Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Animals (Basel) ; 13(11)2023 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-37889743

RESUMO

Being the largest still-living terrestrial mammal on earth, an elephant's feet play an important role in its health status. The musculoskeletal structures in the forefoot are well described in the literature, but information about vascularization is limited. The novel aim of this work is to provide anatomical guidance to structures found in the forefoot, focusing on the arterial system. Initially, native CT and MRI sequences were taken of the left forefoot of a deceased 6-year-old female Asian elephant; the foot was then filled with an iodine-containing contrast medium through the a. mediana and the CT scans were repeated in the same position. The images obtained were processed with 3D Slicer software for the 3D reconstruction of the bones and arteries. The results clearly showed the palmar blood supply of the forefoot. A so far undescribed vessel was revealed, stemming from the a. metacarpea, supplying the first digit and the digital cushion. The course of the deep palmar arch's terminal section was also established. This paper provides the first description of the exact disposition of the arteries in the palmar aspect of an elephant's forefoot and may be used in planning surgeries in clinically affected animals.

2.
Acta Vet Hung ; 65(1): 1-12, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28244335

RESUMO

Despite numerous studies on cerebrospinal fluid (CSF) and its importance during hydrocephalus or myelography, no reliable values exist about its overall volume in dogs. In this study, our aim was to measure the intracranial (IC) volume of CSF in dogs and assess its possible relationship with body size and the symmetry of the lateral ventricles. We ran a 3D magnetic resonance imaging (MRI) sequence on the central nervous system of 12 healthy, male mongrel dogs between 3-5 years of age and 7.5-35.0 kg body weight. A validated semiautomatic segmentation protocol was implemented to segment the CSF and measure its volume. Values for the volume of the ventricular compartment were between 0.97 and 2.94 ml, with 62.1 ± 11.7% in the lateral ventricles, 17.6 ± 4.9% in the third ventricle, 4.9 ± 1.6% in the aqueductus mesencephali and 15.5 ± 6.6% in the fourth ventricle. In 11 cases a significant asymmetry was found between the lateral ventricles. The results suggest that it may be normal for a dog to have one of the lateral ventricles 1.5 times larger than the other. The correlation between body weight and CSF volume was linear, indicating that the current dosage protocols for myelography, based on a hypothetical proportional relationship with body weight, may have to be revised.


Assuntos
Peso Corporal/fisiologia , Cães/líquido cefalorraquidiano , Cães/fisiologia , Animais , Ventrículos Cerebrais/anatomia & histologia , Ventriculografia Cerebral , Meios de Contraste , Imageamento por Ressonância Magnética , Masculino
3.
Vet Radiol Ultrasound ; 56(6): 658-65, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26311617

RESUMO

Dosages for myelography procedures in dogs are based on a hypothetical proportional relationship between bodyweight and cerebrospinal fluid (CSF) volume. Anecdotal radiographic evidence and recent studies have challenged the existence of such a defined relationship in dogs. The objectives of this prospective cross-sectional study were to describe CSF volumes using magnetic resonance imaging (MRI) in a group of clinically healthy dogs, measure the accuracy of MRI CSF volumes, and compare MRI CSF volumes with dog physical measurements. A sampling perfection with application optimized contrast using different flip-angle evolution MRI examination of the central nervous system was carried out on 12 healthy, male mongrel dogs, aged between 3 and 5 years with a bodyweight range of 7.5-35.0 kg. The images were processed with image analysis freeware (3D Slicer) in order to calculate the volume of extracranial CSF. Cylindrical phantoms of known volume were included in scans and used to calculate accuracy of MRI volume estimates. The accuracy of MRI volume estimates was 99.8%. Extracranial compartment CSF volumes ranged from 20.21 to 44.06 ml. Overall volume of the extracranial CSF increased linearly with bodyweight, but the proportional volume (ml/bodyweight kilograms) of the extracranial CSF was inversely proportional to bodyweight. Relative ratios of volumes in the cervical, thoracic, and lumbosacral regions were constant. Findings indicated that the current standard method of using body weight to calculate dosages of myelographic contrast agents in dogs may need to be revised.


Assuntos
Cães/líquido cefalorraquidiano , Imageamento por Ressonância Magnética/veterinária , Animais , Peso Corporal , Vértebras Cervicais/anatomia & histologia , Meios de Contraste/administração & dosagem , Estudos Transversais , Processamento de Imagem Assistida por Computador/métodos , Vértebras Lombares/anatomia & histologia , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Sacro/anatomia & histologia , Medula Espinal/anatomia & histologia , Vértebras Torácicas/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA