Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 86(3): 1194-1211, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33847012

RESUMO

PURPOSE: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal-to-noise ratio (SNR), proton-spin relaxation times, image uniformity and proton density. METHODS: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57-element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice-profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR. RESULTS: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. CONCLUSIONS: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Sci Rep ; 7(1): 12138, 2017 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-28939857

RESUMO

The speed of conventional antimicrobial susceptibility testing (AST) is intrinsically limited by observation of cell colony growth, which can extend over days and allow bacterial infections to advance before effective antibiotics are identified. This report presents an approach for rapidly sensing mechanical fluctuations of bacteria and the effects of antibiotics on these fluctuations. Bacteria are adhered to a quartz crystal resonator in an electronic bridge that is driven by a high-stability frequency source. Mechanical fluctuations of cells introduce time-dependent perturbations to the crystal boundary conditions and associated resonant frequency, which translate into phase noise measured at the output of the bridge. In experiments on nonmotile E. coli exposed to polymyxin B, cell-generated frequency noise dropped close to zero with the first spectra acquired 7 minutes after introduction of the antibiotic. In experiments on the same bacterial strain exposed to ampicillin, frequency noise began decreasing within 15 minutes of antibiotic introduction and proceeded to drop more rapidly with the onset of antibiotic-induced lysis. In conjunction with cell imaging and post-experiment counting of colony-forming units, these results provide evidence that cell death can be sensed through measurements of cell-generated frequency noise, potentially providing a basis for rapid AST.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Fenômenos Biomecânicos/efeitos dos fármacos , Testes de Sensibilidade Microbiana/instrumentação , Infecções Bacterianas/tratamento farmacológico , Desenho de Equipamento , Escherichia coli/efeitos dos fármacos , Infecções por Escherichia coli/tratamento farmacológico , Humanos , Testes de Sensibilidade Microbiana/economia , Testes de Sensibilidade Microbiana/métodos , Polimixina B/farmacologia , Fatores de Tempo , Vibração
3.
Nanotoxicology ; 8(4): 394-403, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23611448

RESUMO

In evaluating nanoparticle risks to human health, there is often a disconnect between results obtained from in vitro toxicology studies and those from in vivo activity, prompting the need for improved methods to rapidly assess the hazards of engineered nanomaterials. In vitro studies of nanoparticle toxicology often rely on high doses and short exposure periods due to the difficulty of maintaining monolayer cell cultures over extended time periods as well as the difficulty of maintaining nanoparticle dispersions within the culture environment. In this work, tissue-engineered constructs are investigated as a platform for providing doses of nanoparticles over different exposure periods to cells within a three-dimensional environment that can be tuned to mimic in vivo conditions. Uptake of quantum dots (QDs) by model neural cells was first investigated in a high-dose exposure scenario, resulting in a strong concentration-dependent uptake of carboxyl-functionalised QDs. Poly(ethylene glycol) hydrogel scaffolds with varying mesh sizes were then investigated for their ability to support cell survival and proliferation. Cells were co-encapsulated with carboxyl-functionalised poly(ethylene glycol)-coated QDs at a lower dose than is typical for monolayer cultures. Although the QDs leach from the hydrogel within 24 h, they are also incorporated by cells within the scaffold, enabling the use of these constructs in future studies of cell behaviour and function.


Assuntos
Técnicas de Cultura de Células/instrumentação , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Pontos Quânticos/toxicidade , Alicerces Teciduais , Testes de Toxicidade/instrumentação , Animais , Técnicas de Cultura de Células/métodos , Sobrevivência Celular , Células PC12 , Ratos , Testes de Toxicidade/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA