Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 199
Filtrar
1.
J Clin Med ; 13(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38999202

RESUMO

Transcatheter aortic valve implantation (TAVI) now represents the mainstay of treatment for severe aortic stenosis. Owing to its exceptional procedural efficacy and safety, TAVI has been extended to include patients at lower surgical risk, thus now encompassing a diverse patient population receiving this treatment. Yet, long-term outcomes also depend on optimal medical therapy for secondary vascular prevention, with antithrombotic therapy serving as the cornerstone. Leveraging data from multiple randomized controlled trials, the current guidelines generally recommend single antithrombotic therapy, with either single antiplatelet therapy (SAPT) or oral anticoagulation (OAC) alone in those patients without or with atrial fibrillation, respectively. Yet, individualization of this pattern, as well as specific case uses, may be needed based on individual patient characteristics and concurrent procedures. This review aims to discuss the evidence supporting antithrombotic treatments in patients treated with TAVI, indications for a standardized treatment, as well as specific considerations for an individualized approach to treatment.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38984656

RESUMO

More than mild paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) is associated with a twofold increase in all-cause mortality, heart failure hospitalizations, and the need for reintervention. Successfully addressing PVL in TAVIs is more challenging than in surgical valves. The arterial-arterial (A-A) rail technique emerges as a valuable strategy for post-TAVI PVL closure, enhancing success rates by enabling the effective use of lower-profile vascular plug devices. When standard approach is ineffective, generating an A-A loop for post-TAVI PVL closure is probably the most recommended strategy to ensure procedural success.

3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

4.
J Am Coll Cardiol ; 83(15): 1418-1430, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599718

RESUMO

During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence in patients with transcatheter-implanted valves. Significant microbiologic (molecular biology) and imaging diagnostic (fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography) advances have been incorporated into the 2023 Duke-International Society for Cardiovascular Infectious Diseases infective endocarditis diagnostic criteria, thus increasing the diagnostic sensitivity for PVE without sacrificing specificity in validation studies. PVE is a life-threatening disease requiring management by multidisciplinary endocarditis teams in cardiac centers to improve outcomes. Novel surgical options are now available, and an increasing set of patients may avoid surgical intervention despite indication. Selected patients may complete parenteral or oral antimicrobial treatment at home. Finally, patients with prosthetic valves implanted surgically or by the transcatheter approach are candidates for antibiotic prophylaxis before invasive dental procedures.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/terapia , Endocardite Bacteriana/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/diagnóstico , Endocardite/etiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
5.
J Invasive Cardiol ; 36(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38446025

RESUMO

OBJECTIVES: Valve oversizing has been associated with reduced paravalvular leaks (PVL) and valve migration risk. However, no optimal cut-off oversizing value has been defined for the Evolut system (Medtronic). The aim of this study was to assess the relationship between the degree of oversizing and moderate-to-severe PVL and determine the optimal oversizing cut-off value. METHODS: We conducted a multicenter study that included 740 consecutive patients with multidetector computed tomography (CT) data. Valve size was selected according to manufacturer recommendations, with oversizing ranging from 10% to 30%. The primary endpoint was moderate-to-severe PVL. RESULTS: The median age was 84 years (79-87 years), with 58.4% women, and a median EuroSCORE II of 4.1% (2.4-7.3%). Moderate-to-severe PVL was observed in 7.0% of the patients. An inverse relationship was found between oversizing and both PVL (11.3%, 8.6%, 5.4%, and 2.7% for quartiles Q1 to Q4; P = .007) and the need for post-dilation (P = .016). The multivariable analysis showed an association between oversizing and PVL (OR: 0.915 for each 1%-increase, P = .002). The optimal oversizing cut-off value to predict PVL was 20%, and PVL was significantly higher in patients with oversizing less than 20% (10.5% vs.4.2%, P less than .001). There were no differences in major clinical events according to the degree of oversizing, and a higher oversizing did not translate into an increased risk of permanent pacemaker (18.4% vs18.3%, P = .976). CONCLUSIONS: In TAVR with the Evolut valve, a higher oversizing was associated with lower rates of moderate-to-severe PVL and a lower need for post-dilation, with no negative impact on procedural and early clinical outcomes. A 20% oversizing threshold could be suggested to reduce PVLs. Further prospective studies are warranted to validate optimal oversizing for this valve system.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Seguimentos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/diagnóstico
7.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

8.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-37552784

RESUMO

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco
9.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
11.
Cardiovasc Revasc Med ; 60: 18-26, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37793964

RESUMO

AIM: To determine long-term survival of patients after cardiac arrest undergoing emergent coronary angiography and therapeutic hypothermia. METHODS: We analysed data from patients treated within the regional STEMI Network from January 2015 to December 2020. The primary endpoint was all-cause mortality at median follow-up. Secondary endpoints were periprocedural complications (arrhythmias, pulmonary edema, cardiogenic shock, mechanical complication, stent thrombosis, reinfarction, bleeding) and 6-month all-cause death. A landmark analysis was performed, studying two time periods; 0-6 months and beyond 6 months. RESULTS: From a total of 24,125 patients in the regional STEMI network, 494 patients who suffered from cardiac arrest were included and divided into two groups: treated with (n = 119) and without therapeutic hypothermia (n = 375). At median follow-up (16.0 [0.2-33.3] months), there was no difference in the adjusted mortality rate between groups (51.3 % with hypothermia vs 48.0 % without hypothermia; HRadj1.08 95%CI [0.77-1.53]; p = 0.659). There was a higher frequency of bleeding in the hypothermia group (6.7 % vs 1.1 %; ORadj 7.99 95%CI [2.05-31.2]; p = 0.002), without difference for the rest of periprocedural complications. At 6-month follow-up, adjusted all-cause mortality rate was similar between groups (46.2 % with hypothermia vs 44.5 % without hypothermia; HRadj1.02 95%CI [0.71-1.47]; p = 0.900). Also, no differences were observed in the adjusted mortality rate between 6 months and median follow-up (9.4 % with hypothermia vs 6.3 % without hypothermia; HRadj2.02 95%CI [0.69-5.92]; p = 0.200). CONCLUSIONS: In a large cohort of patients with cardiac arrest within a regional STEMI network, those treated with therapeutic hypothermia did not improve long-term survival compared to those without hypothermia.


Assuntos
Parada Cardíaca , Hipotermia , Parada Cardíaca Extra-Hospitalar , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angiografia Coronária , Resultado do Tratamento , Parada Cardíaca/diagnóstico , Parada Cardíaca/terapia
12.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38000627

RESUMO

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

13.
JACC Cardiovasc Interv ; 16(24): 3016-3023, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37902144

RESUMO

BACKGROUND: The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring. OBJECTIVES: This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures. METHODS: This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire. RESULTS: A total of 121 patients (mean age: 82.2 ± 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary efficacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 ± 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported. CONCLUSIONS: The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment. (SavvyWire Efficacy and Safety in Transcatheter Aortic Valve Implantation Procedures [SAFE-TAVI]; NCT05492383).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento
14.
JACC Cardiovasc Interv ; 16(24): 2999-3012, 2023 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-37902146

RESUMO

BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese
15.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704301

RESUMO

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Catéteres
16.
J Clin Med ; 12(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685589

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia worldwide. It is associated with increased mortality and morbidity, especially due to the increased risk of ischemic stroke and systemic embolism in these patients. For this reason, thromboembolism prevention is the cornerstone of managing AF, and oral anticoagulation is nowadays the first-line treatment. However, since most thrombi form in the left atrial appendage and anticoagulant therapy may have side effects and be contraindicated in some patients, surgical and percutaneous left atrial appendage occlusion (LAAO) have emerged as a non-pharmacological alternative. This review summarizes all existing evidence on surgical and percutaneous LAAO.

17.
Am J Cardiol ; 207: 114-120, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37734300

RESUMO

Paravalvular leak (PVL), conduction disturbances, and vascular complications remain the most common complications after TAVR. To address these adverse outcomes, the third generation of transcatheter heart valves has been developed. The last generation prosthesis provides an outer pericardial wrap for enhanced sealing and PVL prevention. This study aimed to compare the incidence and severity of PVL and 1-year survival after TAVR using SAPIEN 3 with those using EVOLUT PRO. An observational retrospective analysis was conducted in 1,481 patients who underwent TAVR for symptomatic severe aortic stenosis in 6 different European centers. The primary end point was to assess the frequency and severity of PVL at 30 days after TAVR. The secondary end point was to compare 1-year survival using EVOLUT PRO with that using SAPIEN 3. SAPIEN 3 transcatheter heart valve was implanted in 78.3% of study participants (n = 1,160) whereas EVOLUT PRO was implanted in 21.7% (n = 321). PVL is more commonly observed in patients treated with EVOLUT PRO at prehospital discharge (55.1% vs 37.3%) and at 1-month (51% vs 41.4%) and 1-year (51.3% vs 39.3%) follow-up. This difference mainly concerns low-grade (mild/trace) PVL. The frequency of high-degree (moderate/severe) PVL was almost similar in both groups throughout the study period (5.3% vs 5.8% before hospital discharge, 4% vs 3.1% at 1 month, and 3.2% vs 4.9% at 1 year). No significant difference in survival over 1 year has been observed (hazard ratio 0.73 [0.33 to 1.63], p = 0.442) (Graphical abstract). In conclusion, the detection rate of PVL after TAVR with third-generation heart valves remains high, and there are no major differences between the devices regarding the frequency of significant (moderate/severe) PVL and survival.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758382

RESUMO

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
19.
Catheter Cardiovasc Interv ; 102(4): 608-619, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37582340

RESUMO

BACKGROUND: Myocardial revascularization failure (MRF) and Secondary revascularization (SR) are contemporary interventional cardiology challenges. AIM: To investigate the characteristics, management, and prognosis of patients with myocardial revascularization failure (MRF) and need for secondary revascularization (SR) in contemporary practice. METHODS: The REVASEC study is a prospective registry (NCT03349385), which recruited patients with prior revascularization referred for coronary angiography at 19 centers. The primary endpoint is a patient-oriented composite (POCE) at 1 year, including death, myocardial infarction, or repeat revascularization. RESULTS: A total of 869 patients previously revascularized by percutaneous intervention (83%) or surgery (17%) were recruited. MRF was found in 83.7% (41.1% stent/graft failure, 32.1% progression of coronary disease, and 10.5% residual disease). SR was performed in 70.1%, preferably by percutaneous intervention (95%). The POCE rate at 1 year was 14% in the overall cohort, with 6.4% all-cause death. In the multivariate analysis, lower POCE rates were found in the groups without MRF (9.4%) and with disease progression (11%) compared with graft/stent failure (17%) and residual disease (18%), hazard ratio 0.67 (95% confidence interval: 0.45-0.99), p = 0.043. At 1 year, the SR group had less chronic persistent angina (19% vs. 34%, p < 0.001), but a higher rate of repeat revascularization (9% vs. 2.9%, p < 0.001). CONCLUSION: MRF was found in 84% of patients with prior revascularization referred for coronary angiography. Stent/graft failure and residual coronary disease were associated with a worse prognosis. SR provided better symptom control at the expense of a higher rate of new revascularization.

20.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA