitos adversos , Cateterismo Periférico , Feminino , Hemorragia/etiologia , Humanos , Incidência , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Síndrome Pós-Trombótica/epidemiologia , Síndrome Pós-Trombótica/etiologia , Proteínas Recombinantes/uso terapêutico , Fatores de Risco , Terapia Trombolítica/efeitos adversos , Ativador de Plasminogênio Tecidual/efeitos adversos , Trombose Venosa/complicações
6.
Indian J Psychiatry ; 58(1): 83-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26985110

RESUMO

Substance abuse is an important health problem throughout the world including India, but prevalence and pattern of abuse varies from country to country and in different types of population. Slums have their own social and economic problems so that substance abuse may be different in this population and might be related with these problems. The aim of the present study was to study the prevalence and pattern substances in slum population. Prakash Chandra Sethi Nagar slum area of Indore district was selected for the purpose of this study. In first phase of the study, first a camp was organized to sensitize local leaders, key persons, and local inhabitants about drug abuse at Chandra Prakash Sethi Nagar. After that basic information was gathered with the key persons in Chandra Prakash Sethi Nagar. In second phase by house-to-house survey, all members of the family were interviewed in detail and information was recorded on semi-structured proforma. We observed prevalence rate of 560/1000 populations, 78.2% were males, 28.2% were females, and two-third abusers were laborers (72%). In order of frequency, tobacco was the most common substance abused in 53.9% population followed by gutka (nontobacco pan masala). Other drugs in order of frequency were alcohol 46.5%, cannabis 8.9%, opiates 4.9%, sedative and hypnotic 2.0%, solvents 1.0%, and cocaine in 0.1%. Slum population has higher prevalence rates than general population.

8.
Emerg Radiol ; 12(1-2): 11-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16315059

RESUMO

The volume of critically ill patients requiring stabilization in emergency departments (EDs) throughout the USA has increased from 42 million per year in 1960 to over 92 million in 1990, as reported by Goldstein [Crit Care Clinics 21(1):81-89, 2005] and Rivers et al. [Curr Opin Crit Care 8(6):600-606, 2002]. With the increase in this patient population, the number of procedures, both invasive and noninvasive, performed in the ED to improve clinical outcomes has also increased. Therefore, emergency medicine physicians must add to their repertoire the ability to recognize potentially fatal traumatic complications. This review will provide readers with imaging findings of traumatic complications from placement of thoracic catheters and tubes and briefly discuss pitfalls of performing these procedures. In particular, complications arising from placement of hemodialysis catheters, central venous catheters, Swan-Ganz catheters, chest tubes, nasogastric and feeding tubes, and endotracheal tubes will be reviewed.


Assuntos
Cateteres de Demora/efeitos adversos , Estado Terminal , Intubação/efeitos adversos , Radiografia Torácica , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA