Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 28(Pt 6): 1978-1984, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738953

RESUMO

The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10-5. The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information.

2.
Nat Commun ; 10(1): 4761, 2019 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-31628306

RESUMO

Stochastic processes are highly relevant in research fields as different as neuroscience, economy, ecology, chemistry, and fundamental physics. However, due to their intrinsic unpredictability, stochastic mechanisms are very challenging for any kind of investigations and practical applications. Here we report the deliberate use of stochastic X-ray pulses in two-dimensional spectroscopy to the simultaneous mapping of unoccupied and occupied electronic states of atoms in a regime where the opacity and transparency properties of matter are subject to the incident intensity and photon energy. A readily transferable matrix formalism is presented to extract the electronic states from a dataset measured with the monitored input from a stochastic excitation source. The presented formalism enables investigations of the response of the electronic structure to irradiation with intense X-ray pulses while the time structure of the incident pulses is preserved.

4.
Opt Lett ; 43(18): 4390-4393, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30211872

RESUMO

X-ray spectroscopy is a method, ideally suited for investigating the electronic structure of matter, which has been enabled by the rapid developments in light sources and instruments. The x-ray fluorescence lines of life-relevant elements such as carbon, nitrogen, and oxygen are located in the soft x-ray regime and call for suitable spectrometer devices. In this Letter, we present a high-resolution spectrum of liquid water, recorded with a soft x-ray spectrometer based on a reflection zone plate (RZP) design. The RZP-based spectrometer with meridional variation of line space density from 2953 to 3757 l/mm offers extremely high detection efficiency and, at the same time, medium energy resolution. We can reproduce the well-known splitting of liquid water in the lone pair regime with 10 s acquisition time.

5.
J Synchrotron Radiat ; 25(Pt 4): 1238-1248, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979187

RESUMO

The SwissFEL Aramis beamline, covering the photon energies between 1.77 keV and 12.7 keV, features a suite of online photon diagnostics tools to help both users and FEL operators in analysing data and optimizing experimental and beamline performance. Scientists will be able to obtain information about the flux, spectrum, position, pulse length, and arrival time jitter versus the experimental laser for every photon pulse, with further information about beam shape and size available through the use of destructive screens. This manuscript is an overview of the diagnostics tools available at SwissFEL and presents their design, working principles and capabilities. It also features new developments like the first implementation of a THz-streaking based temporal diagnostics for a hard X-ray FEL, capable of measuring pulse lengths to 5 fs r.m.s. or better.

6.
J Synchrotron Radiat ; 25(Pt 1): 16-19, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29271745

RESUMO

One of the remaining challenges for accurate photon diagnostics at X-ray free-electron lasers (FELs) is the shot-to-shot, non-destructive, high-resolution characterization of the FEL pulse spectrum at photon energies between 2 keV and 4 keV, the so-called tender X-ray range. Here, a spectrometer setup is reported, based on the von Hamos geometry and using elastic scattering as a fingerprint of the FEL-generated spectrum. It is capable of pulse-to-pulse measurement of the spectrum with an energy resolution (ΔE/E) of 10-4, within a bandwidth of 2%. The Tender X-ray Single-Shot Spectrometer (TXS) will grant to experimental scientists the freedom to measure the spectrum in a single-shot measurement, keeping the transmitted beam undisturbed. It will enable single-shot reconstructions for easier and faster data analysis.

7.
Struct Dyn ; 4(5): 054307, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28944255

RESUMO

X-ray absorption spectroscopy at the L-edge of 3d transition metals provides unique information on the local metal charge and spin states by directly probing 3d-derived molecular orbitals through 2p-3d transitions. However, this soft x-ray technique has been rarely used at synchrotron facilities for mechanistic studies of metalloenzymes due to the difficulties of x-ray-induced sample damage and strong background signals from light elements that can dominate the low metal signal. Here, we combine femtosecond soft x-ray pulses from a free-electron laser with a novel x-ray fluorescence-yield spectrometer to overcome these difficulties. We present L-edge absorption spectra of inorganic high-valent Mn complexes (Mn ∼ 6-15 mmol/l) with no visible effects of radiation damage. We also present the first L-edge absorption spectra of the oxygen evolving complex (Mn4CaO5) in Photosystem II (Mn < 1 mmol/l) at room temperature, measured under similar conditions. Our approach opens new ways to study metalloenzymes under functional conditions.

8.
Sci Rep ; 7(1): 8849, 2017 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-28821805

RESUMO

We have implemented and successfully tested an off-axis transmission Fresnel zone plate as spectral analyzer for resonant inelastic X-ray scattering (RIXS). The imaging capabilities of zone plates allow for advanced two-dimensional (2D) mapping applications. By varying the photon energy along a line focus on the sample, we were able to simultaneously record the emission spectra over a range of excitation energies. Moreover, by scanning a line focus across the sample in one dimension, we efficiently recorded RIXS spectra spatially resolved in 2D, increasing the throughput by two orders of magnitude. The presented scheme opens up a variety of novel measurements and efficient, ultra-fast time resolved investigations at X-ray Free-Electron Laser sources.

9.
Opt Express ; 25(10): 10984-10996, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28788785

RESUMO

We present a newly designed compact and flexible soft X-ray spectrometer for resonant inelastic X-ray scattering (RIXS) studies within an energy range from 380 eV to 410 eV, which would include the K alpha emission lines of vital elements like nitrogen. We utilized an off-axis reflection zone plate (RZP) as the wavelength selective element with a maximum line density of 10000 l/mm. A higher energy resolution over a broader range of ± 15 eV around the designed energy was achieved by displacing the RZP. Additionally, for the first time, an actual optical side effect, the so-called comatic aberration was exploited to increase the energy resolution. First results show a resolving power in the order of 1300 for photon energy of 395 eV, which is comparable to a commercial varied line spacing grating (VLS).

10.
Appl Opt ; 56(3): 515-520, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28157908

RESUMO

We simulate a proof-of-principle design of a wavelength dispersive, parallel spectrometer for use in resonant inelastic x-ray scattering (RIXS). The instrument relies on a multiple-channel reflection zone plate (RZP) array, enabling the recording of fluorescence spectra from an acceptance angle of 18 arc min×19 arc min with a mainly source-size-limited resolving power of (0.2-2.6)×104 over an energy range of 21 eV at the L-edge of Fe around 715 eV. An optimal two-dimensional signal readout preserves the spectral resolution to a large extent for widely open exit apertures of ≳50 mm2. The geometrical parameters are matched to the PEAXIS end station at the BESSY II synchrotron facility, and relaxed RZP line densities of <9×102 mm-1 assure the technical feasibility. An error budget estimation with respect to fabrication and alignment tolerances provides the link to real, RZP-based RIXS experiments in the future.

11.
Opt Express ; 24(20): 22469-22480, 2016 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-27828320

RESUMO

X-ray free electron lasers (XFELs) enable unprecedented new ways to study the electronic structure and dynamics of transition metal systems. L-edge absorption spectroscopy is a powerful technique for such studies and the feasibility of this method at XFELs for solutions and solids has been demonstrated. However, the required x-ray bandwidth is an order of magnitude narrower than that of self-amplified spontaneous emission (SASE), and additional monochromatization is needed. Here we compare L-edge x-ray absorption spectroscopy (XAS) of a prototypical transition metal system based on monochromatizing the SASE radiation of the linac coherent light source (LCLS) with a new technique based on self-seeding of LCLS. We demonstrate how L-edge XAS can be performed using the self-seeding scheme without the need of an additional beam line monochromator. We show how the spectral shape and pulse energy depend on the undulator setup and how this affects the x-ray spectroscopy measurements.

12.
Opt Lett ; 41(1): 29-32, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26696150

RESUMO

The feasibility of an off-axis x-ray reflection zone plate to perform wavelength-dispersive spectroscopy, on-axis point focusing, and two-dimensional imaging is demonstrated by means of one and the same diffractive optical element (DOE) at a synchrotron radiation facility. The resolving power varies between 3×101 and 4×102 in the range of 7.6 keV to 9.0 keV, with its maximum at the design energy of 8.3 keV. This result is verified using an adjustable entrance slit, by which horizontal (H) and vertical (V) focusing to 0.85 µm(H) and 1.29 µm(V) is obtained near the sagittal focal plane of the astigmatic configuration. An angular and axial scan proves an accessible field of view of at least 0.6 arcmin × 0.8 arcmin and a focal depth of ±0.86 mm. Supported by the grating efficiency of around 17.5% and a very short pulse elongation, future precision x-ray fluorescence and absorption studies of transition metals at their K-edge on an ultrashort timescale could benefit from our findings.

13.
Opt Express ; 22(10): 12583-602, 2014 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-24921376

RESUMO

In the present work, different varied line space (VLS) and reflection zone plate (RZP) gratings are analyzed for their suitability in low-signal femtosecond soft X-ray spectroscopy. The need for high efficiency suggests a straightened focal line whose sharpness and residual curvature will determine the quality. One- and two-dimensional VLS structures feature an attractive trade-off between a sufficient optical performance and a strongly relaxed fabrication, due to moderate line densities which are easily accessible by e-beam lithography. Based on fanned-out RZP arrays, their continuous limit version is identified to generate an almost perfect focal line however, with an aberration level three orders of magnitude better than for the VLS gratings and well below the diffraction limit over large acceptance angles.

14.
Philos Trans R Soc Lond B Biol Sci ; 369(1647): 20130590, 2014 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-24914169

RESUMO

X-ray free-electron lasers (XFELs) open up new possibilities for X-ray crystallographic and spectroscopic studies of radiation-sensitive biological samples under close to physiological conditions. To facilitate these new X-ray sources, tailored experimental methods and data-processing protocols have to be developed. The highly radiation-sensitive photosystem II (PSII) protein complex is a prime target for XFEL experiments aiming to study the mechanism of light-induced water oxidation taking place at a Mn cluster in this complex. We developed a set of tools for the study of PSII at XFELs, including a new liquid jet based on electrofocusing, an energy dispersive von Hamos X-ray emission spectrometer for the hard X-ray range and a high-throughput soft X-ray spectrometer based on a reflection zone plate. While our immediate focus is on PSII, the methods we describe here are applicable to a wide range of metalloenzymes. These experimental developments were complemented by a new software suite, cctbx.xfel. This software suite allows for near-real-time monitoring of the experimental parameters and detector signals and the detailed analysis of the diffraction and spectroscopy data collected by us at the Linac Coherent Light Source, taking into account the specific characteristics of data measured at an XFEL.


Assuntos
Elétrons , Lasers , Complexo de Proteína do Fotossistema II/química , Software , Espectrometria por Raios X/métodos , Difração de Raios X/métodos , Compostos de Manganês/química
15.
J Phys Chem Lett ; 4(21): 3641-3647, 2013 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-24466387

RESUMO

L-edge spectroscopy of 3d transition metals provides important electronic structure information and has been used in many fields. However, the use of this method for studying dilute aqueous systems, such as metalloenzymes, has not been prevalent because of severe radiation damage and the lack of suitable detection systems. Here we present spectra from a dilute Mn aqueous solution using a high-transmission zone-plate spectrometer at the Linac Coherent Light Source (LCLS). The spectrometer has been optimized for discriminating the Mn L-edge signal from the overwhelming O K-edge background that arises from water and protein itself, and the ultrashort LCLS X-ray pulses can outrun X-ray induced damage. We show that the deviations of the partial-fluorescence yield-detected spectra from the true absorption can be well modeled using the state-dependence of the fluorescence yield, and discuss implications for the application of our concept to biological samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA