1.
J Med Imaging (Bellingham) ; 11(3): 037001, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38765874

RESUMO

Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV). Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow. In-plane velocity vectors were measured with oPIV and ePIV. Flow was simulated with CFD using boundary conditions from ePIV and additional duplex-ultrasound (DUS) measurements. Mean differences and 95%-limits of agreement (1.96*SD) of the velocity magnitudes in space and time were compared, and the similarity of vector complexity (VC) and time-averaged wall shear stress (TAWSS) was assessed. Results: Similar flow features were observed between modalities with velocities up to 110 and 330 cm/s in the control and the stenosed model, respectively. Relative to oPIV, ePIV and CFD-ePIV showed negligible mean differences in velocity (<3 cm/s), with limits of agreement of ±25 cm/s (control) and ±34 cm/s (stenosed). CFD-DUS overestimated velocities with limits of agreements of 13±40 and 16.1±55 cm/s for the control and stenosed model, respectively. VC showed good agreement, whereas TAWSS showed similar trends but with higher values for ePIV, CFD-DUS, and CFD-ePIV compared to oPIV. Conclusions: EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.

2.
Ann Vasc Surg ; 106: 80-89, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38579908

RESUMO

BACKGROUND: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair using the Heli-FX EndoAnchor system. METHODS: This is a retrospective study of prospectively collected data from 9 vascular surgery departments between June 2010 and December 2019, including treated AAAs with neck lengths ≤10 mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. There were 2 Groups further assessed according to neck length, A (≥4 and <7 mm) and B (≥7 and ≤10 mm). The main outcomes analyzed were technical success, freedom from type Ia endoleaks (TIaELs), sac size increase, all-cause and aneurysm-related mortality. RESULTS: Seventy-six patients were included in the study, 17 fell into Group A and 59 into Group B. Median follow-up for the cohort was 40.5 (interquartile range 12-61) months. A median of 6 (interquartile range 3) EndoAnchors were deployed in each subject. Technical success was 86.8% for the total group, 82.4% and 88.1% (P = 0.534) for Groups A and B respectively. Six out of 10 (60%) of TIaELs at the completion angiographies showed spontaneous resolution. Cumulative freedom from TIaEL at 3 and 5 years for the total group was 89% and 84% respectively; this was 93% and 74% for Group A and 88% at both intervals in Group B (P = 0.545). In total, there were 7 (9.2%) patients presenting with TIaELs over the entire study period. Two (11.8%) in Group A and 5 (8.5%) in Group B (P = 0.679). There were more patients with sac regression in Group B (Group A = 6-35.3% vs. Group B = 34-57.6%, P = 0.230) with no statistical significance. All-cause mortality was 19 (25%) patients, with no difference (4-23.5% vs. 15-25.4%, P = 0.874) between groups; whereas aneurysm-related mortality occurred in 1 patient from Group A and 3 from Group B. CONCLUSIONS: This study demonstrates reasonable outcomes for patients with short-necked AAAs treated by endosutured aneurysm repair in terms of TIaELs up to 5-year follow-up. EndoAnchor use should be judiciously evaluated in short necks and may be a reasonable option when anatomical constraints are encountered, mainly for those with 7-10 mm neck lengths. Shorter neck length aspects, as indicated by the results from Group A, may be an alternative when no other options are available or feasible.

3.
J Endovasc Ther ; : 15266028241245602, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38590283

RESUMO

OBJECTIVE: To assess the impact of heparin-bonded endoprosthesis compared with femoropopliteal bypass on key hospital resources and revenues up to 1-year follow-up. DESIGN: A 2-arm scenario resource consumption data analysis was modeled based on a multicentre prospective randomized controlled trial. SETTING: Six centers in the Netherlands. PARTICIPANTS: A total of 100 patients were assigned to 2 arms (50 each arm). The first arm evaluated endovascular treatment using the heparin-bonded Viabahn endoprosthesis and the second the femoropopliteal bypass. Resource consumption rates were compared between arms. PRIMARY AND SECONDARY OUTCOMES MEASURES: Resource consumption rates, including hospital stay for bypass procedure, operating room time, type of anesthesia, number of used (endo)grafts, use of different types of bed locations (vascular ward, medium or intensive care), readmission for wound infections, and reinterventions over a period of 12 months. RESULTS: Endovascular repair used fewer hospital resources, with an overall difference of €149.983. Hospital stay was 118 days less (261 vs 379), including 21 fewer days in medium/intensive care (5 vs 26) and 50 fewer operating room hours (100 vs 150). Fewer patients required general anesthesia (31 vs 39), and there were less surgical site infections (3 vs 12). In the surgical bypass group, there were 18 fewer days of hospital stay related to reinterventions (80 vs 62), and the cost of the devices was €309.996, cheaper. The total monetary difference was € 160.013, in favor of the femoropopliteal bypass (€3.200, per patient). CONCLUSIONS: Endovascular repair of the superficial femoral artery reduces the use of valuable hospital resources. Its major limitation is the cost of the devices, which should be balanced against the reduction in peri-procedural morbidity and faster recovery. In the context of shortage of hospital beds, it offers capacity benefits, allowing for the treatment of more patients overall. These benefits may outweigh the fewer reinterventions in the surgical bypass group. REGISTRATION: The SuperB Trial was registered in clinicaltrials.gov; NCT-ID: NCT01220245. CLINICAL IMPACT: Modeling is a useful technique to predict the impact of treatment modalities on hospital resources and revenue. This study uses real-world data from the SuperB Trial to compare two treatment strategies of superficial femoral artery disease, reflecting actual clinical practice and patient outcomes. The analysis focused on direct costs associated with hospital resources and device usage without considering indirect costs or long-term cost-effectiveness. The analysis showed that endovascular repair reduces the use of valuable hospital resources. Its major limitation is device costs, which should be balanced against the reduction in peri-procedural morbidity and faster recovery. In the context of shortage of hospital beds, it offers capacity benefits, allowing for the treatment of more patients overall.

4.
J Vasc Surg ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604319

RESUMO

OBJECTIVE: In two randomized controlled trials, the outcomes of endovascular treatment of complex femoropopliteal arterial lesions were compared with bypass surgery and considered a valid alternative treatment. The aim of this study was to compare both endovascular treatment options with the hypothesis that implantation of heparin-bonded self-expanding covered stents (Viabahn [SECS]) or drug-eluting stents (ZilverPTX [DES]) are related to similar clinical outcomes at 1-year follow-up. METHODS: In a post-hoc analysis, the SuperB trial and Zilverpass databases were merged. Patients in the endovascular treatment arms were included, and data was analyzed in an intention-to-treat (ITT) and a per-protocol (PP) fashion. Data included baseline and lesion characteristics, procedural details, and follow-up data. The primary endpoint of this study was primary patency at 1-year follow-up. The secondary endpoints were secondary patency, target lesion revascularization (TLR), limb loss, and all-cause mortality. RESULTS: A total of 176 patients were included; 63 in the SECS arm and 113 in the DES arm. Through 1-year follow-up, there were no significant differences in primary patency (ITT: 63.4% vs 71.1%: P = .183 and PP: 60.8% vs 71.1%; P = .100). Secondary patency rates were not significantly different in the ITT analysis (86.5% vs 95.1%; P = .054), but in the PP analysis, there was a significant difference in favor of the DES group (SECS, 85.6% vs DES, 95.1%; P = .038). There was no significant difference in freedom from TLR between groups (79.6% vs 77.0%; P = .481). No major amputations were performed in the SECS group, and two were performed in the DES group (1.8%). Survival rate was 98.2% in the SECS group, and 91.3% in the DES group after 1-year follow-up (P = .106). Based on diagnosis (intermittent claudication vs chronic limb-threatening ischemia) no differences between patients with intermittent claudication and chronic limb-threatening ischemia were observed in primary patency, secondary patency and freedom from TLR. CONCLUSIONS: Treatment of complex femoropopliteal arterial disease with the heparin-bonded Viabahn endoprosthesis and the Zilver PTX drug-eluting stent are related to similar primary and secondary patency, and TLR rates at 1 year, except for secondary patency in the PP analysis. This study further supports the endovascular treatment of long complex lesions in the femoropopliteal artery.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38670221

RESUMO

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38527519

RESUMO

OBJECTIVE: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals. METHODS: A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter. RESULTS: Five hundred and fourteen patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at one year, 73.0% at five years, and 37.0% at 10 years, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. 37.9% were treated outside IFU, leading to significantly more re-interventions over 10 years compared with those treated inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at one year, 65.8% at five years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with one year sac growth had significantly worse survival (p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, type 1a endoleak occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients. CONCLUSION: This multicentre study of real world endovascular aneurysm repair data using the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and one year sac growth was associated with statistically significantly worse survival.

7.
J Endovasc Ther ; : 15266028241231520, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349021

RESUMO

OBJECTIVE: This study aims to compare the 5-year outcomes of endoluminal bypass (EB) using heparin-bonded self-expanding covered stents versus bypass surgery for extensive femoropopliteal disease, including technical and clinical outcomes and health status. BACKGROUND: The surgical femoropopliteal bypass was the gold standard to treat peripheral arterial disease (PAD) for decades; however, endovascular treatment modalities are now recommended for most femoropopliteal lesions. One-year data of a randomized controlled trial comparing EB with surgical bypass (SB) have shown a faster recovery, less morbidity, and comparable patency rates between the two techniques. To date, long-term randomized controlled data regarding both techniques are lacking. METHODS: Five-year results of a multicenter randomized controlled trial comparing EB with SB in patients with femoropopliteal artery disease were evaluated based on intention-to-treat and per-protocol analyses. RESULTS: At 5-year follow-up, primary, primary-assisted, and secondary patency rates were 36.2%, 52.4%, and 68.1% for EB and 49.4%, 72.2%, and 77.8% for SB, respectively (p=0.608). Freedom from target lesion revascularization (fTLR) was 34.1% for EB and 57.6% for SB (p=0.365). In both groups, the ankle-brachial index, Rutherford classification, and walking distance significantly improved compared with baseline without differences between groups at follow-up. Freedom from major amputation rate was 92.6% in the EB group and 96.2% in the SB group (p=0.361). The 36-Item Short-Form Health Survey showed no significant differences between groups. CONCLUSION: Treatment of extensive femoropopliteal disease with self-expanding covered stents provides comparable clinical-related and health-related questionnaire outcomes when compared with SB through 5 years of follow-up. However, the EB is related to a higher number of reinterventions. CLINICAL IMPACT: This present study is the first to report five-year outcomes comparing an endoluminal (EB) using heparin-bonded self-expanding covered stents with surgical bypass (SB) for long and complex femoropopliteal disease. Although the advantages of treatment with EB are mostly seen in the early period after treatment, the outcomes support the use of EB for this indication and seems to be a valid and safe alternative for bypass surgery. Future trials comparing various endovascular strategies may provide further guidance for the development of an evidence-based treatment algorithm.

8.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38185214

RESUMO

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Estudos Prospectivos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Seguimentos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco
9.
J Endovasc Ther ; : 15266028231224257, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38193446

RESUMO

OBJECTIVE: The upside-down configuration of a Gore Excluder contralateral leg endoprosthesis has been used to overcome diameter differences in the endovascular treatment of aortoiliac aneurysms. Our goal was not to describe the technique but to study the applicability and safety. MATERIAL AND METHODS: Patients were retrospectively enrolled. The indication and details of the procedure were at the discretion of the treating physicians. A case report form was completed including baseline characteristics, indication for treatment, procedural data, and outcomes during follow-up. RESULTS: A total of 31 subjects were enrolled with a range of indications, including 3 patients treated in the emergency setting (9.7%). In 64.5% (n=20), it was a primary intervention for a common iliac aneurysm (n=10), internal iliac aneurysm (n=4), or abdominal aortic aneurysm (n=6). In 11 subjects (35.5%), treatment was performed after previous aortoiliac interventions, including anastomotic iliac artery aneurysm (n=5), type III endoleak (n=3), and endograft thrombus (n=3). Median follow-up was 13 months (range=1-142 months). During follow-up, 2 patients required an upside-down contralateral leg-related secondary intervention, one for an occlusion and another for a type Ia endoleak. There was no type Ib or III endoleak, and no migration, kinking/stenosis, or conversion to open repair was observed. The aneurysm-related mortality was 3.3% (n=1). CONCLUSION: An upside-down contralateral leg is a valuable technique that can be used to achieve adequate aneurysm exclusion or resolve complications. It is associated with a limited number of complications. CLINICAL IMPACT: This article studies the use of an upside-down iliac endograft. We describe a wide range of indications in which this previously published technique has been applied. In elective and acute settings and as primary and revision intervention an upside-down iliac endograft was performed successfully. Furthermore, follow-up data is presented showing the effectiveness of the technique. Knowledge of this procedure is a valuable addition to the skillset of every interventionalist.

10.
J Vasc Surg ; 79(1): 24-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37734570

RESUMO

OBJECTIVE: Type II endoleak is the most frequent complication after endovascular abdominal aneurysm repair. Polytetrafluoroethylene and polyester (PE) are the two most commonly used graft materials in endovascular aneurysm repair (EVAR) devices. Biological properties of the material might influence the appearance and persistence of type II endoleak (T2EL). Therefore, the aim of this study was to evaluate potential differences in the prevalence of T2EL after EVAR between polytetrafluoroethylene (PTFE) and PE endografts in patients electively treated for an infrarenal abdominal aortic aneurysm. METHODS: A single-center, retrospective, observational study was conducted between January 2011 and January 2022. Preoperative, procedural, and follow-up data were derived from electronic health records. Imaging included computed tomography scans, and/or duplex ultrasound examination. The primary end point was the prevalence of T2EL diagnosed within 1 year after EVAR. Secondary end points included the prevalence of T2EL throughout follow-up, early (≤30 days) and late (>30 days) T2EL, the rate of T2EL disappearance during the follow-up period, the prevalence of type I and III endoleak, and T2EL-related reinterventions. RESULTS: Follow-up was available for 394 patients, 245 in the PE and 149 in the PTFE group. The prevalence of T2EL diagnosed within 1 year after endovascular repair was 11.8% in the PE group and 21.5% in the PTFE group (P = .010). There was no significant difference in early (≤30 days) and late (>30 days) T2EL between groups (P = .270 and P = .311). There was no difference in the freedom from endoleak type II reinterventions between groups (P = .877). CONCLUSIONS: The prevalence of T2EL after elective EVAR is significantly higher with the use of PTFE-based endografts compared with PE-based endografts. This difference is mostly based on T2EL diagnosed after 30 days of follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/epidemiologia , Endoleak/etiologia , Estudos Retrospectivos , Prevalência , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Politetrafluoretileno
11.
Cardiol Ther ; 13(1): 233-242, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38055176

RESUMO

INTRODUCTION: Cardiovascular diseases (CVD) are the leading cause of death globally. Inflammation is an important driver of CVD where tissue damage may lead to the formation of deadly thrombi. Therefore, antithrombotic drugs, such as platelet inhibitors, are crucial for secondary risk prevention in coronary artery disease (CAD) and peripheral artery disease (PAD). For severe forms of the disease, dual-pathway inhibition (DPI) where low-dose aspirin is combined with rivaroxaban has shown improved efficacy in reducing cardiovascular mortality. METHODS: Given this greater improvement in mortality, and the importance of inflammation in driving atherosclerosis, the potential for off-target inflammation-lowering effects of these drugs was evaluated by looking at the change in immune cell distribution and responsiveness to ex vivo lipopolysaccharide (LPS) stimulation after 3 months of DPI in patients with CAD. RESULTS: We observed no changes in whole blood or peripheral blood mononuclear cell (PBMC) immune cell responsiveness to LPS after 3 months of DPI. Additionally, we did not observe any changes in the distribution of total white blood cells, monocytes, neutrophils, lymphocytes, or platelets during the study course. Signs of systemic inflammation were studied using Olink proteomics in 33 patients with PAD after 3 months of DPI. No changes were observed in any of the inflammatory proteins measured after the treatment period, suggesting that the state of chronic inflammation was not altered in these subjects. CONCLUSION: Three months of DPI does not result in any meaningful change in immune cell responsiveness and distribution in patients with CAD or PAD. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT05210725.

12.
JMIR Res Protoc ; 12: e51480, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38048145

RESUMO

BACKGROUND: The recommendations for the use of and selection of covered stent grafts in patients with aortoiliac occlusive disease are limited. OBJECTIVE: The GORE VBX FORWARD clinical study aims to demonstrate the superiority of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX device) for primary patency when compared to bare metal stenting (BMS) for the treatment of complex iliac artery occlusive disease. METHODS: A prospective, multicenter, randomized control study in the United States, European Union, United Kingdom, Australia, and New Zealand will enroll patients with symptomatic, complex iliac artery occlusive disease. In this study, iliac artery occlusive disease is defined as a unilateral or bilateral disease with single or multiple lesions (with >50% stenosis or chronic total occlusion) each between 4 and 11 cm in length. In an attempt to more closely match real-world practices, patients with minor tissue loss (Rutherford class 5) and patients requiring hemodialysis will be included. Baseline aortoiliac angiography will be performed to assess target lesion characteristics and determine final patient eligibility. Once the patient is confirmed and guidewires are in place across the target lesions, the patient will be randomized in a 1:1 format to treatment with either the VBX device or a BMS. The BMS can be balloon- or self-expanding and must be approved for the iliac artery occlusive disease indication. Patients, the independent core laboratory reviewers, and Clinical Events Committee members will be blinded from the assigned treatment. Dual antithrombotic medical therapy is required through a minimum of 3 months post procedure. The primary end point is 12­month primary patency and will be adjudicated by an independent imaging core laboratory and Clinical Events Committee. Key secondary end points will be tested for superiority and include technical, acute procedural, and clinical success; changes in Ankle-brachial index; patient quality of life; primary patency; freedom from restenosis; primary-assisted patency; secondary patency; freedom from target lesion revascularizations; cumulative reintervention rate; amputation-free survival; survival; and change in Rutherford category. Study follow-up will continue through 5 years. RESULTS: Outcomes will be reported following study completion. Enrollment is anticipated to start in October 2023. CONCLUSIONS: The results of this study will provide definitive, level 1 clinical evidence to clinicians on the optimal choice of stent device to use for the treatment of complex iliac artery occlusive disease. The FORWARD study is powered for superiority and includes only complex, unilateral, or bilateral lesions involving the common or external iliac arteries. This study is a multidisciplinary endeavor involving vascular surgery, interventional cardiology, and interventional radiology across multiple countries with a blinded core laboratory review of end points in hopes that the outcomes will be widely accepted and incorporated into practice guidelines for optimal treatment of patients with complex iliac artery occlusive disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT05811364; https://clinicaltrials.gov/study/NCT05811364. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/51480.

13.
J Endovasc Ther ; : 15266028231219988, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38149463

RESUMO

PURPOSE: To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom. MATERIALS AND METHODS: A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields. Measurements were performed in the same phantom with and without the Anaconda endograft, to investigate the impact of the endograft on the local flow fields. Hemodynamic parameters, namely vector complexity (VC) and residence time (RT), were calculated for both iliac arteries. RESULTS: In both limbs, the vector fields were mostly unidirectional during the peak systolic and end-systolic velocity phases before and after endograft placement. Local vortical structures and complex flow fields were observed at the diastolic and transitional flow phases. The average VC was higher (0.11) in the phantom with endograft, compared to the phantom without endograft (0.05). Notably, in both left and right iliac arteries, the anterior wall regions corresponded to a 2- and 4-fold increase in VC in the phantom with endograft, respectively. RT simulations showed values of 1.3 to 6 seconds in the phantom without endograft. A higher RT (up to 25 seconds) was observed in the phantom with endograft, in which the left iliac artery, with LT in follow-up, showed 2 fluid stasis regions. CONCLUSION: This in vitro study shows that unfavorable hemodynamics were present mostly in the limb that thrombosed during follow-up, with the highest VC and longest RT. These parameters might be valuable in predicting the occurrence of LT in the future. CLINICAL IMPACT: This in-vitro study aimed to identify potential hemodynamic predictors for limb thrombosis following EVAR using ultrasound particle image velocimetry (echoPIV) technique. It was shown that unfavorable hemodynamic norms were present mostly in the thrombosed limb. Owing to the in-vivo feasibility of the echoPIV, future efforts should focus on the evaluation of these hemodynamic norms in clinical trials. Thereafter, using echoPIV as a bedside technique in hospitals becomes more promising. Performing echoPIV in pre-op phase may provide valuable insights for surgeons to enhance treatment planning. EchoPIV is also applicable for follow-up sessions to evaluate treatment progress and avoid/predict complications.

14.
JVS Vasc Sci ; 4: 100131, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38033397

RESUMO

Objective: The goal of this study was to determine to what extent aortic stent graft motion quantification is comparable between electrocardiogram (ECG)-gated computed tomography (CT) scans with reconstructions into 8 and 10 cardiac phases on CT scanners from two different vendors. Methods: An experimental setup that induces motion of an aortic stent graft, according to a predefined aortic blood pressure wave, was placed in two CT scanners of different vendors. The stent graft motion was captured using an ECG-gated CT technique and quantified using dedicated analysis algorithms. The calculated motion amplitudes and total traveled path lengths of stent segmentations were compared between scans reconstructed into 8 and 10 phases and between the scanners, after validation with sensor measurements and repeated measurements. Results: No difference in motion amplitudes in z-direction (craniocaudal direction) was observed between the reconstructions into 8 and 10 phases (0.02 mm; 95% confidence interval [CI], -0.01 to 0.05 mm; P = .358). The z-amplitudes differed by 0.04 mm (95% CI, 0.01-0.07 mm; P = .003) between the different CT scanners. Path lengths differed 0.07 mm (95% CI, 0.01-to 0.13 mm; P = .013) between the reconstructions into 8 and 10 phases and 0.13 mm (95% CI, 0.06-0.17 mm; P < .001) between the different scanners. Conclusions: The motion amplitudes can accurately be compared between 8 and 10 phases and between the two scanners, without differences larger than the voxel size of 0.3 × 0.3 × 0.5 mm. Clinical motion analysis results of different ECG-gated CT scans and CT scanners can be compared up to the accuracy of the CT scan.

15.
J Endovasc Ther ; : 15266028231209929, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37933525

RESUMO

OBJECTIVE: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability. DESIGN: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups. METHODS: Fenestrated endovascular aortic aneurysm repair stability was assessed considering the following variables: branch angle as the angle between the aorta and the target artery, end-stent angle as the angle between the end of the bridging stent and the native artery downstream from it, curvature and tortuosity index (TI) to describe the bending of the target artery. Body-bridging stent stability was assessed considering bridging stent flare lengths, the distances between the proximal sealing stent-ring and fenestrations and the distance between the fenestration and first apposition in the target artery. RESULTS: Renal branch angles significantly increased after FEVAR toward a perpendicular position (right renal artery from median 60.9°, inter quartile range [IQR]=44.2-84.9° preoperatively to 94.4°, IQR=72.6-99.8°, p=0.001 at 12-month follow-up; left renal artery [LRA], from 63.7°, IQR=55.0-73.0° to 94.3°, IQR=68.2-105.6°, p<0.001), while visceral branch angles did not. The mean dynamic curvature only decreased for the LRA from preoperative (3.0, IQR=2.2-3.8 m-1) to 12-month follow-up (1.9, IQR=1.4-2.6 m-1, p=0.027). The remaining investigated variables did not seem to show any changes over time in this cohort. CONCLUSIONS: Fenestrated endovascular aortic aneurysm repair for complex AAAs using the Anaconda fenestrated stent-graft and balloon-expandable Advanta V12 bridging stents demonstrated stable configurations up to 12-month follow-up, except for increasing renal branch angles toward perpendicular orientation to the aorta, yet without apparent clinical consequences in this cohort. CLINICAL IMPACT: This study provides detailed information on the cardiac-pulsatility-induced (dynamic) and longitudinal geometry deformations of the target arteries and bridging stents after fenestrated endovascular aortic aneurysm repair (FEVAR) up to 12-month follow-up. The configuration demonstrated limited dynamic and longitudinal deformations in terms of branch angle, end-stent angle, curvature, and tortuosity index (TI), except for the increasing renal branch angles that go toward a perpendicular orientation to the aorta. Overall, the results suggest that the investigated FEVAR configurations are stable and durable, though careful consideration of increasing renal branch angles and significant geometry alterations is advised.

16.
Cardiovasc Intervent Radiol ; 46(10): 1329-1345, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37526706

RESUMO

PURPOSE: To summarize the 5-year outcomes of drug-coated balloon (DCB) for the treatment of femoropopliteal lesions in patients with diabetes mellitus (DM) or chronic limb-threatening ischemia (CLTI) compared to non-DM and intermittent claudication (IC). METHODS: The IN.PACT Global study was a real-world prospective, multicenter, international, single-arm study that enrolled 1535 participants. Post hoc analyses were conducted for participants with DM (n = 560) versus non-DM (n = 842) and CLTI (n = 156) versus IC (n = 1246). Assessments included freedom from clinically driven target lesion revascularization (CD-TLR) through 60 months, a composite safety outcome (freedom from device- and procedure-related death through 30 days, and freedom from major target limb amputation and freedom from CD-target vessel revascularization within 60 months), and major adverse events (MAEs). RESULTS: Kaplan-Meier estimates of 60-month freedom from CD-TLR were 67.7% and 70.5% (p = 0.25) in the DM and non-DM cohorts; and 60.7% and 70.5% (p = 0.006) in the CLTI and IC cohorts. The Kaplan-Meier 60-month composite safety outcomes were 65.1% DM versus 68.9% non-DM (p = 0.12); 53.2% CLTI versus 69.1% IC (p < 0.001). Between DM and non-DM, MAE rates were not significantly different through 60 months except for all-cause mortality which was higher in DM (23.8% versus 16.6%; p < 0.001). Participants with CLTI had a higher cumulative incidence of major target limb amputation (6.8% versus 1.1%; p < 0.001) and all-cause mortality (37.4% versus 17.4%; p < 0.001) through 60 months compared to IC. CONCLUSIONS: In this real-world study, 5-year reintervention rates following DCB angioplasty were similar between DM and non-DM, but mortality rates were expectedly higher in patients with DM. Reintervention, mortality, and amputation rates were all higher in CLTI patients compared to IC, which is consistent with the known frailty of this patient population. LEVEL OF EVIDENCE: Level 3, Non-randomized controlled cohort/follow-up study.

17.
J Vasc Surg Cases Innov Tech ; 9(3): 101241, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37496654

RESUMO

Preprocedural image analysis and intraprocedural techniques to fully treat infrarenal abdominal aortic aneurysm sacs outside of the endograft with shape memory polymer (SMP) devices during endovascular aneurysm repair were developed. Prospective, multicenter, single-arm studies were performed. SMP is a porous, self-expanding polyurethane polymer material. Target lumen volumes (aortic flow lumen volume minus endograft volume) were estimated from the preprocedural imaging studies and endograft dimensions. SMP was delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. Technical success was achieved in all cases, defined as implanting enough fully expanded SMP volume to treat the actual target lumen volume.

18.
Surg Open Sci ; 13: 99-110, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37288439

RESUMO

Introduction: The use of an 'eversion' technique is not unequivocally proven to be superior to carotid endarterectomy with patch angioplasty. An up-to-date systematic review is needed for evaluation of benefits and harms of these two techniques. Methods: RCTs comparing eversion technique versus endarterectomy with patch angioplasty in patients with a symptomatic and significant (≥50 %) stenosis of the internal carotid artery were enrolled. Primary outcomes were all-cause mortality rate, health-related quality of life and serious adverse events. Secondary outcomes included 30-day stroke and mortality rate, (a) symptomatic arterial occlusion or restenosis, and adverse events not critical for decision making. Results: Four RCTs were included with 1272 surgical procedures for carotid stenosis; eversion technique n = 643 and carotid endarterectomy with patch closure n = 629. Meta-analysis comparing both techniques showed, with a very low certainty of evidence, that eversion technique might decrease the number of patients with serious adverse events (RR 0.47; 95% CI 0.34 to 0.64; p ≤ 0.01). However, no difference was found on the other outcomes. TSA demonstrated that the required information sizes were far from being reached for these patient-important outcomes. All patient-relevant outcomes were at low certainty of evidence according to GRADE. Conclusions: This systematic review showed no conclusive evidence of any difference between eversion technique and carotid endarterectomy with patch angioplasty in carotid surgery. These conclusions are based on data obtained in trials with very low certainty according to GRADE and should therefore be interpreted cautiously. Until conclusive evidence is obtained, the standard of care according to ESVS guidelines should not be abandoned.

19.
Radiol Res Pract ; 2023: 3721185, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388254

RESUMO

Background: The Nellix endovascular sealing system (EVAS) was a unique concept with regard to its sealing concept that failed, related to high migration rates. We investigated the changes in aortoiliac morphology during the cardiac cycle before and after EVAS using electrocardiography (ECG)-gated CT. Methods: Eight patients scheduled for EVAS were prospectively enrolled. ECG-gated CT scans were made pre- and postoperatively. Measurements were performed in the mid-systolic and mid-diastolic phases. Endpoints were changes in infrarenal aortoiliac morphology postoperatively compared to preoperatively and their changes in the cardiac cycle. Results: Both pre- and postoperatively, there were no changes during the cardiac cycle. EVAS caused an increase in neck diameter and surface in both phases (p < 0.001). EVAS increased the luminal AAA volume (p < 0.001), with a decrease in thrombus volume (p < 0.001) in both phases and an increase in total volume (p < 0.001) in the systolic phase. During follow-up, one patient presented with >5 mm migration. There were no differences in the movements of this patient compared to the remaining patients. Conclusion: The cardiac cycle had a very limited effect on the aortoiliac dynamics before and after EVAS and, therefore, there is probably not a role for ECG-gated CT in enhanced surveillance programs. EVAS itself has a significant impact on anatomy, particularly the neck diameter, length, and volumes of the AAA.

20.
J Endovasc Ther ; : 15266028231166539, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37114939

RESUMO

BACKGROUND: The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) reconstruction is an endovascular technique, developed to reconstruct the aortic bifurcation in the most optimal anatomical and physiological manner. Short-term data were promising, but long-term data are still lacking. The objective was to report the long-term outcomes of CERAB for extensive aorto-iliac occlusive disease and to identify predictors for loss of primary patency. METHODS: Consecutive electively treated patients with CERAB for aorto-iliac occlusive disease in a single hospital were identified and analyzed. Baseline and procedural data and follow-up were collected at 6-weeks, 6 months, 12 months, and annually thereafter. Technical success, procedural, and 30-day complications were evaluated, as well as overall survival. Patency and freedom from target lesion revascularization rates were analyzed using Kaplan Meier curves. Uni- and multivariate analysis were performed to identify possible predictors of failure. RESULTS: One hundred and sixty patients were included (79 male). Indication for treatment was intermittent claudication for 121 patients (75.6%) and 133 patients (83.1%) had a TASC-II D lesion. Technical success was obtained in 95.6% of patients and the 30-day mortality rate was 1.3%. The 5-year primary, primary-assisted, and secondary patency rates were 77.5%, 88.1%, and 95.0%, respectively, with a freedom-from clinically driven target lesion revascularization (CD-TLR) rate of 84.4%. The strongest predictor of loss of primary patency of CERAB was a previous aorto-iliac intervention (odds ratio [OR]=5.36 (95% confidence interval [CI]: 1.30; 22.07), p=0.020). In patients not previously treated in the aorto-iliac tract, 5-year primary, primary assisted, and secondary patency rates were 85.1%, 94.4%, and 96.9%, respectively. At 5-year follow-up, an improved Rutherford was found in 97.9% of patients and the freedom from major amputation rate was 100%. CONCLUSION: The CERAB technique is related to good long-term outcomes, particularly in primary cases. In patients that had prior treatment for aorto-iliac occlusive disease, there were more reinterventions and therefore surveillance should likely be more intense. CLINICAL IMPACT: The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) reconstruction was designed to improve outcomes of endovascular treatment of extensive aorto-iliac occlusive disease. At 5-year follow-up clinical improvement was found in 97.9% of patients without major amputations. The 5-year overall primary, primary-assisted, and secondary patency rates were 77.5%, 88.1%, and 95.0%, respectively, with a freedom-from clinically driven target lesion revascularization rate of 84.4%. Significantly better patency rates were observed for patients that were never treated before in the target area. The data implicate that CERAB are a valid treatment option for patients with extensive aorto-iliac occlusive disease. For patients previously treated in the target area, other treatment options might be considered, or more intensive follow-up surveillance is warranted.