Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38339622

RESUMO

A novel conductive composite based on PEDOT:PSS, BSA, and Nafion for effective immobilization of acetic acid bacteria on graphite electrodes as part of biosensors and microbial fuel cells has been proposed. It is shown that individual components in the composite do not have a significant negative effect on the catalytic activity of microorganisms during prolonged contact. The values of heterogeneous electron transport constants in the presence of two types of water-soluble mediators were calculated. The use of the composite as part of a microbial biosensor resulted in an electrode operating for more than 140 days. Additional modification of carbon electrodes with nanomaterial allowed to increase the sensitivity to glucose from 1.48 to 2.81 µA × mM-1 × cm-2 without affecting the affinity of bacterial enzyme complexes to the substrate. Cells in the presented composite, as part of a microbial fuel cell based on electrodes from thermally expanded graphite, retained the ability to generate electricity for more than 120 days using glucose solution as well as vegetable extract solutions as carbon sources. The obtained data expand the understanding of the composition of possible matrices for the immobilization of Gluconobacter bacteria and may be useful in the development of biosensors and biofuel cells.


Assuntos
Grafite , Polímeros , Polímeros/química , Soroalbumina Bovina , Carbono/química , Bactérias , Glucose/química
2.
Polymers (Basel) ; 15(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37765637

RESUMO

Conductive polymers and their composites are excellent materials for coupling biological materials and electrodes in bioelectrochemical systems. It is assumed that their relevance and introduction to the field of bioelectrochemical devices will only grow due to their tunable conductivity, easy modification, and biocompatibility. This review analyzes the main trends and trends in the development of the methodology for the application of conductive polymers and their use in biosensors and biofuel elements, as well as describes their future prospects. Approaches to the synthesis of such materials and the peculiarities of obtaining their nanocomposites are presented. Special emphasis is placed on the features of the interfaces of such materials with biological objects.

3.
Polymers (Basel) ; 14(24)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36559732

RESUMO

The possibility of using the microorganisms Pseudomonas sp. 7p-81, Pseudomonas putida BS394(pBS216), Rhodococcus erythropolis s67, Rhodococcus pyridinivorans 5Ap, Rhodococcus erythropolis X5, Rhodococcus pyridinivorans F5 and Pseudomonas veronii DSM 11331T as the basis of a biosensor for the phenol index to assess water environments was studied. The adaptation of microorganisms to phenol during growth was carried out to increase the selectivity of the analytical system. The most promising microorganisms for biosensor formation were the bacteria P. putida BS394(pBS216). Cells were immobilized in redox-active polymers based on bovine serum albumin modified by ferrocenecarboxaldehyde and based on a composite with a carbon nanotube to increase sensitivity. The rate constants of the interaction of the redox-active polymer and the composite based on it with the biomaterial were 193.8 and 502.8 dm3/(g·s) respectively. For the biosensor created using hydrogel bovine serum albumin-ferrocene-carbon nanotubes, the lower limit of the determined phenol concentrations was 1 × 10-3 mg/dm3, the sensitivity coefficient was (5.8 ± 0.2)∙10-3 µA·dm3/mg, Michaelis constant KM = 230 mg/dm3, the maximum rate of the enzymatic reaction Rmax = 217 µA and the long-term stability of the bioanalyzer was 11 days. As a result of approbation, it was found that the urban water phenol content differed insignificantly, measured by creating a biosensor and using the standard photometric method.

4.
Sensors (Basel) ; 22(21)2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36366221

RESUMO

Microbial mediator biosensors for surface water toxicity determination make it possible to carry out an early assessment of the environmental object's quality without time-consuming standard procedures based on standard test-organisms, and provide broad opportunities for receptor element modifying depending on the required operational parameters analyzer. Four microorganisms with broad substrate specificity and nine electron acceptors were used to form a receptor system for toxicity assessment. Ferrocene was the most effective mediator according to its high rate constant of interaction with the microorganisms (0.33 ± 0.01 dm3/(g × s) for yeast Saccharomyces cerevisiae). Biosensors were tested on samples containing four heavy metal ions (Cu2+, Zn2+, Pb2+, Cd2+), two phenols (phenol and p-nitrophenol), and three natural water samples. The «ferrocene- Escherichia coli¼ and «ferrocene-Paracoccus yeei, E. coli association¼ systems showed good operational stability with a relative standard deviation of 6.9 and 7.3% (14 measurements) and a reproducibility of 7 and 5.2% using copper (II) ions as a reference toxicant. Biosensor analysis with these systems was shown to highly correlate with the results of the standard method using Chlorella algae as a test object. Developed biosensors allow for a valuation of the polluted natural water's impact on the ecosystem via an assessment of the influence on bacteria and yeast in the receptor system. The systems could be used in toxicological monitoring of natural waters.


Assuntos
Técnicas Biossensoriais , Chlorella , Metais Pesados , Poluentes Químicos da Água , Metalocenos , Água/análise , Escherichia coli , Saccharomyces cerevisiae , Reprodutibilidade dos Testes , Ecossistema , Técnicas Biossensoriais/métodos , Metais Pesados/toxicidade , Metais Pesados/análise , Poluentes Químicos da Água/análise
5.
Biosensors (Basel) ; 12(10)2022 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-36290979

RESUMO

One of the main indices of the quality of water is the biochemical oxygen demand (BOD). A little over 40 years have passed since the practical application of the first microbial sensor for the determination of BOD, presented by the Japanese professor Isao Karube. This time span has brought new knowledge to and practical developments in the use of a wide range of microbial cells based on BOD biosensors. At present, this field of biotechnology is becoming an independent discipline. The traditional BOD analysis (BOD5) has not changed over many years; it takes no less than 5 days to carry out. Microbial biosensors can be used as an alternative technique for assessing the BOD attract attention because they can reduce hundredfold the time required to measure it. The review examines the experience of the creation and practical application of BOD biosensors accumulated by the international community. Special attention is paid to the use of multiple cell immobilization methods, signal registration techniques, mediators and cell consortia contained in the bioreceptor. We consider the use of nanomaterials in the modification of analytical devices developed for BOD evaluation and discuss the prospects of developing new practically important biosensor models.


Assuntos
Técnicas Biossensoriais , Oxigênio , Oxigênio/análise , Análise da Demanda Biológica de Oxigênio , Técnicas Biossensoriais/métodos , Água/análise
6.
Membranes (Basel) ; 12(10)2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36295743

RESUMO

Biomembranes based on an organosilica sol-gel matrix were used to immobilize bacteria Paracoccus yeei VKM B-3302 as part of a biochemical oxygen demand (BOD) biosensor. Diethoxydimethylsilane (DEDMS) and tetraethoxysilane (TEOS) were used as precursors to create the matrix in a 1:1 volume ratio. The use of scanning electron microscopy (SEM) and the low-temperature nitrogen adsorption method (BET) showed that the sol-gel matrix forms a capsule around microorganisms that does not prevent the exchange of substrates and waste products of bacteria to the cells. The use of DEDMS as part of the matrix made it possible to increase the sensitivity coefficient of the biosensor for determining BOD by two orders of magnitude compared to a biosensor based on methyltriethoxysilane (MTES). Additionally, the long-term stability of the bioreceptor increased to 68 days. The use of such a matrix neutralized the effect of heavy metal ions on the microorganisms' catalytic activity in the biosensor. The developed biosensor was used to analyze water samples from water sources in the Tula region (Russia).

7.
Biosensors (Basel) ; 12(9)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36140084

RESUMO

Microbial fuel cells (MFCs) are a variety of bioelectrocatalytic devices that utilize the metabolism of microorganisms to generate electric energy from organic matter. This study investigates the possibility of using a novel PEDOT:PSS/graphene/Nafion composite in combination with acetic acid bacteria Gluconobacter oxydans to create a pure culture MFC capable of effective municipal wastewater treatment. The developed MFC was shown to maintain its activity for at least three weeks. The level of COD in municipal wastewater treatment was reduced by 32%; the generated power was up to 81 mW/m2 with a Coulomb efficiency of 40%. Combining the MFC with a DC/DC boost converter increased the voltage generated by two series-connected MFCs from 0.55 mV to 3.2 V. A maximum efficiency was achieved on day 8 of MFC operation and was maintained for a week; capacitors of 6800 µF capacity were fully charged in ~7 min. Thus, G. oxydans cells can become an important part of microbial consortia in MFCs used for treatment of wastewaters with reduced pH.


Assuntos
Fontes de Energia Bioelétrica , Gluconobacter oxydans , Grafite , Purificação da Água , Fontes de Energia Bioelétrica/microbiologia , Compostos Bicíclicos Heterocíclicos com Pontes , Eletricidade , Eletrodos , Polímeros de Fluorcarboneto , Polímeros , Águas Residuárias/química
8.
Sensors (Basel) ; 22(16)2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-36015810

RESUMO

The possibility of the developing a biochemical oxygen demand (BOD) biosensor based on electroactive biofilms of activated sludge grown on the surface of a graphite-paste electrode modified with carbon nanotubes was studied. A complex of microscopic methods controlled biofilm formation: optical microscopy with phase contrast, scanning electron microscopy, and laser confocal microscopy. The features of charge transfer in the obtained electroactive biofilms were studied using the methods of cyclic voltammetry and electrochemical impedance spectroscopy. The rate constant of the interaction of microorganisms with the extracellular electron carrier (0.79 ± 0.03 dm3(g s)-1) and the heterogeneous rate constant of electron transfer (0.34 ± 0.02 cm s-1) were determined using the cyclic voltammetry method. These results revealed that the modification of the carbon nanotubes' (CNT) electrode surface makes it possible to create electroactive biofilms. An analysis of the metrological and analytical characteristics of the created biosensors showed that the lower limit of the biosensor based on an electroactive biofilm of activated sludge is 0.41 mgO2/dm3, which makes it possible to analyze almost any water sample. Analysis of 12 surface water samples showed a high correlation (R2 = 0.99) with the results of the standard method for determining biochemical oxygen demand.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Biofilmes , Técnicas Biossensoriais/métodos , Eletrodos , Oxigênio/análise , Esgotos , Água/análise
9.
3 Biotech ; 12(9): 231, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35996672

RESUMO

Electrochemical biosensors and biofuel cells are finding an ever-increasing practical application due to several advantages. Biosensors are miniature measuring devices, which can be used for on-the-spot analyses, with small assay times and sample volumes. Biofuel cells have dual benefits of environmental cleanup and electric energy generation. Application of nanomaterials in biosensor and biofuel-cell devices increases their functioning efficiency and expands spheres of use. This review discusses the potential of nanomaterials in improving the basic parameters of bioelectrochemical systems, including the sensitivity increase, detection lower-limit decrease, detection-range change, lifetime increase, substrate-specificity control. In most cases, the consideration of the role of nanomaterials links a certain type of nanomaterial with its effect on the bioelectrochemical device upon the whole. The review aims at assessing the effects of nanomaterials on particular analytical parameters of a biosensor/biofuel-cell bioelectrochemical device.

10.
Polymers (Basel) ; 14(8)2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35458293

RESUMO

Electropolymerized neutral red, thionine, and aniline were used as part of hybrid nanocomposite conductive polymers, to create an amperometric reagent-less biosensor for glucose determination. The structure of the obtained polymers was studied using infrared (IR) spectroscopy and scanning electron microscopy. Electrochemical characteristics were studied by cyclic voltammetry and impedance spectroscopy. It was shown that, from the point of view of both the rate of electron transfer to the electrode, and the rate of interaction with the active center of glucose oxidase (GOx), the most promising is a new nanocomposite based on poly(neutral red) (pNR) and thermally expanded graphite (TEG). The sensor based on the created nanocomposite material is characterized by a sensitivity of 1000 ± 200 nA × dm3/mmol; the lower limit of the determined glucose concentrations is 0.006 mmol/L. The glucose biosensor based on this nanocomposite was characterized by a high correlation (R2 = 0.9828) with the results of determining the glucose content in human blood using the standard method. Statistical analysis did not reveal any deviations of the results obtained using this biosensor and the reference method. Therefore, the developed biosensor can be used as an alternative to the standard analysis method and as a prototype for creating sensitive and accurate glucometers, as well as biosensors to assess other metabolites.

11.
Micromachines (Basel) ; 13(2)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35208428

RESUMO

Glucose is one of the most important monosaccharides found in the food, as a part of more complex structures, which is a primary energy source for the brain and body. Thus, the monitoring of glucose concentration is more important in food and biological samples in order to maintain a healthy lifestyle. Herein, an electrochemical glucose biosensor was fabricated by immobilization of glucose oxidase (GOX) onto poly(3,4-ethylenedioxythiophene):4-sulfocalix [4]arene (PEDOT:SCX)/MXene modified electrode. For this purpose, firstly, PEDOT was synthesized in the presence of SCX (counterion) by the chemical oxidative method. Secondly, MXene (a 2D layered material) was synthesized by using a high-temperature furnace under a nitrogen atmosphere. After that, PEDOT:SCX/MXene (1:1) dispersion was prepared by ultrasonication which was later utilized to prepare PEDOT:SCX/MXene hybrid film. A successful formation of PEDOT:SCX/MXene film was confirmed by HR-SEM, Fourier transform infrared (FT-IR), and Raman spectroscopies. Due to the biocompatibility nature, successful immobilization of GOX was carried out onto chitosan modified PEDOT:SCX/MXene/GCE. Moreover, the electrochemical properties of PEDOT:SCX/MXene/GOX/GCE was studied through cyclic voltammetry and amperometry methods. Interestingly, a stable redox peak of FAD-GOX was observed at a formal potential of -0.435 V on PEDOT:SCX/MXene/GOX/GCE which indicated a direct electron transfer between the enzyme and the electrode surface. PEDOT:SCX/MXene/GOX/GCE also exhibited a linear response against glucose concentrations in the linear range from 0.5 to 8 mM. The effect of pH, sensors reproducibility, and repeatability of the PEDOT:SCX/MXene/GOX/GCE sensor were studied. Finally, this new biosensor was successfully applied to detect glucose in commercial fruit juice sample with satisfactory recovery.

12.
3 Biotech ; 12(2): 42, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35096499

RESUMO

The work considered the properties of a biosensor based on a novel nanomaterial-modified thermally expanded graphite (TEGM). The main focus was on whether the procedure of additional graphite thermal expansion would affect the electrochemical properties of biosensors based on membrane fractions of acetic acid bacteria Gluconobacter oxydans. Raman spectroscopy, scanning electron microscopy and electrochemical analysis were used for the study. Raman spectra showed that the formation of TEGM led to its stratification into smaller particles and a better orderly layered structure with high "graphenization" degree. Modification of TEG led to the formation of additional cavities into which bacterial cells or bacterial membrane fractions could be immobilized and affect the electrical conductivity of the biosensors positively. Calculation of the heterogeneous charge transfer constants showed that processes occurring on the electrodes are quasi-reversible. The limiting stage of these processes is the transfer of an electron from a biological component on the electrode surface, not the diffusion of the analyte from the solution to the active centers of the enzyme. We showed the possibility of developing third-generation mediator-free biosensors for glucose detection based on TEGM, as well as of second-generation mediator biosensors for glucose, ethanol and glycerol detection.

13.
Expert Rev Anti Infect Ther ; 20(10): 1299-1308, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-33164589

RESUMO

INTRODUCTION: COVID-19 pandemic has been declared as a global emergency by the World Health Organization which has mounted global pressure on the healthcare system. The design and development of rapid tests for the precise and early detection of infection are urgently needed to detect the disease and also for bulk screening of infected persons. The traditional drugs moderately control the symptoms, but so far, no specific drug has been discovered. The prime concern is to device novel tools for rapid and precise diagnosis, drug delivery, and effective therapies for coronavirus. In this context, nanotechnology offers novel ways to fight against COVID-19. AREA COVERED: This review includes the use of nanomaterials for the control of COVID-19. The tools for diagnosis of coronavirus, nano-based vaccines, and nanoparticles as a drug delivery system for the treatment of virus infection have been discussed. The toxicity issues related to nanoparticles have also been addressed. EXPERT OPINION: The research on nanotechnology-based diagnosis, drug delivery, and antiviral therapies is at a preliminary stage. The antiviral nanomedicine therapies are cost-effective and with high quality. Nanoparticles are a promising tool for prevention, diagnosis, antiviral drug delivery, and therapeutics, which may open up new avenues in the treatment of COVID-19.


Assuntos
COVID-19 , Antivirais/uso terapêutico , Humanos , Nanotecnologia , Pandemias/prevenção & controle , SARS-CoV-2
14.
Biosensors (Basel) ; 11(9)2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34562922

RESUMO

Immobilization of the biocomponent is one of the most important stages in the development of microbial biosensors. In this study, we examined the electrochemical properties of a novel PEDOT:PSS/graphene/Nafion composite used to immobilize Gluconobacter oxydans bacterial cells on the surface of a graphite screen-printed electrode. Bioelectrode responses to glucose in the presence of a redox mediator 2,6-dichlorophenolindophenol were studied. The presence of graphene in the composite reduced the negative effect of PEDOT:PSS on cells and improved its conductivity. The use of Nafion enabled maintaining the activity of acetic acid bacteria at the original level for 120 days. The sensitivity of the bioelectrode based on G. oxydans/PEDOT:PSS/graphene/Nafion composite was shown to be 22 µA × mM-1 × cm-2 within the linear range of glucose concentrations. The developed composite can be used both in designing bioelectrochemical microbial devices and in biotechnology productions for long-term immobilization of microorganisms.


Assuntos
Ácido Acético , Bactérias , Técnicas Biossensoriais , Compostos Bicíclicos Heterocíclicos com Pontes , Carbono , Condutividade Elétrica , Eletrodos , Polímeros de Fluorcarboneto , Gluconobacter oxydans , Glucose , Grafite/química , Oxirredução , Polímeros , Poliestirenos
15.
Biosensors (Basel) ; 11(5)2021 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-34066417

RESUMO

Recent years have witnessed an ever-increasing interest in developing electrochemical biosensors based on direct electron transfer-type bioelectrocatalysis. This work investigates the bioelectrocatalytic oxidation of glucose by membrane fractions of Gluconobacter oxydans cells on screen-printed electrodes modified with thermally expanded graphite and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Electrooxidation of glucose was shown to occur without the presence of electron transport mediators. Chronoamperometric and cyclic voltametric characteristics showed an increase of anodic currents at electrode potentials of 0-500 mV relative to the reference electrode (Ag/AgCl). The direct electron transfer effect was observed for non-modified PEDOT:PSS as well as for PEDOT:PSS linked with crosslinkers and conductive fillers such as polyethylene glycol diglycidyl or dimethyl sulfoxide. Bioelectrodes with this composite can be successfully used in fast reagent-free glucose biosensors.


Assuntos
Técnicas Biossensoriais , Gluconobacter oxydans/fisiologia , Glucose/metabolismo , Compostos Bicíclicos Heterocíclicos com Pontes/metabolismo , Carbono , Condutividade Elétrica , Eletrodos , Grafite , Oxirredução , Polímeros/metabolismo , Poliestirenos
16.
3 Biotech ; 11(5): 222, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33968567

RESUMO

This work proposes a method of forming a microorganism-mediator(s) receptor system, in which the rates of separate stages of mediator bioelectrocatalysis are used as the basis for the development of biosensors for the biochemical oxygen demand (BOD) rapid assay. In the presence of a ferrocene mediator, the yeast Blastobotrys adeninivorans was shown to enable oxidation of a larger range of substrates as compared with other investigated microorganisms-bacteria Escherichia coli and yeast Ogataea polymorpha. The rate constants of the interaction of the yeast B. adeninivorans with nine compounds, electron transfer mediators, were determined; the best mediator for these microorganisms was found to be neutral red (k int = 0.681 ± 0.009 dm3/g s). Neutral red possesses a high rate of interaction with the ferrocene mediator (14,200 ± 100 dm3/mol s) shown earlier to be the most promising acceptor of electrons at a carbon paste electrode (0.4 ± 0.1 cm/s). These features enabled the formation of a two-mediator ferrocene-neutral red system to be used in a biosensor. A two-mediator-based biosensor had a higher sensitivity (the lower limit of detected BOD concentrations, 0.16 mg/dm3) than that of a one-mediator system based on neutral red and ferrocene. Analysis of ten samples from surface water reservoirs showed the combination of ferrocene, neutral red and the yeast B. adeninivorans to enable the data that highly correlated (R = 0.9693) with those of the standard method.

17.
ACS Omega ; 6(8): 5146-5157, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33681556

RESUMO

Semiconducting single-walled carbon nanotubes (s-SWCNTs) are considered as a replacement for silicon in field-effect transistors (FETs), solar cells, logic circuits, and so forth, because of their outstanding electronic, optical, and mechanical properties. Herein, we have studied the reaction of pristine SWCNTs dispersed in a pluronic F-68 (PF-68) polymer solution with para-amino diphenylamine diazonium sulfate (PADDS) to separate nanotubes based on their metallicity. The preferential selectivity of the reactions was monitored by changes in the semiconducting (S22 and S33) and metallic (M11) bands by ultraviolet-visible-near infrared spectroscopy. Metallic selectivity depended on the concentrations of PADDS, reaction time, and the solution pH. Furthermore, separation of pure s-SWCNTs was confirmed by Raman spectroscopy and Fourier-transform infrared spectroscopy. After the removal of metallic SWCNTs, direct current electric field was applied to the pure s-SWCNT solution, which effectively directed the nanotubes to align in one direction as nanotube arrays with a longer length and high density. After that, electrically aligned s-SWCNT solution was cast on a silicon substrate, and the length of the nanotube arrays was measured as ∼2 to ∼14 µm with an areal density of ∼2 to ∼20 tubes/µm of s-SWCNTs. Next, electrically aligned s-SWCNT arrays were deposited on the channel of the FET device by drop-casting. Field-emission scanning electron microscopy and electrical measurements have been carried out to test the performance of the aligned s-SWCNTs/FETs. The fabricated FETs with a channel length of 10 µm showed stable electrical properties with a field-effect mobility of 30.4 cm2/Vs and a log10 (I on/I off) current ratio of 3.96. We envisage that this new chemical-based separation method and electric field-assisted alignment could be useful to obtain a high-purity and aligned s-SWCNT array network for the fabrication of high-performance FETs to use in digital and analog electronics.

18.
RSC Adv ; 11(6): 3445-3451, 2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35424276

RESUMO

Flexible energy storage devices have received great interest due to the increasing demand for wearable and flexible electronic devices with high-power energy sources. Herein, a novel hybrid flexible hexagonal boron nitride integrated graphene paper (BN/GrP) is fabricated from 2D hexagonal boron nitride (h-BN) nanosheets integrated with graphene sheets dispersion via a simple vacuum filtration method. FE-SEM indicated that layered graphene nanosheets tightly confined with h-BN nanosheets. Further, the Raman spectroscopy confirmed successful integration of BN with graphene. As-prepared BN/GrP free-standing flexible conductive paper showed high electrical conductivity of 5.36 × 104 S m-1 with the sheet resistance of 8.87 Ω sq-1. However, after 1000 continuous bending cycles, the BN/GrP sheet resistance increased just about 8.7% which indicated good flexibility of the paper. Furthermore, as-prepared BN/GrP showed excellent specific capacitance of 321.95 F g-1 at current density of 0.5 A g-1. In addition, the power and energy densities were obtained as 3588.3 W kg-1, and 44.7 W h kg-1, respectively. The stability of the prepared flexible electrode was tested in galvanostatic charge/discharge cycles, where the results showed the 96.3% retention even after 6000 cycles. These results exhibited that the proposed BN/GrP may be useful to prepare flexible energy-storage systems.

19.
Biosensors (Basel) ; 9(4)2019 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-31739608

RESUMO

This paper considers the effect of multiwalled carbon nanotubes (MWCNTs) on the parameters of Gluconobacter oxydans microbial biosensors. MWCNTs were shown not to affect the structural integrity of microbial cells and their respiratory activity. The positive results from using MWCNTs were due to a decrease in the impedance of the electrode. The total impedance of the system decreased significantly, from 9000 kOhm (G. oxydans/chitosan composite) to 600 kOhm (G. oxydans/MWCNTs/chitosan). Modification of the amperometric biosensor with nanotubes led to an increase in the maximal signal from 65 to 869 nA for glucose and from 181 to 1048 nA for ethanol. The biosensor sensitivity also increased 4- and 5-fold, respectively, for each of the substrates. However, the addition of MWCNTs reduced the affinity of respiratory chain enzymes to their substrates (both sugars and alcohols). Moreover, the minimal detection limits were not reduced despite a sensitivity increase. The use of MWCNTs thus improved only some microbial biosensor parameters.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Gluconobacter oxydans/isolamento & purificação , Nanotubos de Carbono/química , Catálise
20.
Anal Sci ; 35(9): 1037-1043, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31155546

RESUMO

The characteristics of an electrochemical biosensor based on a Prussian-blue screen-printed electrode containing glucose oxidase incorporated into polyelectrolyte microcapsules (PMC) are considered. PMC with the embedded enzyme were formed using sodium polystyrene sulfonate and poly(allylamine hydrochloride). The characteristics were compared with those of the enzyme immobilized in chitosan gel. We assessed the dependences of biosensor signals on the composition of the buffer solution, on the glucose concentration; the operational and long-term stabilities. The enzyme immobilized in PMC proved to be more sensitive to buffer molarity at a maximum within 35 - 40 mM. The apparent Michaelis constants were 1.5 and 4.1 mM at the immobilization in, respectively, chitosan and PMC. The developed biosensors were used to assay commercial juices. The biosensors' data on the glucose contents were shown to have a high correlation with the standard spectrophotometric assay (0.92 - 0.95%), which implies a possible application of the fabricated biosensors in foodstuff analysis.


Assuntos
Técnicas Biossensoriais/métodos , Quitosana/química , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Polieletrólitos/química , Técnicas Biossensoriais/instrumentação , Soluções Tampão , Calibragem , Cápsulas , Eletroquímica , Eletrodos , Ferrocianetos/química , Géis , Glucose/análise , Poliaminas/química , Poliestirenos/química