Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 39(16): 1330-7, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24825159

RESUMO

STUDY DESIGN: A comparative study of 2 cohort series of surgically treated patients with adolescent idiopathic scoliosis (AIS) who were retrospectively analyzed, with level III evidence. OBJECTIVE: To compare the effect on the cervical sagittal balance of 2 AIS correction constructs, namely, all pedicle screws and hybrid instrumentation using hooks and pedicle screws. SUMMARY OF BACKGROUND DATA: An inverse relationship between cervical and thoracic kyphosis in AIS has been found in pediatric patients after concave derotation using hybrid constructs with pedicle screws and hooks. METHODS: Two series of 25 nonconsecutive patients with Lenke type-I AIS who underwent spinal fusion were retrospectively reviewed. In 1 series, the patients were treated with all thoracic pedicle screw constructs. In the other series, the correction was achieved by using hybrid constructs. Preoperative and 2-year follow-up radiographical examinations were evaluated, measuring the following parameters: C2-C7 sagittal angle, displacement of C2-C7 plumb line, T1 sagittal tilt, T1-T5 and T5-T12 sagittal profile, and C7-S1 global sagittal balance. RESULTS: In both groups, there was a lordotic effect on the T5-T12 kyphosis after surgery, with an average loss of 6.1° for hybrid and 7.7° for pedicle screws. When the postoperative data were compared, the intergroup differences were found only in the sagittal C2-C7 Cobb angle, showing a mean kyphotic trend (-5.2°) in the pedicle screws group compared with a mean lordotic trend (1.8°) in the hybrid group (P < 0.05). In both techniques, the patients with upper-instrumented vertebra at T4 or below showed a lordotic effect that was more evident in the hybrid constructs (+9.4° ± 11.3 vs. +0.3° ± 11.4). In those with the upper-instrumented vertebra at T3 or higher levels, both techniques had a kyphotic effect that was more severe in the patients of the pedicle screws group (-7.0° ± 12.6 vs. -2.8° ± 10.5). CONCLUSION: Independent of the surgical technique used, the cervical spine had a tendency to decompensate and acquire a kyphotic sagittal profile. Constructs based on all pedicle screws have a stronger hypokyphotic effect on the thoracic spine, with a predisposition to greater decompensation of the cervical spine. Kyphotic changes in the C2-C7 sagittal alignment induced by scoliosis correction are correlated with the level of the upper-instrumented vertebra.


Assuntos
Vértebras Cervicais/patologia , Cifose/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Escoliose/cirurgia , Vértebras Torácicas/patologia , Adolescente , Parafusos Ósseos , Feminino , Seguimentos , Humanos , Cifose/diagnóstico por imagem , Cifose/etiologia , Masculino , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Parafusos Pediculares , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA