Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Biomed Eng ; 6(1): 2, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468322

RESUMO

BACKGROUND: MAR algorithms have not been productized in interventional imaging because they are too time-consuming. Application of a beam hardening filter can mitigate metal artifacts and doesn't increase computational burden. We evaluate the ability to reduce metal artifacts of a 0.5 mm silver (Ag) additional filter in a Multidetector Computed Tomography (MDCT) scanner during CT-guided biopsy procedures. METHODS: A biopsy needle was positioned inside the lung field of an anthropomorphic phantom (Lungman, Kyoto Kagaku, Kyoto, Japan). CT acquisitions were performed with beam energies of 100 kV, 120 kV, 135 kV, and 120 kV with the Ag filter and reconstructed using a filtered back projection algorithm. For each measurement, the CTDIvol was kept constant at 1 mGy. Quantitative profiles placed in three regions of the artifact (needle, needle tip, and trajectory artifacts) were used to obtain metrics (FWHM, FWTM, width at - 100 HU, and absolute error in HU) to evaluate the blooming artifact, artifact width, change in CT number, and artifact range. An image quality analysis was carried out through image noise measurement. A one-way analysis of variance (ANOVA) test was used to find significant differences between the conventional CT beam energies and the Ag filtered 120 kV beam. RESULTS: The 120 kV-Ag is shown to have the shortest range of artifacts compared to the other beam energies. For needle tip and trajectory artifacts, a significant reduction of - 53.6% (p < 0.001) and - 48.7% (p < 0.001) in the drop of the CT number was found, respectively, in comparison with the reference beam of 120 kV as well as a significant decrease of up to - 34.7% in the artifact width (width at - 100 HU, p < 0.001). Also, a significant reduction in the blooming artifact of - 14.2% (FWHM, p < 0.001) and - 53.3% (FWTM, p < 0.001) was found in the needle artifact. No significant changes (p > 0.05) in image noise between the conventional energies and the 120 kV-Ag were found. CONCLUSIONS: A 0.5 mm Ag additional MDCT filter demonstrated consistent metal artifact reduction generated by the biopsy needle. This reduction may lead to a better depiction of the target and surrounding structures while maintaining image quality.

2.
Psychosomatics ; 61(1): 39-48, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31611047

RESUMO

BACKGROUND: Anti-N-methyl-D-aspartate (NMDA) receptor encephalitis causes substantial neurological disability. Autoantibodies causing encephalitis directed against the neuronal cell surface or synapse are of diagnostic importance giving the possibility of successful immunotherapy. OBJECTIVE: In this study, we aim to provide supporting evidence that brain 18F-FDG-PET may be helpful in identifying likely patterns of regional brain glucose metabolism. METHODS: Thirty-three patients (18 men and 15 women; age range of 17-55 y) with positive NMDA receptor antibody encephalitis that underwent an 18F-FDG-PET imaging examination were prospectively selected and compared with a reference group of 14 brain 18F-FDG-PET scans from healthy volunteers using voxel-based statistical analysis. Clusters of hyper- and hypo-metabolism were reported for the whole sample of patients (FWE-corrected P < 0.05), and uncorrected at P < 0.005 for a group of relapsed patients. RESULTS: Mixed metabolic patterns (focal/bilateral hypermetabolism in the temporal lobe, insula, and cerebellum; associated with severe bilateral hypometabolism in the occipital and parietal lobes) were found. CONCLUSIONS: Our findings suggest that 18F-FDG-PET should be included as an imaging tool when assessing affected patients in the clinical workup to rule out anti-NMDA encephalitis and help determine the most effective treatment.


Assuntos
Encefalite Antirreceptor de N-Metil-D-Aspartato/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Adolescente , Adulto , Encefalite Antirreceptor de N-Metil-D-Aspartato/metabolismo , Encefalite Antirreceptor de N-Metil-D-Aspartato/fisiopatologia , Afasia/fisiopatologia , Encéfalo/metabolismo , Encéfalo/fisiopatologia , Catatonia/fisiopatologia , Cerebelo/diagnóstico por imagem , Cerebelo/metabolismo , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/metabolismo , Delírio/fisiopatologia , Eletroencefalografia , Feminino , Fluordesoxiglucose F18 , Alucinações/fisiopatologia , Humanos , Letargia/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Transtornos da Memória/fisiopatologia , Memória de Curto Prazo , Pessoa de Meia-Idade , Transtornos dos Movimentos/fisiopatologia , Lobo Occipital/diagnóstico por imagem , Lobo Occipital/metabolismo , Lobo Parietal/diagnóstico por imagem , Lobo Parietal/metabolismo , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/metabolismo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA